GE South Tezpur
GE South Tezpur, Mission Charlia
CERTAIN MISC MAINT E/M WORK AT AGE MISA CAMP UNDER GE (SOUTH) TEZPUR
2023_MES_610770_1
8766
Open Tender
Civil Works
Item Rate
210 days
GE South Tezpur
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE South Tezpur
₹46,000
Yes
11 Oct 2023
26 Jul 2023
7 Sept 2023
26 Jul 2023
4 Sept 2023
10 Aug 2023
27 Jul 2023 - 9 Aug 2023
Amount
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and exc. 1.5m depth not exc 3.0m depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil complete all as specified and as directed.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying and punning to 18 cm complete all as specified and as directed. (Note : Punned thickness shall be measured).
M&L Bricks common burnt clay building bricks, sub-class ‘B’ designation 75 laid dry width wise across the line of cable in trenches for protection of UG cable complete.
M&L 100 mm bore steel for tubing light grade ISI marked for protection of cable including necessary joint including taking down old u/s one complete all as specified and as directed. (Make TATA/JINDAL/BANSAL).
Supply and fix in repair's 50mm bore GI Tubing medium grade in Trenches/ Floor/Pillar and connection in old or news position including fitting like socket /Union/Tee/Reducer Nipple etc, complete all as specified and as directed by Engineer-in-Charge.
M&L 40 mm bore steel for tubing light grade ISI marked for protection of cable including necessary joint including taking down old u/s one complete all as specified and as directed. (Make TATA/JINDAL/BANSAL).
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32 mm x 6mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting (Inside cavity to be made in Pit for placing cover slab) made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR part 1 including testing on completion all as specified and directed incl demolition to existing.
M & L Two coat of Aluminium paint after preparation of old surface of Steel/Iron electric poles exc 10cm in width or girth including pole fittings with two coat of Aluminium paint such as cross arms of any description anti climbing devices nut bolts etc and cement based paint of PCC coping and painting 05 Nos of strips of each 30cm height of Fluorescene Yellow & Black synthetic enamel paint alternatively above coping including numbering with Black colour paint on poles in two segments on Yellow colour circular/rectangular block on Aluminium paint all as specified and as directed by Engr-in-Charge.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade cross sectional area 300 sq. mm 3½ Core including Brass Glands including dismantling old u/s cable complete all as directed by Engr-in-Charge.
All as per Item No 12 but 120 Sqmm 3½ Core
All as per Item No 12 but 95 Sqmm 3½ Core
All as per Item No 12 but 50 Sqmm 3½ Core
All as per Item No 12 but 25 Sqmm 4 Core
All as per Item No 12 but 16 Sqmm 4 Core
All as per Item No 12 but 16 Sqmm 2 Core
All as per Item No 12 but 10 Sqmm 2 Core
M & L for heat shrink type straight through jointing kit for 1.1 KV XLPE/PVC cables of size 6 to 16 Sqmm 4 core including testing after jointing.Complete all as specified & directed Make : -3M/Denson/Raychem.
All as per Item No 20 but 25 to 50 Sqmm 4 Core
All as per Item No 20 but 70 to 120 Sqmm 4 Core
All as per Item No 20 but 150 to 185 Sqmm 4 Core
Painting of outdoor/indoor Feeder Pillar Boxes of MS Sheet with spray gun after scrapping old surfaces any size complete all as specified and directed
Isolate, disconnect, dismantle the burnt out lugs from main switches/MCCB/ACB/Breakers and Supply and fix new lugs of 06 sqmm to 16 sqmm size of cables with crimping tool as per existing one including fixing, insulatio, termination to main switches/MCCB/ACB/Breakers complete al as directed by Engr-in-Charge.
All as per Item No 25 but 25 sqmm to 50 sqmm
All as per Item No 25 but 70 sqmm to 95 sqmm
All as per Item No 25 but 120 sqmm to 240 sqmm
All as per Item No 25 but 300 sqmm to 400 sqmm
M&L for drilling hole horizontally road under ( min 1 mtr) pavement hardstanding by treanchless technology using ultra sound technique and necessary machine suitable and including 150 mm dia HDPE pipe.Complete all as specified & directed
Dismantling existing steel or cement poles/ struts, any size carefully for reuse including necessary excavation demolition of concrete transportation cost etc. and removing the old unserviceable rubbish etc.Complete all as specified & directed
M & L for Steel tubular swaged poles complete with cast iron/MS base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-22 , 8.5 meter long including making hole of 2 inch dia at 2.5 meter from bottom and 1 inch at 8 meter from bottom complete all as specified & directed. Note: PCC anti climbing device, cross arms insulator, ACSR conductor and earth work measure and paid separately)
M&L PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for stay set /Pole/ Panels etc including fair finish even and fir to exposed surfaces without using extra cement complete all as specified and as directed.
M & L PCC (1:2:4) type B-1 (with using 20 mm graded stone aggregate) as coping of pole/panel including necessary form work as required complete as directed
M & L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface.Complete all as specified & directed
S & F in repair MCCB 4 pole , 415 V Fixed type 100 Amp, with breaking capacity 16 KA including spreader link and seperator and any modification required for fixing of MCCB.Complete all as specified & directed
S & F in repair MCCB 4 pole , 415 V Fixed type 63 Amp, with breaking capacity 16 KA including spreader link and seperator and any modification required for fixing of MCCB.Complete all as specified & directed
Supply and fix in replacement of MCCB 250 Amps, 4pole, 415volt, 25 KA breaking capacity with all the necessary electrical connections, all as specified and directed.
Supply and fix in replacement of MCCB 200 Amps, 4pole, 415volt, 25 KA breaking capacity with all the necessary electrical connections, all as specified and directed.
Supply and fix in replacement of MCCB 160 Amps, 4pole, 415volt, 30 KA breaking capacity with all the necessary electrical connections, all as specified and directed.
S & F in replacement of MCB TPN 415 Volts, 63 Amps, 50 Hz, breaking capacity 10KA, C series all as specified and directed
S & F in replacement of MCB SP 6-32 Amps, 240 V, 50 HZ breaking capacity 10KA, C series all as specified and directed.
Material and labour for filtration of transformer oil of Transformer of capacity upto 500 KVA with ultra high vacuum filteration machine and checking dielectric strength (BDV), dielectric dissipation factor, neutralizing value (total activity), upto 60 KV with 2.5 mm Gap sludge content, flush point of transformer oil from Standard Testing Laboratory all as specified. Refilling the transformer oil in the shell of transformer after carrying out filteration and heating up oil to achive required dielectric strength and submitting the test result after filteration of oil in proper proforma duly signed.Complete all as specified & directed
Supply and fill Transformer oil with high viscosity, high resistance to oxidation & thermal stability all as specified and directed. MAKE-CASTROL/INDIAN OIL/HPCL
Suppy and fix in repair of breather with silica gel crystal (1 kg) type all as directed.
S & F epoxy Bushings for LT, 440 Volt side of the transformer for connecting outgoing cable with all the accessories including taking down old unserviceable bushings complete all as specified.
S & F epoxy Bushings for HT ,11000 Volt side of the transformer for incoming cable with all the accessories including taking down old unserviceable bushings complete all as specified.
Taking down the HT vacuum circuit breaker of any make, capacity from 400-630 Amps, 11 KV, 800 Amps for servicing, repairs and re-assembling complete comprising of the following including testing and commissioning all as directed. (a) Checking the serviceability of all parts, cleaning, alignment of closing/opening mechanisms and re-assembling the unit complete and making it smooth functional. (b) Cleaning the external surface of bushings with CRC/ Tri-chloro-ethylene to remove the accumulation of carbon or any other deposits. (c) Checking the VCB panel wiring and repairing for making VC in fully functional condition . (d) Dismantling the spring charging mechanism of the VCB, checking the operations of the closing/tripping through closing/tripping coils electrically as well as manual charging including cleaning re-adjusting worn out parts etc. (e) Checking the condition of the spring charging motor along with gear box including providing servicing to the motor commutator bushes, lubrication of bearing surfaces etc. (f) Calibration of relays and meter of VCB, for making it fully functional and in earth fault, over current etc relay can be work and trip the VCB. (g) Inspecting all bolts, nuts, pins and ensure collar pins are in place and they are tight and opened properlycomplete all as specified and directed by EIC up to his full satisfaction.
Pumping out sewage water from the existing sumps/tanks of 125 cum per day and 160 cum per day STPs with the help of Non clogging of pump any kind capacity of pump set not less than 1500 LPM capacity 10HP/15 HP (Minimum) along with tanking out mud/ solid sludge from the tank complete from soild sepration chamber, aeration chamber and despose whole sludge to faraway areas from public places including cleaning of sump completely. So as to vacate the sumps to enable the repair of the non clogging pump sets installed in the STPs, complete all as specified and as directed by Engineer-in-Charge. Note :- (a) Pumping shall be continued till the main pumps installed in STPs sump is cleared for carrying out repair work. (b) Delivery pipe should be connected and the sewage water shall be thrown in the manhole of out side the fencing /wall of STPs towards the main gravity dropping main hole. (c) Pumping of sewage water still be continued till the sumps are fully empty and to keep till the installed non clogging pump are repaired & fully operative. (d) Necessary man power to operate the pump set are deemed to be included in the rate. (e) Rate quoted is deemed to include for Diesel/Engine oil till completion of repair work including testing of sewage pump set. (f) Rate included for transportation of pump set to site/back.
Lifting the non clogging submersible pump set electrically operated by 3 HP 3 Phase motor incl column pipe, line shaft etc after disconnecting of all electric and water line connection for the any make of pump & motor complete as directed.
Dismantling of non clogging submersible pump of capacity 3.0 HP and taking out burnout winding from the stator of motor and rewinding with PVC copper wire as per existing gauge incl connection commissioning & testing , complete all as specified and as directed by Engineer-in-Charge. Note: Super enameled copper winding wire of existing gauge paid and measure seprately.
Lowering complete the non clogging pumping set and reflixing the motor carefully including connection and testing, complete all as specified and as directed by Engineer-in-Charge.
Dismantling of electric sewage induction motor 3.0 HP, AC, 3 phase, 415 volts from site after disconnecting from pump & electric connection for rewinding, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, cleaning the slots properly and rewinding with supper enamelled copper wire as per existing gauge and varnishing complete, and reassembling after repairs and replacement of parts as required, refixing the same at site and connecting the electric connection with existing cable etc and including painting of external portion of pump with synthetic enamel paint (1 st quality) of two coat after one coat priming of red oxide primer and testing for satisfatory working of pump , complete all as specified and as directed by Engineer-in-Charge. Note: Super enameled copper winding wire of existing gauge paid and measure seprately under items no. 26.
Dismantling Non clogging pump set of centrifugal type (3.0 HP induction motor), AC, 3 phase, 415 volts from site after disconnecting of suction and delivery line, taking out to work shop, dismantling pump set for overhauling, replacing u/s shaft sleeve, gland packing, bush, water seal, applying grease etc reassembling the pump set and refixing back at site on the base plate and connecting existing pipe line with nuts, bolts and new gasket, connecting the electric connection with existing cable etc and including painting of external portion of pump with synthetic enamel paint (1 st quality) of two coat after one coat priming of red oxide primer and testing for satisfatory working of pump , complete all as specified and as directed by Engineer-in-Charge.
Dismantling of electric induction blower motor 5.0 HP, AC, 3 phase, 415 volts from site after disconnecting from blower & electric connection for rewinding, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, cleaning the slots properly and rewinding with supper enamelled copper wire as per existing gauge and varnishing complete, and reassembling after repairs and replacement of parts as required, refixing the same at site and connecting the electric connection with existing cable etc and including painting of external portion of pump with synthetic enamel paint (1 st quality) of two coat after one coat priming of red oxide primer and testing for satisfatory working of pump , complete all as specified and as directed by Engineer-in-Charge. Note: Super enameled copper winding wire of existing gauge paid and measure seprately.
M&L for taking out & servicing of existing unserviceable Air Blower (of any Make ) of capacity 125 Cubic/Hr to 188 Cubic /Hr with taking out of electric cable complete and reconnecting the electric and mechanical connection at existing location after carrying out following repairs all as specified and directed by Engineer-in- charge. Note- (i) Spare part required for replacement shall be measured and paid separetly under relevent items (ii) Replacement of Oil seal, locking arrangement of pully, gland packing with oil and greasing shall be deemed to be including in the quoted rate of this item.
Supply only Gear oil EP 90, complete all as specified and as directed by Engineer-in-Charge.
Supply only Air filter suitable for existing one, complete all as specified and as directed by Engineer-in-Charge.
Supply only belt as per existing model, complete all as specified and as directed by Engineer-in-Charge.
Supply only bearing as per existing, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement PVC insulated & PVC Sheathed three core cable of size 2.5 sqmm with copper conductor 1100 Volts grade conforming to IS:694/1990 ISI all as specified and directed.
Supply and fix in repair's flexible flat PVC insulated PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 4 Sqmm 3 core including jointing material and connection work, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair's, flexible flat PVC insulated PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 10 Sqmm 3 core including jointing material and connection work, complete all as specified and as directed by Engineer-in-Charge.
Testing of Sewage Water Samples for BOD annd COD testing analysis as mentioned below from STPs viz 125 cum per day and 160 cum per day complete all as specified and as directed. (a) BOD (b) COD (c) PH Level (d) Total Suspended Soild(TSS) (e) Outlet Coliform Note: Testing of Sewage Water for total 02 STPs in three month Basis.(i.e Treated Sewage water in Each STPs consider as one Job) (a) Sample of Sewage Water for the above media test are to collected in transparent container/Jar/bottle separately for each test against each STPs. (Hygienically clean bottles). (b) Sample of water to be collected shall be forwarded to Govt Lab / any NABL certified authorized Lab.
S&F Start Push Button as per existing after taking out old U/S , complete all as specified and as directed by Engineer-in-Charge.
S&F Stop Push Button as per existing after taking out old U/S , complete all as specified and as directed by Engineer-in-Charge.
S&F Pressure gauge for blower as per existing fter taking out old unserviceable one, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair's Butterfly valve PN-1.0, 50 mm dia use in STPs , complete all as specified and as directed by Engineer-in-Charge.
Suplly and fixing Plastic MBBR Filter Bio media for sewage water treatment of size 25x12 mm black in colour , complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing 2 HP submersible non clogging pump set of 3 phase, 50 Hz along with 4 sqmm 3 core submerible cable (20 mtr length ) all as specified and as directed.
Material and labour for Dismantling of old unservicable Direct online starter and Supply and fixing for Direct online starter for induction motor Pump set of rating 5 HP, 415 volts, 50 Hz having with sheet metal encloser range 3 phase 9 to 14 Amps rating panel mounting complete all as specified and directed.
Supply super enameled copper winding wire of existing gauge for above 3.0 HP to 30 HP submersible and Centrifugal motor.
Opening completely dual media pressure filter chamber of STPs and taking out existing filter media (sand, gravells, pebbles, Anthracite) stainers , removing and depositing filter media to a distance not exceeding 50 m and including necessary repair/welding to make the pressure filter vessels complete leak proof for improving the strength and finally reassembling the pressure filter including filling of new gravles, sand, Pebbles, strainer and Anthracite in existing position duly cleaned replacing worn out gasket and nut bolts and washers complete all as directed. (Note- New Gravels, Pebbles, strianer, anthracite including in above quoted rate)
Opening completely Activated carbon filter chamber of STPs and taking out existing filter media (Activated Carbon) removing and depositing filter media to a distance not exceeding 50 m and including necessary repair/welding to make the pressure filter vessels complete leak proof for improving the strength and finally reassembling the pressure filter including filling of new Activated carbon media in existing position duly cleaned replacing worn out gasket and nut bolts and washers complete all as directed. (Note- New Activated Carbon media including in above quoted rate)
Supply, installation, testing and commissioning of factory made approved make as specified in PS,powder coated outdoor type, dust & vermin proof feeder pillar box made out of 3.15mm CRCA steel sheet of suitable size and angle iron 40 mm x 40mm x 6 mm , powder coated over one coat of red oxide primer suitably grouted in PCC-M10 using 20 mm graded stone aggregate including aluminum bus bar, internal wiring with PVC insulated single core cables of copper conductor of suitable size duly numbered with tags for the circuits with hinged double door shutters (front & rear), cubical type locking arrangement and slanted roof. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system. The panel board shall comprise of following items & all specified INCOMING:- (i) MCCB 100 amps, 4 pole, breaking capacity 25 KA suitable for operation of 415 volts AC 50 HZ with adjustable type and all as specified - 01 No, (ii) LED Type indicator lamp R-Y-B (1 Set), (iii) 4 strip aluminum coated copper bus bar of rating 1.5 times current carrying capacity of incoming switch gear or not less than 200 Amp whichever higher(i.e 300 Amps) (iv) Voltmeter and ammeter (B) OUTGOING (i) MCB 6-32 Amp, 2 Pole, 415 Volts, 10 KA, C Curve - 4 Nos (II) MCB TPN 40 Amp-03 Nos (iii) Direct online starter(DOL) for induction motor Pump set of rating 5 HP, 415 volts, 50 Hz, 3 phase 9 to 14 Amps rating complete- 08 Nos Note: Rate of PCC foundation for installation of panel shall be included in the quoted rate.
S&F in replacement of heating element of 2000 W (Round or Triangular Head as required at site) including rubber washer (ISI marked) etc complete all as directed
S&F in replacement of 450 mm long PVC connection suitable for hot & cold water supply with cromium plated brass screwed nuts at both ends with washers for making water connection of inlet & outlet from geyser to GI pipe 15 mm dia complete all as directed.
S&F in replacement of thermostat suitable for water heater of any size/type complete all as directed.
S&F in replacement of plug top 3 pin 16 amps ISI marked complete all as directed
M&L for wall fastener of size 100 mm long, 8 mm dia with double washers grouting making good in walls cement mortar (1:4) for fixing water heater, spilit AC outdoor after removing the existing unserviceable nuts /bolts and washers complete all as specified and directed.
S&F in replacement of sealed unit compressor suitable for Refrigarator/Deep Freezer of capacity upto 320 ltrs including sealing of the compressor with welding after assembling complete all as directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.
S&F in replacement of sealed unit compressor suitable for water cooler of capacity 40/80 Ltrs including sealing of the compressor with welding after assembling complete all as directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.
S&F in replacement of relay suitable for Refrigarator/ Deep Freezer/water Cooler of any capacity complete all as specified and directed.
S&F in replacement of evaporator coil unit complete suitable for Refrigarator/Deep Freezer of any capacity complete all as specified and directed.
S&F in replacement of tap chromium plated 15 mm dia suitable for water cooler all as specified and directed.
S&F in replacement of filter stainer of suitable for Refrigarator/Deep Freezer/water cooler/AC of any capacity all as specified and directed.
S&F in replacement of overload protector for Refrigerator/Deep Freezer/water coolers/AC all as specified and directed.
S&F in replacement of capacitor 6 MFD for AC/water cooler/Deep Freezer/Refrigerator complete all as specified and directed.
Supply and fix in replacement of ice chamber cabinet of Refrigerator of capacity upto 320 ltrs complete all as specified and directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.
M&L for leak testing with nitrogen dioxide and refilling with refrigerant R-134a as required for Refrigarator/Water Cooler/Deep Freezer and testing the cooling effect satisfactorily on full load. The filling of gas & testing shall be carried out in the presence of Engineer in Charge complete all as directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.
S&F in replacement of thermatically sealed compressor including sealing of the compressor with welding after assembling for 1.5/2.0 Ton Capacity Spilit type AC/ Window type AC complete all as specified and directed.
S&F in replacement of running capacitor 36-45 MFD for window type/Split type AC 1.5/2.0 Ton capacity complete all as specified and directed.
S&F in replacement of starting capacitor 80-120 MFD for window type/split type air conditioner 1.5/2.0 Ton capacity complete all as specified and directed.
S&F in replacement of box type relay suitable for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed.
S&F in replacement of copper condencer coil unit complete for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed.
S&F in replacement of capilary tube suitable for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed..
S&F in replacement of fan blade with blower motor of window/split type AC 1.5/2.0 Ton, Refrigerator, deep freezer, water cooler capacity complete all as specified and directed.
S&F in replacement of control circuit (PCB) with remote device suitable for 1.5/2.0 Ton Split type AC complete all as specified and directed.
S&F in replacement of copper tube of size 1/2'' dia for connection of indoor and outdoor unit of split AC/window AC all per directed by the Engineer-in-Charge.
S&F in replacement of copper tube of size 1/4'' dia for connection of indoor and outdoor unit of split AC all per directed by the Engineer-in-Charge.
S&F in replacement of insulation cover of size 5/8" for insulating copper tube of split type AC all per directed by the Engineer-in-Charge.
S&F in replacement of of flair nut for tighting the inlet valve of gas of desire size for connection of indoor and outdoor of split AC all per directed by the Engineer-in-Charge.
M&L for leak testing with nitrogen dioxide and refilling with refrigerant as required for Split AC/Window AC and testing the cooling effect satisfactorily on full load and the filling of gas & testing shall be carried out in the presence of Engineer in Charge complete all as directed.
M&L for Shifting Split type AC 1.5/2.0 TR capacity including disconnection of out door & indoor unit, Re installed the same to new location after necessary servicing including testing and commisioning complete all as directed.
S&F in replacement of AC support bracket of size 500x500 mm ('L' Shape) 2mm thickness suitable for carrying maximum load 200-250 Kg including necessary fixing arrangements for installation of outdoor unit of split type AC complete all as specified and directed.
S&F in replacement of Sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 32 Amps, 240 volts capacity and tested on completion complete all as specified and directed.
Supply and fix in replacement of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 290 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1.0 KVA all as specified and directed.
Supply and fix in replacement of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 290 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA all as specified and directed.
S&F in replacement of float valve assembly complete for water cooler 40/150 ltrs capacity water storage type all as specified and directed.
S&F in replacemet of water purifier stainer for pre filter of single candle complete all as directed.
M&L for servicing refrigerator/water cooler/depp freezer/air conditioner of any capacity after removing electric wire connection & cleaning of Cooling coil, Filter, etc. including testing to cooling complete to entire satisfaction of Engr-in-Charge.
S&F in replacement of indoor unit of spilt AC of capacity 1.5 Ton wall mounted as per existing make required at site complete all as specified and directed.
Taking down and Refixing at site ceiling fans 1200/1400 mm sweep including opening of fans and cutting down burnt winding, and rewinding with new super enameled copper winding of same gauge as per existing winding, varnishing, drying, replacement of ball bearing, replacement of condenser etc and re-assembling the same including necessary transportation etc complete including taking down all as specified and directed.
Material and Labour for overhauling/servicing of DG set of capacity 125 KVA all as per manufacturer instructions, carrying out the changing of oil filter, air filter, checking of nut, bolts, washers, gaskets, screws, hose clamps, including draining out old engine oil and filling in new engine oil, filling in/top up coolent in radiators of water cooled engine, taking out air filter element cleaning the same with compressed air for the removing the dust or replace unserviceable element with new element, cleaning of waste oil or coolent from engine complete testing after repair for its smooth functioning all as specifed and directed. Note : (i) Replacement of minor spare parts like nut, bolt shall be deemed in the quaoted rated. (ii) Oil filter, Air Filter, engine oil, coolent, distiled water and other required item will be paid under relevant item as supply only
Material and Labour for servicing of DG set of capacity 100 KVA all as per manufacturer instructions, carrying out the changing of oil filter, airf ilter, checking of nut, bolts, washers, gaskets, screws, hose clamps, including draining out old engine oil and filling in new engine oil, filling in/top up coolent in radiators of water cooled engine, taking out air filter element cleaning the same with compressed air for the removing the dust or replace unserviceable element with new element, cleaning of waste oil or coolent from engine complete testing after repair for its smooth functioning all as specifed and directed. Note : (i) Replacement of minor spare parts like nut, bolt, gasket, 'o' ring shall be deemed in the quaoted rated. (ii) Oil filter, Air Filter, engine oil, coolent, distiled water, will be paid under relevant item as supply only
Material and Labour for servicing of DG set of capacity 62.5 KVA all as per manufacturer instructions, carrying out the changing of oil filter, airf ilter, checking of nut, bolts, washers, gaskets, screws, hose clamps, including draining out old engine oil and filling in new engine oil, filling in/top up coolent in radiators of water cooled engine, taking out air filter element cleaning the same with compressed air for the removing the dust or replace unserviceable element with new element, cleaning of waste oil or coolent from engine complete testing after repair for its smooth functioning all as specifed and directed. Note : (i) Replacement of minor spare parts like nut, bolt, gasket, 'o' ring shall be deemed in the quaoted rated. (ii) Oil filter, Air Filter, engine oil, coolent, distilled water will be paid under relevant item as supply only
Material and Labour for servicing of DG set of capacity 40 KVA all as per manufacturer instructions, carrying out the changing of oil filter, airf ilter, checking of nut, bolts, washers, gaskets, screws, hose clamps, including draining out old engine oil and filling in new engine oil, filling in/top up coolent in radiators of water cooled engine, taking out air filter element cleaning the same with compressed air for the removing the dust or replace unserviceable element with new element, cleaning of waste oil or coolent from engine complete testing after repair for its smooth functioning all as specifed and directed. Note : (i) Replacement of minor spare parts like nut, bolt, gasket, 'o' ring shall be deemed in the quaoted rated. (ii) Oil filter, Air Filter, engine oil, coolent, distilled water will be paid under relevant item as supply only
M & L for repair/dismantling of 125 KVA DG Set by opening, checking, inspecting for repair work including replacement of unserviceable parts and externally cleaned complete all as directed by Engineer- in-Charge. Note:- (i) Spares parts listed below shall be measured and paid separately.
S&F in replacement of unservicable parts with the new one, conforming to their respective part Nos after dismantling the DG sets incorporated in the above item, and taking out the unservicable parts for the 125 KVA DG set ( 1 Nos). (a) Cylinder liner assembly
All as per Item No 119 but Piston
All as per Item No 119 but Piston Ring
All as per Item No 119 but CR bearing
All as per Item No 119 but Head Gasket
All as per Item No 119 but Valve inlet
All as per Item No 119 but Valve Guide.
All as per Item No 119 but Valve Exhaust
All as per Item No 119 but Oil seal assembly
All as per Item No 119 but Nozzle 'o' Ring
All as per Item No 119 but Hose pipe with clamps
All as per Item No 119 but Thrust Washer
All as per Item No 119 but Nozzle valve
All as per Item No 119 but Fuel pipe (inlet & outlet pair)
All as per Item No 119 but Flexible pipe
All as per Item No 119 but Thermostate valve
All as per Item No 119 but Plunzer fuel control
All as per Item No 119 but Lub oil pipe
M&L in replacement of automatic voltage regulator suitable for 40 KVA to 100 KVA DG set complete all as specified.
M&L for over haulaing out Fuel injector pump from DG set carefully, transportation of the same to civil work-shop for repair & complete service of FIP pump and calibration on automatic setting machine, shifting of FIP pump from civil work-shop to worksite and re-fixing the same to DG set and testing complete of range 40 KVA, 62.5 KVA,125 KVA complete all as specified.
Supply only Kirloskar premium engine oil as per manufacturers recommendation complete all as directed.
Supply only coolent "K' Care geniune for radiator of water cooled engines as per manufacturers recommendation complete as all directed.
Supply only Oil filter element
Supply only Air filter element
Supply only distilled water for battery or radiator of engine used with coolent complete all as directed.
Supply and fix in repair 'V' belt ribbed of (a) radiator fan belt, (b) battery charging dynomo belt, and (c) water pump belt all suitable for DG set all as specified and directed.
M&L for Painting of DG set of capacity 62.5 KVA and 125 KVA at different location inside Misa camp through spray painting with two coats of approved fire proof metal paint as specified and directed by Engr-in-Charge.
S&F in repair relay siutable for 125 KVA DG AMF Panel all as specified and directed.
M & L for finding out defects of DG set Control panel and Taking out burnt wiring including u/s and serviceable components for reuse including Rewiring of panel using existing size of copper cable, ferrule, lugs, insulating material, nut bolt washer of various sizes including testing complete.
Supply & fixing in repair of 150 AH Battery all as specified. Make:-Exide/Amaron/TATA Greens/V-Guard
Supply & fixing in repair of 88 AH Battery all as specified. Make:-Exide/Amaron/TATA Greens/V-Guard
Dismantling self starter of DG set for repairing the starter by replacing carbon brushes, brush holder, bearings, solenoid coil, replacement of burnt aremeture, rewinding of Fd coils, replace of pinion gears etc, completer servicing and refixing after repair, testing/commissioning complete for DG Set any capacity complete all as directed (Note : Replacement of solenoid coil, armeture coil, and pinion gear Shall be deemed in quoated rate)
Supply and fix in repair battery leads set appx 1.25 Mtr long, PVC insulated multistranded copper conductor 70 sqmm single core, duly fixed brass clamps, copper lugs for connections from DG battery to self starter on various DG Sets of any capacity installed complete all as directed.
Supply and fix in replacement on load change over switch AC-23 (side handle) with advance Neutral switch in steel sheet metal enclosure 4 pole By pass Switch and 415 volts conforming to IS/IEC -60947-3 compact design of capacity 63 Amps complete all as specified and directed. Make: L&T/Legrand / ABB / Siemens / GE / Schnieder / C&S Electric Ltd / Indo Asian Note 1:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount. Note 2-Contractor's supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embosed with contractor's firm name while carriying out any activities in defence area for better check of security purpose. Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .