Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 LAccepted-AOC COOCH BEHAR | COOCH BEHAR | COOCH BEHAR | WEST BENGAL | 736101 | L1 | Accepted-AOC STANDS LOWEST | |
| 2 | L2₹2.3 L+₹3,975.85 (1.75%)Rejected-Finance COOCHBEHAR HAZRAPARA | JALPAIGURI | WEST BENGAL | 735122 | L2 | Rejected-Finance HIGHER THAN L1 | |
| 3 | L3₹2.4 L+₹11,758.30 (5.18%)Rejected-Finance 29 195 SANTI PARA JALPAIGURI | JALPAIGURI | JALPAIGURI | WEST BENGAL | 735101 | L3 | Rejected-Finance HIGHER THAN L1 |
| Sl No | Description | Qty | Unit | DIAMOND ELECTRICAL WORKS L1 | MESSRS BHOWMIK AND CO L3 | GEETA CONSTRUCTION L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply and delivery at site 15KVA, 3 phase oil cooled type Servo Motor operated copper wound line voltage corrector conforming to IS-9815 (Pt.-1)-1994 suitable for un-balanced input voltage with following specification including first filling oil as per IS-335 where applicable.(Make: Approve make of P.H.E. Dte.)
a) Input Voltage:- 3 phase, Main supply may or may not be balanced with respect to Phase to Phase 250V.-500V.Phase to Neutral-145V.-290V.
b) Out put voltage:- 3 phase balanced out put voltage. Phase to Phase 400V.or 415V.± 1% ,Phase to Neutral- 230V.-240V.±1% ( Provision should be made to adjust the Variation of out put voltage per phase by a variable pot oil within ± 5% of out put).
c) Line regulation:- Out put voltage should remain well with ±1% of set voltage ( From Minimum to Maximum i.e. either 400V. or 415V. supply variation).
d) Load regulation : Out put voltage should remain neutral well within ±1% of set voltage be (From no load to full load ) i.e. either 400V. or 415V.
e) Correction speed:- Better than 35 Volt / Second.
f) Efficiency:- Better than 95% on full load.
g) Cut off limit for ( minimum & maximum ) by limit switch with Audio & Visual.
h) Metering Indication:- By Selector switch provision should be made available to measure input mains supply and out put voltage other stabilizer for load current measurement an Ammeter with selector switch should be available.
i) Lamp Indication :- For Input & Output should be provided. ( 3 lamps per side ).
j) MCB Protection: For Input side.
k) Load protection : HRC Fuse on each out put phase should be available.
l) Output over shoot:- Beyond 210V to . 255V /phase in case of “ MANUAL MODE” & voltage protection :AUTO MODE” operation.(Manufacturing test certificate should be provided at the time of delivery)
m) VISUAL Indication for under voltage & over voltage of output.
n) Manual Mode:- Up & Down correction with O / P voltage over shoot protection. Beyond 210 V-255 V. per phase.
o) Nature of cooling:- Oil/ air cooled system .
p) Electric current over load protection .
q) Circuit for delay out put .
r) Input high voltage cut - off above 500 V.
s) Mode of Operation:- AUTO/MANUAL with a provision to restore the normal working of the unit “STANDBY OPERATION” should be available increase of any Electronic failure in auto mode.
t) Auto Mode:- Normal * Standby.( Manufacturing test certificate should be Provided at the time of delivery) | 1 | No. | 1,40,000 ₹1,40,000 Lowest | 1,45,000 ₹1,45,000 | 1,40,600 ₹1,40,600 |
| 2.00Supply and delivery of following materials at site: | ||||||
| 2.01 | a) 100 Amp, 415 V, 4 pole on load changeover switch | 1 | No. | 10,832 ₹10,832 Lowest | 12,000 ₹12,000 | 10,900 ₹10,900 |
| 2.02 | b) 100 amp, 415 V TPN Rewireable type Mainswitch | 1 | No. | 7,613 ₹7,613 Lowest | 8,000 ₹8,000 | 7,750 ₹7,750 |
| 2.03 | c) 100 Amp 4 way copper busbar chamber box by 16 SWG sheet steel enclosure including porcelain chair etc . With painting complete as per direction of EIC. | 1 | No. | 6,322 ₹6,322 Lowest | 6,700 ₹6,700 | 6,350 ₹6,350 |
| 2.04 | d) 25 sqmm, 3.5 core pvc insulated 1.1 KV grade, Aluminium Armoured Cable.
(@20mtr. for each Pump House) | 20 | Mtr. | 349 ₹6,980 Lowest | 360 ₹7,200 | 405 ₹8,100 |
| 3.00 | Making brick built foundation with supplying of all required materials suitable for the above voltage stabilizer by (4:1) cement mortar including holding down foundation bolts and plaster with neat cement finish, sloping all complete as per direction of EIC. | 1 | Item | 5,000 ₹5,000 Lowest | 6,000 ₹6,000 | 5,100 ₹5,100 |
| 4.00 | Fitting , fixing of change over switch, Busbar chamber and main switch as mentioned in item no. 2. (a) to (C) on the iron angle frame of suitable size fixed at suitable position on wall by supplying all necessary fixing materials all complete as per direction of EIC. | 1 | Item | 1,045 ₹1,045 Lowest | 1,200 ₹1,200 | 1,090 ₹1,090 |
| 5.00 | Installation of the above voltage stabilizer as in item no.1 on the foundation including making all connection complete as per direction of EIC. | 1 | Item | 5,000 ₹5,000 Lowest | 6,000 ₹6,000 | 5,150 ₹5,150 |
| 6.00 | Drawing & connection of cable on wall as in item no. 2.(d) & all connection complete with all equipment as per requirement & as per direction of EIC.
(@20mtr. for each Pump House) | 20 | Mtr. | 62 ₹1,240 Lowest | 65 ₹1,300 | 89 ₹1,780 |
Tender Value
₹2.2 L
EMD Value
₹4,548
Closing Date
18 Oct 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, NMD, PHE DTE.
Office of the Executive Engineer, Northern Mechanical Division Public Health Engineering Directorate Sukanta Sarani, Paresh Nagar, Sevoke Road, Siliguri - 734001, District- Jalpaiguri
Supply, delivery and installation of Servo Motor operated Copper wound line voltage corrector under PURBA SALBARI (Reju) WS Scheme at TW No. III in the dist. of Jalpaiguri under Northern Mechanical Division, P.H. Engineering Dte.
2022_PHED_410586_8
WBPHED/EE/NMD/NIeT- 19 OF 2022-2023
Open Tender
MECHANICAL
Item Rate
21 days
PURBA SALBARI
Please refer Tender documents.
4 documents required · 4 mandatory
₹4,548
Yes
9 Feb 2023
27 Sept 2022
20 Oct 2022
11 Oct 2022
18 Oct 2022
11 Oct 2022
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.22 MB
Tendernotice_2.pdf
PDF • 0.68 MB
BOQ_808103.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .