Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAdmitted-Finance | ₹8.1 L | L1 | Admitted-Finance |
| 2 | L2₹9.8 LAdmitted-Finance HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | ₹9.8 L | L2 | Admitted-Finance |
| 3 | L3₹10.2 LAdmitted-Finance | ₹10.2 L | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical not enlisted in requisite category |
| 5 | Not Admitted-Fee/PreQual/Technical H NO 1 8 3 22 4 SURYA NAGAR TADI COMPLEX CHIKKADAPALLY HYDERABAD 500020 | HYDERABAD | HYDERABAD | TELANGANA | 500020 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | omsai thermax engineers L2 | BRITE INDUSTRIES L1 | AKSHITA ELECTRICAL L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Install, Commissioning & Testing of Air Cooled Ductable Split Air Conditioner of 8.5 TR or higher capacity (1W + 1S) with a desired temperature range of 8 to 15 Deg C perfectly suitable / compatible for / with existing system / arrangement / Ducting etc. complete all as specified & as directed & to the entire satisfaction of the Engr-In-Charge. Set Model No : ACADS08513, ODU Model No : ACDCUA08513 & IDU Model No : ACDEU85CZGIMR410 of Make : VOLTAS or techno-commercially equivalent of BLUESTAR/HITACHI/DAIKIN/CARRIER. | 1 | Each job | 9,81,000 ₹9.8 L | 8,08,088.4 ₹8.1 L | 10,21,500 ₹10.2 L |
| 1.01Detailed Technical Specification of the Air Cooled Ductable Split Air Conditioner of 8.5 TR or higher capacity is as follows : Indoor Unit : (a) Air Flow - 5780 CHM (b) Evaporator Fan - Centrifugal Forward Curved Fan, Double Inlet Double Width (c) Power Supply - 230 V, 1 Ph, 50 Hz (AC Supply with Earth) Outdoor Unit : (d) No of Units / Set - 01 No (e) No of Compressors / CU - 01 No (f) Compressor type - Hermetic Scroll (g) Power Supply - 3 Ph, 415 V, 50 Hz (AC Supply with Earth) (h) Condenser Fan - Axial (j) No of Fans / CU - 01 No (k) MCB / Breaker Rating - 63 A (3Ph) (l) Cable Size (Material) Incomer - 16 Sqmm 4 Core (Cu) / 25 Sqmm 4 Core (Al) (m) Cable Size (Material) ODU to IDU - 3 Core x 1.5 Sqmm (Cu) + 01 x Interlocking Cable b/w IDU & ODU (n) Type of Refrigerant - R 410a or latest Microprocessor Based Ducted Unit Controller : (o) Large LCD Screen - For easy readability (p) Auto Start Mode - For Automatic Start, after a Power Failure (q) Inbuilt Temp Sensor - For Precise control within +/- 0.5 Deg C (r) Modes of Operation - 4 (Cool, Dry, Fan & Energy Saver) (s) Motor Protection Device - Protection from Phase Reversal, Imbalance, Overload & Single Phasing (t) Energy Saving Mode - Auto Switch Off of Condenser Fans when Condenser Trips (u) Fan Speed Selection - 4 (Low, Medium, High, Auto) (v) Self-Diagnosis Function - Constant Monitoring of Errors with Alarms (w) Equalization of Compressor Runtime - To ensure a longer life for Compressors (x) On / OFF Timer - To Schedule AC run-time in a day | ||||||
| 1.02IMPORTANT NOTES : 1) Design / Drawing / BOM / technical specifications of the complete Air Cooled Ductable Split Air Conditioner of 8.5 TR or higher capacity system duly showing the layout & other details etc. is to be obtained from OEM / Auth Channel Partner / Supplier & is to be got approved from Engr-in-charge & GE before placing final order. 2) Necessary Test / Guarantee / Warranty certificates etc. to be submitted in Original to the Engr-in-Charge. 3) The complete installation, commissioning & testing of the complete Air Cooled Ductable Split Air Conditioner of 8.5 TR or higher capacity system is to be got done from the OEM or their auth Rep/Sister Concern/Channel Partners only & reports submitted to Engr-In-Charge in duplicate. 4) The cost of periodical/routine servicing/maintenance including repairs/replacement of spare parts etc. including periodical checking of the complete System for the complete defect liability period (2 Years from certified date of completion of work) from the authorized service dealer/rep as & when required/due is deemed to be included in the unit quoted rates. 5) Detailed Technical Specifications w.r.t. the Items/Eqpts/System of the complete Air Cooled Ductable Split Air Conditioner of 8.5 TR or higher capacity system has been highlighted above, same to be adhered to by the Contr/Firm. Contr/Firm is therefore required to visit the site of work for any doubts / clarifications w.r.t. specifications/qty etc. before quoting of the Tender. Any query/clarifications etc. after conclusion of the Contract shall NOT be entertained & decision of the AO shall be final & binding. 6) Quoted rates are deemed to be inclusive of the following : (i) Copper Piping incl Insulation, Interconnecting Cabling, Drain Pipes, Canvas connection for Existing Ducting, Timer etc. complete all as specified & as directed & to the entire satisfaction of the Engr-In-Charge. (ii) Guarantee for a minimum period of 24 Months from the date of commissioning. (iii) Related Civil Works, Opening & finishing of Civil Walls for Copper Piping / Ducting Insulation etc. incl making good the disturbed surfaces & matching as per existing etc. complete all as specified & as directed & to the entire satisfaction of the Engr-In-Charge. (iv) Supply, Laying & Testing of Incoming Power Cables upto each ODU with MCCB/MCB controls to the entire satisfaction of Engr-In-Charge. (v) MS Supports for Indoor / Outdoor Units & allied items / eqpts. incl making good the disturbed surfaces & matching as per existing etc. complete all as specified & as directed & to the entire satisfaction of the Engr-In-Charge. (vi) Civil Pedestal / MS Structure for Outdoor Units incl making good the disturbed surfaces & matching as per existing etc. complete all as specified & as directed & to the entire satisfaction of the Engr-In-Charge. (vii) Taking down carefully old / existing / unsv Ductable Split ACs incl connected items & depositing the same to MES Storeyard. Quoted rate is deemed to be inclusive of opening of civil / ventillation infra etc. (as per site reqmts) to facilitate dismantling / removal of old / existing / unsv Ductable Split ACs incl connected items & installation of the new items / eqpts with & incl the reqmt of Spl T&P like Crane / Hydra / Scaffolding arrangements etc. & making good the subject civil / ventillation infra etc. as per existing complete all as specified & as directed & to the entire satisfaction of the Engr-In-Charge. (viii) Cost of periodical/routine servicing/maintenance including repairs/replacement of spare parts etc. including periodical checking of the complete System for the complete defect liability period (2 Years from certified date of completion of work) from the authorized service dealer/rep as & when required/due is deemed to be included in the unit quoted rates. (ix) Anything missed out in the technical specifications but technically required for efficient installation / working of the complete Air Cooled Ductable Split Air Conditioner of 8.5 TR or higher capacity system is deemed to be included in the quoted rates. | ||||||
| 1.03(v) MS Supports for Indoor / Outdoor Units & allied items / eqpts. incl making good the disturbed surfaces & matching as per existing etc. complete all as specified & as directed & to the entire satisfaction of the Engr-In-Charge. (vi) Civil Pedestal / MS Structure for Outdoor Units incl making good the disturbed surfaces & matching as per existing etc. complete all as specified & as directed & to the entire satisfaction of the Engr-In-Charge. (vii) Taking down carefully old / existing / unsv Ductable Split ACs incl connected items & depositing the same to MES Storeyard. Quoted rate is deemed to be inclusive of opening of civil / ventillation infra etc. (as per site reqmts) to facilitate dismantling / removal of old / existing / unsv Ductable Split ACs incl connected items & installation of the new items / eqpts with & incl the reqmt of Spl T&P like Crane / Hydra / Scaffolding arrangements etc. & making good the subject civil / ventillation infra etc. as per existing complete all as specified & as directed & to the entire satisfaction of the Engr-In-Charge. (viii) Cost of periodical/routine servicing/maintenance including repairs/replacement of spare parts etc. including periodical checking of the complete System for the complete defect liability period (2 Years from certified date of completion of work) from the authorized service dealer/rep as & when required/due is deemed to be included in the unit quoted rates. (ix) Anything missed out in the technical specifications but technically required for efficient installation / working of the complete Air Cooled Ductable Split Air Conditioner of 8.5 TR or higher capacity system is deemed to be included in the quoted rates. | ||||||
Updated dates
Tender Value
₹10.4 L
EMD Value
₹20,864
Closing Date
2 Apr 2026, 6:00 pmClosed
GE (AFA) Hyderabad
GE (AFA) Hyderabad, Dundigal, Hyderabad
SPECIAL REPAIRS REPLACEMENT OF QTY-02 DUCT ACs OF SRE ATCR- 3S RADAR OF 8.5 TON CAPACITY EACH AT AFA HYDERABAD
2026_MES_755507_1
8664
Open Tender
Electrical and Maintenance Works
180 days
HYDERABAD
As per NIT
5 documents required · 5 mandatory
₹500
GE (AFA) HYDERABAD
₹20,864
Yes
3 Jun 2026
7 Mar 2026
4 Apr 2026
7 Mar 2026
2 Apr 2026
14 Mar 2026
7 Mar 2026 - 13 Mar 2026
Supply, Install, Commissioning & Testing of Air Cooled Ductable Split Air Conditioner of 8.5 TR or higher capacity (1W + 1S) with a desired temperature range of 8 to 15 Deg C perfectly suitable / compatible for / with existing system / arrangement / Ducting etc. complete all as specified & as directed & to the entire satisfaction of the Engr-In-Charge. Set Model No : ACADS08513, ODU Model No : ACDCUA08513 & IDU Model No : ACDEU85CZGIMR410 of Make : VOLTAS or techno-commercially equivalent of BLUESTAR/HITACHI/DAIKIN/CARRIER.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
TENDERPAGES8664.pdf
Tender Documents • 0.54 MB
BOQ_846233.xls
BOQ • 0.47 MB
Download all tender documents and submit your bid