Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹10.5 L+₹25,055 (2.44%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹11.4 L+₹1.1 L (11.0%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹12.6 L+₹2.3 L (22.9%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹13.1 L+₹2.9 L (27.9%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
19 Dec 2019, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-54/219-20 PROVISION OF CERTAIN E/M WORKS AND SHED AT SITE-IV KALPI UNDER GE (AF) AMBALA
2019_MES_300101_1
GE AF/AMB-54/2019-20
Open Tender
Civil Works
Item Rate
180 days
GE AF AMBALA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE AF AMBALA
₹26,000
Yes
3 Jan 2020
22 Nov 2019
21 Dec 2019
22 Nov 2019
19 Dec 2019
7 Dec 2019
Amount
Surface excavation not exceeding 30cm deep and averaging 15cm deep in soft / loose soil and getting out including taking out roots, shrubs etc, complete all as specified and as directed
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
Excavating in post holes (or similar holes) each not exceeding 0.5cum, returning, filling in, getting out in soft / loose soil and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm and removing surplus soil to a distance not exceeding 50m complete all as specified and as directed
M&L for hard core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, using broken stone or boulders complete all as specified and as directed
M&L for plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregates as in foundations, filling and mass concrete complete all as specified and as directed
M&L for plain cement concrete 1:2:4 (type B-2) using 40mm graded stone aggregate as in sub-bases, filling, etc. complete all as specified and as directed
M&L for preparing of new steel / metal surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, tint as approved complete all as specified and as directed
S&F steel work in tubular trusses including special shaped washers, etc. using ERW or induction butt welded tubes conforming to IS-1161-1979 structural grade 240 complete all as specified and as directed
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed at both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 10cm in length, dia of neck & shank 16mm complete all as specified and as directed
S&F in position aluminium-zinc colour coated high tensile alloy steel trap sheeting of 0.5 to 0.53mm thick, high rib, having 550 Mpa yeild strength BMT 0.45mm and zinc (galvanized) and aluminum combined coating of 150 gms/sqm (AZ-150) of 0.50mm TCT having top colour coat of regular modified polyester/silicon modified polyester/HDPE polyester of 18 to 20micron and back coat of 5 to7 micron epoxy primer fixes, RMR 1040 profile width 1125mm in roofing panels / sheeting complete as per manufacturer's instructions, all as specified and as directed Note: The sheet shall be fixed to MS angles with self drilling and self topping screws conforming to AS 3566 with moulded EPDM washers
Supply, laying, jointing, connecting and testing XLPE / PVC sheathed cable 1100V (earthed) grade, insulated, screwed PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor laid in trenches / fixed on walls, etc. complete all as specified and as directed of the following sizes:
3.5 core 70sqmm
2 core 10sqmm
2 core 6sqmm
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
S&F steel water tubing, 40mm bore, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for protection of electric clables complete all as specified and as directed
S&F flame proof switch 6A 240V SP rotary type complete all as specified and as directed
S&F flame proof MCB SPN 40A 240V 10kA complete all as specified and as directed
S&F flame proof MCB SP 6A 240V 10kA complete all as specified and as directed
S&F flame proof sheet metal enclosures for MCB distribution board 240V SPN 6 way double door, flushed inside the wall with rated busbar, die cast metal free from frictional sparking hazard, provided with cable termination accessories, having earth terminal inside junction boxes having sufficient space for housing cable terminals with double compression type nickel / chromium plated brass glands complete all as specified and as directed
S&F flame proof sheet metal enclosures for MCB distribution board 240V SPN 4 way double door, flushed inside the wall with rated busbar, die cast metal free from frictional sparking hazard, provided with cable termination accessories, having earth terminal inside junction boxes having sufficient space for housing cable terminals with double compression type nickel / chromium plated brass glands complete all as specified and as directed
S&F onload change over switch 415V 4P 63A with suitable enclosure complete all as specified and as directed
S&F flame proof LED luminaire, 230V suitable for operation voltage range 150V to 270V, fabricated out of die cast aluminium housing with toughened clear heat resistant well glass, cemented into retaining ring, fixed with suitable screws to main body suitable for mounting on poles/ ceiling / columns, etc. with suitable hinging / fastening devices viz. clamps, brackets, etc. all as required at site including LED lamp, connecting lead, 3 core 1.5sqmm, flexible copper multistranded conductor cable from ceiling rose / junction box to fitting complete all as specified and as directed of the following wattages:
M&L for point wiring with 1.5sqmm, single core, ZHFR PVC insulated, ISI marked, unsheathed cable 1100volts grade with multi-stranded copper conductor, drawn through and including metallic rigid steel conduit (ERW) not less than 20mm dia and conduit accessories concealed on walls, surface on ceiling etc., and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly, including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sunken box or pressed steel terminal boxes (1.6mm thick) with provision of 3mm thick plastic laminated sheet top cover complete all as specified and as directed for one light / exhaust fan / power points controlled by one 5/6A one way switch
Supply, installation, testing & commissioning of powder coated compartmentalized cubical LT feeder pillar box / panel, symetrical with overload, short circuit and earth fault protection, having fire barrier and bus bar chambers with 63A rated copper bus bar SPN, duly insulated with coloured PVC sleeves as per standard code, rigidly mounted on bakelite / DMC insulators (square / round with good insulation resistance), fabricated out of 3.15mm thick CRCA sheet steel, totally enclosed, dust proof, weather proof, vermin proof, single door with suitable locking arrangements and suitable for operation on 240V, 50Hz, 1 phase, 2 wire AC supply with gland plates, cable glands, lifting hooks, ventilating louvers, bus bars, inter connections, earthing, labeling electrical interlocking, suitable for termination of cables, mounted/fixed on and including MS angle iron stand /frame 40cm height from FFL, fabricated out of 2x25x4mm thick MS angle legs duly grouted in and including 100mm thick PCC 1:3:6 platform of suitable size (with 0.5m offset to all sides of panel/feeder), painting all exposed metal surfaces with two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer, including supply and fixing of under mentioned switch gears and accessories in the panel, complete all as specified and as directed Incoming MCB 63A SPN 240V 50Hz 10kA - 01No. Outgoing MCB 10A SP 240V 50Hz 10kA - 05Nos.
M&L for earthing using GI earthing wire 4mm dia with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI wire of size 4mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm madium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications complete all as specified and as directed Notes: (i) The cost of GI earth continuity wire with GI pipe 50mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
Raman Electric Trading Co
Swami Enterprises
R D Bansal
SYNDICATE BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .