| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC | ₹7.6 L | L1 | Accepted-AOC L1 |
| 2 | L2₹8.3 L+₹70,380 (9.26%)Rejected-Finance | ₹8.3 L+₹70,380 (9.26%) | L2 | Rejected-Finance L2 |
| 3 | L3₹11.5 L+₹3.9 L (51.4%)Rejected-Finance JOYNAGAR MIDDLE ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | ₹11.5 L+₹3.9 L (51.4%) | L3 | Rejected-Finance L3 |
Tender Value
₹10.2 L
EMD Value
₹20,381
Closing Date
24 Feb 2025, 3:00 pmClosed
Executive Engineer, Mechanical Division,PWD, Aga
Executive Engineer, Mechanical Division,PWD, Agartala
Annual maintenance of AC system installed at Sonartori State Guest House, Agartala,Tripura for 02 year
2025_CEPWD_58493_1
92/EE/DNIeT/MECH.DIVN/AGT/2024
Open Tender
Electrical Works
Works
730 days
AGARTALA
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹20,381
4 Aug 2025
15 Feb 2025
24 Feb 2025
15 Feb 2025
24 Feb 2025
15 Feb 2025
Amount
Complete servicing of AC machines (Indoor & Outdoor Unit) as per direction of the Engineer-in-charge.
(I)1.0/1.2/1.5/2.0 TR split type AC.
(II)2.5/3.0/4.0/4.5 TR High wall Split, cassette and vertical AC
Leak testing of condenser & evaporator unit for performance and pressure testing etc and repair with brazing as per direction of the Engineer-in-charge. (I)1.0/1.2/1.5/2.0 High wall split and window type AC.
(II)2.5/3.0/4.5 TR High wall split, cassette and vertical type AC
Charging of fresh refrigerant gas (R-22) for 1.0/1.2/1.5/2.0/3.0/4.0 TR capacity High wall split/window/cassette / vertical AC system as per direction of the Engineer-in-charge.
Charging of fresh refrigerant gas (R-32) for 1.0/1.2/1.5/2.0/3.0/4.0 TR capacity High wall split/window/cassette / vertical AC system as per direction of the Engineer-in-charge.
Providing, fitting and fixing of hermetically sealed compressor for replacement of defective one of fixed speed AC system as per direction of the Engineer-in-charge. (With one year warranty)
(I)1.5 TR capacity High wall split type AC.
(II) 2.0 TR capacity High wall split and cassette type AC.
(III) 2.5 TR capacity High wall split and cassette type AC.
(IV) 3.0 TR capacity High wall split and cassette type AC.
Providing, fitting and fixing of hermetically sealed compressor for inverter technology AC machine as per direction of the Engineer-in-charge. (With one year warranty)
(I) 1.5 TR capacity High wall split and cassette type AC
II) 2.0 TR capacity High wall split and cassette type AC.
(III)2.5 TR capacity High wall split and cassette type AC
(IV)3.0 TR capacity High wall split and cassette type AC
Providing, fitting and fixing of hermetically sealed copper condenser unit for replacing old one as per direction of the Engineer-in-charge.
(I) 1.5 TR capacity High wall split and window type AC.
(II) 2.0/2.5 TR capacity High wall split and cassette type AC.
(III) 3.0/4.0 TR capacity High wall split and vertical type AC.
Fitting, fixing of blower motor of AC systems after rewinding in/c necessary replacement of bush, shaft etc with complete varnishing as per direction of the Engineer-in-charge.
Providing, fitting and fixing of scroll motor (A.C)of indoor unit split type AC system as per direction of the Engineer-in-charge.
Providing, fitting and fixing of scroll motor (D.C) of indoor unit for inverter technology split type AC system as per direction of the Engineer-in-charge.
Providing, fitting and fixing of swing motor of indoor unit split type AC system as per direction of the Engineer-in-charge.
Providing, fitting and fixing of relay of split type AC system as per direction of the Engineer-in-charge.
Providing, fitting and fixing of air filter of split type and window type AC system as per direction of the Engineer-in-charge.
Providing, fitting and fixing of indoor PCB circuit for inverter technology split/cassete/Vertical type AC system as per direction of the Engineer-in-charge.
(I)1.0/1.2/1.5 TR split type high wall AC.
(II)2.0 TR split type high wall AC.
(III)2.5 TR/ 3.0 TR split/cassette type high wall AC.
Providing, fitting and fixing of outdoor PCB circuit for inverter technology split/cassete type AC system as per direction of the Engineer-in-charge.
(I)1.0/1.2/1.5 TR split type high wall AC.
(II)2.0 TR split type high wall AC.
(III)2.5 TR/ 3.0 TR split/cassette type high wall AC.
Providing and fitting fixing PCB circuit for fixed speed split/cassete type AC as per direction of the Engineer-in-charge.
(I)1.0/1.2/1.5 TR split type high wall AC.
(II)2.0 TR split type high wall AC.
(III)2.5 TR/ 3.0 TR split/cassette type high wall AC.
Providing, fitting and fixing of defective PCB transformer for split type AC system as per direction of the Engineer-in-charge.
Providing, fitting and fixing of defective pump motor for cassette type AC system as per direction of the Engineer-in-charge.
Supply and installation of additional length of copper pipe of for suction and liquid line with insulation and necessary wiring (with three pin electrical plug) to connect the indoor and outdoor unit as per direction of the Engineer-in-charge.
3/4th dia.
3/8th dia.
5/8th dia.
Fabrication of M.S platform for placement of condensing unit by using M.S angel of (50x50x5)mm/(65x65x5)mm size base plate, nuts & bolts/universal bracket (GSS) for ODU of split type AC system including all accessories for on-site installation i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-charge.
Dismantling and re-installation of 1.0/1.2/1.5/2.0/2.5/3.0/4.0 TR window, split and cassette type AC system as per direction of the Engineer-in-charge.
Providing, fitting and fixing of G.C.I shed of two parts slanting with ridge and necessary structure by using M/S angle of (30x30x5) mm size M.S flat (18x5) mm size over condensing unit i/c painting and finishing as per direction of the Engineer-in-charge.
Providing hard/ coil PVC pipe of good quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge
Providing, fitting and fixing of defective capicitor for window/split type AC system as per direction of the Engineer-in-charge.
i)25 mfd capacitor
ii) 36 mfd capacitor
ii)45 mfd capacitor
iii) 50 mfd capacitor
iv) (80-120) mfd capacitor
Providing, fitting and fixing of terminal clip as per direction of the Engineer-in-charge.
Providing fitting and fixing of PVC tape (Black tap) as per direction of the Engineer-in-charge.
Providing, fitting and fixing of thermostat for AC system as per direction of the Engineer-in-charge.
Providing, fitting and fixing of starting relay for window type AC system as per direction of the Engineer-in-charge.
Providing, charging of compressor oil with capillary complete
Supply and installation of additional length of electrical copper wire 4 mm size with casing size 01 (One) inch including other materials to connect outdoor unit with electrical panel as per direction of the Engineer-in-charge.
Providing, fitting and fixing of fan blade of outdoor unit of window, split, cassette and vertical type AC system as per direction of the Engineer-in-charge.
Providing, fitting and fixing of connector for split type AC system as per direction of the Engineer-in-charge.
Providing, fitting and fixing of remote with battery for window, split, cassette and vertical type AC system as per direction of the Engineer-in-charge.
Providing, fitting and fixing of coil sensor for split type AC system as per direction of the Engineer-in-charge.
Providing, fitting and fixing of room sensor for split type AC system as per direction of the Engineer-in-charge.
Providing, fitting and fixing of display sensor for split type AC system as per direction of the Engineer-in-charge.
Providing, fitting and fixing of nitral tape (Arrow tape) as per direction of the Engineer-in-charge.
Providing, fitting and fixing of contactors for split type AC system as per direction of the Engineer-in-charge.
Deployment of one(01) no. technician in one shift (08 hours) on each working day thoughout the year and other days of the year on as and when required basis to attend the call for maintenance immediately on urgent basis far carring out of work items under AMC.
Cleaning of Filters of Indoor units and Coils of Outdoor units of a AC system as per direction of the Engineer-in-charge.
ASHIRBAD REFRIGERATION (BID ID -167739)
R.P.ELECTRONICS (BID ID -167876)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_59481.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .