Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC 272 VIKAS KUNJ VIKAS PURI NEW DELHI 110018 | WEST | DELHI | 110018 | L1 | Accepted-AOC Selected | |
| 2 | L2₹22.0 L+₹4.1 L (23.0%)Rejected-AOC | L2 | Rejected-AOC Selected |
Tender Value
₹20.0 L
EMD Value
₹39,929
Closing Date
20 Oct 2018, 3:00 pmClosed
Executive Engineer (E)
EEE PWD DHC and ND/Central G.F. MSO Bldg. ND
Routine maintenance , operation of Electrical Installation and allied services etc
2018_PWD_160066_1
154 /EE (E)/PWD DHC and ND/Central /2018-19
Open Tender
Electrical Works
Works
365 days
Delhi
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹39,929
21 Oct 2020
9 Oct 2018
20 Oct 2018
9 Oct 2018
20 Oct 2018
9 Oct 2018
Amount
Supplying and fixing of following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. (a) 3 Module
(b) 6 Module
(c) 8 Module
Supplying and fixing of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (a) 15/16 ampers switch
(b) 6 pin 15/16 ampers multi socket outlet
Supplying and drawing of following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit etc as required. a) 3 x 1.5 sq. mm
b) 3 x 4 sq. mm
Supplying and drawing of 3 core 2.5 sq. mm size PVC insulated PVC sheathed copper conductor flexible multicore cable in the existing pipe/surface connections etc as required.
Supplying and drawing of following pairs 0.5 mm diameter FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/PVC conduit etc as required. a) 2 Pairs
b) 4 Pairs
Supplying, installation, testing & commissioning of following sizes heavy duty Exhaust fans complete with all accessories including connection with 1.5 sq mm FRLS PVC insulated copper conductor single core cable & earthing complete etc as required. (a) 300 mm sweep size, 900 rpm
(b) 450 mm sweep size, 900 rpm
Supplying & Fixing of 400mm sweep size oscillating type wall fan with the help of dash fastners including connections etc as required.
Providing & Fixing of 10 Liters Capacity energy efficient geyser on the surface of wall with the help of dash fastners including connections etc. as required.
Supplying, installation, testing & commissioning of 20W to 22W, 6000K (1200 mm) energy efficient LED wall mounted light luminaries, extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver, suitable to work on 230 volts, AC supply complete with connection etc. with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required at site.
Supplying & fixing of surface type energy efficient 15 to 18 watts LED full window glare free opal diffuser luminaries of size 300 x 300 mm including connection with 3x1.5 Sq mm FRLS PVC insulated copper conductor single core cable and testing etc. as required. The Total minimum system efficacy of luminaries should be minimum 100 lumen /watt colour temperature 5500K to 6500K, power factor>0.95, CRI (Ra)>75, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram.
Supplying, installation, testing & commissioning of energy efficient recessed mounted type 34W to 38W full window glare free opal diffuser LED panel luminaries of size 595mm x 595mm (nominal size) suitable for both Armstrong/POP/Geypsum Board or grid false ceiling fabricated with MS powder coated white CRCA housing including mounting with the help of chain/other suitable method, hanging from the ceiling including connections with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. The Total system Lumen of 34W to 38W LED should be 3600 with minimum system efficacy of 100 lumen /watt colour temperature 5500K to 6500K, power factor>0.95, CRI (Ra)>75, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram.
Supplying & fixing of energy efficient 15 watts LED down lighter luminaries in the surface/existing false ceiling including connection, testing etc. as required. The Total minimum system efficacy of luminaries should be minimum 80 lumen /watt colour temperature 5500K to 6500K, power factor>0.95, CRI (Ra)>75, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram.
Day to day Routine maintenance of the wall clocks (approximately 300 nos) installed at various locations of Delhi High Court, New Delhi by deploying qualified staff (i.e. technician )from 8:30 AM to 4:30 PM on all working days of the month excluding Sundays & Holidays and replacement of required material such as pencil cells, mechanical movement and front glass etc. issued by the department to the contractor without any extra cost etc as required.
Providing and fixing of new wall clocks at various location, as and when desired by the Delhi High Court authority etc as required
Providing services for day to day maintenance, operation & servicing/overhauling of 80/60 inbuilt R.O. water cooler (approximately 31 nos.) UV water cooler (approximately 16 nos.) and AG-200 system (approximately 3 nos.) water cooler installed at various locations in Delhi High Court by deploying 1 No technician/operator with 1 No. Khallasi from 9:00 AM to 5:00 PM of all working days of the month excluding Sundays & Holidays etc as rquired.
Supplying and replacement of following items for above installation as mentioned in item No.15 for the existing R.O. & water cooler of aquagaurd (Eureka Forbes Make Model No. 80/60 inbuilt UV water cooler AG-200 system) including less credit for dismantled material under buy back arrangement etc as required a) Particulate filter 10”
b) Sediment filter 10”
c) Pre carbon filter 10”
d) Post carbon filter 10”
e) TFC membranes
f) 2x10” sediment filter
g) 20” Post carbon filter
h) TFC membrane 75 GDP
i) 20” pre filter spun 5 micron
j) S.S. Tap for water cooler
k) 45 mfd Running Capacitor
l) Pumps
m) Compressor water cooler (60/80 R.O.)
Supplying and charging of R-22 refrigerant gas in the water coolers with inbuilt water purifier after pressure testing and leakage detection and rectification of the breakage (if any) testing and commissioning complete etc. as required.
A G ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .