Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.5 LAccepted-AOC H NO 670 SECTOR 10 PANCHKULA HRY 134115 | PANCHKULA | HARYANA | 134115 | L1 | Accepted-AOC ok | |
| 2 | L2₹37.7 L+₹347.50 (<0.01%)Rejected-AOC 0 0 NAGLA MALOO MOHAMMDABAD FARRUKHABAD FARRUKHABAD FARRUKHABAD UTTAR PRADESH 209625 | FARRUKHABAD | UTTAR PRADESH | 209625 | L2 | Rejected-AOC ok | |
| 3 | L3₹38.8 L+₹1.0 L (2.74%)Rejected-AOC INDEX NO E 1504 HQ CWE DEHRADUN 63 RAJA ROAD DEHRADUN | L3 | Rejected-AOC ok | |
| 4 | L4₹40.9 L+₹3.1 L (8.30%)Rejected-AOC 5D 32B GALI NO 8 VISHNU GARDEN TILAK NAGAR WEST DELHI 110018 | DELHI | WEST DELHI | DELHI | 110018 | L4 | Rejected-AOC ok | |
| 5 | L5₹41.4 L+₹3.7 L (9.78%)Rejected-AOC 1 259 CHUKKUWALA DEHRADUN UK | DEHRADUN | DEHRADUN | UTTARAKHAND | L5 | Rejected-AOC ok |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
28 Jan 2023, 6:00 pmClosed
CWE Dehradun
HQ CWE Dehradun
REPAIR/REPLACEMENT OF HARD STANDING, PATHWAY, SECURITY FENCE AND OTHER MISC WORKS UNDER AGE B/R-II OF GE DEHRADUN
2023_MES_573663_1
9778/DDN/E8
Open Tender
Civil Works
Item Rate
180 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Yes
GE Dehradun
₹90,000
Yes
13 Mar 2023
7 Jan 2023
30 Jan 2023
7 Jan 2023
28 Jan 2023
21 Jan 2023
Amount
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed.
Dismantling of chain link fencing wire mesh any type all as specified and directed.
Excavating in post holes (or similar holes) each n. exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding, 25cm watering and removing surplus soil to a distance n exc 50m and making good surface in any type of soil complete all as specified and as directed.
M&L for Cement concrete type C2 1:3:6 (40mm crusted stone graded aggregate) in foundations, filling and mass concrete as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed.
Supply only Chain link MS galvanised fencing any size or type weight not exc 4 Kg per square metre complete all as specified and directed.
Fixing only Chain link fencing including line wires, any mesh size and type to any type of standards rails straining bolts etc including provision of binding wire any size or type all as specified and directed.
S&F mild steel joist, channel, angle, or tee section, fixed independently, without connecting plates, etc. as in fencing post conforming to Fe 410 W (gde E-250 quality B) complete all as specified and directed.
S&F mild steel flat iron for securing of chain link fencing conforming to Fe 290 Gde E-165 in post and strut in fencing including fabrication i.e. cutting tops drilling holes notching for wire welding etc complete all as specified and directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 15cm but not.exc 22.5 cm long, diameter of neck not exc12 mm complete all as specified and directed.
M&L for preparation of new untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S & F for Acrylic 2-3mm thick PVC sheet in any colour for fencing for Garden, balconies etc complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L brick work with sub class 'B’ brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 including demolition of existing old brick work or stone masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L brick work except brick with sub class 'B’ brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 including demolition of existing old brick work or stone masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified
M&L for walling of random rubble, uncoursed, well bounded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed.
All as per Item No -15 above but except stone.
M&L for flush pointing to block in course or ashlar masonry or concrete block walling to random rubble masonry un coursed or brought up to course in cement ratio 1: 4 complete all as specified and directed.
M&L for Cement concrete 1:2:4 B-0 (using 12.5 mm graded stone aggregate) in coping, bed plates and chamfered angles and throating etc complete all as specified and directed.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar work/places, laid in alternate bays and filling the joints with & including bitumen and sand mixer 1:3 by weight, surface finished even and fair without using extra cement complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in sub base complete all as specified and as directed.
M & L for 25 mm thick PCC 1:2:4 type B-1 using 12.50 mm graded aggregate as in flooring, finished even and smooth without using extra cement complete all as specified and directed.
M&L for factory made pre-polished rubber moulded vibromatic Chequred cement concrete tiles of size 30cmx30cm and 22-25mm thick, set jointed and pointed in neat cement slurry with grey cement and colour pigment to match over and including 15mm thick screed bedding layer in CM (1:6) complete all as specified and directed.
M&L for sand filling under floors or in foundations including complete all as specified and as directed.
M&L for 60 mm thick pre-polished rubber moulded coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658- 2006 M-35 Grade with grey cement and no pigment complete all as specified and directed.
M&L for heavy duty endura ceramic coloured tiles 10 mm thick dark shade (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floor etc. Set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 and dismantling of existing floor tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished surfaces even and smooth complete all as specified and as directed.
M&L for preparation of newly plastered surface of wall and applying two coat of cement base paint over a coat of alkali resistance primer complete all as specified and directed.
M&L for three coats of white wash on newly plastered surfaces of walls including preparation of surfaces complete all as specified and directed.
M & L stone kerb of roughly squared stones of size 20cmx30cm, dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 6 mm for top and exposed surface of side and 20mm for the rest of surfaces joined in cement mortar 1: 6 and struck flush complete all as specified and directed.
M&L for preparation of concrete surface of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint of approved tint complete all as specified and directed.
S&F in repair aluminum alloy powder coated door made out of hollow extruded aluminum section as mentioned below. Each door having 02 Nos Disc or D type handle, 02 Nos aluminum tower bolt 200 mm size, one brass mortice lock of six lever with key in duplicate regulated by double action hydraulic floor spring heavy duty (Make:- Sandhu/Ritz) shutter to be partly glaze with 5mm thick tined coloured glass in upper panel and partly paneled with 12mm thick both side laminated particle board in lower panel fixed with glazing clip, rubber beading/gasket, anodised aluminum beading screw complete all as specified and directed at site. Chowkhat Frame: - 101.60x44.45x3.00 mm Shutter vertical style :- 85x44.45x3.00mm shutter middle Rail :- 83.50x44.45x3.00mm Shutter Top Rail and bottom Rail :- 114.30x44.45x3.00mm
S&F in repair aluminum alloy powder coated standard hollow section as mentioned below window frame (Bombay sliding) with two glazed shutter and one Nos wire gauged shutter sliding type, with aluminum sections as per Series-A(15mm) 3 track of Jindal section numbers for sliding windows, and glazed with tinted glass coloured glass 4mm thick, fixed with glazing clips, rubber beading / gasket anodised beading, screw and lock type handle of size 75mm, 2 Nos aluminum tower bolt 150mm long etc complete all as specified and directed. Shutter Top & bottom size: 37.50x15x3.00mm Shutter inner lock size 37.50x15x3.00 mm Shutter side (Handle) size 37.50x15x3.00 mm Chowkhat bottom size : 50.30x26x3.00mm Chowkhat top & sides size: 50.30x26x3.00mm .
S&F in repair powder coated Aluminium partition (Fixed) made out of aluminium powder coated section 83 x 44.45 x 3.00 mm including 5 mm thick glass/ACP Sheet complete with rubber packing/aluminum beading etc including dismantling of existing structure complete all as specified and directed.
S&F Vanishing blinds Zebra Roller Cord Drawn (Polyester) horizontal type strip of approved colour weight not less than 2 kg/Sqm complete all as specified and directed.
Taking down chowkat with shutter exc 1.5 Sqm but n. exc 4 Sqm each complete all as specified and directed.
Taking down wall and ceiling linings, boards (fiber, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed by the Engr-In-charge
M&L for Solid/hollow PVC wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and as directed by Engr-in-Charge.
Providing & fixing in repair false ceiling of Designer tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grams, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm
made from 0.30mm thick sheet spaced at 1200mm c/c and cross 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable wire of 2mm dia with galvanised butterfly level clips, spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm of all 'T'' sections of 4mm dia GI wire shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, including taking down existing ceiling of any type all complete at all heights complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement motor bedding (But not backing), removing serviceable tiles to stone and rubbish off the premises complete all as specified and directed.
M&L non-skid / mat finish designed coloured joint free ceramic tiles of size not less than 400 mm x 400 mm x 7-8 mm thick in floor, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed in cement mortar 1:6 and dismantling of existing tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
M&L for coloured Glazed ceramic tiles in vertical surfaces of size 300mm x600mm x 7mm/ 450x 350 x 7mm thick over and including 10 mm thick bedding layer in CM 1:4 , set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for Vitrified Ceramic tiles Dark shed /double charged 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. including screed bed 15 mm thick in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match with tile shade complete all as specified and directed.
Description same as per item No- 44 above but as in skirting including 10 mm thick rendering in cement mortar 1:4, complete all as specified and directed.
Dismantling of stone slabs and tiles laid, bedded in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed.
M&L for 19-20 mm thick Granite, of any type, table rubbed and polished in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified including moulding complete all as specified and directed.
M&L for stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed.
M&L for grinding, rubbing and polishing of old existing kota/Marble / terazzo floor/dado etc to achieve granite finish complete all as specified and directed.
Dismantling timber scantling 40 sqcm and over in section, in any position unframed/ framed work complete all as specified and directed
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed
S&F mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, hollow section or flat sections) including distance pieces, cleats etc. Fe 410-W(Gde E-250) quality-A complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick AZ 70 of an ecofriendly colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws complete all as specified & directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick AZ 70 of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws complete all as specified and as directed.
M & L for Carpet tiles also known as moulder carpets or square carpets, are square cut from wall to wall rolls which can be fitted together with solvent adhesive to make up a carpet size of tiles 500x500mmx10mm thick, 600mmx600mm x10mm thick, and 960mm x960mmx10mm thick. complete all as specified and directed.
M & L for polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: - 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with
emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) s complete all as specified and directed. complete all as specified and directed.
M&L for pressure nipple grouting in swimming pool minimum depth 2.5 to 4.50 mtr with Arda SBR-50 mix with cement ration 1:2, the work shall be executed by manufacture or authorised applicator complete all as specified & directed.
M&L for water proofing treatment at swimming pool using with CHRYSO TPELASTIC Two Part Acrylic Polymer Based water coating two coat ASTM-D638 tensile strength N/mm2 ASTM D638 Ratio 1:2:5 the work shall be executed by manufacture or authorized applicator complete all as specified & directed.
S & F for brass nozzle of 15 mm to 20mm dia pipe for fountain any type, any size complete fixing with necessary GI tubing/GI connection & 0.50 HP submersible motor pump as required (Max. 5 to 7 Nozzle fixed with 1 in 0.50 HP motor) complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified & directed.
Supply and Installation of Canadian maple wood sports flooring system for Squash court (Flooring specification are given below) complete all as specified and directed. SURFACE BOARD :Canadian Maple wood sports flooring finished with 21mm thick, 57 to 83mm wide and in random length in tongue and groove shape . The edges of the boards will have a finger lock groove and the bottom side with air pass groove treated with special anti-termite and water-resistant lacquer.
THE UNDER FRAME : Made of commercial quality Canadian Pine wood runner of 70mm x 45mm, treated with anti-termite solution and fixed on the bottom side with 10mm thick EPDM air cushioned pads, the two wings at 350mm x 350mm. INSTALLATION : IPS subfloor treated with a vapour barrier to be placed on the levelled IPS sub-floor before laying the under frame. The runners having air cushion pads to be placed on the vapour barrier in perfect level at 350mm in 1 direction. The surface board to be screwed to the runner through the tongue only and will lock the screwed tongue by the groove of adjoining board. Ends of the boards will be locked by inserting the wooden fingers through the edge grooves and fixed with suitable adhesive. An expansion of 8 to 10mm to be left open between the wooden flooring and the surrounding tiled area/walls. FINISHING: After installation the floor will be machine shaded in uniform level and finished with P.U polishing water based polyurethane lacquer. Game line marking to be carried out in required colours before applying the finish coat.
Supply & applying Squash court Bounce Wall Hard Plaster system as per international standard.( complete specification given below):- The system consists of a 10-12mm base coat with sand and cement provide by client at your cost and top coat of 5mm, which makes it a total thickness of 15-17mm. Due to extremely hard nature of plaster a slight uneven color distribution may be seen once the plaster has dried, this doesn't affect the strength or integrity of the plaster and must not be considered as defect.
M & L for providing and applying APEX Ultima paint in squash court wall painting color: WHITE in between RED game line marking as per site requirement complete all as specified.
Supply & Installation of Squash court Glass Back/wall system as per international standard (Glass Backwall as per WSF specification) Specification are given below: - GLASS BACK WALL SYSTEM: Free standing glass wall made of 12mm thick toughened glass with 4 panels, 1 door, 4 fines, fixtures and fittings and all the materials required for erecting the glass walls. The height of the glass will be 2130mm above the finished floor level complete all as specified and directed.
Supply & installation of Squash court Sound Board as per WSF Specification complete all as specified and directed.
M & L for providing & applying RED color PU paint on wall surface & wooden flooring surface of squash court complete all as specified and directed.
M&L for applying two coat of rough and tough exterior weather proof paint on dholpur stone smooth emulsion with silicon additives that offer anti alge high performance exterior wall finish with 6 years of performance warranty by manufacturer applied by using Airless spray technology with max working pressure of 3300 PPSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacture with pro guard technology and capable of tracking pressure and paint usage as certified by paint manufacturer and as mentioned in PS for applying exterior weather proof acrylic emulsion , should be able to spray in hard to reach areas and penetration of exterior weather proof acrylic emulsion on the surface to achieve excellent application using limited manpower complete all as specified and directed.
Supply and application of sport flooring for court with hybrid water borne PU top coating which adorable required minimum maintenance all weather suitable/ ecofriendly protective against UV rays consist of following layers: M&L for grinding and repairing of court with micro concrete including 2x2 mtr grove cutting 1.5 deep and one layer fiber glass mesh. One layer of primer is done on top of it with two layer of re surfacer and three layer of rubber cushion and two layer of colour sand mix paints with one layer of top coat paints and one layer of court marking complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for refixing with all fittings for 15 mm bore GI tubing complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for refixing with all fittings for 20 mm bore GI tubing complete all as specified and directed.
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 15 mm bore GI tubing complete all as specified and directed.
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 20 mm bore GI tubing complete all as specified and directed.
V S ENTERPRISES
Amit Traders
ANANYA CONSTRUCTION CO.
Sharda Enterprises
M/S RAJESH AGARWAL
Shree Durgai Construction Co.
jmd engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .