| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹11.3 L+₹76,295 (7.23%)Rejected-Finance C O BHAGYODAY STORES BAZAR CHOWK NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹12.1 L+₹1.6 L (15.0%)Rejected-Finance | L3 | Rejected-Finance BEING L3 |
Tender Value
₹13.3 L
EMD Value
₹26,700
Closing Date
27 May 2025, 6:00 pmClosed
GE (I) CG PORBANDAR
COAST GUARD DHQ NO 1, OPP BIRLA FACTORY
PROVISION OF AIR CONDITIONER LED LIGHTS PRESSURE PUMP AND WATER COOLER AT VADINAR UNDER GE (I) CG PORBANDAR
2024_MES_688588_2
8039A/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
VADINAR
AS PER NIT
9 documents required · 9 mandatory
₹500
GE I CG PORBANDAR
₹26,700
Yes
30 Jun 2025
1 May 2025
29 May 2025
1 May 2025
27 May 2025
9 May 2025
Amount
SCHEDULE 'A' E/M
Supply & installation of Air Cooled Inverter based split AC unit with cooling functions and suitable to operate at Cooling Mode. Air conditioner will have following conditions:- (i) Refrigerent - R 410a (ii) EER - min 3.5 w/w (5 star rating) (iii) Tonnage - 1.5 (iv) Indoor Noise Level - Not more than 48 Db (v) Filter - (a) Must have PM 2.5 µ Filter (b) Electrostatic dust filter (c) Oxidizer dust filter (vi) Functions of remote : (a) Air directional control (b) Auto Timer (c) Economic sleep mode (d) Auto fan speed (e) Auto swing (f) Temp display (g) Turbo mode All specification will be as per IS-1391 (Part 2) 1992 Room Air Conditioners
Supply & installation of Air Cooled Inverter based split AC unit with cooling functions and suitable to operate at cooling Mode. Air conditioner will have following conditions:- (i) Refrigerent - R 410a (ii) EER - min 3.5 w/w (4 star rating) (iii) Tonnage - 2.0 (iv) Indoor Noise Level - Not more than 48 Db (v) Filter - (a) Must have PM 2.5 µ Filter (b) Electrostatic dust filter (c) Oxidizer dust filter (vi) Functions of remote : (a) Air directional control (b) Auto Timer (c) Economic sleep mode (d) Auto fan speed (e) Auto swing (f) Temp display (g) Turbo mode All specification will be as per IS-1391 (Part 2) 1992 Room Air Conditioners
Note:- Following will be inclusive in rate for item no 1 & 2 :- (a) Piping length upto 15 mtr will be inclusive in item (b) Installation will include fixing the outdoor unit on the platform as per direction of Engineer in Charge (c) Installation will also include civil work for making hole on the wall and putting the iron sleeve for passing the refrigerant pipe (d) Testing and commissioning of the Air conditioner to the entire satisfaction of Engineer in Charge (e) Contractor will provide warranty of 5 years for compressor from the date of installation (f) 5% of Air conditioner will be tested by the Garrison Engineer for Energy Efficiency and all the functions provision in the Air conditioner (g) Contractor provide complete free service in warrenty period by the company
Supply & Fixing motor strater 3 module, Modular MCB 16 Amps 1 module including suitable for PVC Box 3 Module with Cover plate, Complete all as specified and directed by Engineer-in-Chage.
Supply & Fixing Modular Socket 6A/16A - 2/3 pin 2 Module type, 240 volts, including suitable for PVC Box 2 Module with Cover plate, Complete all as specified and directed by Engineer-in-Charge.
Material & labour for Sub main wiring with two runs of 4.00 Sqmm single core PVC insulated but unsheathed multstranded copper conductor FRLS 1100 Volts grade cable, drawn through and including PVC casing capping, wall suface, making good the disturbed surfaces of walls/ceiling/floor etc., including accessories and one run of 4.0 Sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade cable as earth conductor, Complete all as specified and directed by Engineer-in-Charge. Note: All runs of cable and 1 run of conduit/casing capping shall be measured and paid as one metre length of unit.
Supply & fixing PVC Flexible AC Drain Pipe of tough Water Long Hose, extenstion Pipe for AC outlet drain water and leak resistant AC pipe cover casing, Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Energy efficient recess mounted LED panel fitting 35 Watt suitable for 2' x 2' grid in white colour lumen not less that 120 lmn per watt, total lumen flux 4200 lmn, input voltage 220 to 240 V, power factor should be 90 with high quality diffuser for uniform light & high Efficiency made from CRCA sheet, pre-coated white colour separate replaceable electronic driver, lumen constant of 6500K colour temperature with current electronic connections, Complete all as specified and directed by Engineer-in-Charge.
Supply, install, testing and commisioning 0.4 HP (0.3 KW) Booster Pressure Pump with 24L Tank, discharge range 0-2400 lph, head 27 mtr single phase suitable for 2-3 bathroom, 230 volt, motor power 0.3 KW including necessary accessories like tee, bend etc., Complete all as specified and directed by Engineer-in-Charge. Make: Grundfos or equivalent in Crompton/Kirlosker
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors of size 25mm including all fittings such as male & female union, elbow, tee etc., Complete all as specified and directed by Engineer-in-Charge.
Supplying and laying of CPVC valve of size 25mm, Complete all as specified and directed by Engineer-in-Charge.
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity 40/80 Ltr, Complete all as specified and directed by Engineer-in-Charge. Make: Blue star/Voltas
Supply & Fixing Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed fancy type, chromium plated of size 25mm dia, Complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Rotational moulded polyethylene water storage tanks of capacity 500 litres (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including PCC 1:2:4 of 100mm thickness, Complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, Complete all as specified and directed by Engineer-in-Charge.
Material and labour for providing point wiring with two runs of 2.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core copper stranded FRLS PVC insulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings / fixture etc and open recessed type Plastic Enclosure (Plastic Switch Board) ISI marked (IS 14782) for housing one 15 A Switch / sockets all a specified and directed by Engr-in-charge.
Supply & Fixing Modular switch 16 Amp, 1 way, 1 Module (ISI Marked), Complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Modular socket 6/16 Amp, 2/3 pin combined, 2 Module (ISI Marked), Complete all as specified and directed by Engineer-in-Charge.
KRISHNA ENGINEERING (BID ID -3297552)
ABR Trading Co (BID ID -3301328)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .