Executive Engineer(E/M)
OFFICE OF THE EXECUTIVE ENGINEER E/M DIVISION P.W.D.DEHRADUN
Replacement of fire alarm and detection system at Honble CM house Cantt. road Dehradun.
2026_pwd_99831_1
1577/Nivida dated 01/9/26
Open Tender
Electrical Works
Item Rate
270 days
Dehradun
Please refer tender documents
2 documents required · 2 mandatory
₹3,540
Executive Engineer, E/M Division PWD Dehradun
₹88,900
Dehradun
7 Sept 2026
7 Sept 2026
1 Oct 2026
7 Sept 2026
30 Sept 2026
7 Sept 2026
7 Sept 2026 - 14 Sept 2026
15 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. 2 LOOP | 2 | Nos | - | - |
| 2 | Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. | 2 | Nos | - | - |
| 3 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. | 189 | Nos | - | - |
| 4 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. | 13 | Nos | - | - |
| 5 | Supplying, installation, testing & commissioning of addressable fire control module complete as required. | 5 | Nos | - | - |
| 6 | Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required. | 3 | Nos | - | - |
| 7 | Supplying, installation, testing & commissioning of addressable Manual Call Point complete as required. | 26 | Nos | - | - |
| 8 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. | 26 | Nos | - | - |
| 9 | Supplying & laying of 2Cx1.5 sqmm fire alarm armoured cable,
600/1000V rated with annealed copper conductor having
XLPE insulation, steel wire armouring & FRLS outer sheath
in existing trench/ conduit or in surface complete as required. | 4,000 | metre | - | - |
| 10 | S/F of 25mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. | 1,400 | metre | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.53 MB
BOQ_117717.xls
BOQ • 0.33 MB
technicalbid.pdf
Tender Documents • 6.95 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .