Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC D NO LIG 98 RAJEEV NAGAR KURMANNAPALEM VISAKHAPATNAM 530 048 | VISAKHAPATANAM | ANDHRA PRADESH | 530048 | ₹22.5 L Quoted ₹23.2 L | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹25.3 L+₹2.0 L (8.81%)Rejected-Finance D NO 4 96 40 27 FLAT NO 307 GREEN CASTLE APARTMENT GOPALAKRISHNA NAGAR SUJATHANAGAR VISAKHAPATNAM 530 051 | VISAKHAPATANAM | ANDHRA PRADESH | 530051 | ₹25.3 L+₹2.0 L (8.81%) | L2 | Rejected-Finance Being not L1 |
| 3 | L3₹25.7 L+₹2.5 L (10.6%)Rejected-Finance D NO 35 14 13 1 R P PETA KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | ₹25.7 L+₹2.5 L (10.6%) | L3 | Rejected-Finance Being not L1 |
| 4 | L4₹26.7 L+₹3.4 L (14.8%)Rejected-Finance D NO 38 39 86 3 4 SAIKRUPA RESIDENCY 104 AREA BAPUJI NAGAR MARRIPALEM VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | ₹26.7 L+₹3.4 L (14.8%) | L4 | Rejected-Finance Being not L1 |
| 5 | L5₹27.1 L+₹3.9 L (16.8%)Rejected-Finance | ₹27.1 L+₹3.9 L (16.8%) | L5 | Rejected-Finance Being not L1 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
22 Oct 2022, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR/MAINTOF VCBS, RMUS, DISTRIBUTION TRANSFORMER, EXTERNAL ELECTRICAL DISTRIBUTION SYSTEM INCLUDING REPAIR/CALIBRATION OF RELAYS, METERS AND OTHER ALLIED WORKS AT NAD TECHNICAL AREA AND NAD COLONY RESIDENTIAL AREA UNDER AGE E/M-II OF GE(U-I) V
2022_MES_555764_1
8469/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
Class D
8 documents required · 8 mandatory
₹500
Garrison Engineer Utility-I
₹86,000
Yes
10 Nov 2022
3 Oct 2022
24 Oct 2022
3 Oct 2022
22 Oct 2022
17 Oct 2022
Amount
M&L for disconnecting carefully electrical connection from both HT/ LT (primary & secondary) sides of the transformer, keeping them at safe side and taking out the transformer/Voltage stabiliser indoor/ outdoor type of capacity 500 KVA to 750 KVA, 11 KV/433KV, step down any make for carrying out complete overhauling which shall comprise of the following:-
a) M&L for lifting, transporting, handling the transformer to workshop and back to the original location after complete overhauling.
b) Conducting the tests on core and windings as per IS, magnetic imbalance, short circuit etc. in presence of Engr-in-Charge and test results shall be signed both by the contractor and Engineer -in-Charge and kept on record.
Note:- (i) Any damage to insulators/ bushes/ windings etc. while in the custody of the contractor shall be made good at no extra cost to Department. The serviceability of the transformer shall be checked and confirmed by the contractor before taking into his custody. (ii) M&L for rewinding/ re-insulation of HT/ LT (primary/ secondary) coils, bushes, studs, Transformer oil, cable box, replacement of bucholtz relay/ MOG if any etc will be measured and paid separately.
All as per Item No. 1 herein before but transformer/Voltage stabiliser indoor/ outdoor type of capacity up to 250 KVA to 400 KVA
All as per Item No. 1 herein before but transformer/Voltage stabiliser indoor/ outdoor type of capacity up to 100 KVA to 200 KVA
Filtration of transformer oil of transformers/ FRMUs installed at various locations to achieve di-electric strength not less than 60 KV at 2.5mm gap as per relevant IS with portable filtration plant, testing of the oil for the di-electric strength before filtration and after filtration complete all as directed by the Engineer-in-Charge.
Supply and topping up of transformer oil with di-electric strength not less than 60 KV in to the conservator tank/ body tank of the transformer/ OCB/ FRMUs etc at various locations complete all as directed by the Engineer-in-Charge. [Make: Power oil/ Transol/ Savita Chemicals]
M&L for rewinding of distribution (HT/LT) transformers of capacity ( 500 KVA to 750 KVA)/ type by winding the defective coils with new copper wire as per I.S. of same gauge and existing size together with new insulated materials/ bracings before placing in to the transformer and assembling the coil with new insulation and fitting the coils in the chamber, testing and commissioning the transformer and recording the test results complete all as directed. [Note: M&L for re-insulation of serviceable coils will be measured & paid separately under relevant items.]
M&L for rewinding of distribution (HT/LT) transformers of capacity ( 100 KVA to 400 KVA)/ type by winding the defective coils with new copper wire as per I.S. of same gauge and existing size together with new insulated materials/ bracings before placing in to the transformer and assembling the coil with new insulation and fitting the coils in the chamber, testing and commissioning the transformer and recording the test results complete all as directed. [Note: M&L for re-insulation of serviceable coils will be measured & paid separately under relevant items.]
M&L for re-insulating windings of HT/ LT distribution transformers of capacity ( 100 KVA to 750 KVA) / size/ type by strip opening of HT/ LT coils (i.e. Primary/ secondary coils) from core assembly safely, unwinding the HT/ LT coils (i.e. Primary/ secondary coils) complete, removing the old defective insulation paper and replacing with new DPC insulation to the copper conductor, re-varnishing of the windings with super varnish including heating/ drying/ backing complete carefully and thoroughly inside the heating chamber at suitable temperature to obtain required value of insulation resistance etc. all as per IS 1986-87 and as directed by Engr-in- charge.
Disconnection of the Distribution Transformer from HT and LT supply mains, removing of Bus duct and Bus bar, Leakage arresting to following transformers by draining out of oil, after arrangement of necessary empty oil drums, buckets etc., dismantling of top cover and accessories, dismantling of LT bushings by disconnecting leads/jumpers from inside, replacement of gaskets and oil seals and re fixing of the LT bushings, making internal and external connections, replacement of cover gasket and accessories, refixing of accessories and cover, filling of transformer oil complete, and making cable connections and for energising the transformer. (Cost includes materials like gaskets and oil seals and labour, the Bushing and bushings rods to be measured and paid separately).
500 kVA to 750 kVA
250 kVA to 400 kVA
up to 200 KVA
Disconnecting the HT/LT connections of following transformers i.e (Bus duct / Cable bunch) keeping all the cables out from the HT/LT sides, physically checking the transformer for healthiness, performing the transformer tests like Meggar test, Ratio Test, Magnetic Balance test and short circuit tests for checking the condition of transformer complete and test results shall be submitted by the contractor. Note:- (i) If the transformer found satisfactory then HT/LT connections shall be done by the contractor and has to charge the transformer. (ii) If the transformer fails in these tests then the contractor has to shift the transformer for winding /overhauling. (iii) Cost of Transportation / winding / overhauling is exclusive of rate quoted by the contractor.
500 kVA to 750 kVA
250 kVA to 400 Kva
Up to 200 KVA
Shifting the Transformer from existing site to another site within 3 Km distance range by Dismantling of HT and LT cables, jumpers and bus bars including LT busbar cable boxes and close the transformers for loading in to Vehicle with the help of crane, transportation to another site, unloading, cable connections both HT and LT, testing and commissioning.
(a) 500 kVA to 750 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 KVA
M&L for replacement of Silica gel breather assembly complete with breather unit and silica gel including connecting with proper necessary gaskets if necessary, including removing the unserviceable breather assembly.
(a) 500 kVA to 750 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 KVA
M&L for replacement of Conservator tank complete unit and including connecting with proper necessary gaskets if necessary, including removing the unserviceable Conservator tank.
(a) 500 kVA to 750 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 KVA
M&L for replacement gun metal drain valves of transformers of following capacities including dismantling old one:- MAKE :- UPADHYAY/ LEADER/ZOLOTO/KIRLOSKAR/AUDCO/VENUS
(a) 500 KVA to 750 KVA
(b) 250 KVA to 400 KVA
(c) up to 200 KVA
Supply and fix in repair in repairs off load tap changer assembly suitable for any make with 7 tapping position including opening top cover, conservator etc.
(a) 500 kVA to 750 kVA
(b) up to 400 KVA
Supply and fix in repair of (WTI) Winding Temperature Indicator of following distribution transformers
(a) 500 kVA to 750 kVA
(b) up to 400 KVA
Supply and fix in repair LT Bushings made out Porcelain and suitable length/size all as per existing, complete the following capacity distribution transformers of any make/size/type all as directed including dismantling old one.
(a) 500 kVA to 750 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 KVA
Supply only HT Bushings made out Porcelain and suitable length/size all as per existing, complete the following capacity distribution transformers of any make/size/type all as directed including dismantling old one.
(a) 500 kVA to 750 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 KVA
Supply only LT Bushing rod made out of Brass/Copper with threading and suitable length/size all as per existing metal parts / bolts etc, complete the following capacity distribution transformers of any make/size/type all as directed including dismantling old one.
(a) 500 kVA to 750 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 KVA
Supply only HT Bushing rod made out of Brass/Copper with threading and suitable length/size all as per existing including metal parts / bolts etc, complete the following capacity distribution transformers of any make/size/type all as directed including dismantling old one.
(a) 500 kVA to 750 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 KVA
S&F in repair of (OTI) Oil Temperature indicator of following distribution transformers
(a) 500 kVA to 750 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 KVA
S&F in repair Drain plugs to valves/conservator caps of the sizes 3/4", 1", 1.5" valves and plugs of the following capacity distribution transformers of any make/size/type all as directed including dismantling old one.
(a) 500 kVA to 750 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 KVA
S&F in repair Oil gauge glass with gaskets of the following capacity distribution transformers of any make/size/type all as directed.
(a) 500 kVA to 750 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 KVA
M&L for preparation of old painted surfaces of transformers with coarse cloth/ brush and painting throughout externally on exposed surfaces with two coats of smoke grey colour synthetic enamel paint including writing of transformer details on plinth in white enamel paint on black enamel paint back ground complete including one coat of white wash for base foundation all as specified and directed by Engineer-in-charge for the following capacity in-door/ out-door type transformer:-
(a) 500 kVA to 750 kVA
(b) 250 kVA to 400 kVA
(c) up to 200 KVA
Clearing of bushes/small plants up to root level around and surroundings areas E/M installations (i.e.Two Pole/ Four structures, outdoor-substation yards & Misc E/M installations etc) including surface dressing n.exc 15 cm deep and removing debris to a distance n.exc 50m complete all as directed
Supply and lay Graded coarse aggregate of size 20 mm dia size upto height of 0.15 Mtr over 0.1 Mtr of sand cushioning in outdoor sub-station yards including surface dressing n.exc 15 cm deep and removing debris to a distance n.exc 50 m before laying of sand all as directed. Note : Punned thickness of sand will be measured and paid separately.
Excavation in trenches n.exc 1.5mtr wide and not exc 1.5mtr depth and getting out in Soft/loose soil all as directed.
Returning and filling in of excavated material ay type including spreading, leveling, watering and well ramming in layers not exceeding 25 cm each.
Removal of surplus excavated material of any type not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
M&L for Sand cushioning/sand covering for underground cable protection/substation yard complete all as specified. Note: Punned thickness only will be measured and paid.
Supplying and laying reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx 180mm x 40mm, laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
M&L for GI pipe light grade 100 mm dia for cable protection on road crossings /plinth protection with fixed to the pole wall etc. suitable fittings for cable protection .
M&L cable jointing kit for 11 KV (Earthed) grade XLPE cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for size 3 core 120 to 185 Sqmm including testing after jointing complete all as directed . Make: M-Seal/ Birla -3M/ Denson/Raychem Note : Earth work will be measured and paid separately.
M&L cable jointing kit for 11 KV (Earthed) grade XLPE cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for size 3 core 240 to 300 Sqmm including testing after jointing complete all as directed . Make: M-Seal/ Birla -3M/ Denson/Raychem Note : Earth work will be measured and paid separately.
M&L cable jointing kit for 11 KV (Earthed) grade XLPE cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 120 to 185 Sqmm including testing after jointing complete all as directed . Make: M-Seal/ Birla -3M/ Denson/Raychem. Note : Earth work will be measured and paid separately.
M&L cable jointing kit for 11 KV (Earthed) grade XLPE cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 240 to 300 Sqmm including testing after jointing complete all as directed . Make: M-Seal/ 3M/ Raychem. Note : Earth work will be measured and paid separately.
S&L in repair XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured ,electric power cables heavy duty with aluminium conductor, 11000 Volts grade ( earthed) of size 3 core 185 Sqmm complete in trenches/ ducts/ on pole etc complete all as directed . Make: Universal/Polycab/ KEI /Havells/Gloster
S&L in repair XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured ,electric power cables heavy duty with aluminium conductor, 11000 Volts grade ( earthed) of size 3 core 240 Sqmm complete in trenches/ ducts/ on pole etc complete all as directed . Make: Universal/ KEI/Polycab /Havells/Gloster
M&L for detecting HT 11KV UG cable faults located in any stretch/ depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system, HV surge generator, fault pin point surge wave receiver, cable identification instrument , cable tracer for exact location of under ground cable routes. Note: The rate quoted deemed to be inclusive of transportation of equipment and charges for service engineer . The fault locator will be arranged by contractor only.
M&L for repair and servicing of HT (HT 11 KV) four pole structure by replacing Aluminium PG clamps, GI bolts and nuts, pieces of ACSR conductor with insulation sleeve RYB of any size as jumpers including lubricating the moving parts of AB switch and cleaning of all disc and pin insulators and applying silicon compound for prevention of arcing due to dust/ salt deposits over the surfaces including preparation of surfaces, applying zinc chromate primer on rusted surfaces and applying one coat of aluminum paint to the entire structure complete all as directed. Note:-Rate quoted shall be inclusive of two coats of white wash on exposed concrete .
All as per item No. 40 above but for two pole structure
Servicing,Inspecting,checking,overhauling,cleaning by using of blower,Lubrication ,greasing and carrying out preventive maintanance of RMU capacity 11 KV, 250/350 MVA including calibrating the relay by conducting secondary injection tests and RMU in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge. Notes: (i) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound, painting of RMU panels with approved colour including lettering details all as per exisitng etc.
Supply & fixing in repair of the following parts of RMU (Make : Schineider)
Self powered relay with O/C , S/C , E/F protection.Relay should have a front USB port for laptop interface , LCD display ,10 event records, 5 fault records, min 2 setting group and keypad for setting parameters for the relay- 1No
CT having Ratio 100-50/1-1A for Class - 1.0, 2.5VA for metering and Class 10P10, 2.5VA for protection- 1Set
Cable termination bushing suitable for upto 1 RUN 3Cx185 Sq mm, XLPE cable- 1Set
Cable termination cover boots (Push on type) -1Set
Three Phase (R/Y/B) indicating lamps - 1Set
11KV/230V AC, 1KVA control transformer - 1No
Battery and battery charger, 12Ah, (I/P-230V AC, O/P - 24V DC) - 1No
Spring Charging motor
S & F in repair Notice plate of 1.6 mm thick of size 25 CM X 20 CM mild steel sheet vitreous enameled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT 11 KV .
M & L for disc insulator porcelain vitreous brown 145 mm height & 225 mm dia ball and socket type two in series assembly with cast aluminium 4 U bolt tension hardware and tension clamps for conductors working pressure HT 11 KV complete including dismantling old one all as specified & directed.
Material for pin insulator porcelain vitreous brown insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut for 11000 volts grade 150 mm dia & 150 mm height, complete including dismantling old one all as specified
Supply and install HT 11 KV, 200 Amp outdoor type gang operated single break switch Tilting type vertical/ Horizontal mounting consisting of hot dip galvanised channel iron base having 2 Nos 11 KV Post type insulator in stack and 3 stack per phase copper or copper alloy high pressure heavily tinned contacts plated MS arcing horns capable of breaking the magnetizing current complete with horizontal connecting bar GI pipe as down rod levers coupling & operating handle with locking arrangement complete.
S & Install drop out lift OFF HT 11 KV, 200 Amp fuse link consisting of channel iron base having 2 Nos 11 KV post type insulators in stack & 2 stack per phase complete with fuse carrier of SRBP tube with heavily tinned non ferrous metal parts and spring loaded phosphor bronze contact manufactured as per IS 9385 Complete
M&L in repair for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 32 x 6mm by means of bolts, nuts, check nuts & washers of galvanized iron or steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate), "mild steel angle iron frame" made out of MS angle iron of size 40x 40 x 6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering and 40mm dia light grade, GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical "plate No '3' of SSR and connected to earthing test point all as specified and indicated including testing complete.
S & F in repair following spares of GOD 11 KV grade, 200 Amp rating in position and testing etc.
(a). Male contact
(b). Female contact
(c). Tinned copper flexible jumper
(d). MS Jumper carrier
(e). Back connector plate
M&L for replacement of Bucholtz relay for transformer of capacity 500 KVA to 750 KVA
Disconnect and taking out the IDMT/ Numeric/ Microprocessor based relay of any type of any Make from 11 KV HT panel at P-5 Sub Stn NAD & TRS-II, cleaning the contacts, calibrating the relay by conducting secondary injection tests, checking of current transformer, rectification of defects in control wiring for proper tripping of circuit breakers through CTs and relay and tripping coils, adjustment/setting to plug and time multiplier settings of the relay to achieve the discrimination in tripping, tune/synchronise upstream breaker relay settings, re-installation of relay, testing & commissioning etc complete all as specified and as directed.
Note: The Contractor has to arrange necessary testing Kits, testing equipments, tools etc. Rental rates for the testing/calibration kits & connected equipments are deemed to be included in the quoted rate. Testing & tuning shall be carried out in the presence of representative of the Department, to the satisfaction of the Department.
Taking down HT switch gear (Vacuum circuit breaker ) at P- 5 Sub Stn, TRS-I, TRS-II & FRCS Sub stn at NAD of capacity 11 KV 250/350 MVA comprising of repairs, complete overhauling/servicing, carrying out preventive maintenance alongwith testing of breakers by current injection test and refixing the same after repairs/ overhauling:
Note: (i) The servicing includes for busbar duct chamber, cable alleys and connecting accessories (ii) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound, painting of VCB panels with approved colour including lettering details all as per existing etc. to put in to the VCBs and panels in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge. (iii) Major spares like Breaker bushings, vacuum interrupter assly, busbar spout, busbar spout connections, circuit spout/circuit spout connections/buffer fixed contacts, moving contacts, tank assly/barriers, solenoid spares, dependent/spring mechanism/ motor mechanism, trip unit etc will be measured and paid separately under relevant items of Schedule 'A'. However the rate quoted shall be deemed to include for any other minor spares require replacement. (iv) The servicing shall be carried out by Auhtorised service centre as approved by GE
Supply only the following spares suitable for 250 MVA to 450 MVA HT switch gear VCBs and 11 KV HT panel repair work under relevant Schedule
CTs epoxy cast wound primary CTs with minimum primary current 50 to 100 A, double ratio, double core (Protection core-5P10 & Metering core- Class 1.0), 25 KA for 1 sec of 15 VA minimum Burden.
Supply only 1.5 sqmm flexible PVC stranded copper conductor cable, unsheathed, 1100 V grade for control wiring.
Supply only 2.5 sqmm flexible PVC stranded copper conductor cable, unsheathed, 1100 V grade for control wiring.
LED Indication Lamps
Shunt trip coil 110 V DC/220 V DC
Shunt trip coil 110 V DC/220 V DC assembly
Breaker control switch
Busbar Spout
Circuit spout
Control circuit fuses 2 A to 63 A
HRC fuse (PT HT side)
PT plug contact
Multifunction meter, Digital type (Displaying A, V, PF, Hz, KVA, KW, KVAR, KWh, Karsh etc.) Class 1/0.5 with RS485 port for communication in Modbus protocol. Make : L&T/Conzerve/ HPL/ (SOCOMEC)/AE/Havells
VCB buffers
110 Volt DC closing coil assembly
Push to trip knob red assembly
Push to trip knob green assembly
Ratchet wheel
Nylon release lever
VCB charging powl
Shutters for racking shaft
Bus bar support insulator for VCB panel
Vaccume Interrupter Bottle VG2 Make : Schnider/Areva
Rectifier
Supply, Install, Testing and commissioning of REF 615, Feeder Protection and Control Relay, Protections 50, 51, 50N, 51N, 46, 49, 64R, 67, 67N, 27, 59, 59N, 25, 81U, 81O, df/dt, 95, Measurement for 3I, I0, 3U, U0, Kw, KVA, PF, Hz, Kwh, 12 DI + 10 DO, One front RJ45 Port, One Rear RS485 Port for Modbus Protocol, Draw out Type with CT Shorting feature, Small LCD Display feature including taking down old relay of any description complete all as specified and as directed. [Make: Model No. REF615 of ABB Make or its equivalent in Siemens/Schneider]
M&L for replacement of damaged space heater in HT VCB 11 kv with new one suitable to operate on 110 Volts DC supply complete with necessary wiring and control cable with toggle switch and all as directed by engr-in-charge.
Thermostat
Supply & fixing in replacement of Lightning arresters 11KV grade expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp
MSN ENGINEERING WORKS
M/S CHANDRA ENGINEERS AND CONTRACTORS
VENKATESWARA ENGINEERS AND CONTRACTORS
SRI SAI KRISHNA ENGINEERING WORKS
M.V.K.ENTERPRISES
jyothi constructions
general electricals
Saket Enterprises
UV POWER TECH
SRIESWARI ENTERPRISES
Bhuvaneswari Electrical Works
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .