Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.5 LAccepted-AOC SHOP NO 102 A ONE COMPLEX K V ROAD VILLAGE TOWN JAMNAGAR CITY JAMNAGAR JAMNAGAR GUJARAT 361001 INDIA | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹37.0 L+₹52,933.27 (1.45%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L2 | Rejected-Finance L2 | |
| 3 | L3₹40.0 L+₹3.5 L (9.70%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹41.4 L+₹4.9 L (13.5%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹41.5 L+₹5.0 L (13.6%)Rejected-Finance NO 2 GF AKSHAYRAJ APARTMENT JUBILEE CIRCLE BHUJ 370 001 | BHUJ | KACHCHH | GUJARAT | 370001 | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | EVEREST BUILDERS L1 | DWARKADHISH ENTERPRISE L2 | M/S Rajendra Constructions L6 | suvidhiconstruction L3 | aarti construction L4 | Suraj Builders L7 | M/s. Ambabhai K patel L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth for foundation, etc or for shafts, wells, cesspits, manhole, pier holes, etc and getting out in soft/loose soil complete all as specified as directed by Engineer-in-Charge. | 53.7 | Cubic Metre | 425 ₹22,822.5 | 402 ₹21,587.4 | 450 ₹24,165 | 526 ₹28,246.2 | 500 ₹26,850 | 525 ₹28,192.5 | 400 ₹21,480 Lowest |
| 2.00 | M&L Cement concrete 1:4:8Type D2 (using 40mm graded aggregate) as in foundation, filling and mass concrete complete all as specified as directed by Engineer-in-Charge. | 5.89 | Cubic Metre | 5,400 ₹31,806 | 5,200 ₹30,628 | 8,000 ₹47,120 | 6,000 ₹35,340 | 6,000 ₹35,340 | 6,500 ₹38,285 | 5,000 ₹29,450 Lowest |
| 3.00 | M&L for Reinforced cement concrete (DESIGN MIX M-30, using 20mm graded aggregate) as foundations, including rafts, footings foundation beams, plinth beams, bases for columns, etc basement slabs, under reamed piles and mass concrete complete all as specified as directed by Engineer-in-Charge. | 18.29 | Cubic Metre | 7,000 ₹1,28,030 Lowest | 7,200 ₹1,31,688 | 9,500 ₹1,73,755 | 7,500 ₹1,37,175 | 7,500 ₹1,37,175 | 7,800 ₹1,42,662 | 7,000 ₹1,28,030 Lowest |
| 4.00 | M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits(if any) of foundation and plinth beams, and similar work vertical or to batter, rough finished flat surfaces of concrete complete all as specified as directed by Engineer-in-Charge. | 65.64 | Cubic Metre | 500 ₹32,820 | 522 ₹34,264.08 | 450 ₹29,538 Lowest | 600 ₹39,384 | 600 ₹39,384 | 650 ₹42,666 | 500 ₹32,820 |
| 5.00 | M&L for Reinforced cement concrete (DESIGN MIX M30, using 20mm graded aggregate) as in Beams, cantilivers, bressummers, lintels over 1.5m span complete all as specified as directed by Engineer-in-Charge. | 13.32 | Cubic Metre | 7,600 ₹1,01,232 | 7,200 ₹95,904 Lowest | 9,000 ₹1,19,880 | 8,000 ₹1,06,560 | 7,800 ₹1,03,896 | 8,000 ₹1,06,560 | 7,500 ₹99,900 |
| 6.00 | M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams etc, rough finished surfaces of concrete complete all as specified as directed by Engineer-in-Charge. | 119.63 | Square Metre | 500 ₹59,815 Lowest | 522 ₹62,446.86 | 510 ₹61,011.3 | 600 ₹71,778 | 600 ₹71,778 | 800 ₹95,704 | 500 ₹59,815 Lowest |
| 7.00 | M&L for Reinforced cement concrete (DESIGN MIX M-30, using 20mm graded aggregate) as in Columns, pillars,piers, posts and struts complete all as specified as directed by Engineer-in-Charge. | 4.31 | Cubic Metre | 7,800 ₹33,618 | 7,200 ₹31,032 | 8,000 ₹34,480 | 8,000 ₹34,480 | 7,950 ₹34,264.5 | 8,000 ₹34,480 | 7,000 ₹30,170 Lowest |
| 8.00 | M&L for use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished surfaces of concrete, square, rectangular or polygonal complete all as specified as directed by Engineer-in-Charge. | 49.52 | Square Metre | 500 ₹24,760 Lowest | 502 ₹24,859.04 | 500 ₹24,760 Lowest | 600 ₹29,712 | 580 ₹28,721.6 | 520 ₹25,750.4 | 500 ₹24,760 Lowest |
| 9.00 | M&L for Reinforced cement concrete (DESIGN MIX M-30, using 20mm graded aggregate) as Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified as directed by Engineer-in-Charge. | 11.89 | Cubic Metre | 7,800 ₹92,742 | 7,200 ₹85,608 Lowest | 8,000 ₹95,120 | 8,000 ₹95,120 | 7,900 ₹93,931 | 8,000 ₹95,120 | 7,500 ₹89,175 |
| 10.00 | M&L for use and waste formwork to soffits of suspended slabs, such as roof slabs, floor slabs, landing and similar work not exc exceeding 200mm thick(Horizontal or sloping), rough finished surfaces of concrete complete all as specified as directed by Engineer-in-Charge. | 79.28 | Square Metre | 520 ₹41,225.6 | 542 ₹42,969.76 | 550 ₹43,604 | 600 ₹47,568 | 550 ₹43,604 | 590 ₹46,775.2 | 500 ₹39,640 Lowest |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
22 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Sumukh Swaroop
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No 1 Jamnagar 361003
CERTAIN WORKS TO IMPROVE STORAGE FACILITY AT WSA AND MISC MINOR WORKS AT AF STN JAMNAGAR UNDER GE (AF) JAMNAGAR NO 1
2025_MES_733523_1
8363/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
JAMNAGAR
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No 1
₹72,000
Yes
12 Dec 2025
1 Oct 2025
23 Oct 2025
1 Oct 2025
22 Oct 2025
15 Oct 2025
Amount
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth for foundation, etc or for shafts, wells, cesspits, manhole, pier holes, etc and getting out in soft/loose soil complete all as specified as directed by Engineer-in-Charge.
M&L Cement concrete 1:4:8Type D2 (using 40mm graded aggregate) as in foundation, filling and mass concrete complete all as specified as directed by Engineer-in-Charge.
M&L for Reinforced cement concrete (DESIGN MIX M-30, using 20mm graded aggregate) as foundations, including rafts, footings foundation beams, plinth beams, bases for columns, etc basement slabs, under reamed piles and mass concrete complete all as specified as directed by Engineer-in-Charge.
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits(if any) of foundation and plinth beams, and similar work vertical or to batter, rough finished flat surfaces of concrete complete all as specified as directed by Engineer-in-Charge.
M&L for Reinforced cement concrete (DESIGN MIX M30, using 20mm graded aggregate) as in Beams, cantilivers, bressummers, lintels over 1.5m span complete all as specified as directed by Engineer-in-Charge.
M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams etc, rough finished surfaces of concrete complete all as specified as directed by Engineer-in-Charge.
M&L for Reinforced cement concrete (DESIGN MIX M-30, using 20mm graded aggregate) as in Columns, pillars,piers, posts and struts complete all as specified as directed by Engineer-in-Charge.
M&L for use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished surfaces of concrete, square, rectangular or polygonal complete all as specified as directed by Engineer-in-Charge.
M&L for Reinforced cement concrete (DESIGN MIX M-30, using 20mm graded aggregate) as Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified as directed by Engineer-in-Charge.
M&L for use and waste formwork to soffits of suspended slabs, such as roof slabs, floor slabs, landing and similar work not exc exceeding 200mm thick(Horizontal or sloping), rough finished surfaces of concrete complete all as specified as directed by Engineer-in-Charge.
M&L for Use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm widefair finished surfaces of concrete complete all as specified as directed by Engineer-in-Charge.
M & L for Pre-cast cement concrete block masonry with solid blocks Type C-1, 1:5:8 using 20mm graded aggregate , exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified as directed by Engineer-in-Charge.
M&L for mild steel CRS TMT bars 10mm dia and over, cut to length, bent to shape required, includiing cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips complete all as specified as directed by Engineer-in-Charge.
M&L for mild steel CRS TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, includiing cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips complete all as specified as directed by Engineer-in-Charge.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc 15cm thick, spread, levelled and rammed including watering complete all as specified as directed by Engineer-in-Charge.
M&L for Hardcore(broken stone of boulder)of guage n exc 63mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified as directed by Engineer-in-Charge.
M&L for 100mm thick Cement concrete type B-2, 1:4:8 (using 40mm graded aggregate) as in sub base complete all as specified as directed by Engineer-in-Charge.
M&L for 25mm thick Cement concrete 1:2:4 type B-0 (using 12.5mm graded aggregate) as in flooring, finished surfaces even and smooth with using extra cement complete all as specified as directed by Engineer-in-Charge.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match shade of the slab including rubbing and polishing over 20mm thick screed bed in Cement Mortar 1:6 complete all as specified as directed by Engineer-in-Charge.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10 mm cement screed in Cement Mortar 1:6 and jointed including rubbing and polishing complete all as specified as directed by Engineer-in-Charge.
M&L for 50 mm thick Cement concrete type C-2 , 1:3:6 (using 20mm graded aggregate) as in plinth protection /flooring finished surface even and smooth without using extra cement complete all as specified as directed by Engineer-in-Charge.
M & L for screed bed or bedding layer of mortar 10 mm thick in cement mortar 1:4 including mixing only liquid water proofing compound as per manufactures instruction and finishing the surface fair and even complete all as specified as directed by Engineer-in-Charge.
Supply only liquid water proofing compound complete all as specified as directed by Engineer-in-Charge.
M & L for APP based polymer membrane minim weighing 3 kg/sqm and minimum 3 mm thick reinforced with polyster non fabric ( wt not lass than 150 grm/sqm) land complete and including a coat of approved cold applied bituminous oil based primer at the rate of 250 gms per sqm shall be laid by torch application method complete all as specified as directed by Engineer-in-Charge.
M & L for Steel rolling shutters, 1.00 mm thickness of laths without ball bearing, as specified including top cover, enchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: but gear operated type with bevel gear box and crank handle complete all as specified as directed by Engineer-in-Charge.
S & F for position anodised aluminium power coated (minimium thickness of power coating 50 mircon) threetrack window (two shutter glazed and one shutter gauge) with frame, glazed with 4 mm thick tinted glass, and wire gauge with stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm including rubber bead joining cleat for fixing in position concealed type lock for all two shutter PVC roller etc all as specified below, and as directed by Engineer-in-Charge including taking dwon old window. (a) Frame (top & side section shall of size 92.00x31.75x1.50mm (section No 20831) (b) Frame (bottom) section shall of size 92.00x31.75x1.50mm (section No 20832) (c) Top & side member of shutter section shell be of size 18.00x40.00x1.55mm (section No 20738) (d) Shutter intercock section shall be size 18.00x40.00x1.45 mm (section No 20737) (e) Bottom member of shutter section shell be size 18x40x1.55mm (Section No 20736) Note :- Section nos given above are of make jindel, contactor may be use similar section of other make mentioned in PS Ser No 21
M&L for 10 mm thick rendering on fair faces of brick work or concrete sureces in Cement Morata 1:4 finished surface even and smooth without using extra cement complete all as specified as directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces of wall incl pilasters / cornices etc and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS-15489 : 2004 : Alkali & fungal resistant, dirt resistant, exterior paint of required shade (company Depot Tinted) with silicon additives @1.43 Liters/10 Sqm over and including priming coat of exterior primer applied @ 0.90 Litre / 10 Sqm complete all as specified as directed by Engineer-in-Charge.
M&L for 10mm thick rendering on fair faces of brick work or concrete sureces in Cement Mortar 1:6 finished surface even and smooth without using extra cement complete all as specified as directed by Engineer-in-Charge.
M&L Preparing newly plastered surfaces of walls and applying two coats of oil bound distemper over one coat of Chalk whiting, on plastered surfaces, preparatory to distempering complete all as specified as directed by Engineer-in-Charge.
M&L for 5mm thick rendering on fair faces of brick work or concrete surfaces in Cement Mortar 1:3 finished surface even and smooth without using extra cement as in ceiling complete all as specified as directed by Engineer-in-Charge.
M&L Preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well remming in layets not exc 25cm in soft/loose soil complete all as specified as directed by Engineer-in-Charge.
Removing (soil) excavated materials exc 1.5 km and depositing where directed at a level n exc 5km and depositing where directed complete all as specified as directed by Engineer-in-Charge.
Excavating over areas, n. exc 1.5 m deep and getting out in soft / loose soil complete all as specified as directed by Engineer-in-Charge.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified as directed by Engineer-in-Charge.
Material & Labour for pressed precast concrete interlocking power block any shape and size confirming to IS-15658-2006 of 60 mm thickness M-35 grade with Grey cement and pigment complete all as specified as directed by Engineer-in-Charge.
M&L for Reinforced cement concrete (DESIGN MIX M-30, using 20mm graded aggregate) as Chajjas complete all as in specified as directed by Engineer-in-Charge.
M&L 18-20mm thick Granite(of any type) work(table rubbled and polished) in steps, jambs, pillar, windowcills, cooking platforms and like in cement mortar(1:4) including pointing in white cement(1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified as directed by Engineer-in-Charge.
M&L Non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in Cement Mortar 1:4 complete all as specified as directed by Engineer-in-Charge.
Use and waste formwork to chullah hoods, chajjas, troughs and similar items including edges rough finished surfaces of concrete complete all as specified as directed by Engineer-in-Charge.
S&F Framed work such as grills, gratings etc, with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders framed balusters, walk ways, railing, framework of water tanks and similar work conforming to Fe410-O or Fe 310-O complete all as specified as directed by Engineer-in-Charge.
M & L for rendering 10 mm thick in CM 1:4 over and including 25mm thick cement concrete Type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in padding on roof slab even and smooth finishing without using extra cement including mixing only liquid water proofing compound as per manufactures instruction and finishing the surface fair and even complete all as specified as directed by Engineer-in-Charge.
S & F in position anodised aluminium power coated (minimum thickness of power coating 50 mircon) door shutter with frame, partly glazed with 5 mm thick tinted glass and partly panelled with 9mm thick prelaminated partical board with both side decorative laminnated including rubber bead, jointing cleat for fixing in position, aluminim door handle 150 mm size, aluminium barrel tower bolt 200mm size etc including taking down of old frame with shutter of any size complete all as specified as directed by Engineer-in-Charge. (a) Frame (top & side) section shall of size 101.60x44.75x2.4mm (section No 14021) (b) Vertical members of shutter section shall be of size 85.00x44.45x2.00mm (section No 19560) (c) Top member of shutter section shall be of size 83.50x44.45x2.00mm ( Section No 19596) (d) Lock rail (middle member) of shutter section shall be of size 150.00x44.45x3.00mm (Section No 19596 (e) Bottom member of shutter section shall be of size 150.00x44.45x3.10mm (section No 19584) (f) Glazing clip for securing glass of shutter shall be of 0.80mm thick (Section No 19370) Note :- Section nos given above are of make jindal, contactor may be use similar section of other make mentioned in PS Ser No 21.
S & F for false ceiling of Non asbestos fiber cement building boards, manufactured from homogeneous mixture of cement , quartz and celluose and cured with high pressure steam using auto clacving process confriming to IS 14862, of size 600mmx600mmx 4mm thick fixed over and including anodised aluminiuum power coated (minimum tickness of power coating 50 micron) snap grid frame work of T section (main & cross member) of size 25mmx25mmx1.5 mm thick in square pattern of grid size 600mmx600mm (i) The aluminium frame work willl supported on side wall with used of aluminium L section of size 25 mmx25mmx1.5mm angle etc. Snap grid shall be supported with hanger of 4mm dia, galvanised iron wire adjusting level fixed to roof slab/ truss etc by means of ceiling cleats made out of galvanised iron flat o size 40x3 mm size 60mm long and expansion hold fastenets 12.5 mm dia 40 mm long complete all as specified and as directed by Engineer-in-Charge.
S & F for Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame specified and as directed by Engineer-in-Charge.
S & F for 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC Frame as specified and as directed by Engineer-in-Charge.
M&L for complete removal of existing treatment of surfaces of walls and applying two coats of oil bound distemper over one coat of Chalk whitining, on plastered surfaces, preparatory to distempering complete all as specified as directed by Engineer-in-Charge.
M&L for preparing new or previously untreated steel and iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over red oxide primer complete all as specified as directed by Engineer-in-Charge.
S & F of 18 mm thick Rajshri WPC sheet of one side Prelam/ Rigidlam and other side balancing laminate colour of Density 650 kg/cbm to make kitchen cabinet shutter/ drawers/ Front shutters complete as specified as directed by Engr-in-Charge. Make :- (Rajshri Plastiwood or equivalent as approved by GE)
S & F of 12 mm thick Rajshri WPC sheet of Plain colour of Density 650 kg/cbm fixed with screws, solvent cement/ adhesive to make wall mount kitchen cabinate back and pull out drawer sides complete all as specified as directed by Engineer-in-Charge.. Make :- (Rajshri Plastiwood or equivalent equivalent as approved by GE)
S & F for 20mm wide and 1 mm thick PVC EDGE bidding pasted of edge with suitable adhesive complete all as specified as directed by Engineer-in-Charge.
S & F of auto closing hinge openable at 0 degree for kitchen cabinet shutter complete all as specified as directed by Engineer-in-Charge.Make :- (Hettich, Ebco, Prime)
S & F of stainless steel handles 200 mm size for kitchen cabinet shutter complete all as specified and as directed by Engineer-in-Charge. Make :- (Hettich, Ebco, Prime)
Excavating in soft/ loose soil for post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n.exc 50m and making good surface complete all as specified as directed by Engineer-in-Charge.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified as directed by Engineer-in-Charge.
M & L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410-W (Gde-E-250) quality A complete all as specified as directed by Engineer-in-Charge.
S & F for 6 mm thick multiwall polycarbonate sheeting on roofing including aluminium fillets at joint and aluminium angle (size 40x40x1.5 mm) at end, fixed with screw and all fitting and fixrure complete all as specified and as directed by Engineer-in-Charge.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified as directed by Engineer-in-Charge.
M & L for Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified as directed by Engineer-in-Charge.
S& F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.complete all as specified as directed by Engineer-in-Charge.
M & L for 100 mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate) complete all as specified as directed by Engineer-in-Charge.
M & L for cement concrete type B-1,1:2:4 (20mm graded aggregate) as in roads/ hardstanding of thickness 150mm including steel form work and finishing the surface using floater etc all as specified as directed by Engineer-in-Charge.
S & F for aluminium partition wall of section as in frame/ single double grove of section 65.5x38.10x2.00mm thick including 5 mm thick tinted glass , 20 mm thick pre laminated partical board with all neccessary fitting. Vertical section has to be supported with angle of size 65x65x6mm thick including making good to existing surface, complete all as specified as directed by Engineer-in-Charge.
S & F Aluminium Wardrobe hooks (single) 50mm to 60mm complete all as specified as directed by Engineer-in-Charge.
Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. including making good the disturbed surfaces complete all as specified and as directed by Engineer in Charge.
Material & Labour for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn and including PVC conduit of suitable size , including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc including PVC terminal box of suitable size complete all as specified as directed by Engineer in Charge.
All as per item ser No 72 here-in-above but for one 3 pin socket outlet, 5 Amps, independent board , with cables (Wiring with Copper conductor PVC sheathed FRLS cables) 1.5 sq. mm size in and including PVC conduit of suitable complete all as specified as directed by Engineer in Charge.
All as per item ser No 72 here-in-above but for one 3 pin socket outlet, 5 Amps on the same board with other switches, with cables (Wiring with Copper conductor PVC sheathed FRLS cables) 1.5 sq. mm size in and including PVC conduit complete all as specified as directed by Engineer in Charge.
All as per item ser No 72 here-in-above but for one 3 pin socket outlet, 15 Amps, independent board , with cables (Wiring with Copper conductor PVC sheathed FRLS cables) 2.5 sq. mm size in and including PVC conduit complete all as specified as directed by Engineer in Charge.
Material & Labour for concealed point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn and including PVC concealed Conduit not less than 20 mm dia , including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc including pressed steel terminal box of suitable size for switch complete all as specified as directed by Engr-in-charge. Note:- ( Note - Cost for Cutting chases and making good to facings where required and pointing in cement mortar 1:3 is deemed to be included in quoted rates).
All as per item ser No 76 here-in-above but for one 3 pin socket outlet, 5 Amps, independent, with cables (Wiring with Copper conductor PVC sheathed FRLS cables) 1.5 sq. mm size in and including PVC conduit complete all as specified as directed by Engineer in Charge.
All as per item ser No 76 here-in-above but for one 3 pin socket outlet, 5 Amps on the same board with other switches, with cables (Wiring with Copper conductor PVC sheathed FRLS cables) 1.5 sq. mm size in and including PVC conduit complete all as specified as directed by Engineer in Charge.
All as per item ser No 76 here-in-above but for one 3 pin socket outlet, 15 Amps, independent, with cables (Wiring with Copper conductor PVC sheathed FRLS cables) 2.5 sq. mm size in and including PVC conduit complete all as specified as directed by Engineer in Charge.
S&F Switch piano, flush type single pole, one way 5 Amp including connection complete all as specified as directed by Engineer in Charge.
Supply & Fixing Socket outlet 3 pin, 6A, flush type complete all as specified as directed by Engineer in Charge.
S&F in repair switch socket combination flush type 6/16 Amps, 5 in 1 multipurpose including connection complete all as specified as directed by Engineer in Charge.
Supply & Fixing in Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body complete all as specified as directed by Engineer in Charge.
Supply & fixing of sheet metal enclosures for fixing MCBs Single pole and neutral 8 way, 240 volts with 200 Amps rated bus bar withe double door fixed on flush to the wall including making the hole in the wall and fixing the DB including cement work and plastering complete all as specified as directed by Engineer in Charge.
Supply & fixing of Sheet metal enclosures for fixing MCBs Single pole and neutral 4 wayTPN , 240 volts with 200 Amps rated bus bar with double door fixed on flush to the wall including making the hole in the wall and fixing the DB including cement work and plastering complete all as specified as directed by Engineer in Charge.
Supply and fix MCB’s triple pole & neutral, 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting complete all as specified as directed by Engineer in Charge.
Supply and fixing of MCBs single pole and neutral, 'C' Curve type capacity 32 Amps ,10KA & 240 Volts complete all as specified as directed by Engineer in Charge.
Supply and Fixing of MCB single pole, 'C' curve type capacity 6 to 32 Amps capacity complete all as specified as directed by Engineer in Charge.
Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to GI wire 4mm dia by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore galvanised iron medium grade and 40 mm bore galvanised iron light grade for earth strip protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion. Note:-Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length (ii) Earthing considered for New room and New shed
S&F in repairs energy efficient decorative ultra slim LED tube light fitting with built in LED & integral LED driver 22 watt, aluminium extruded channel (approximate length 1200 mm) housing & diffuser with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed by Engr –in-charge.
Supply and fixing LED Building security light fitting 36 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified as directed by Engineer in Charge.
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including heavy duty PVC rigid conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified as directed by Engineer in Charge. Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one RM for payment.
Taking down / Dismantling carefully the indoor and outdoor unit of Split AC of capacity 1.5 TR / 2.0 TR with outdoor stand, plate for indoor unit and connected wiring, Transportation of complete & 2 set from old location to new location (with AF station Jamnagar), refixing of same AC at new location complete all as specified as directed by Engr-in-Charge & detail as under:- (a) Fixing of indoor unit wall mounting type (to be installed inside the room) complete with, draining out arrangement for condensed water, fixing of inter connection pipe, all as directed. Fixing of cooling unit on wall shall be as per standard recommendation practice of manufacturers. (b) Erection of condenser, compressor unit on outside of the building, fixed over old clamp / bracket, all as per standard practice of manufacturer. (c) All civil work such as making hole in the wall for passing of pipe etc, to be done, as directed by Engr-in-Charge including making good disturbed surface. (d) concealing of refrigerant pipe with PVC flexible pipe. (e) Cost of extention of pipe due to site condition if required are deemed to be included in the quoted rate
Supply and fix BLDC ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor complete all as specified as directed by Engineer in Charge.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade, of size 4 core 16 sq mm (from exisiting Main VTPN to TPN DB) complete all as specified as directed by Engineer in Charge. Note : Cable to be run on roof/wall
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade, of size 4 core 10 sq mm (From LT Panel to Main DB) complete all as specified as directed by Engineer in Charge.
Excavation in trenches n exc 1.5m wide and n.exc 1.5 m in depth for laying of cable,pole foundation .etc no exc 10 sqmon plan and nexc 1.5 m in depth and getting out.in soft/loose soil complete all as specified as directed by Engineer in Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified as directed by Engineer in Charge.
Removing excavated material n exc 50m and depositing where directed at a level n.exec 1.5m above starting point complete all as specified as directed by Engineer in Charge.
Supply and filling fine sand to the full width of trenches for protection of cables including spreading and punning down including watering consolidation complete all as specified and as directed by Engineer in Charge. Note : Thickness of stone dust will be paid after cushioning after punning.
M&L for brick, subclass 'B' well burnt, laid dry flat in trenches for protection of cable over LT cable, complete all as specified and as directed by the Engineer-In-Charge
Supply, installation and testing Flame proof Air cooled Split type AC unit with cooling functions and suitable to operate at ambient conditions of (22 Deg C +,- 3 in cooling mode) Air conditoner will have following conditons :- (a) Refrigerant - R-410 a/R-32/R-407 (b) EER- 5 Star Rating (c) Tonnage - 1.5 TR (d) Indoor Noise level - Not more than 40 Db (e) Filter - As recommended by OEM (f) Remote - As recommended by OEM including 02 Nos remote bty (g) Temp display, turbo mode and auto swing facility. All specification will be as per IS-1391 (Part 2) and latest amendments
Note for item No 102 :- The cost of following items deemded to be included in quoted rate. (a) Copper pipe duly insulated between indoor/outdoor unit upto lenght 10mtr for each unit (b) MS Bracket for outdoor unit duly power coated with fixing arrangement. (c) Making of hole in walls including civil work , sleeves and making good to the disturbed surface/wall. (d) Testing and commissioning of the Air conditioner to the entire satisfaction of Engineer in Charge (e) PVC round sheathed copper cable of suitable size for connecting indoor and outdoor unit upto supply point as per site requirement
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA should be enclosed in steel box complete all as specified as directed by Engineer in Charge.
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4 Sqmm each, PVC insulated, unsheathed, fire retardant, low smoke Halogen (FRLS-H) drawn through and including Rigid steel conduit with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified as directed by Engineer in Charge. Note: 2 Runs of main cable, one run earth wire and Steel conduit will be measured as one running meter for payment
Supply and fixing Flame proof switch socket & plug combined in LM6 cable termination box, in LM6, , 32A, 4P+earth complete all as specified as directed by Engineer in Charge.
Supply and fixing of switch flame proof rotary type with termination box in LM6, 16A, single pole 250V all as specified and directed
Supply and fixing LED light fitting 1x18/20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified as directed by Engineer in Charge.
Supply and fixing flame proof exhaust fan of size 305 mm (12'') sweep 240 V 50 Hz , 1440 RPM single phase heavy duty complete with louver shutter and flame proof wire from ceiling rose to exhaust fan, complete all as specified as directed by Engineer in Charge.
Supply and fix Flame proof air circulator 450 mm in aluminum alloy LM 6 Construction , certified by CMRS , Dhanbad for Group I, IIA, IIB, complete all as specified as directed by Engineer in Charge. .
S & F sheet metal enclosure MCB DB SPN 4 way with 200 amps rated bus bar 240 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 having door earthing complete all as specified as directed by Engineer in Charge.
S&F LED type building security light of capacity 35/36 watt white light with driver, having luminaries Efficiency not less than 100 lm / Watt, fixed in Pressure Die Cast Aluminum housing, & glass cover, Ingress protection of IP 66, including all necessary fitting & fixture,& connecting complete all as specified as directed by Engineer in Charge.
M&L for point wiring for one light/fan point controlled by one flame proof switch, complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LS (Flame Retardant Low Smoke) cable 1100 volts grade, drawn through and including mild steel ERW conduit not less than 20mm dia, including all accessories like bend, tees, junction boxed etc. with 1.5 Sqmm multi stranded copper conductor PVC insulated, unsheathed, FR-LS cable as a earth wire connected to common earth dolly etc complete. Note : Cost of chase cutting and making good surface area are deemed to be included in the quoted rate.
DWARKADHISH ENTERPRISE (BID ID -3454000)
suvidhiconstruction (BID ID -3455448)
aarti construction (BID ID -3456548)
M/s. Ambabhai K patel (BID ID -3457010)
M/S Rajendra Constructions (BID ID -3454871)
Suraj Builders (BID ID -3456593)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
PS.pdf
Tender Documents • 0.97 MB
BOQ_821318.xls
BOQ • 1.90 MB
CORRIGENDUM.pdf
PDF • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .