Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹35.3 L+₹3.0 L (9.35%)Rejected-AOC | L2 | Rejected-AOC Become L2 | |
| 3 | L3₹35.9 L+₹3.6 L (11.1%)Rejected-AOC | L3 | Rejected-AOC Become L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted in eligible category | |
| 5 | Rejected-Technical VILL BAREGAON PO CHAK CHAKA BAZAR DIST BARPE | BARPETA | ASSAM | 781301 | - | Rejected-Technical Not enlisted in eligible category |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
21 Aug 2020, 6:00 pmClosed
GE SOUTH TEZPUR
GE SOUTH TEZPUR MISSION CHARALI
SPECIAL REPAIR TO BLDG NO T-29/32D,T-63, REPLACEMENT OF GEYSER AGAINST BER ITEMS ,CERTAIN LBW ,REV AND MINOR WORKS AT SAA UNDER GE (S) TEZPUR
2020_MES_363549_1
8519
Open Tender
Civil Works
Item Rate
240 days
GE SOUTH TEZPUR
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE SOUTH TEZPUR
₹80,000
Yes
22 Oct 2020
23 Jul 2020
24 Aug 2020
23 Jul 2020
21 Aug 2020
6 Aug 2020
Amount
B/R WORKS:- Taking down chowkats or frame with shutters (without taking off shutters from frame) exceeding 1.50 Sqm and not exceeding 4.0 Sqm each including dismantling of PCC bed block for hold fast all as directed.
Taking down chowkats or frame with shutters (without taking off shutters from frame) not exc. 1.5 sq. m each including dismantling of PCC bed block for hold fast all as directed.
Taking down shutters of any description n exc 1sq. m each all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thick above or below ground level all as directed.
Dismantling asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section(Framed work), in any position all as specified and directed.
Dismantling timber fillets, rails, posts, rafters,purlins, etc. under 40 sq. cm in section(Unframed work) , in any position all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails all as specified and directed.
Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc. all as directed.
Taking down cement plaster, of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water all as directed.
Taking down PVC(SWR) rain water pipe any size of dia not exceeding 110mm from wall /floor complete all as directed .
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to stores and rubbish off the premises all as directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil all as specified and directed.
Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth and getting out in soft/loose soil all as specified and directed.
Returning, filling in trenches including spreading, leveling watering and ramming in layers not exceeding 25cm all as directed.
Removing of surplus soil not exceeding 50 m and deposited where directed at a level not exceeding 1.50m above the starting point all as directed.
Material and labour for sand filling under floors or in foundation including watering and consolidation all as specified and directed.
Material and labour for hard core of gauge n.exc. 63 mm with broken stone or boulders, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete, all as specified and as directed.
Material and labour for providing Plain Cement Concrete (1:4:8) type D-2, (using 40 mm grade stone aggregate) as in foundation, filling and mass concrete complete, all as specified and directed.
Material and labour for providing Plain Cement Concrete (1:3:6) type C1 using 20mm graded aggregate as in bed block or hold fast all as specified and directed.
Material and labour for providing cement concrete Type B1 1:2:4 (20 mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed all as specified and directed.
Material and labour for brickwork with fly ash old size bricks built in cement mortar 1:6 , straight or curved on plan exc 6m mean radius, all as specified and directed.(Note:- (a) Fly ash bricks shall be burnt clay flyash building bricks as per IS- 13757.(b) The unit rates for work curved or polygonal on plan include for all extra cutting and extra waste in the body of the work. It shall be measured as mean length of wall. (c)Unit Rates are for bricks of class designation 75 (Kgf/cm2).
Material & labour weather boarding, clean sawn, thickness 20mm to 25 mm and wrought both sides and edges shot and chamfered (on exposed edges) complete all as specified and directed.
Material & labour second class hard-wood in scantlings timber fixed clean sawn complete all as specified and directed.
Material & labour second class hard-wood in Plain fillets.square,rectangular or triangular in section(Sectional area Exc 6 & n exc 13sq.cm), clean sawn, secured with nails or brads complete all as specified and directed.
Supply and fix pressed steel frames of size 105 mm x 60 mmx 1.6 mm with one or more rebates including necessary fixing lugs, hinges, lock strike, plate etc complete all as specified and directed
Supply and fix, factory made 30 mm thick, flush shutters, solid core construction, with block board core and plywood face panels commercial type on both sides all as specified and directed.
S&F small fittings using 2nd class hardwood such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles exc 200 cu. cm and n exc 500 cu. Cm complete all as specified and directed
Supply and fix steel ventilator with top hung shulter including hinges, steel peg stay, complete all as specified and directed
S & F composite door frame of size not less than 125x60mm made from 100% solid wood plastic complete (Single extended process) material with density not less than 780kg/cum & plastic wood complete as per manufacturer's instruction.
Supply and fix, 50 mm long butt hinges, medium weight, and cold rolled mild steel all as specified and directed.
Supply and fix in repair, 100 mm long butt hinges, medium weight, and cold rolled mild steel all as specified and directed.
Supply and fix , 100 mm long butt hinges, medium weight, and cold rolled mild steel all as specified and directed.
Supply and fix in repair , 200 mm long aluminum anodised barrel tower bolts of extruded section all as specified and directed
Supply and fix , 200 mm long aluminum anodised barrel tower bolts of extruded section all as specified and directed
Supply and fix, 150 mm extruded aluminum alloy handles, fabricated type, anodized all as specified and directed
Supply and fix, 300 mm long aluminum alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of steel, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy all as specified and directed.
Supply and fix in repars 20mm dia mild steel chromium plated curtain rods with brackets ,stop rollers etc complete all as directed.
Supply and fix, stainless steel wire cloth 0.36 nominal dia wire and average width aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Supply and fix, mild steelwork as in band, straps, hold fasts, gate hooks and pintle hinges, large hasps and staples, chains, sliding bolts, clamps, and similar small articles conforming to Fe-290(Gde E-165) all as specified and directed.
S & F framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 all as specified and directed.(Note:-(a) The unit rates include for riveting and/or welding as directed and fixing with screws, bolts, etc. complete).
S & F anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.(Note:-(a) The unit rates include for provision of PVC protected sheeting and its removal after fixing the frame work. (b) Weight of joining cleat shall be added to main frame. (c) Hinges, shutters and lugs shall be measured and paid for separately).
S & F anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.(Note:-(a) Glass and other filling material in panels shall be measured and paid for separately. (b) Area of opening shall be measured to the nearest 0.5 sq.cm. (c) The unit rates does not include for anodised aluminium hard wares as indicated, glazing clips, rubber packing, anodised aluminium snap on beading for fixing glass panes in frames. (d) Fixing of shutters with fittings shall be as per manufacturers instructions).
S & F 2nd class hard wood 35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); and fitted to chowkats complete all as specified and directed.(Note:-(a) The term ‘shutter’ covers all types of leaves and sashes in woodwork whether fixed, hung or sliding, such as for doors,windows, clerestorey windows, ventilators, fanlights,skylights, lantern & northlights louvered or venetianed shutters, cupboard fronts, framed and pannelled linings or dados and similar work. (b) The term ‘glazed shutter’ means shutter or part of shutter with panels divided into squares or rectangles with plain,chamfered, rounded or moulded sash bars and glazed with glass as indicated. (c) Circular shutters shall be measured as square and priced at twice the rate for straight work. Shutters with semi-circular or segmental head shall be measured in two parts, the rectangular portion and the upper curved portion, the latter being measured as square (overall width by height at centre) and priced at twice the rate for straight work. (d) No extra width or labour shall be measured for rebated and or splayed meeting stiles of door and window shutters. (e) Shutters with combination of two types (e.g. glazed or venetianed upper portion and pannelled lower portion)shall be measured in two portions. The dividing line for measurements shall be the centre of the rail separating the different portions.(f) All shutters shall be framed except / ledged and battened type and ledged, braced and battened type. (g) Wood work in built-in wardrobes, cupboards etc. shall be measured in detail under the appropriate items. (h) The rates include for : (1) Nails, screws, wedges and keys as required.(2) Hardwood or bamboo pins to framed joints.(3) Coating framed joints with glue before being put together.(4) Punching and clenching nails.(5) Planing on all sides unless described as clean sawn.(6) Providing shutters in one leaf or more leaves, as directed.(7) All extra work due to diminished stiles, if directed.(8) Sand papering to an even and smooth texture.(9) Fitting of shutters to chowkats (and fixing in the case of fixed shutters) and preparing for hanging, sliding,etc. All builder’s hardware including hinges, pivots,etc. shall be measured in addition, as ‘supplied and fixed’. (j) Glass or wire cloth, etc. in panels or sash squares shall be measured and paid separately.).
Supply and fix Steel work in tubular trusses and post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 all as specified and directed.
Material and labour for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strenght of 550 MPA as in roof covering/claddiing to wall, fixed with self tapping screws as specefied all as specefied and directed.
Material and labour for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strenght of 550 MPA as in roof covering /cladding to wall fixed with self tapping screws all as specefied and directed.
Material and labour for providing 40 mm thick cement concrete (1:2:4) type B1 using 20mm graded stone aggregate as in floors finished the surfaces even and rough to receive to topping layers all as specified.
Material and labour for providing 100 mm thick cement concrete (1:3:6) type C2 using 40 mm graded stone aggregate as in sub base of floor all as specified and directed.
Material and labour for providing 75 mm thick cement concrete (1:3:6) type C1 using 20 mm graded stone aggregate as in plinth protection surfaces finished even and smooth without using extra cement including making construction joint of not less than 15mm width x 75mm depth at interval of 1.5m and filled with bituminous filler comlete all as specified and directed.
Material and labour for 38mm width glass dividing strips, 3 mm thick and inserted in position,conform to design all as specified and directed.
Material and labour for Non - skid Ceramic Coloured tiles tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layers 15 mm thick in cement mortar (1:6) for laying floor finishes all as directed.
Material and labour for Non - skid Ceramic Coloured tiles tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in skirting /dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over rendering 10 mm thick in cement mortar (1:4) for laying floor finishes all as directed.
Material and labour glazed ceramic coloured tiles of size not less than 400mmx350mmx7 to 8 mm thick coloured tiles on vertical surfaces set and jointed in neat cement slurry @ 3 Kg/Sqm and pointed in white or coloured cement to match the existing surface complete all as specified and directed.
Material and labour for 20mm to 25mm thick machine cut Kota stone slab, flooring over cement screed base laid and jointed with gray cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed.
All as per item No56 here in before but on vertical surfaces skirting/dado/riserof steps.
Material and labour for Machine pressed precast conctete prepolished interlocking paver block, with grey cement and pigment (coloured) any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade pointed in neat cement slurry @ 3Kg/Sqm with grey cement and colour pigment complete all as specified and directed.
Material and labour for 15 mm thick rendering in cement mortar (1:4) on fair face of brick or concrete surface finished even and fair complete all as specified and directed.
Material and labour for 15 mm thick rendering in cement mortar (1:4) on fair face of brick or concrete surface finished even and fair including wire netting of galvanised steel wire 0.71mm dia and 12mm size of mesh fixed with tinned tacks of wire staples complete all as specified and directed.
Material and labour for 10 mm thick rendering in cement mortar (1:6) on fair face of brick or concrete surface finished even and fair all as specified and directed.
Material and labour for 10 mm thick rendering in cement mortar (1:6)on the ‘other’ side of lathing finished even and fair all as specified and directed.
Material and labour for applying three coats of white washing on walls including preparing new plastered or unplastered surfaces complete all as specified and as directed.(Note:-The unit rate includes for:- (a) Use of all scaffolding, trestles, ladders, cradles, etc.necessary for execution of work and protective measures. (b) Removing of nails, making good holes, cracks, etc. (c) Work in patches, and in narrow widths. bands,cornices, pilasters, etc. and cutting in edges to line,where necessary. (d) Spreading and removing coverings to doors,windows, floors, fittings, etc., to protect them from splashes. (e) Removing and replacing furniture, movable cupboard, chicks, blinds, etc. (f) Washing floors, cleaning glass, joinery, electric fittings, wiring, etc. of drops and splashes and leaving premise, clean and tidy).
Material and labour for applying one coat of white washing on wall including preparing old plastered or unplastered surfaces complete all as specified and as directed.(Note:-Preparation of old surface shall include brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots.The unit rate includes for:- (a) Use of all scaffolding, trestles, ladders, cradles, etc.necessary for execution of work and protective measures. (b) Removing of nails, making good holes, cracks, etc. (c) Work in patches, and in narrow widths. bands,cornices, pilasters, etc. and cutting in edges to line,where necessary. (d) Spreading and removing coverings to doors,windows, floors, fittings, etc., to protect them from splashes. (e) Removing and replacing furniture, movable cupboard, chicks, blinds, etc. (f) Washing floors, cleaning glass, joinery, electric fittings, wiring, etc. of drops and splashes and leaving premise, clean and tidy).
M&L for preparation of new surfaces and appplying two coats of weather coat (Apex) over two primer coats of damp shield to new plastered walls as per manufacturer instruction and applied by approved applicator complete all as specified and directed.
M&L complete removal of existing treatment and appplying two coats of weather coat (Apex) over two primer coats of damp shield to old plastered walls as per manufacturer instruction including properly filling of cracks and applied by approved applicator complete all as specified and directed.
Material and labour for preparation of new surfaces and applying two coats of distemper oil emulsion over a coat of primer and minimum 1mmm layer of wall care putty on wall complete all as specified and directed.
Material and labour for complete removal of existing treatment applying two coats of distemper oil emulsion over one coat of primer and a thin layer of wall care putty, white or tinted on plastered surfaces of wall including preparation of surfaces all as specified and directed.
Material and labour for preparation of new and previously un-treated wood and wood base surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer all as specified and directed.
Material and labour for preparation of new and previously un-treated wood and wood base surfaces of any description, not otherwise described n. exc. 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer all as specified and directed.
Material and labour for preparation of new and previously un-treated steel surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer all as specified and directed.
Material and labour for preparation of old steel surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
Material and labour for preparation of old wooden surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
M & L preparing surfaces of wood and wood based materials,steel and iron work, new or old,of any description and girth,not otherwise described, and treated with tar or coal tar black paint all as specified and directed.
Supply and fix, 3 mm thick figured glass, pin head type and glazing with oil putty in squares n. exc 0.50 sqm in each pane all as specified and directed.
Supply and fix, 4mm thick Sheet glass,ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane all as specified and directed.
Supply, and fix 15 mm bore galvanized iron water tubing medium grade including all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing all as specified and directed.
All as per item No 77 here in before but 20 mm bore.
Supply, hosting and fix, 500 liters rotational moulded polythene water storage water tanks three layer (cylindrical vertical with closed top) hoisted and fixed in position all as described in SSR Part I all as specified and directed.
Supply and fix,as, as in repair, 75 mm dia of outlet PVC(SWR) floor trap, plain with granting including jointing with solvent cement all as specified and directed
Supply only15 mm bore pillar tap, fancy type cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without letter Hot or Cold with long screwed shanuls and fly nuts, screwed for iron pipe or for brass ferrule all as specified and directed.
Supply and fix,as, as in repair Bib taps fancy type 15mm bore dia of pipe , chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified and directed.
S & F PTMT fittings shall be of approved makes for ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed (Minimum weight 2 0 m m - 2 1 0 g m s ) 20mm Bore dia of pipe in mm all as specified and directed.
S & F PTMT fittings shall be of approved makes for Nipple suitable for HDPE water tank.(Minimum weight 20mm- 45gms) 20mm Bore dia of pipe in mm all as specified and directed.
S & F PTMT fittings shall be of approved makes for Stop valve of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-90gms) 15mm bore dia of pipe in mm all as specified and directed.all as specified and directed.
Dismantling Exc 500litre & n exc 1000litre water tanks and removing to store all as specified and directed.
Supply and fix as in repair, stop valve, cast copper alloy, cromium plated, fancy type, screwed down high pressure, with crutch or butterfly handles for 15 mm bore pipe or for unions all as specified and directed.
Supply and fix as in repair, 20mm dia gun metal gate valve conforming to relevant IS with iron wheel head screwed both ends for iron pipe all as specified and directed.
Supply and fix in repair, vitreous china wash basin, white, flat back size 550 x 400 mm, excluding taps, waste chain, plug and porcelain stopper but including brackets, cutting for and pinning in ends of bracket or erecting stand complete all as specified and directed.
Supply and fix in repair, vitreous china squatting pan of Orrisa pattern size 580mm x 440 mm, white, with integral foot rests (excluding flushing cistern and flush pipe) including connection making good to floor all as specified and directed.
Supply and fix , 10 ltrs capacity PVC valve less syphonic action type, low level flushing cistern, white, with inlet, ball valve float and handle including brackets complete all as specified and directed.
Supply and fix in repair, Vitreous China bowl urinal angle back of size 430 x 370 x 340 mm (minimum), with grating and union for discharge pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe all as specified and directed.(Note:- Flushing cistern, trap and waste pipe shall be measured and paid seperately in relevant item of BOQ) .
Supply and fix sinks with drainage board made of stainless steel not less than 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm and bowl size 410mm x 330mm x 160mm complete all as specified and directed.
Supply and fix ,stainless steel kitchen Plate Rack made out of not less than 0.63 mm thick stainless steel sheet and overall size not less than 800mm x 900mm x 250mm complete all as directed.Make:-Suyog/ Prayag or equivalent make as approved by HQ Eastern Command .
Supply and fix, as in repairs, 15 mm dia 450 mm long connection pipe with two PVC PTMT nuts at each ends with rubber washer complete all as specified and directed.
Supply and fix 40mm dia PVC 610mm long waste pipe suitable for sink complete all as specified and directed.
S & F CP 40mm dia waste coupling for stainless steel sink with inlet and outlet screwed for pipe or connections including packing , union and cap etc. complete all as specified and directed.
Supply and fix 110mm bore PVC (SWR)pipe single socketed with rubber ring joints fixed to walls all as specified and directed.
All as per item No 99 here-in-before but 75 mm bore.
Supply and fix PVC (SWR) bends (any radius) for 110 mm bore PVC pipes all as specified and directed.
All as per item No 101 here in before but 75 mm bore.
S & F PVC (SWR) vent cowl 110mm bore complete all as specified and directed.
E/M WORKS:- Taking down carefully copper / alluminium point wiring (Light, fan, socket or power socket) complete including fixtures and fittings such as switches , ceiling reses, pendents, regulators, socket light fitting etc removing materials to store for keeping in safe custody for taking credit (credit for avobe items should be made as per condition seperatly) and making good desturbed surfaces of walls, floor, ceilings etc.
Taking down light fittings any wattage and any type complete all as directed.
Taking down DB/main switch of any size and making good disturbed surface of wall /floor complete all as directed.
Taking down fan, sealing cable end,dismantling blades and removing fan and blades to store complete all as directed.
Material and labour for concealed point wiring for fan / light / exjaust fan/ bell point controlled by one switch with 1.5 sqmm (nominal area) FR PVC insulated stranded copper conductor single core including non metalic PVC conduit medium grade of appropriate size concealed in wall, pressed steel concealed terminal boxes of required size and with top cover 3 mm thick of plastic laminated sheet of reqd colour, painting terminal boxes inside and out side with one coat red oxide primer complete with all accessories and all as specified including 1.5 Sqmm FR PVC insulated unsheathed multistranded copper earth conductor to common earth and connected to earth dolly for fan / light / exjaust fan/ bell point controlled by one switch all as specified and directed. Note:- Material and labourfor cutting chases on walls / ceiling and making good disturbed surfaces including finishing with cement mortar (1:3) etc; are deemed to be included in the quoted rate.
All as per item No 108 here-in-before but wiring with 1.5 sqmm for one 3 pin 5 Amps socket out let on independent board.
All as per item No 108 here-in-before but wiring with 1.5 sqmm for one 3 pin 5 Amps socket out let on sameboard.
All as per item No 108 here-in-before but wiring with 2.5sqmm including 1.5 sqmm PVC insulated, unsheathed multistranded copper conductor cable 1100 volts grade, single core, earth continuity conductor connected to common earth dolly for one15 Amps socket out let on independent board.
Supply and fix, switch piano, flush button, single pole, one way, 5 Amps, complete all as specified.
Supply and fix,Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified.
Supply and fix, switch socket combinatin 2 in 1, 3 pin, 5 Amps flush type all as specified and directed.
Supply and fix, switch socket combinatin 3 pin,16 Amps flush type all as specified and directed.
Supply and fix, socket outlet 2 in 1, 5 pin, 5/6 Amps flush type all as specified and directed.
Supply and fix, switch socket combinatin outlet universal type 5 pin, 5/16 Amps flush type all as specified and directed.
Supply and fix, electronic type ceiling fan regulator, step type,120 W-2 module, suitable for 240 volts AC 100 watt all as specified and directed.
Supply and fix, LED tube light fittings complete suitable for not less than 1 x 20 watts 230 volts 50 Hz wall mounted batten type with intregrated electronic driver complete with all acessories internally pre -wired and including connecting up with copper cable of suitable size and required length completeall as specified and directed.
Supply and fix,not less than 30 W ( 3000 System Lumens ),high efficacy LED street lights Class I,IP66,IK07 with efficacy of greater than 105 lm/W ,wide Voltage Operating Range of 140 V - 270 V,wide temperature operating range of -10 °C to +50 °C,surge Protecion of 4 kV driver builtin surge protections and additional 10 kV surge protecion device complete all as per manufacturer''s instruction.
M & L house service bracket (hook type complete with 3.0m long G.I. pipe 40mm dia Med. grade, two nos900 bends. M.S.hook and stay or guy completeall as specified and directed. (Note:-(a) The unit rates include cutting holes in walls etc. of any description, grouting rag bolts or rag angle iron service bracket, and making good with cement mortar 1:3 including making good finishing to match the existing work and removing rubbish off MOD premises. (b) G.I. pipe house service bracket hook type shall be fabricated with 3.0 m long screwed G.I. pipe of medium quality and will comprise of two No. 90° bends (pipe dia) screwed tight to the top ends of the service vertical limb, the two ends of the service shall be provided with two Nos. of turned spit tight fit, well seasoned teakwood bushings and the bracket shall be fixed plumb vertical against the wall with two Nos.flat iron clamps (fabricated out of 50x6 mm flat iron with 4 No. 16 mm dia ragged bolts of appropriate size with screwed ends, tightened with 16 mm dia nuts with 6 mm thick washer against the clamp tightening collars). The unit rate includes cost of 30 x 5 mm MS flat hook, bolts & nuts & stranded galvanised, wire stay (guy). (c) Angle iron service bracket shall have one end ragged and grouted into the wall and other end drilled with 16mm or 20mm dia hole for fixing service shackle insulator supporting bolt. (d) To take in service shackle fixing height of the service bracket should be such as to have horizontal run of the service from the take off service bracket pole.
Supply,laying,jointing,commissioning and testing underground XLPE insulated armoured (heavy duty) LT electric cable with stranded aluminium conductor suitable for working voltage 1100 V grade 2 core cross sectional area 10Sqmm confirming to IS:7098 PT-I cable laid in trench or passing though pipe or fixed to pole all as specified and directed
Supplying and fixing 1100volts grade heavy duty cable PVC insulated 6sqmm aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular all as specified and directed
Supply and fix, sheet metal enclosure powder coated single phase DB vertical type for fixing of MCBs, DB 8 ways double door with bus bar 200 Amps including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed.
Supply and fix, sheet metal enclosure 4 way SPN DB's IP 30 - IK 08 for MCB, Isolator, RCCB and RCBO as per IEC 61439-3,suitable for flush mounting and surface mounting with 100 A Copper busbar and Neutral bar, Earthbar and Cable ties for Cable management and fully shrouded Neutral bars, prefitted masking sheet,reversible Door for IP 43 & IP 54 DB's complete all as specified and directed.
Supply and fix,MCB C Curve ,Single pole + Neutral 240 V,Nominal Rating 6-32 Amps, 10 kA ISI marked as per IS/IEC 60898-1 2002 Integrated label holder sliding bottom clamp, improved air channels, color coded On/Off indication on dolly, biconnect lower terminals, IP 20 protected terminals, sliding shutters, DC-80 V per pole - 1 kA all as specified and directed.
Supply and fix,MCB C Curve ,Single pole 240/410 V,Nominal Rating 6-32 Amps, 10 kA ISI marked as per IS/IEC 60898-1 2002 Integrated label holder sliding bottom clamp, improved air channels, color coded On/Off indication on dolly, biconnect lower terminals, IP 20 protected terminals, sliding shutters, DC-80 V per pole - 1 kA all as specified and directed.
M & L for rewinding of ceiling fan 1200mm any make and any type of model after taking burnt out old winding wire complete nd cleaning the internal slots of rotor with ring and rewinding the ceiling fan with super enamelled copper winding wire of suitable SWG varnishing baking in oven and reasssembling with new bearings both complete all as specified and directed.
Hanging only ceiling fan (M.D.supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.(Note:-The unit rates includes for clamps, hooks, holdfasts etc. for hanging fans).
Material and labour for earthing complete with galvanized steel plate electrode 60cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level with top edge of earth plate not less than 1.5 mtr deep below normal ground level and connected to galvanized iron or steel earth wire lead 4 mm dia by means of bolts nuts, check nuts and washers protected by galvanized iron pipe 15 mm bore (medium grade) and connected to main switch board or main control board as directed with and including concrete pit in PCC (1:3:6) type CI and pre cast RCC 1:1.5 : 3 type A1, cover slab of size 30 cm cx 30 cm x 5 cm reinforced with 8 mm dia deformed bars both ways @ 10 cm C/C with one lifting handle made out of 8 mm dia MS bar, funnel wiremesh, 20 mm bore GI pipe light grade for watering, charcoal or coke and salt in alternate layers, necessary excavation and earth works in any type of soil complete all as shown on electrical plate No 3 MES schedule part – I and testing on completion all as specified and directed.
Supply & fix water heater (Gyser) storage type, single phase, energy saving 5 star rated 230 volts grade 5 star rated 50Ltrs storage capacity including nut bolts , washers and other site required accessories including taking down old gyser along with accessories complete
Supply & fix water heater (Gyser) storage type, single phase, energy saving 5 star rated 230 volts grade 5 star rated 25Ltrs storage capacity including nut bolts , washers and other site required accessories including taking down old gyser along with accessories complete complete
Materials and labour for sand cushioning with dry course sand to UG cables (8 cm deep before laying of cable and 15cm deep over the cable) in trenches including punning thickness up to 18 cm and consolidation, complete all as directed. (Note :- Punned thickness only will be considered for payment).
Material and labour for for brick protection over cables inside the trench by using common burnt clay building bricks,sub-class"B" designation 75mm,laid dry and flat and widthwise along the axis of the trench complete all as specified and directed.
Chinmay Traders
M/s Borah Enterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .