Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.1 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹36.9 L+₹11,011.20 (0.30%)Rejected-AOC | L2 | Rejected-AOC Not being lowest bidder | |
| 3 | L3₹37.0 L+₹16,920 (0.46%)Rejected-AOC | L3 | Rejected-AOC Not being lowest bidder | |
| 4 | L4₹38.4 L+₹1.6 L (4.21%)Rejected-AOC | L4 | Rejected-AOC Not being lowest bidder | |
| 5 | L5₹38.7 L+₹1.9 L (5.27%)Rejected-AOC | L5 | Rejected-AOC Not being lowest bidder |
Tender Value
Refer Docs
EMD Value
₹83,000
Closing Date
1 Mar 2021, 6:00 pmClosed
GE I R nd D West Bengaluru
GARRISON ENGINEER I R nd D WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
OUTSOURCING SERVICES FOR OPERATION AND MAINTENANCE OF HT/LT INSTALLATIONS AND UPKEEPING OF INTERNAL ELECTRIFICATION IN RESIDENTIAL AREA AT SERVICE CENTRE NO 2 AT DRDO COMPLEX PHASE - I, C V RAMAN NAGAR, BANGALORE
2020_MES_406166_1
GE(I) R ND D (WEST)/BAN/61 OF 2020-21 8858E8
Open Tender
Manpower Supply
Item Rate
330 days
Bengaluru
Class and Category as per NIT
8 documents required · 8 mandatory
₹500
GE I R nd D West Bengaluru
₹83,000
Yes
19 Mar 2021
25 Jan 2021
8 Mar 2021
27 Jan 2021
1 Mar 2021
16 Feb 2021
27 Jan 2021 - 15 Feb 2021
Amount
Providing services for maintenance, operation and up keeping of HT & LT installations, switch gears, RMU/SF6 / load break units, power controlled, transformers, OCBs and VCBs, OH lines 4 pole structures, GODs, DO fuses, street lights controls, LT panel boards installed in Sub-station No 2, including fuse off call on all days including Sundays & Holidays to maintain the equipments as detailed here-in-after and as directed by Engineer - in - Charge. The quoted rate shall deemed to include for the following :- NOTES : i) Manning and Operating round the clock in three shifts on all days including Sundays and Holidays . (0600 Hrs to 1400 Hrs - Ist Shft, 1400 Hrs to 2200 Hrs - 2nd shift & 2200 Hrs to 0600 Hrs - 3rd shift); Skilled Person - 1 No, and Helper -1 No per shift . All the above tasks shall be performed by Electrician (skilled) possessing the requisite qualifications and experience in handling HT/LT installations. ii) Cleaning of working areas, equipments, sub stations building and maintenance of garden areas. iii) Proper records of all operating parameters in the prescribed log book/register shall be maintained by the contractor in the installation for periodical check by the Engineer-in-charge. iv) Absent from duty of technician is not permissible as E&M services are essential in nature. However, the absence will invite penalty as described in Sch 'A' notes and recovery shall be done through recovery statement from the payment due. The tenderer will have no claim whatsoever on this account and decision of Accepting officer in this regard will be final and binding.
Item No 1.00 (Contd.,) iv) Tenderer shall arrange insurance to his work-men and relevant proofs of the same shall be submitted to the department as and when demanded, the cost for the same is deemed to be included in the rate quoted. Responsibility of compliance of labour regulations in force lies with the tenderer. Attention is also invited to Labour Wages Act with regards to payment of wages to the individuals engaged under this work. Contractor shall make the payments to their staff / employees by Cheque or through NEFT in their Bank Account, and the particulars of same shall be submitted to the department while claiming any payment. No payments will be made, unless proof of payment of wages through bank account is submitted by the Contractor/firm while claiming bills. (vi) Provisions of statutory laws relating to minimum wages, EPF, EDLI, ESIC, Bonus, GST, CESS & other levies payable shall be strictly adhered to by the contractor. Attention is also drawn to minimum fair wages payable as notified (time to time) by Govt Of India / State Govt / Local body whichever is higher, including all taxes as applicable and quote their rates. Contractor shall not have any claim on account of misunderstanding / under quoting in this regards. The Contractor shall produce proof of wages, EPF, ESIC, Bonus paid against the respective workmen while claiming payments.
Rate Per Electrician (Skilled) per Shift of 8 Hours
Rate Per Helper per Shift of 8 Hours
Periodical checking and attending all types of complaints connected with internal electrification and maintenance of internal electrification comprising of periodical checking of power DBs including tightening of connections, changing of burnt-out terminals, MCBs, connectors etc., checking of earthing of the LT distribution system, periodical maintenance of earth pits including measurement of earth resistance, attending day-to-day complaints including checking and replacement of burnt-out and unserviceable items like wiring, connected fittings and fixtures, MCB DBs, ceiling fans, exhaust fans, replacement of tube rods of any wattage, choke, starters, point wiring, sub-main wiring, switch socket combination of any capacity, switches, fan regulators, capacitors, replacement of fuses, CFL bulbs, lamp holders etc., complete all as specified, in day time by deploying certified / skilled workers round the clock in Service center No. 2 and in fuse off call office, on all days including Sundays and holidays, complete all as specified and directed. NOTES - i) Manning and Operating in single shift on all days including Sundays and Holidays (from 0830 Hrs to 1730 Hrs) with Electrician (Skilled) - 1 No and Helper - 1 No per shift. All the above tasks shall be performed by skilled persons possessing the requisite qualifications. Contractor has to produce such certificate issued by the Government authorities to the Garrison Engineer for approval before commencement of work. ii) Tenderer shall arrange insurance to his work-men and relevant proofs of the same shall be submitted to the department as and when demanded, the cost for the same is deemed to be included in the rate quoted. Responsibility of compliance of labour regulations in force lies with the tenderer. The provision of statutory laws relating to minimum wages, EPF, ESIC payments shall be strictly adhered to by the contractor. Contractor’s attention is invited to Labour Wages Act with regards to payment of wages to the individuals engaged under this work. Contractor shall make the payments to their staff / employees by Cheque or through NEFT in their Bank Account, and the particulars of same shall be submitted to the department while claiming any payment. No payments will be made, unless proof of payment of wages through bank account is submitted by the Contractor/firm while claiming bills.
Sl Item No 2.00 (Contd.,) :- iii) Absent from duty of technician is not permissible as E&M services are essential in nature. However, the absence will invite penalty as described in Sch 'A' notes and recovery shall be done through recovery statement from payment due. The tenderer will have no claim whatsoever on this account and decision of Accepting officer in this regard will be final and binding. (iv) Provisions of statutory laws relating to minimum wages, EPF, EDLI, ESIC, Bonus, GST, Cess & other levies payable shall be strictly adhered to by the contractor. Attention is also drawn to minimum fair wages payable as notified (time to time) by Govt Of India / State Govt / Local body whichever is higher, including all taxes as applicable and quote their rates. Contractor shall not have any claim on account of misunderstanding / under quoting in this regards. The Contractor shall produce proof of wages, EPF, ESIC, Bonus paid against the respective workmen while claiming payments.
Rate Per Electrician (Skilled) per Shift of 8 Hours
Rate Per Helper per Shift of 8 Hours
Supply only PVC insulated, PVC unsheathed, multi-stranded heavy duty copper conductor cable of 1.5 sq.mm size, FRLS grade, complete all as specified and directed.
Supply only PVC insulated, PVC unsheathed, multi-stranded heavy duty copper conductor cable of 2.5 sq.mm size, FRLS grade, complete all as specified and directed.
Supply only PVC insulated, PVC unsheathed multi-stranded heavy duty copper conductor cable of 4.0 sq.mm size, FRLS grade, complete all as specified and directed.
Supply only PVC insulated, flexible copper cable, 23/0.0052, 3 core, 230 volts, complete all as specified and directed.
Supply only switch piano, flush type, 5/6 Amps single pole, 230 V, one-way, complete all as specified and directed.
Supply only switch piano, flush type, 5/6 Amps single pole, 230 V, two-way, complete all as specified and directed.
Supply only bell push, single pole, flush type, 230 V, 5 Amps, complete all as specified and directed.
Supply only switch socket combination, 3 & 2 pin, 5 A, 240 V, flush type, multipurpose, controlled by one switch, complete all as specified and directed.
Supply only switch socket combination, 3 & 2 pin, 15 A, 240 V, flush type, multipurpose, controlled by one switch, complete all as specified and directed.
Supply only fan regulator electronic type, 230 V, stepped type, 120 W complete all as specified and directed.
Supply only PVC, ceiling rose three terminals white bakelite type complete all as directed.
Supply only modular Switch, One module , One way, 5/6 Amps, 240 Volts all as specified and as directed.
Supply only modular Switch, One module , One way, 16 Amps, 240 Volts all as specified and as directed.
Supply only modular socket outlet, 6 Amps, Module 1, complete all as specified and directed.
Supply only modular socket outlet, 16 Amps, Module 2, complete all as specified and directed.
Supply only modular bell push switch, one module, single pole, 230 volts 5/6 Amps capacity all as specified
Supply only modular fan Regulator,120 W, electronic stepped type, 230 Volts 2 module, complete all as specified and as directed.
Supply only calling bell, ding-dong type, 230 V, single phase, complete all as specified and directed.
Supply only fan capacitor of 2.5 mfd for ceiling fan, single phase, 230 V, complete all as specified and directed.
Supply only fan capacitor of 4.0 mfd for ceiling fan, single phase, 230 V, complete all as specified and directed.
Supply only ceiling fan clamps for fixing of ceiling fans with rubber bushings, complete all as specified and directed.
Supply only tube light starter, 230 V, single phase, suitable for 20/40 W tube light fitting, complete all as specified and directed.
Supply only electronic choke 36/40 W for fitting, 230V, complete all as specified and directed.
Supply only electronic choke 18/20 W for fitting, 230V, complete all as specified and directed.
Supply only MCB, SP, 230 V, 6 to 32 Amps 'C' series, 50 Hz, 240 V, 10 kA, breaking capacity, complete all as specified.d.
Supply only MCB SPN, 230 V, 6 to 40 Amps 'C' series, 50 Hz, 240 V, 10 kA, breaking capacity, complete all as specified.
Supply only MCB, TPN, 415 V, 63 A, 'C' series, 50 Hz, 10 kA, breaking capacity, complete all as specified.
Supply only MCB TP 100 Amps, 415 Volts, AC, 50 Hz, 10 kA, breaking capacity, complete all as specified.
Supply only PVC casing/caping of 20mm size, complete all as specified and directed.
Supply only PVC casing/caping of 25 mm size, complete all as specified and directed.
Supply only FTL tube rod 36 W / 40 W, 1220mm length (4'), complete all as specified and directed.
Supply only FTL tube rod 18 W / 20 W, 610mm length (2'), complete all as specified and directed.
Supply only angle holder suitable for LED lamp 9/11 W, complete all as specified
Supply only decorative ultra slim aluminium square profile LED light fitting fixture, 20/22 Watt, with high lumen output, environmental friendly, energy efficient LED, with accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, integral drivers, complete with diffuser, polyester louver, with lamps, integrated electronic driver complete all as per cat No LUMILINEPLUSBS22WLED865SPCSS of make Havells or techno commercially equivalent makes specified here-in-after complete all as specified.
All as per Serial Item No 35 here-in-above, but of 9/10 Watt, all as per cat No LUMILINEBS9WLED865SPCwh of make Havells or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply only LED tube Rod with light fitting, 18/20 Watt with high lumen output, environmental friendly, energy efficient LED, electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, intergral drivers, Ultra bright glass, with very high efficacy suitable for installation in existing T8 fitting with G13 lamp holders, complete as per Cat No CRYSTAL 1213T8DSTL18WLED865SGLASS of make Havells or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply only outdoor type LED street light fittings with lamp, 60 W, energy saving and environmental friendly long life LED street ligh, epoxy powder coated, housing, enclosed with glass cover in frame with IP-65 protection and impact resistance of IK07 with high lumen output, with and including lamp and accessories, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, intergral drivers, fittings as per Cat No ENDURAPEARLNEOSL60WLED757SASYTOPC of make Havells or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply only MCCB TP, 63 Amps, 16KA breaking capacity, 415 Volts all as specified.
Supply only MCCB FP, 63 Amps, 16KA breaking capacity, 415 Volts all as specified.
Supply only MCCB FP, 100 Amps, 16 kA breaking capacity, 415 Volts, for by pass control all as specified.
Supply only MCCB FP, 200 Amps, 35/36 kA breaking capacity, 415 Volts, all as specified.
Supply only MCCB FP, 250 Amps, 35 / 36 kA breaking capacity, 415 Volts, all as specified.
Taking down unserviceable, ceiling fans, depositing same in AGE E/M Storeyard, Supply and fix, Ceiling fan BEE 5 star rated complete 1200mm sweep, energy efficient suitable to function on 230V, single phase, AC supply, white colour, with down rod 300mm long, capacitor 2.5 mfd, canopies, nuts, bolts and washers and connecting with and including provision of 3 core 1.5 sq.mm PVC sheathed flexible copper conductor from ceiling, writing MES number on ceiling fan motor complete all as specified and directed. MAKE:- Auro Plus of Crompton Greaves or techno-commercially equivalent model in BAJAJ / HAVELLS / USHA
Supply only heating coil of 2500 / 2000 Watt (suitable for geysers) of any type complete all as specified and as directed.
Supply only thermostatic switch suitable for geysers of any capacity and type complete all as specified and as directed.
Supply only Hot and Cold connection pipe 15/20mm dia 450mm long with couplers and washers on both sides of geysers as per Cat Part No F8070403 of CERA or tehcno commercial equivalent in ESS ESS / JAQUAR / HINDWARE / JOHNSON / MARC complete all as specified and as directed.
Excavation in trenches in hard / dense soil not exceeding 1.5 metre wide not exceeding 1.5 metre in depth; for laying of cables not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out , trimming sides, forming bottom surface to required level complete all as specified and as directed .
Returning filling with excavated soil, including spreading, leveling , watering and well ramming in layers not exceeding 25 cm in soil as directed .
Removing of excavated soil to a distance not exceeding 50 m & depositing where as directed at a level not exceeding 1.5m above starting point all as specified and as directed.
Sand cushioning in layers for cables in trenches / ducts for cable including consolidation complete all as specified and directed. NOTE: Punned thickness will be measured for payment purpose.
Bricks, sub class 'B' of old size 230 mm x 115 mm x 75 mm laid in trenches for cable protection all as specified and directed.
Material and labour for, Galvanized Iron tubing, light grade, 40 mm bore for protection of cable laid at road crossing / on pole including provision of clamps made of mild steel flat iron of size 25 x 5 mm, bolts, nuts, washers, etc., removal of old unserviceable pipes complete all as specified and directed.
Dismantling old steel tubular pole / RCC pole of any length, Supply, erect and connecting, Steel tubular swaged poles type 410 SP-22 (9 metres long), ISI marked, complete with CI base plate and finial taper plug, bolts, nuts & screws complete all as specified and directed. Note: Excavation and earthwork, PCC foundation, coping of poles shall be measured and paid separately under respective item. complete all as directed.
Material and labour for plain Cement Concrete (1:3:6), type C1, using 20 mm graded stone aggregates for coping of poles / plinth blocks of HT poles etc., including necessary form work and finishing the exposed surfaces even and smooth without using extra cement complete all as specified and directed.
Material and labour for, Plain cement concrete (1:4:8), type D2 ,using 40 mm graded stone aggregates for foundation of poles complete all as specified and directed.
Supply and lay cable XLPE insulated armoured LT cable 1100 volts grade of size 10 Sq mm 2 core, in trenches/ on walls / poles including suitable MS clamps for fixing if required, connecting, testing and commissioning including taking down or pulling out the existing unserviceable cable complete all as specified and as directed Notes:- Earthwork, sand filling, brick protection, lugs shall be measured and paid separately under relevant items of this schedule.
All as per item 57 here in before but of cable 25 sq mm 4 core
Supply and fix, FRP body, loop in / loop out boxes, of size not less than 250 mm x 200 mm x 105 mm (out door type), fitted on poles with suitable size clamps made out of MS flat iron of size 20 x 5 mm GI nuts, bolts and washers complete with 4 way 32 Amps (heavy duty) connector - 2 Nos, including provision of cable glands of suitable size including taking down the old unserviceable ones complete all as specified and directed. Make : Cat Part No GSJB 2520 of M/s Sintex or equivalent in HENSEL / HPL.
Solar Electricals and Electronics
B5BUILDING SOLUTIONS
Arunachaleswara enterprises
C R R CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .