Loading…
Loading…
Tender Value
₹12.4 L
EMD Value
₹12,400
Closing Date
6 Jul 2026, 6:00 pm5d left
Executive Engineer, Electrical (R&B) Division, Valsad
Providing 6 Passenger Lift at Taluka Court, Vansda, Ta. Vansda, Dist. Navsari.
317386
TENDER NOTICE NO. 04 OF 2026-27
Open
Electrical Works
Valsad
11 documents required · 11 mandatory
₹900
Executive Engineer, Electrical (Rand B) Division, Valsad
₹12,400
24 Jun 2026
24 Jun 2026
24 Jun 2026
6 Jul 2026
24 Jun 2026
Name of work : Providing 6 Passenger Lift at Taluka Court, Vansda, Ta. Vansda, Dist. Navsari.
Qnty. Unit Ite Item Description Rate in Rate in Words Per Amount
1 Ea. 1 Supplying, Erecting, Testing & Commissioning the 1235286.56 Rs. Twelve Lac Thirty Five Ea.
passenger lift having following main features: Thousand Two Hundred Eighty
Six and Paise Fifty Six Only
(A) GENERAL DESCRIPTION OF LIFTS.
[1] GEAR LESS LIFT DRIVE (MRL) comprising of
High Starting torque Lift 3 phase 440 V A. C. Permanent
Magnet Synchronous motor of proper rating with high
efficiency shall be used.[2] Micro processor based / PLC,
ACVVVF, vector control drive with encoder feedback
closed loop system shall be used for lift car and door
operation which shall be full collective selective
operation hall call demand response, UP/DOWN hall
stops, Main, Up/ Down Contactor with overload and
phase reversal relay and safety controls.
[3] Car with M S platform with bracings of adequate size
and to sustain the impact load cabin + passenger with
safety factor of fire for steel and side panels of Stainless
steel of sheet of grade 304 duty. Car ceiling will be S.S.
finishes with aesthetic appearance with LED ceiling
lights. Car flooring shall be of s/s 304 chaker plate
design sugeested of engineer in charge. of engineer in
charge. Car doors shall be of stainless steel grade
hairline finish with centre opening / telescopic automatic
doors. Car panel will also be S.S. 304 finished with
emergency stop device, mechanical door safety device,
facility of auto/ attended mode. All car panel buttons and
all floor switches must be with brail language as per lift
[4] All landing doors must be fire rated for 2 hour shall
be fully automatic centre opening/ telescopic opening
made of hairline finish steel grade of 304 with key holes
and infrared curtains with Unlocking facility from
[5] Appropriate battery operated emergency light in the
car along with alarm switch shall be provided. Also,
Emergency Light & Fan should start immediately
without any Time Delay as soon as power fails.
[6] Digital scrolling indicator system for up-down arrow
along with floor position indicator shall be provided
inside the car and at all floors.
[7] Full height infra red curtain with multiple cross /
crossing light beams shall be provided.
[8] Automatic Rescue Device (ARD) shall be provided
accordingly of passenger capacity with Manual Rescue
Operation ( Manual Cranking Facility).
[9] Audio visual indication in the lift car showing over
loading shall be provided such that doors kept open till
excess load is removed.
Qnty. Unit Ite Item Description Rate in Rate in Words Per Amount
[10] Spring buffers/PU Buffers shall be provided.
[11] Car fan as per passenger capacity with automatic
sleep timer shall be provided.
[12] Voice annunciator with suitable music shall be
provided in lift car.
[13] Self diagnostics system for operational and safety
parameters shall be provided in control panel.
[14] Mechanical over speed governor with governor
calibration as per actual site parameters and submission
of calibration certificate submission, door key holes in
the floor doors, fireman switch shall be provided.
[15] Lift machine hoisting arrangement in the lift
machine room and monkey ladder for lift pit should be
provided by the lift agency, along with the other steel
structure works, foundations for the machine etc…
[16] In the hoist way fascia plate shall be provided
without any extra cost, where ever required as / if
directed by engineer in charge.
[17] Permanent wiring with necessary safety devices like
RCCB in all circuit, Over Voltage Under Voltage
protection and THD eliminator in circuit for lift machine
room and lift well with proper numbers of light points,
with fixtures, exhaust fan and plug points shall be
provided by the agency. Only 3 phase Power Supply
shall be made available by department in lift machine
room. Necessary Earthing as per Lift Act/Rules shall be
arranged by Lift Agency.
[18] Any civil/ electrical works for additional and
alteration in lift shaft and machine room related to
erection of lift shall be made by lift agency without any
extra cost. (granite/marble fixing around all landing door
openings are not in lift agency’s scope.)
[19] Agency has to provide all working drawings and
documents and liaison services for obtaining all
necessary permission from lift inspector and other
authorities. [20] acrylic transparent licence/display
A4 size holder in lift car
[20A] As per statutory requirement of Govt. Of Gujarat
lift & escalator act 2000, lift agency has to provide
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor.
4.carrying out third party lift inspection during/after lift
erection and provide report by third party authorized by
concern licensing authority 5.agency has to provide
third party insurance upto completion of free
maintenance period and submit the document for the
[21] Car Panel Operating Buttons with floor position
indicator/buttons must be of Auto Glow type clearly
visible when view from inside cabin.
[22] For Physically Handicapped person Full Length
Handrails of hairline finish steel grade of 304 should be
provided at appropriate height on the Rear & Side Wall
Panels in Lift Car. [23] With Necessary KVA rating
voltage controlled Stabilizer suitable for your controller,
drive and all equipments of lift.
[24] Necessary rating of DP Elcb and FP Elcb required
for lift is in scope of work which rating is sugested by
CEICED Department (electrical Inspector)
Qnty. Unit Ite Item Description Rate in Rate in Words Per Amount
(B) SPECIAL FEATURES DESCRIPTION OF LIFTS
for PREMIUM category
1. Advanced control system dual 64 bit embedded
microprocessor with CANBUS Serial Communication
mode including Regenerative power efficient
operation,on site programming facility, Anti nuisance,
Pte-opening, BMS/RMS with necessary online real time
monitoring system having necessary connectivity for
remote monitoring & other suitable supporting hardware
& software devices to fulfil the purpose.
2. Floor Indication LCD Display with call registration &
brail mark with arrival gong and hall lantern & TFT
Screen in the car with MP3 Voice Announcer.
3. CAR Panel should be Scratch resistive SS Moonrock
finish / Hair Line / Honeycomb for car and all Doors,
All landing doors must have fire rating up to 2 hours and
car door must have multi-level crisscross beam door
4. To & fro communication system & wiring (i.e. car
control room & guard room ) and Each elevator are
equipped with remote monitoring system.agency has to
provide mobile app and user id and password for
6 Passengers, Ground plus 2 upper floors with Rated
Speed of 1.0 m/sec. (C) With General PLUS
ADDITIONAL SPECIAL FEATURES attached
herewith. Prem. Cat. (Make : Otis, Mitshubishi, TKE
previously Thyssenkrupp, Schindler, Johnson)
Rs. Twelve Lac Thirty Five Thousand Two Hundred
Eighty Six and Paise Fifty Six Only
Executive Engineer
Electrical (R & B) Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Schedule B.pdf
Pre – Qualification (Eligibility) Criteria of Bidders.pdf
Judge Letter.pdf
Notice No 04 of 2026-27 Lift.pdf
Annexure – I.pdf
Annexure – II.pdf
Annexure – III.pdf
Annexure – IV.pdf
4.0 FINAL _ SBD (Electrical Work) _ 2024 _ 120 pg (1).pdf
Download all tender documents and submit your bid