Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹7.1 L+₹62,201 (9.58%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹7.7 L+₹1.2 L (19.3%)Rejected-Finance JAISALMER RAJASTHAN 345001 INDIA UDYAM RJ 18 0001538 | JAISALMER | RAJASTHAN | 345001 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹7.8 L+₹1.3 L (19.4%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
7 Sept 2021, 6:00 pmClosed
AGE (I) R AND D JODHPUR
AGE (I) R AND D JODHPUR, Defence Laboratory, Ratanada Palace, Jodhpur-342011 (Raj)
COMPREHENSIVE REPAIR AND MAINT OF DG SETS AT DEFENCE LAB JODHPUR
2021_MES_468086_1
8444/E8
Open Tender
Civil Works
Item Rate
270 days
AGE (I) R AND D JODHPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹18,000
Yes
17 Sept 2021
14 Aug 2021
9 Sept 2021
14 Aug 2021
7 Sept 2021
24 Aug 2021
16 Aug 2021 - 23 Aug 2021
Amount
M&L, monthly Inspection, maintenance and servicing of DG set including alternator, electric panel board connection to DG set for routine check (A check) of DG set for smooth functioning and carrying out maintanance as directed as specified for the following DG sets :- (a) 750 KVA Capacity, Make: Kirlosker, Model:-KG1-750WS1- 01 Nos (h) Checking engine oil level and topping up as and when required . Note: (i) Oil shall be measures and paid separately (ii) Checking and adjusting the belt for tension and replacement of belt. Note : Belt shall be measured and paid seperately (iii) Checking of air filter element (iv) Checking of exhaust system for leakage including rectification. (v) Draining of sediment from fuel filter and fuel tank (vi) Cleaning of air cleaner element (vii) Checking engine alternator coupling, mounting bolts and alignment (viii) Tighting all nuts, bolts, in altenator terminal block (ix) Checking of alternator carbon brush and connections in alternator (x) Checking and tighting of all connection in DC control wiring.
M&L, monthly Inspection, maintenance and servicing of DG set including alternator, electric panel board connection to DG set for routine check (A check) of DG set for smooth functioning and carrying out maintanance as directed as specified for the following DG sets :- (a) 320 KVA Capacity, Make: Kirlosker(Jakson), Model:-KG320WS4 - 01 No Note: (i) Oil shall be measures and paid separately (ii) Checking and adjusting the belt for tension and replacement of belt. Note : Belt shall be measured and paid seperately (iii)Checking of air filter element (iv) Checking of exhaust system for leakage including rectification (v) Draining of sediment from fuel filter and fuel tank (vi) Cleaning of air cleaner element (vii) Checking engine alternator coupling, mounting bolts and alignment (viii) Tighting all nuts, bolts, in altenator terminal block (ix) Checking of alternator carbon brush and connections in alternator (x) Checking and tighting of all connection in DC control wiring.
M&L, monthly Inspection, maintenance and servicing of DG set including alternator, electric panel board connection to DG set for routine check (A check) of DG set for smooth functioning and carrying out maintanance as directed as specified for the following DG sets :- (a) 250 KVA Capacity, Make: Kirloskar,Model No:-NTA-855-G - 01 No Note: (i) Oil shall be measures and paid separately (ii) Checking and adjusting the belt for tension and replacement of belt. Note: Belt shall be measured and paid seperately (iii)Checking of air filter element (iv) Checking of exhaust system for leakage including rectification (v) Draining of sediment from fuel filter and fuel tank (vi) Cleaning of air cleaner element (vii) Checking engine alternator coupling, mounting bolts and alignment (viii) Tighting all nuts, bolts, in altenator terminal block (ix) Checking of alternator carbon brush and connections in alternator (x) Checking and tighting of all connection in DC control wiring.
M&L, monthly Inspection, maintenance and servicing of DG set including alternator, electric panel board connection to DG set for routine check (A check) of DG set for smooth functioning and carrying out maintanance as directed as specified for the following DG sets :- (a) 125 KVA Capacity, Make: Kirlosker, Model No:-KG125WS2 - 01 No Note: (i) Oil shall be measures and paid separately (ii) Checking and adjusting the belt for tension and replacement of belt. Note : Belt shall be measured and paid seperately (iii)Checking of air filter element (iv) Checking of exhaust system for leakage including rectification (v) Draining of sediment from fuel filter and fuel tank (vi) Cleaning of air cleaner element (vii) Checking engine alternator coupling, mounting bolts and alignment (viii) Tighting all nuts, bolts, in altenator terminal block (ix) Checking of alternator carbon brush and connections in alternator (x) Checking and tighting of all connection in DC control wiring.
M&L , monthly Inspection, maintenance and servicing of DG set including alternator, electric panel board connection to DG set for routine check (A check) of DG set for smooth functioning and carrying out maintanance as directed as specified for the following DG sets :- (a) 40 KVA Capacity,Make- Kirlosker(Jakson), Model:-KG1-40AS - 01 No Note: (i) Oil shall be measures and paid separately (ii) Checking and adjusting the belt for tension and replacement of belt. Note : Belt shall be measured and paid seperately (iii) Checking of air filter element (iv) Checking of exhaust system for leakage including rectification (v) Draining of sediment from fuel filter and fuel tank (vi) Cleaning of air cleaner element (vii) Checking engine alternator coupling, mounting bolts and alignment (viii) Tighting all nuts, bolts, in altenator terminal block (ix) Checking of alternator carbon brush and connections in alternator (x) Checking and tighting of all connection in DC control wiring.
M&L, required for Inspection, maintenance and servicing of DG set including alternator, electric panel board connection to DG set for routine check (B check) of DG set for smooth functioning and carrying out maintanance as directed as specified for the following DG sets :- Note:- (i) B-check once in Six month Or 250 HRs running of DG set whchever is earlier. (a) 750 KVA Capacity, Make: Kirlosker, Model:-KG1-750WS1- 01 Nos (b) 320 KVA Capacity, Make: Kirlosker(Jakson), Model:-KG320WS4 - 01 No (c) 250 KVA Capacity, Make: Kirloskar,Model No:-NTA-855-G - 01 No (d) 125 KVA Capacity, Make: Kirlosker, Model No:-KG125WS2 - 01 No (e) 40 KVA Capacity,Make- Kirlosker(Jakson), Model:-KG1-40AS - 01 No Note:- (i) Repeat the Activities of A-Check
Supply only Diesel filter (Primary & Secondary)suitable for 750 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only Diesel filter (Primary & Secondary) suitable for 320 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only Diesel filter (Primary & Secondary) suitable for 312.5 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only Diesel filter (Primary & Secondary) suitable for 250 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only Diesel filter (Primary & Secondary) suitable for 125 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only Diesel filter (Primary & Secondary) suitable for 40 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only Engine oil filter suitable for 750 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only Engine oil filter suitable for 320 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only Engine oil filter suitable for 312.5 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only Engine oil filter suitable for 250 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only Engine oil filter suitable for 125 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only Engine oil filter suitable for 40 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only Air cleaner elements inner and outer suitable for 750 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only Air cleaner elements inner and outer suitable for 320 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only Air cleaner elements inner and outer suitable for 312.5 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only Air cleaner elements inner and outer suitable for 250 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only Air cleaner elements inner and outer suitable for 125 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only Air cleaner elements inner and outer suitable for 40 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only Fuel water saperator suitable for 750 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only Fuel water saperator suitable for 320 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only Fuel water saperator suitable for 125 to 250 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply only Battery water with electrolyte mix complete all as specified and directed by Engineer in charge.
Supply only 1.50M battery lead with negative & positive brass terminals of suitable size, complete all as specified and directed by Engineer in charge.
Supply only V belt of 750 KVA DG set of suitable size, complete all as specified and directed by Engineer in charge.
Supply only V belt of 320 KVA DG set of suitable size, complete all as specified and directed by Engineer in charge.
Supply only V belt of 250 KVA DG set of suitable size, complete all as specified and directed by Engineer in charge.
Supply only V belt of 125 KVA DG set of suitable size, complete all as specified and directed by Engineer in charge.
Supply only V belt of 40 KVA DG set of suitable size, complete all as specified and directed by Engineer in charge.
Servicing and repair self starter 24 V for DG set incl replacement of parts such as corban brushes, solonaid, rotor,washer, nut, bolts etc assembling the same and testing complete all as specified and directed by Engineer in charge. .
Servicing and repair self starter 12 V for DG set incl replacement of parts such as corban brushes, solonaid, rotor,washer, nut, bolts etc assembling the same and testing complete all as specified and directed by Engineer in charge. .
Supply only DC 24V Stop Solenoid suitable for 250 KVA DG set, complete all as specified & directed by Engineer-in-Charge.
Supply only DC 12V Stop Solenoid suitable for 125 KVA DG set, complete all as specified & directed by Engineer-in-Charge.
Supply only DC 12V Stop Solenoid suitable for 40 KVA DG set, complete all as specified & directed by Engineer-in-Charge.
Supply only DG set starting current coil suitable for 250 KVA DG set, complete all as specified & directed by Engineer-in-Charge.
Supply only DG set starting current coil suitable for 125 KVA DG set, complete all as specified & directed by Engineer-in-Charge.
Supply only DG set starting current coil suitable for 40 KVA DG set, complete all as specified & directed by Engineer-in-Charge.
Supply only power controller of DG set of capacity 750 KVA, complete all as specified & directed by Engineer-in-Charge.
Supply only power controller of DG set of capacity 250 to 320 KVA, complete all as specified & directed by Engineer-in-Charge.
Supply only power controller of DG set of capacity 125 KVA, complete all as specified & directed by Engineer-in-Charge.
Supply only AVR for DG set having capacity 750 KVA complete all as specified and directed by Engineer in charge.
Supply only AVR for DG set having capacity 250 KVA to 320 KVA complete all as specified and directed by Engineer in charge.
Supply only AVR for DG set having capacity 40 KVA complete all as specified and directed by Engineer in charge.
Supply only AVR for DG set having capacity 125 KVA complete all as specified and directed by Engineer in charge.
Dismantling the radiator and fan from the engine for cleaning of copper tubes and cooling fins by using descaling solution and soldering, patch work including repair of water pump assembly and replacement of defective parts of water pump and re-assembliying,testing complete of 750 KVA DG set complete all as specified and directed by Engineer in charge.
Dismantling the radiator and fan from the engine for cleaning of copper tubes and cooling fins by using descaling solution and soldering, patch work including repair of water pump assembly and replacement of defective parts of water pump and re-assembliying,testing complete of 320/312.5 KVA DG set complete all as specified and directed by Engineer in charge.
Dismantling the radiator and fan from the engine for cleaning of copper tubes and cooling fins by using descaling solution and soldering, patch work including repair of water pump assembly and replacement of defective parts of water pump and re-assembliying,testing complete of 250 KVA DG set complete all as specified and directed by Engineer in charge.
Dismantling the radiator and fan from the engine for cleaning of copper tubes and cooling fins by using descaling solution and soldering, patch work including repair of water pump assembly and replacement of defective parts of water pump and re-assembliying,testing complete of 125 KVA DG set complete all as specified and directed by Engineer in charge.
Dismantling the radiator and fan from the engine for cleaning of copper tubes and cooling fins by using descaling solution and soldering, patch work including repair of water pump assembly and replacement of defective parts of water pump and re-assembliying,testing complete of 40 KVA DG set complete all as specified and directed by Engineer in charge.
Supply & fix in replacement of unserviceable battery 12 V, 150 with maintenance free battery 12 volt initially charged including taking down old unserviceable complete all as specified and directed by Engineer-in-charge. Make :- EXIDE / AMRON / LUMINOUS
Supply & fix in replacement of unserviceable battery 12 V, 180 AH with maintenance free battery 12 volt initially charged including taking down old unserviceable complete all as specified and directed by Engineer-in-charge. Make :- EXIDE / AMRON / LUMINOUS
Supply only in replacement of MCCB 4 POLE 25KA 100 Amps with adjustable thermal and magnetic release in existing panel the make should be of the same of existing MCCB to match with existing holes/surface including taking down old unserviceable complete all as specified and directed by engineer in charge.
Supply only in replacement of MCCB 4 POLE 25KA 160 Amps with adjustable thermal and magnetic release in existing panel the make should be of the same of existing MCCB to match with existing holes/surface including taking down old unserviceable complete all as specified and directed by engineer in charge.
Supply only in replacement of MCCB 4 POLE 25KA 200 Amps with adjustable thermal and magnetic release in existing panel the make should be of the same of existing MCCB to match with existing holes/surface including taking down old unserviceable complete all as specified and directed by engineer in charge.
Supply only in replacement of MCCB 4 POLE 25KA 250 Amps with adjustable thermal and magnetic release in existing panel the make should be of the same of existing MCCB to match with existing holes/surface including taking down old unserviceable complete all as specified and directed by engineer in charge.
Supply only shunt trip coil complete all as specified & directed by Engineer-in-Charge, complete all as specified and directed by Engineer-in-Charge.
Supply only over and under voltage relay complete all as specified & directed by Engineer-in-Charge.
Taking down existing earthing and M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized iron strip 32X6mm as earth lead all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm bore light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as specified and directed by Engineer-in-Charge. NOTE :(i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-( ii) Item includes the cost of GI strip up to 7.5m for protection of earth strip. Any variation in length beyond 7.50 m shall be measured separately. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
Ditto but using copper plate of 60cm x 60cm x 3.15mm thick electrode and 20x3mm earthing strip as earth lead, complete all as specified and directed by Engineer-in-Charge.
M&L opening AMF Panel of DG set, Cleaning of dust by using blower & cleaning agents. Checking/Detecting faults, Removing Faults, Re-wiring of old unserviceable wiring & Testing of Control Wiring complete as reqd and closing of AMF Panel after replacement of unserviceable parts and testing on completion of job on existing load etc complete all as specified and directed by Engineer-in-Charge. NOTE:- Un-serviceable parts shall be measured and paid separatly as supply only.
Supply only three pole contactor suitable for 40 KVA DG set, complete all as specified & directed by Engineer-in-Charge.
Supply only three pole contactor suitable for 125 KVA DG set, complete all as specified & directed by Engineer-in-Charge.
Supply only four pole contactor suitable for 320/312.5 KVA DG set, complete all as specified & directed by Engineer-in-Charge.
Supply only Auxiliary Relay 4 pin, 14 Pin 230V AC suitable for AMF Panel of DG Set, complete all as specified and directed by Engineer in charge.
Supply only Auxiliary Relay 4 pin, 14 Pin 24/12V DC suitable for AMF Panel of DG Set, complete all as specified and directed by Engineer in charge.
Supply only Auxiliary Relay 3 pin, 11 Pin 24/12V AC suitable for AMF Panel of DG Set, complete all as specified and directed by Engineer in charge.
Supply only indicator lamp set RYB for phase indications suitable for panel to match with the existing one, complete all as specified and directed by Engineer-in-Charge.
Supply only Axillary contractor 3 phase suitable for AMF Panel of DG Set as per existing specification and make, complete all as specified and directed by Engineer in charge.
Supply only volt meter 96 mm x 96 mm digital type 0 to 500 volts capacity complete all as specified and directed by engineer in charge.
Supply only Amp meter 96 mm x 96 mm digital type 0 to 100 amps capacity complete all as specified and directed by engineer in charge.
Supply only CT of rating for Amp meter complete all as specified and directed by engineer in charge.
Supply only push switch complete all as specified and directed by engineer in charge.
Repair of battery charger by replacing of / rectifying main transformer of 220/24 volt, battery cut out etc complete all as specified and directed by engineer in charge.
Supply & Fixing in repair HRC Fuse 400 Amp suitable for AMF/LT Panel including taking down old unserviceable, complete all as specified & directed by Engineer-in-Charge.
Supply only Coolent complete all as specified and directed by Engineer in charge. Make: K-cool/Indian oil/Volvoline
Supply and fixing in replacement oil temperature gauge including taking down old unserviceable complete all as specified & directed by Engineer-in-Charge.
Supply and fixing in replacement water temperature gauge including taking down old unserviceable, complete all as specified & directed by Engineer-in-Charge.
Supply only CT(100/5),Auto clear 1.0,VA burden 15VA complete all as specified and directed by Engineer in charge.
Supply and fixing in replacement Oil Pressure gauge including taking down old unserviceable, complete all as specified & directed by Engineer-in-Charge.(125 KVA DG Set)
Supply and fixing in replacement Oil Pressure gauge including taking down old unserviceable, complete all as specified & directed by Engineer-in-Charge.(250 KVA DG Set)
Supply and fixing in replacement Oil Pressure gauge including taking down old unserviceable, complete all as specified & directed by Engineer-in-Charge. (320/312.5 KVA DG Set)
Supply only Engine oil 20 W 40 turbo synthetic superior quality engine oil suitable for Kirloskar/cumins/Joyti DG Set complete all as specified and directed by Engineer in charge. (Note:-The make of engine oil used in DG Set should be as per recommendation of Manufacturer of DG Set)
M/s Bakiyalakshmi Enterprises
M/s Ramesh & Company
vinayandsons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .