| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹6.9 LQualified Make: Uniline
Model: UNILINE 1 B VASHISHT NAGER BABYAL ROAD NEAR HARYANA GRAMIN BANK AMBALA CANTT AMBALA HARYANA 133001 INDIA | AMBALA | HARYANA | 133001 | Make: Uniline
Model: UNILINE | L1 | Qualified | |
| 2 | L2₹7.0 L+₹6,070 (0.88%)Qualified Make: KEPTRON
Model: KEPTRON-KE 440-10-16400 110 A PATPARGANJ VILLAGE NEAR COMMUNITY CENTRE DELHI 110091 EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | Make: KEPTRON
Model: KEPTRON-KE 440-10-16400 | L2 | Qualified | |
| 3 | L3₹7.2 L+₹26,070 (3.78%)Qualified Make: Uniline
Model: UNILINE CHANDRASEKHARPUR BHUBANESWAR ODISHA 751016 INDIA | KHORDHA | ODISHA | 751016 | Make: Uniline
Model: UNILINE | L3 | Qualified | |
| 4 | Disqualified Make: LUMINOUS
Model: LUMINOUS LD10000 415 4TH FLOOR VISHWADEEP TOWER DISTRICT CENTER JANAKPURI SOUTH WEST DELHI DELHI 110058 | WEST DELHI | DELHI | 110058 | Make: LUMINOUS
Model: LUMINOUS LD10000 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
19 May 2018, 4:00 pmClosed
Online UPS Online UPS ( 5 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 10.0 KVA 10.0kva Technology IGBT-PWM with inbuilt isolation transformer igbt-pwmwithinbuiltisol ationtransformer Input Power single phase 160V - 260V sinewave
50Hz singlephase160v-260vs inewave50hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz
3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 60 60 Minimum VAH (VAH) 4500 Warranty for UPS (Years) 1 1
2
3
4
5 Movable trolly for Batteries With with Warranty for battery 1 1
2 Degree of Protection IP21 IP21
IP20 Cabling 5 meters for input and out put With With
Without Paralleling kit for With With
Without 1/4 synchronising Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) </= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage
Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage
Output AC Volt age
Current
Frequency
Battery Voltage and Current Yes - Indicators for mains presence
Battery charging and discharging
Output Over Load
Low Battery Voltage Yes - REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C
two cycles of (12+12) hours each 2007) Yes - 2/4 Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. 46/14/BT/NISE - Type Test Certificate date 04/03/2015 - Name of Lab NISE - Address of Lab GHAZIABAD - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Somorjit Singh Wangkhem 248002
Divison Headquaters Army Area
Clement Town 5 15 EMD Required No ePBG Required No
73305
GEM/2018/B/10456
Online UPS
15 days
Uttarakhand; Dehradun
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Online UPS Online UPS ( 5 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 10.0 KVA 10.0kva Technology IGBT-PWM with inbuilt isolation transformer igbt-pwmwithinbuiltisol ationtransformer Input Power single phase 160V - 260V sinewave | - | - | - |
| 50Hz singlephase160v-260vs inewave50hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz | - | - | - |
| 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 60 60 Minimum VAH (VAH) 4500 Warranty for UPS (Years) 1 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 Movable trolly for Batteries With with Warranty for battery 1 1 | - | - | - |
| 2 Degree of Protection IP21 IP21 | - | - | - |
| IP20 Cabling 5 meters for input and out put With With | - | - | - |
| Without Paralleling kit for With With | - | - | - |
| Without 1/4 synchronising Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) </= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage | - | - | - |
| Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage | - | - | - |
| Output AC Volt age | - | - | - |
| Current | - | - | - |
| Frequency | - | - | - |
| Battery Voltage and Current Yes - Indicators for mains presence | - | - | - |
| Battery charging and discharging | - | - | - |
| Output Over Load | - | - | - |
| Low Battery Voltage Yes - REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C | - | - | - |
| two cycles of (12+12) hours each 2007) Yes - 2/4 Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. 46/14/BT/NISE - Type Test Certificate date 04/03/2015 - Name of Lab NISE - Address of Lab GHAZIABAD - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Somorjit Singh Wangkhem 248002 | - | - | - |
| Divison Headquaters Army Area | - | - | - |
| Clement Town 5 15 EMD Required No ePBG Required No | - | - | - |
Exempted
19 May 2018
9 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_73305.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .