Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance KARNATAKA | RAICHUR | KARNATAKA | 584123 | Admitted-Finance |
| 3 | Admitted-Finance PLOT NO 70 01 JAGDA ROURKELA 769042 | SUNDARGARH | ODISHA | 769042 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹54,050
Closing Date
8 Jan 2024, 3:00 pmClosed
REGISTRAR NIT ROURKELA
NIT ROURKELA-769008
SITC of Power Distribution panels equipped with different rating MCCB as main incomer and outgoing feeders at various locations of academic area, NIT Rourkela
2023_NITRK_786088_1
NITR/EM/2023/M/0869/8978
Open Tender
Electrical Works
Works
365 days
Academic Area, NIT, Rourkela
As per tender documents
3 documents required · 3 mandatory
₹2,000
DIRECTOR NIT ROURKELA
₹54,050
Yes
Estate Management, NIT Rourkela
23 Jan 2024
19 Dec 2023
9 Jan 2024
19 Dec 2023
8 Jan 2024
19 Dec 2023
19 Dec 2023 - 26 Dec 2023
26 Dec 2023
Amount
Supply installation, testing and commissioning of double door outdoor type feeder Panels, fabricated out of heavy Gauge CRCA sheet steel in cubicle compartmentised modular construction complete with supporting rigid structure, interconnections, aluminium bus bar strip with heat strinkable colour coded current density of bus bar 0.8 A per sqmm. Degree of protection IP 65, earthing hinged doors with 2.5 sqmm tinned braded copper wire, plinth mounted type with removable Gland Plates bottom of the panel, all mounting plates shall be GI sheets. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. Galvanised hardwares with zinc passivation shall be used in fabrication of panels 2 Nos. earthing terminals shall be provided for all distribution panels. Panel drawing should be approved from Executive Engineer (Electrical) before manufacturing of the panels. Masonary works for panel plinth has to be completed before installation of the panel. Plinth cost is included in this rate. Panels shall be suitable for 415 V, 3 Phase, 4 Wire, 50Hz supply system along with the following acessories.
Incoming: 250 Amp, 36 KA, 4-pole MCCB with thermal magnetic protection unit having adjustable Overload & short circuit protection. --01 set
250 Amp 4-pole spreader link--01 set
Rotary handle for 250 amps 4-pole rating MCCB including connections etc as per requirement.-- 01 set
Out going: Vertical mounted Aluminium Busbar of size (50x10) sq mm including looping to incoming and outgoing feeders.-- LS
Slot for SITC of 4-pole MCCB 63 amps to 160 amps rating as out going feeder-- 08 nos
Slot for SITC rotary handle of 4-pole MCCB 63 amps to 160 amps rating as out going feeder-- 08 nos.
Instruments:Control MCB 6amp 10 KA, C-characteristics--03 nos.
Indication Lamp RYB LED type-- 03 nos.
Digital VAF meter including supply and fixing of compatible rating CT to be fixed with main incomer feeder.-- 01 set
Providing and fixing 63 to 100 Amp, 25 KA, 4-pole rating MCCB with thermal magnetic protection unit having adjustable Overload & short circuit protection in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
Providing and fixing 160 Amp, 36 KA, 4-pole rating MCCB with thermal magnetic protection unit having adjustable Overload & short circuit protection in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
Supply & fixing of rotary handle for 63 amps to 160 amps rating vary depth type MCCB including connections etc as per requirement.
Supply & fixing of spreader link for 63 amps to 160 amps 4-pole rating MCCB including connections etc as per requirement.
Dismantling of existing panel after disconnecting the cables from each feeder , shifting the old panel to estate office and arranging temporary power restoration to each feeder including connections etc. as per requirement.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 70 sq. mm (38mm)
3½ X 95 sq. mm (45mm)
3½ X 120 sq. mm (45mm)
3½ X 150 sq. mm (50mm)
4 X 25 sq. mm (28mm)
4 X 35 sq. mm (32mm)
4 X 50 sq. mm (35mm)
Dismantling of cable including excavation and removal of the power cable from trench as per requirement.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering (Red brick/tile block) and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Earthing with G.I. earth pipe 3.0 metre long, 50 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with Bentonite powder as required.
Supplying and laying 50 mm X 6 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
SHREE GOURI ELECTRIC ENTERPRISE
ECS ENGINEERING PRIVATE LIMITED
DEEPSIKHA ENTERPRISES
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .