Supply and Installation of Water Leakage Rectification and Terrace Waterproofing at Keltron Communication Complex Building Monvila Trivandrum
2026_KSEDC_854672_1
KSEDC/KCC/CMN/0061/25-26
Open Tender
Miscellaneous Works
Supply and Service
Trivandrum
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,100
Yes
₹23,000
Yes
14 Jul 2026
6 Jun 2026
22 Jun 2026
6 Jun 2026
20 Jun 2026
6 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Surface Preparation (Civil) | - | - | - | - |
| 2 | Demolishing existing weather shield (roof tiles, brick jelly, sand bed filling etc.) above RCC mother slab without disturbing the slab, including removal and disposal of debris, complete. | 745 | Sq.M | - | - |
| 3 | Leakage Rectification (Supply & Fix) | - | - | - | - |
| 4 | Providing and laying screed concrete over waterproofed RCC slab using M20 grade concrete with 12.5 mm nominal size aggregate, including nominal reinforcement with 10 mm dia bars @ 250 mm c/c both ways, minimum finished thickness 75 mm, laid to proper slope towards rainwater outlets, including all materials, labour, curing, finishing and incidental works complete. | 56 | Cu.M | - | - |
| 5 | Providing and applying chicken mesh plastering over top layer using galvanized chicken mesh and plastering with CM 1:4 mixed with SBR polymer @ 2% by weight of cement, including floating coat, finishing, curing and all incidental works complete. | 745 | Sq.M | - | - |
| 6 | Providing, fixing and properly connecting drain out / rainwater pipes and discharging into rainwater harvesting tank
/ designated drainage system, including all fittings, supports, jointing, testing and making good, complete. | 50 | RM | - | - |
| 7 | Terrace Waterproofing System (Supply & Install) | - | - | - | - |
| 8 | Apply one coat of Dr. Fixit Primeseal primer dilute with water in the ratio 2:1 spreading at the rate of 8.0 – 10.0 / Sq.mt
/ Litre in the SSD condition. Apply 1st coat of Dr. Fixit Roofseal Ultrawithout dilution spreading at the rate of 0.70/litre/Sq.mt/Coat until all surface is covered. Lay a 45 GSM Fibre glass mesh as a reinforcing material which is incorporated in the coating when the first coat is still in wet condition. Allow the first coat to dry for approximately 4-6 hours before applying the 2nd coat at 90° to the first coat. Ensure there are no pinholes or air bubbles on the membrane surface.
Apply second coat of Dr. Fixit Roofseal Ultrawithout dilution spreading at the rate of 0.70 litre / Sq.mt /Coat to achieve total dry film thickness of 850 to 1000 microns for stated coverage at the rate of 1.40 litre / Sq.mt in 2 coats | 745 | Sq.M | - | - |
| 9 | Testing & Validation | - | - | - | - |
| 10 | 48-hour Pond Testing to verify zero leakage post-application | 1 | LS | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.15 MB
Tender.pdf
Tender Documents • 1.13 MB
BOQ_1444448.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .