Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹2 Cr
EMD Value
₹10 L
Closing Date
16 Feb 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Medial Superintendent,
surgical implants P.D.U. Hospital, Rajkot (Part- 3 of 6)
267775
2026-2028
Open
Health
Supply
Rajkot
4 documents required · 2 mandatory · 2 optional
₹15,000
Medical Superintendent, P.D.U. Hospital, Rajkot ( Tender fee common for (Part- 1 of 6) )
₹10 L
23 Jan 2026
23 Jan 2026
23 Jan 2026
16 Feb 2026
23 Jan 2026
## Neuro Implants 15
Sr. No. Item Name Item Specification
701 Tit plate with gape1.5MMX 2H,3H,4H,5H,6H NA
702 Tit plate without gape1.5MMX 2H,3H,4H,5H,6H NA
703 plate with gape1.5MMX 2H,3H,4H,5H,6H NA
704 plate without gape1.5MMX 2H,3H,4H,5H,6H NA
705 plate with gape2.0MMX 2H,3H,4H,5H,6H NA
706 plate without gape2.0 MMX 2H,3H,4H,5H,6H NA
707 IMF screw 2x8mm,10mm NA
708 Tit IMF screw 2x8mm,10mm NA
709 Self Holding screw driver 1.5mm NA
710 Self Holding screw driver 2.0mm NA
711 Hybrid Archbar NA
712 Tit Monoaxial screw 5.5mmx30mm to 50mm NA
713 Tit Monoaxial screw 6.5mmx30mm to 50mm NA
714 Tit Polyaxial screw 5.5mmx30mm to 50mm NA
715 Tit Polyaxial screw 6.5mmx30mm to 50mm NA
716 Tit Reduction screw 5.5mmx30mm to 50mm NA
717 Tit Reduction screw 6.5mmx30mm to 50mm NA
718 Tit Dual thread Poly screw 5.5mmx30mm to 50mm NA
719 Tit Dual thread Poly screw 6.5mmx30mm to 50mm NA
721 TIT TRIPLLE THRED POLY AXIAL SCREW 6 mm NA
722 TIT TRIPPLE THRED REDUCTION SCREW 6mm NA
723 TIT ROD FOR COMPETIBLE TO TRIPPLE THREAD SCREW NA
724 Tit transversal connecter assembly NA
725 Tit Banana Cage NA
726 Tit Straight Cage NA
727 Tit Cervicle cage NA
728 Posterior cervicle screw 3.5mmx14mm to 26mm NA
729 Posterior cervicle screw 4.0mmx14mm to 26mm NA
730 Posterior cervicleTit Rod 3.5mmx 40mm to 130mm NA
731 Occipital cervicle middle fixation plate Medium NA
732 Occipital cervicle middle fixation plate Large NA
733 Occipital plate screw 4.0mmx10 to 20mm NA
734 Occipital plate screw 4.5mmx10 to 20mm NA
735 Cervicle lateral mass screw 3.5mmx12mm NA
736 Cervicle lateral mass screw 3.5mmx14mm NA
737 Cervicle lateral mass screw 3.5mmx16mm NA
738 Cervicle lateral mass screw 3.5mmx18mm NA
739 Cervicle lateral mass connection rod NA
740 inner connector for lateral mass construction NA
741 CTL -Expandable Cage NA
742 CTL- Expandable Cage, Locking Screw NA
743 Straight Plate, 2 Hole, L 16 mm, 0.6 thk NA
744 Straight Plate, 4 Hole, L 21 mm, 0.6 thk NA
745 Adaption Plate, 12 Hole, L 53 mm, 0.6 thk NA
746 Arc Shaped Plate, 06 Hole, L 29 mm, 0.6 thk NA
747 Arc Shaped Plate, 08 Hole, L 36 mm, 0.6 thk NA
748 Y Plate, 5 Hole, L 20 mm, 0.6 thk NA
749 Double Y Plate, 6 Hole, L 20 mm, 0.6 thk NA
750 X Plate, 4 Hole, L 10 mm, 0.6 thk NA
## Neuro Implants 16
Sr. No. Item Name Item Specification
751 T Plate, 7 Hole, L 25 mm, 0.6 thk -
752 Oblique L Plate 4 Hole, L 17 mm, 0.6 thk, Right -
753 Oblique L Plate 4 Hole, L 17 mm, 0.6 thk, Left -
754 Oblique L Plate 5 Hole, L 21 mm, 0.6 thk, Right -
755 Oblique L Plate 5 Hole, L 21 mm, 0.6 thk, Left -
756 Oblique L Plate 7 Hole, L 27 mm, 0.6 thk, Right -
757 Oblique L Plate 7 Hole, L 27 mm, 0.6 thk, Left -
758 Cortex Screw, ø 1.5mm self-Drilling, L 3.5 mm -
759 Cortex Screw, ø 1.5mm self-Drilling, L 4 mm -
760 Cortex Screw, ø 1.5mm self-Drilling, L 5 mm -
761 Cortex Screw, ø 1.5mm self-tapping, L 3.5 mm -
762 Cortex Screw, ø 1.5mm self-tapping, L 4 mm -
763 Cortex Screw, ø 1.5mm self-tapping, L 5 mm -
764 Cortex Screw, ø 1.8mm self-tapping, L 3.5 mm -
765 Cortex Screw, ø 1.8mm self-tapping, L 5 mm -
766 Stand Alone Cage , 6 mm WITH 4 LOCKING HOLES -
767 Stand Alone Cage , 7 mm WITH 4 LOCKING HOLES -
768 Stand Alone Cage , 8 mm WITH 4 LOCKING HOLES -
769 Stand Alone Cage , 9 mm WITH 4 LOCKING HOLES -
770 Stand Alone Cage , 10 mm WITH 4 LOCKING HOLES -
771 Ø3.0mm Stand Alone locking Screw L-12 mm -
772 Ø3.0mm Stand Alone locking Screw L-14 mm -
773 Ø3.0mm Stand Alone locking Screw L-16 mm -
774 Ø3.0mm Stand Alone locking Screw L-18 mm -
775 ø6.2mm Poly Axial Screw TITANIUM -
776 ø6.2mm Reduction Poly Axial Screw TITANIUM -
777 ø5.7mm Rod for poly and reduction screw 6.2 mm -
778 Cross Link (34 - 42) connector -
779 Driving Unit with 200 W Motor, Stand Base, Foot Control, on off WITH CDSCO, ISO, USFDA, EN 60601-1 APPROVED COMPANY
780 switch with fuse, WITH CDSCO, ISO, USFDA, EN 60601-1 APPROVED COMPANY
781 Flexible shaft of 1.5 mts WITH CDSCO, ISO, USFDA, EN 60601-1 APPROVED COMPANY
782 Craniotome Handpiece with anchor WITH CDSCO, ISO, USFDA, EN 60601-1 APPROVED COMPANY
783 Perforator Handpiece, WITH CDSCO, ISO, USFDA, EN 60601-1 APPROVED COMPANY
784 Cranitome Cutters WITH CDSCO, ISO, USFDA, EN 60601-1 APPROVED COMPANY
785 Perforator Cutter (12 mm WITH CDSCO, ISO, USFDA, EN 60601-1 APPROVED COMPANY
786 Perforator Cutter (10 mm WITH CDSCO, ISO, USFDA, EN 60601-1 APPROVED COMPANY
787 Perforator Cutter (8 mm WITH CDSCO, ISO, USFDA, EN 60601-1 APPROVED COMPANY
788 MIS-II Poly axial pedicle screw, ø6.0 -
789 MIS-II Contoured rod, ø5.5, -
790 MIS-II Straight rod, ø5.5 -
791 Ø12 Expandable Cervical Cage With Plate -
792 Ø14 Expandable Cervical Cage With Plate -
793 Colorado Microdissection Needle 3MM/4MM USFDA certificate
794 1.7 mm Screwdriver Handle USFDA certificate
795 2.2 mm Screwdriver Handle USFDA certificate
796 Tap Handle USFDA certificate
797 Straight Plate, 14 Holes, 1.4 mm Thick USFDA certificate
798 Straight Plate, 21 Holes, 1.4 mm Thick USFDA certificate
799 Straight Plate, 2 x 21 Holes, 1.4 mm Thick USFDA certificate
800 Straight Plate, 2 x 21 Holes, 0.5 mm Thick USFDA certificate
## Neuro Implants 17
Sr. No. Item Name Item Specification
801 Straight Plate, 3 x 21 Holes, 0.5 mm Thick USFDA certificate
802 Delta System, Ladder Plate, 2x 5 Holes USFDA certificate
803 Ds,Resorb Straight Plt 14 Hole USFDA certificate
804 Mesh, 55 x 55 x 1.0 mm USFDA certificate
805 Mesh, 55 x 55 x 1.4 mm USFDA certificate
806 Delta System, Mesh, 55 X 55mm USFDA certificate
807 Delta Implant USFDA certificate
808 Delta System, 1.7 X 4mm Screw, Pkg. 10 USFDA certificate
809 Delta System, 1.7 X 5mm Screw, Pkg. 10 USFDA certificate
810 Delta System1.7 X 3 Mm, Pkg. 4 USFDA certificate
811 Delta System1.7 X 4 Mm, Pkg. 4 USFDA certificate
812 Delta System1.7 X 5 Mm, Pkg. 4 USFDA certificate
813 TITAN Cranial - Temporal - Left - 130mm x 130mm x3mm USFDA certificate
814 TITAN Cranial - Temporal - Right - 130mm x 130mm x 3mm USFDA certificate
815 TITAN Cranial Curve 39mm x 48mm USFDA certificate
816 TITAN Cranial Curve - BARRIER 39mm x 48mm USFDA certificate
817 Cranial Hemisphere - Right - 100mm x 160mm x 4mm USFDA certificate
818 Cranial Hemisphere - Left - 100mm x 160mm x 4mm USFDA certificate
819 Cranial Hemisphere - Right - 133mm x 160mm x 6mm USFDA certificate
820 Cranial Hemisphere - Left - 133mm x 160mm x 6mm USFDA certificate
821 Cranial Dome - 150mm x 180mm x 4mm USFDA certificate
822 Cranial Dome - 150mm x 180mm x 6mm USFDA certificate
823 Transsphenoidal Sellar Implant - 20mm x 20mm x 2.5mm x 0.45mm USFDA certificate
824 Transsphenoidal Sellar Implant - BARRIER - Large - 40mm x 40mm x 2.5mm x 0.73mm USFDA certificate
825 Mastoid Implant - Small - 35mm x 45mm x 1.0mm USFDA certificate
826 Mastoid Implant Left - 57mm x 56mm x 1.5mm USFDA certificate
827 Mastoid Implant Right - 57mm x 56mm x 1.5mm USFDA certificate
828 Self Drilling AXS SCREWS 1.5X3MM USFDA certificate
829 Self Drilling AXS SCREWS 1.5X4MM USFDA certificate
830 Self Drilling AXS SCREWS 1.5X5MM USFDA certificate
831 PLATE, RIGID, 2 HOLE, BAR 12MM USFDA certificate
832 LOW PROFILE PLATE, 2 HOLE, BAR 16MM USFDA certificate
833 LOW PROFILE X-PLATE, 4 HOLE USFDA certificate
834 LOW PROFILE 3-D BOX PLATE, 2X2 HOLE USFDA certificate
835 LOW PROFILE BURR HOLE COVER PLATE 7MM USFDA certificate
836 LOW PROFILE BURR HOLE COVER PLATE 10 MM USFDA certificate
837 LOW PROFILE BURR HOLE COVER PLATE 14MM USFDA certificate
838 LOW PROFILE BURR HOLE COVER PLATE 20MM USFDA certificate
839 MICRO TITANIUM MESH, 120X120X0.1MM USFDA certificate
840 MICRO TITANIUM MESH, 120X60X0.1MM USFDA certificate
841 MICRO TITANIUM MESH, 60X60X0.1MM USFDA certificate
842 MICRO TITANIUM MESH, 120X120X0.2MM USFDA certificate
843 TITANIUM MICRO, 120X60X0.2MM USFDA certificate
844 MICRO TITANIUM MESH, 60X60X0.2MM USFDA certificate
845 DYNAMIC MESH MALLABLE FOR 1.5/1.7 40*40/.3MM USFDA certificate
846 DYNAMIC MESH MALLABLE FOR 1.5/1.7 120*120/.3MM USFDA certificate
847 DYNAMIC MESH MALLABLE FOR 1.5/1.7/90*90 /.3MM USFDA certificate
848 DYNAMIC MESH STD FOR 1.5/1.7MM 120*120/.6MM USFDA certificate
849 DYNAMIC MESH STD FOR 1.5/1.7MM/90*90/.6MM USFDA certificate
850 DYNAMIC MESH STD FOR 1.5/1.7MM /200*200/.6MM USFDA certificate
## Neuro Implants 18
Sr. No. Item Name Item Specification
851 MESH PRE-FORMED, f. 1.7/1.9MM SCREWS, 120x120x0.6MM USFDA certificate
852 MESH PRE-FORMED, F. 1.7/1.9MM SCREWS, 90x90x0.6MM USFDA certificate
853 MESH PRE-FORMED, F. 1.7/1.9MM SCREWS, 190x140x0.6MM USFDA certificate
854 Dynamic mesh - malleable - small 40x40x0.3mm USFDA certificate
855 Dynamic mesh - malleable - medium 90x90x0.3mm USFDA certificate
856 Dynamic mesh - malleable - large 120x120x0.3mm USFDA certificate
857 Dynamic mesh - standard - small 40x40x0.6mm USFDA certificate
858 Dynamic mesh - standard - medium 90x90x0.6mm USFDA certificate
859 Dynamic mesh - standard - large 120x120x0.6mm USFDA certificate
860 Dynamic mesh - standard - X-large 200x200x0.6mm USFDA certificate
861 Dynamic mesh - stiff - medium 90x90x0.8mm USFDA certificate
862 Dynamic mesh - stiff - large 120x120x0.8mm USFDA certificate
863 Dynamic mesh - stiff - X-large 200x200x0.8mm USFDA certificate
864 Hybrid mesh - malleable - small 60x60x0.3mm USFDA certificate
865 Hybrid mesh - malleable - medium 90x90x0.3mm USFDA certificate
866 Hybrid mesh - malleable - large 120x120x0.3mm USFDA certificate
867 Pre-form mesh, standard - medium 90x90x0.6mm USFDA certificate
868 Pre-form mesh, standard - large 120x120x0.6mm USFDA certificate
869 Pre-form mesh, standard - XL 190x140x0.6mm USFDA certificate
870 Dog-bone plate, 2-hole rigid USFDA certificate
871 Dog-bone plate, 2-hole, 16mm bar USFDA certificate
872 Pre-form mesh, right,17.5x12,8cm; T:1mm USFDA certificate
873 Pre-form mesh, left,17.5x12,8cm; T:1mm USFDA certificate
874 Round malleable (0.3mm), small USFDA certificate
875 Round malleable (0.3mm) Medium USFDA certificate
876 Round rigid (0.4mm), large USFDA certificate
877 Translabyrinthine malleable (0.3mm), small USFDA certificate
878 Translabyrinthine malleable (0.3mm), large USFDA certificate
879 Temporal malleable (0.3mm) USFDA certificate
880 Suboccipital malleable(0.3mm), small USFDA certificate
881 Suboccipital rigid (0.4mm), large USFDA certificate
882 Burr hole cover, 7mm, with USFDA certificate
883 Burr hole cover, 10mm, with USFDA certificate
884 Burr hole cover, 14mm, with USFDA certificate
885 Burr hole cover, 20mm, with USFDA certificate
886 Burr hole cover, 24mm, with USFDA certificate
887 Shunt burr hole cover, 14mm, USFDA certificate
888 Shunt burr hole cover, 20mm, USFDA certificate
889 Plates;-1.2 Upper-Face Micro Fixation Module Plates and screws should have USFDA certificate
890 Plates;-2.0 Mini-Plating Module Plates and screws should have USFDA certificate
891 Plates;-1.7 Mid-Face Mini Fixation Module Plates and screws should have USFDA certificate
892 Plates;-2.0/2.3 Mandible Fracture Fixation Module Plates and screws should have USFDA certificate
893 Bacterial Resistance Hydrocyphalus Shunt System Ventriculo Peritoneal High Pressure with Bacterial. -
894 Bacterial Resistance Hydrocyphalus Shunt System Ventriculo Peritoneal Medium Pressure with Bacterial. -
895 Bacterial Resistance Hydrocyphalus Shunt System Ventriculo Peritoneal Low Pressure with Bacterial. -
896 Hydrocephalus shunt system: Dome Valve reservoir with 90cm. Radio-opaque distal part one 15cm. ventricular part and two straignt connector. High Pressure. -
897 Hydrocephalus shunt system:Dome Valve reservoir with 90cm. Radio-opaque distal part one 15cm. ventricular part and two straignt connector. Medium Pressure. -
898 Hydrocephalus shunt system:Dome Valve reservoir with 90cm. Radio-opaque distal part one 15cm. ventricular part and two straignt connector. Law Pressure. -
899 Hydrocephalus shunt system:Antibaterial Dome Valve reservoir with 90cm. Radio-opaque distal part one 15cm. ventricular part and two straignt connector. Law Pressure. -
900 Hydrocephalus shunt system:Anibacterial Dome Valve reservoir with 90cm. Radio-opaque distal part one 15cm. ventricular part and two straignt connector. High Pressure. -
## Neuro Implants 19
Sr. No. Item Name Item Specification
901 Hydrocephalus shunt system:Antibacterial Dome Valve reservoir with 90cm. Radio-opaque distal part one 15cm. ventricular part and two straignt connector. Medium Pressure. -
902 Permanent Standard Aneurysm clip Straight Blade length 7mm and Closing force 150g The aneurysm clip should be made of Cobalt alloy, The clip should ne MRI safe up to 3 Tesla, The clip should have box lock joint to avoid Scissoring affect, The blade profile should have pyramid like impression. It should be atraumatic, The clip should ensure even pressure on the complete blade surface, Also Need the blades of the T-Bar Clip are oriented in a 90° (respectively 45°) angle to the axis of the spring plane resulting in a T-like clip form, Each clip should have individual serial no. to ensure complete tracking of manufacturing process, material, closing force, sterilization process. The clip should be supplied in sterile pack, The Package of clip should mention article no, expiry date, closing force, The clip should be colour coded, It should be supplied with sterilization tray with detachable marking showing the clip article no and clip design.
903 Permanent Standard Aneurysm clip Straight Blade length 9mm and Closing force 180g The aneurysm clip should be made of Cobalt alloy, The clip should ne MRI safe up to 3 Tesla, The clip should have box lock joint to avoid Scissoring affect, The blade profile should have pyramid like impression. It should be atraumatic, The clip should ensure even pressure on the complete blade surface, Also Need the blades of the T-Bar Clip are oriented in a 90° (respectively 45°) angle to the axis of the spring plane resulting in a T-like clip form, Each clip should have individual serial no. to ensure complete tracking of manufacturing process, material, closing force, sterilization process. The clip should be supplied in sterile pack, The Package of clip should mention article no, expiry date, closing force, The clip should be colour coded, It should be supplied with sterilization tray with detachable marking showing the clip article no and clip design.
904 Permanent Standard Aneurysm clip Straight Blade length 11mm and Closing force 180g The aneurysm clip should be made of Cobalt alloy, The clip should ne MRI safe up to 3 Tesla, The clip should have box lock joint to avoid Scissoring affect, The blade profile should have pyramid like impression. It should be atraumatic, The clip should ensure even pressure on the complete blade surface, Also Need the blades of the T-Bar Clip are oriented in a 90° (respectively 45°) angle to the axis of the spring plane resulting in a T-like clip form, Each clip should have individual serial no. to ensure complete tracking of manufacturing process, material, closing force, sterilization process. The clip should be supplied in sterile pack, The Package of clip should mention article no, expiry date, closing force, The clip should be colour coded, It should be supplied with sterilization tray with detachable marking showing the clip article no and clip design.
905 Permanent Standard Aneurysm clip Straight Blade length 15mm and Closing force 200g The aneurysm clip should be made of Cobalt alloy, The clip should ne MRI safe up to 3 Tesla, The clip should have box lock joint to avoid Scissoring affect, The blade profile should have pyramid like impression. It should be atraumatic, The clip should ensure even pressure on the complete blade surface, Also Need the blades of the T-Bar Clip are oriented in a 90° (respectively 45°) angle to the axis of the spring plane resulting in a T-like clip form, Each clip should have individual serial no. to ensure complete tracking of manufacturing process, material, closing force, sterilization process. The clip should be supplied in sterile pack, The Package of clip should mention article no, expiry date, closing force, The clip should be colour coded, It should be supplied with sterilization tray with detachable marking showing the clip article no and clip design.
906 Permanent Standard Aneurysm clip Straight Blade length 17mm and Closing force 200g The aneurysm clip should be made of Cobalt alloy, The clip should ne MRI safe up to 3 Tesla, The clip should have box lock joint to avoid Scissoring affect, The blade profile should have pyramid like impression. It should be atraumatic, The clip should ensure even pressure on the complete blade surface, Also Need the blades of the T-Bar Clip are oriented in a 90° (respectively 45°) angle to the axis of the spring plane resulting in a T-like clip form, Each clip should have individual serial no. to ensure complete tracking of manufacturing process, material, closing force, sterilization process. The clip should be supplied in sterile pack, The Package of clip should mention article no, expiry date, closing force, The clip should be colour coded, It should be supplied with sterilization tray with detachable marking showing the clip article no and clip design.
907 Permanent Standard Aneurysm Clip Curved Blade Length 6.5mm and closing force 150g The aneurysm clip should be made of Cobalt alloy, The clip should ne MRI safe up to 3 Tesla, The clip should have box lock joint to avoid Scissoring affect, The blade profile should have pyramid like impression. It should be atraumatic, The clip should ensure even pressure on the complete blade surface, Also Need the blades of the T-Bar Clip are oriented in a 90° (respectively 45°) angle to the axis of the spring plane resulting in a T-like clip form, Each clip should have individual serial no. to ensure complete tracking of manufacturing process, material, closing force, sterilization process. The clip should be supplied in sterile pack, The Package of clip should mention article no, expiry date, closing force, The clip should be colour coded, It should be supplied with sterilization tray with detachable marking showing the clip article no and clip design.
908 Permanent Standard Aneurysm Clip Curved Blade Length 8.3mm and closing force 180g The aneurysm clip should be made of Cobalt alloy, The clip should ne MRI safe up to 3 Tesla, The clip should have box lock joint to avoid Scissoring affect, The blade profile should have pyramid like impression. It should be atraumatic, The clip should ensure even pressure on the complete blade surface, Also Need the blades of the T-Bar Clip are oriented in a 90° (respectively 45°) angle to the axis of the spring plane resulting in a T-like clip form, Each clip should have individual serial no. to ensure complete tracking of manufacturing process, material, closing force, sterilization process. The clip should be supplied in sterile pack, The Package of clip should mention article no, expiry date, closing force, The clip should be colour coded, It should be supplied with sterilization tray with detachable marking showing the clip article no and clip design.
909 Permanent Standard Aneurysm Clip Curved Blade Length 10.2mm and closing force 180g The aneurysm clip should be made of Cobalt alloy, The clip should ne MRI safe up to 3 Tesla, The clip should have box lock joint to avoid Scissoring affect, The blade profile should have pyramid like impression. It should be atraumatic, The clip should ensure even pressure on the complete blade surface, Also Need the blades of the T-Bar Clip are oriented in a 90° (respectively 45°) angle to the axis of the spring plane resulting in a T-like clip form, Each clip should have individual serial no. to ensure complete tracking of manufacturing process, material, closing force, sterilization process. The clip should be supplied in sterile pack, The Package of clip should mention article no, expiry date, closing force, The clip should be colour coded, It should be supplied with sterilization tray with detachable marking showing the clip article no and clip design.
910 Permanent Standard T-BAR CLIP STD.PERM.JAWS 5MM 90DEG Closing force 150g The aneurysm clip should be made of Cobalt alloy, The clip should ne MRI safe up to 3 Tesla, The clip should have box lock joint to avoid Scissoring affect, The blade profile should have pyramid like impression. It should be atraumatic, The clip should ensure even pressure on the complete blade surface, Also Need the blades of the T-Bar Clip are oriented in a 90° (respectively 45°) angle to the axis of the spring plane resulting in a T-like clip form, Each clip should have individual serial no. to ensure complete tracking of manufacturing process, material, closing force, sterilization process. The clip should be supplied in sterile pack, The Package of clip should mention article no, expiry date, closing force, The clip should be colour coded, It should be supplied with sterilization tray with detachable marking showing the clip article no and clip design.
911 Permanent Standard Aneurysm Clip Straight with 3.5mm Fenestration blade length 4/9.1mm and closing force 150g The aneurysm clip should be made of Cobalt alloy, The clip should ne MRI safe up to 3 Tesla, The clip should have box lock joint to avoid Scissoring affect, The blade profile should have pyramid like impression. It should be atraumatic, The clip should ensure even pressure on the complete blade surface, Also Need the blades of the T-Bar Clip are oriented in a 90° (respectively 45°) angle to the axis of the spring plane resulting in a T-like clip form, Each clip should have individual serial no. to ensure complete tracking of manufacturing process, material, closing force, sterilization process. The clip should be supplied in sterile pack, The Package of clip should mention article no, expiry date, closing force, The clip should be colour coded, It should be supplied with sterilization tray with detachable marking showing the clip article no and clip design.
912 Permanent Standard Aneurysm Clip Straight with 3.5mm Fenestration blade length 5/10.1mm and closing force 150g The aneurysm clip should be made of Cobalt alloy, The clip should ne MRI safe up to 3 Tesla, The clip should have box lock joint to avoid Scissoring affect, The blade profile should have pyramid like impression. It should be atraumatic, The clip should ensure even pressure on the complete blade surface, Also Need the blades of the T-Bar Clip are oriented in a 90° (respectively 45°) angle to the axis of the spring plane resulting in a T-like clip form, Each clip should have individual serial no. to ensure complete tracking of manufacturing process, material, closing force, sterilization process. The clip should be supplied in sterile pack, The Package of clip should mention article no, expiry date, closing force, The clip should be colour coded, It should be supplied with sterilization tray with detachable marking showing the clip article no and clip design.
913 Permanent Standard Aneurysm Clip Straight with 5.0mm Fenestration Blade length 3/9.8mm and closing force 150g The aneurysm clip should be made of Cobalt alloy, The clip should ne MRI safe up to 3 Tesla, The clip should have box lock joint to avoid Scissoring affect, The blade profile should have pyramid like impression. It should be atraumatic, The clip should ensure even pressure on the complete blade surface, Also Need the blades of the T-Bar Clip are oriented in a 90° (respectively 45°) angle to the axis of the spring plane resulting in a T-like clip form, Each clip should have individual serial no. to ensure complete tracking of manufacturing process, material, closing force, sterilization process. The clip should be supplied in sterile pack, The Package of clip should mention article no, expiry date, closing force, The clip should be colour coded, It should be supplied with sterilization tray with detachable marking showing the clip article no and clip design.
914 Permanent Standard Aneurysm Clip Straight with 5.0mm Fenestration Blade length 4/10.8mm and closing force 150g The aneurysm clip should be made of Cobalt alloy, The clip should ne MRI safe up to 3 Tesla, The clip should have box lock joint to avoid Scissoring affect, The blade profile should have pyramid like impression. It should be atraumatic, The clip should ensure even pressure on the complete blade surface, Also Need the blades of the T-Bar Clip are oriented in a 90° (respectively 45°) angle to the axis of the spring plane resulting in a T-like clip form, Each clip should have individual serial no. to ensure complete tracking of manufacturing process, material, closing force, sterilization process. The clip should be supplied in sterile pack, The Package of clip should mention article no, expiry date, closing force, The clip should be colour coded, It should be supplied with sterilization tray with detachable marking showing the clip article no and clip design.
915 Permanent Standard Aneurysm Clip Straight with 5.0mm Fenestration Blade length 5/11.8mm and closing force 150g The aneurysm clip should be made of Cobalt alloy, The clip should ne MRI safe up to 3 Tesla, The clip should have box lock joint to avoid Scissoring affect, The blade profile should have pyramid like impression. It should be atraumatic, The clip should ensure even pressure on the complete blade surface, Also Need the blades of the T-Bar Clip are oriented in a 90° (respectively 45°) angle to the axis of the spring plane resulting in a T-like clip form, Each clip should have individual serial no. to ensure complete tracking of manufacturing process, material, closing force, sterilization process. The clip should be supplied in sterile pack, The Package of clip should mention article no, expiry date, closing force, The clip should be colour coded, It should be supplied with sterilization tray with detachable marking showing the clip article no and clip design.
916 Temporary Standard Aneurysm clip Straight blade length 9mm and closing force 70g The aneurysm clip should be made of Cobalt alloy, The clip should ne MRI safe up to 3 Tesla, The clip should have box lock joint to avoid Scissoring affect, The blade profile should have pyramid like impression. It should be atraumatic, The clip should ensure even pressure on the complete blade surface, Also Need the blades of the T-Bar Clip are oriented in a 90° (respectively 45°) angle to the axis of the spring plane resulting in a T-like clip form, Each clip should have individual serial no. to ensure complete tracking of manufacturing process, material, closing force, sterilization process. The clip should be supplied in sterile pack, The Package of clip should mention article no, expiry date, closing force, The clip should be colour coded, It should be supplied with sterilization tray with detachable marking showing the clip article no and clip design.
917 Temporary Standard Aneurysm clip Curved blade length 8.4mm and closing force 70g The aneurysm clip should be made of Cobalt alloy, The clip should ne MRI safe up to 3 Tesla, The clip should have box lock joint to avoid Scissoring affect, The blade profile should have pyramid like impression. It should be atraumatic, The clip should ensure even pressure on the complete blade surface, Also Need the blades of the T-Bar Clip are oriented in a 90° (respectively 45°) angle to the axis of the spring plane resulting in a T-like clip form, Each clip should have individual serial no. to ensure complete tracking of manufacturing process, material, closing force, sterilization process. The clip should be supplied in sterile pack, The Package of clip should mention article no, expiry date, closing force, The clip should be colour coded, It should be supplied with sterilization tray with detachable marking showing the clip article no and clip design.
918 Temporary Standard Aneurysm clip Curved blade length 6.7mm and closing force 70g The aneurysm clip should be made of Cobalt alloy, The clip should ne MRI safe up to 3 Tesla, The clip should have box lock joint to avoid Scissoring affect, The blade profile should have pyramid like impression. It should be atraumatic, The clip should ensure even pressure on the complete blade surface, Also Need the blades of the T-Bar Clip are oriented in a 90° (respectively 45°) angle to the axis of the spring plane resulting in a T-like clip form, Each clip should have individual serial no. to ensure complete tracking of manufacturing process, material, closing force, sterilization process. The clip should be supplied in sterile pack, The Package of clip should mention article no, expiry date, closing force, The clip should be colour coded, It should be supplied with sterilization tray with detachable marking showing the clip article no and clip design.
919 Bayonet Aneurysm clip applicator for Standard Clip, Straight, Working Length-110mm. The clip applicator should be made of high grade stainless steel/Titanium. The quality of steel/titanium should comply with the DIN standards, It should be of high quality and precision. It should be light weight, strong and durable, It should be non-magnetic. All instruments should be autoclavable, The manufacturer should have a direct repair facility available in India, All clip applicator should be autoclavable at 134deg, It should be supplied with sterilization tray for clip applicator, Instruments should meet the International Certification as per DIN EN ISO 13845:2001, It should have TUV certificate for manufacturer with details of manufacturing facility, The manufacturer should have service facility in India.
920 Bayonet Aneurysm clip applicator for Standard Clip, 15deg angled, Working Length-110mm. The clip applicator should be made of high grade stainless steel/Titanium. The quality of steel/titanium should comply with the DIN standards, It should be of high quality and precision. It should be light weight, strong and durable, It should be non-magnetic. All instruments should be autoclavable, The manufacturer should have a direct repair facility available in India, All clip applicator should be autoclavable at 134deg, It should be supplied with sterilization tray for clip applicator, Instruments should meet the International Certification as per DIN EN ISO 13845:2001, It should have TUV certificate for manufacturer with details of manufacturing facility, The manufacturer should have service facility in India.
921 Bayonet Aneurysm clip applicator for Standard Clip, Straight, Working Length-90mm. The clip applicator should be made of high grade stainless steel/Titanium. The quality of steel/titanium should comply with the DIN standards, It should be of high quality and precision. It should be light weight, strong and durable, It should be non-magnetic. All instruments should be autoclavable, The manufacturer should have a direct repair facility available in India, All clip applicator should be autoclavable at 134deg, It should be supplied with sterilization tray for clip applicator, Instruments should meet the International Certification as per DIN EN ISO 13845:2001, It should have TUV certificate for manufacturer with details of manufacturing facility, The manufacturer should have service facility in India.
922 Bayonet Aneurysm clip applicator for Standard Clip, 15deg angled, Working Length-90mm. The clip applicator should be made of high grade stainless steel/Titanium. The quality of steel/titanium should comply with the DIN standards, It should be of high quality and precision. It should be light weight, strong and durable, It should be non-magnetic. All instruments should be autoclavable, The manufacturer should have a direct repair facility available in India, All clip applicator should be autoclavable at 134deg, It should be supplied with sterilization tray for clip applicator, Instruments should meet the International Certification as per DIN EN ISO 13845:2001, It should have TUV certificate for manufacturer with details of manufacturing facility, The manufacturer should have service facility in India.
923 Bayonet Aneurysm clip applicator for Standard Clip, Straight, Working Length-50mm. The clip applicator should be made of high grade stainless steel/Titanium. The quality of steel/titanium should comply with the DIN standards, It should be of high quality and precision. It should be light weight, strong and durable, It should be non-magnetic. All instruments should be autoclavable, The manufacturer should have a direct repair facility available in India, All clip applicator should be autoclavable at 134deg, It should be supplied with sterilization tray for clip applicator, Instruments should meet the International Certification as per DIN EN ISO 13845:2001, It should have TUV certificate for manufacturer with details of manufacturing facility, The manufacturer should have service facility in India.
924 Non-bayonet Aneurysm clip applicator for Standard Clip, Straight, Total Length-175mm. The clip applicator should be made of high grade stainless steel/Titanium. The quality of steel/titanium should comply with the DIN standards, It should be of high quality and precision. It should be light weight, strong and durable, It should be non-magnetic. All instruments should be autoclavable, The manufacturer should have a direct repair facility available in India, All clip applicator should be autoclavable at 134deg, It should be supplied with sterilization tray for clip applicator, Instruments should meet the International Certification as per DIN EN ISO 13845:2001, It should have TUV certificate for manufacturer with details of manufacturing facility, The manufacturer should have service facility in India.
925 Bayonet Aneurysm Clip applicator with swivel tips and adjustable jaw, Working length 90mm. Should be supplied with adjusting Key. The clip applicator should be made of high grade stainless steel/Titanium. The quality of steel/titanium should comply with the DIN standards, It should be of high quality and precision. It should be light weight, strong and durable, It should be non-magnetic. All instruments should be autoclavable, The manufacturer should have a direct repair facility available in India, All clip applicator should be autoclavable at 134deg, It should be supplied with sterilization tray for clip applicator, Instruments should meet the International Certification as per DIN EN ISO 13845:2001, It should have TUV certificate for manufacturer with details of manufacturing facility, The manufacturer should have service facility in India.
926 Clamp size, 11mm, (Box of 12) Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible. Implant must have integrated grasping jaw mechanism for shorter application time. All the instruments should be supplied from single manufacturer.
927 Clamp size, 16mm, (Box of 12) Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible. Implant must have integrated grasping jaw mechanism for shorter application time. All the instruments should be supplied from single manufacturer.
928 Clamp size, 20mm, (Box of 12) Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible. Implant must have integrated grasping jaw mechanism for shorter application time. All the instruments should be supplied from single manufacturer.
929 Clamp applier, non-dismountable, with automatic strain relief Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible. Implant must have integrated grasping jaw mechanism for shorter application time. All the instruments should be supplied from single manufacturer.
930 Holding forcep Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible. Implant must have integrated grasping jaw mechanism for shorter application time. All the instruments should be supplied from single manufacturer.
931 Pin Cutting instruments Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible. Implant must have integrated grasping jaw mechanism for shorter application time. All the instruments should be supplied from single manufacturer.
932 Forcep to remove the clamps Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible. Implant must have integrated grasping jaw mechanism for shorter application time. All the instruments should be supplied from single manufacturer.
933 Storage tray for all instruments Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible. Implant must have integrated grasping jaw mechanism for shorter application time. All the instruments should be supplied from single manufacturer.
934 Bottom for ½ storage tray, height 90mm Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible. Implant must have integrated grasping jaw mechanism for shorter application time. All the instruments should be supplied from single manufacturer.
935 ½ lid for storage container Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible. Implant must have integrated grasping jaw mechanism for shorter application time. All the instruments should be supplied from single manufacturer.
936 Sterile instrument oil should be used to lubricate the instruments Titanium Clamps should be used for bone flaps and bone fragments in cranial closure, skull fracture surgery. Clamps should be MRI compatible. Implant must have integrated grasping jaw mechanism for shorter application time. All the instruments should be supplied from single manufacturer.
937 Applicator handle made up of aluminum with gun shaped to use disposable scalp fix/raney clips. Handle must be autoclavable and made up of aluminum Disposable cartridge should be used with reusable handle for • Easy handling & fast application • Atraumatic design • Good visibility and countability of the clips All the instruments should be supplied from single manufacturer.
938 Disposable and sterile Cartridge should have 10 clips in single magazine. Disposable cartridge should be used with reusable handle for • Easy handling & fast application • Atraumatic design • Good visibility and countability of the clips All the instruments should be supplied from single manufacturer.
939 Removing forcep Disposable cartridge should be used with reusable handle for • Easy handling & fast application • Atraumatic design • Good visibility and countability of the clips All the instruments should be supplied from single manufacturer.
940 DESMARRES Lid Retractor, 140 mm (5 1/2"), depth: 9 mm, width: 12 mm, non-sterile, reusable,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
941 DESMARRES Lid Retractor, 140 mm (5 1/2"), depth: 12 mm, width: 16 mm, non-sterile, reusable,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
942 KILLIAN SEPTUM SPECUL.ASEPTIC 56X7MM has-tage2,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
943 COTTLE Columella Clamp, serrated, 100 mm (4"),The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
944 JOSEPH Skin Hook, 160 mm (6 1/4"), 2 prongs, sharp, width: 6 mm, non-sterile, reusable,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
945 WALTER Retractor, double ended, 2 prongs, non-sterile, reusable,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
946 STEGMANN Areola/cookie cutter, toothed, 33 mm diam.,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
947 Areola/cookie cutter, toothed, 38 mm diam.,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
948 VOLKMANN Wound Retractor (With Prong), 220 mm (8 3/4"), 4 prongs, semi-sharp, depth: 8,500 mm, width: 19 mm, non-sterile, reusable,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
949 VOLKMANN Wound Retractor (With Prong), 220 mm (8 3/4"), 6 prongs, semi-sharp, depth: 8,500 mm, width: 29 mm, non-sterile, reusable,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
950 Vario Retractor, blade only, depth: 115 mm, width: 22 mm, non-sterile, reusable,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
## Neuro Implants 20
Sr. No. Item Name Item Specification
951 Vario Retractor, 280 mm (11"), handle w. cold light carrier, non-sterile, reusable,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
952 MASING Cartilage Slitting Knife, curved, 130 mm (5 1/8"),The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
953 HEYMANN-KNIGHT Nasal Scissors, angled, knee bent, blunt/blunt, 175 mm (6 7/8"),The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
954 GRAEFE Delicate Scissors (Iris Scissors), angled on flat, delicate pattern, blunt/blunt, 100 mm (4"),The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
955 COTTLE Tissue Forceps, bayonet-shaped, toothed, serrated, 140 mm (5 1/2"),The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
956 ADSON-BROWN Tissue Forceps, straight, toothed, 120 mm (4 3/4"),The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
957 JANSEN Dressing Forceps (Tweezers), straight, bayonet-shaped, serrated, 160 mm (6 1/4The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
958 COTTLE Wound Retractor, 140 mm (5 1/2"), depth: 10 mm, width: 12 mm, non-sterile, reusable,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
959 COTTLE Wound Retractor, 200 mm (7 7/8"), double ended, blunt, non-sterile, reusable,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
960 JOSEPH Skin Hook, 160 mm (6 1/4"), 2 prongs, sharp, width: 6 mm, non-sterile, reusable,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
961 COTTLE Skin Hook, 180 °, strongly curved, 160 mm (6 1/4"), 1 prong, sharp, non-sterile, reusable,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
962 WALTER Retractor, double ended, 2 prongs, non-sterile, reusable,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
963 HARTMANN-HALE NASAL SPECASEPSHRT155MM,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
964 NASAL SPECULUM COTTLE SI.2,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
965 NASAL SPECULUM COTTLE SI.4,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
966 COTTLE SEPTUM SPECULUM THIN-BLD 90X7MM,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
967 COTTLE Chisel, straight, 180 mm (7"), width: 4 mm,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
968 COTTLE Chisel, straight, 180 mm (7"), width: 7 mm,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
969 COTTLE Chisel, curved, 180 mm (7"), width: 6 mm,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
970 MASING Osteotome, curved to left, 175 mm (6 7/8"),The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
971 MASING Osteotome, curved to right, 175 mm (6 7/8"),The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
972 MASING Osteotome, straight, 175 mm (6 7/8"),The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
973 COTTLE Mallet, 185 mm (7 1/4"), diam. 30 mm, stainless steel, 320 g, 235 g,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
974 FREER Elevator, curved, 185 mm (7 1/4"), double ended, sharp/blunt, non-sterile, reusable,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
975 COTTLE Elevator, 205 mm (8"), double ended, graduated, blunt/blunt, non-sterile, reusable,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
976 COTTLE Elevator, curved, 200 mm (7 7/8"), double ended, sharp/sharp, non-sterile, reusable,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
977 Raspatory, non-sterile, reusable,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
978 FOMON Bone File, 215 mm (8 1/2"), double ended, serrated (cross), width: 6,50 mm, 7,50 mm,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
979 FOMON Bone Rasp, 215 mm (8 1/2"), double ended, toothed (fine coarse), width: 6,50 mm, 7,50 mm,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
980 BONE CRUSHER,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
981 WEIL-BLAKESELEY Rongeur, straight, 120 mm (4 3/4"), oval, fenestrated, width: 4,20 mm,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
982 WEIL-BLAKESELEY Rongeur, 140 °, upwards cutting, 115 mm (4 1/2"), oval, fenestrated, width: 4,20 mm,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
983 Osteotome, straight, 190 mm (7 1/2"), width: 2 mm,The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
984 WATSON Skin Graft Knife, 300 mm (12"),The gloss level of the surface finish is matt/brushed, RA: 0.20 – 0.30 um, or matt/glass bead matted, RA: 0.22 – 0.30 um. Laser engraving preferred, as well as individual, machine- readable encoding to allow individual instrument tracking. The matting process must be followed, verified, by effective, chemical passivation (see ASTM Designation: A 380-06, A 967). Corrosion resistance: acc. to DIN EN ISO 13402 -
985 Intracranial Pressure Monitoring System Ventricular sensor with Scull bolt The catheter should be inbuilt with micro sensor and ventricular catheter for the drainage of the CSF and monitor ICP at the same time., It should have 38cm clear ventricular catheter with preloaded stylet., The transducer should consists of a miniature strain gauge pressure sensor mounted in a titanium case at the tip of a 100cm flexible nylon tube., It should come with 7-guage tunneling trocar for placement., The information should be relayed electronically rather than hydrostatic or fiberoptics., It should be made of strain gauge mechanism, It should have high fidelity of greater than 10000Hz to facilitate excellent wave form analysis., The drift in ICP over 9 days period should be maximum of 1mmhg or less., The system should be capable of monitoring Ventricular ICP. It should be available with Scull bolt to reduce the movement of implanted sensor.
986 Vetriculo Peritoneal High Pressure shunt with antibiotic impregnated ventricular and petonial catheter Impregnated with Rifampicin and Clindamycin to avoid infection for 28 days
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SURGICAL IMPLANTS.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .