Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹69,600Qualified Make: MOTOROLA
Model: Motorola Battery Charger for GP 328/338 3 93 2NDFLOOR PCOM SOLUTIONS PVT LTD SECOND FLOOR LALITA PARK LAXMI NAGAR 110092 EAST DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Make: MOTOROLA
Model: Motorola Battery Charger for GP 328/338 | L1 | Qualified | |
| 2 | L2₹74,240+₹4,640 (6.67%)Qualified Make: MOTOROLA
Model: Motorola Battery Charger for GP 328/338 816 SECTOR 14 SECTOR 14 FARIDABAD FARIDABAD HARYANA 121004 | FARIDABAD | HARYANA | 121004 | Make: MOTOROLA
Model: Motorola Battery Charger for GP 328/338 | L2 | Qualified | |
| 3 | L3₹83,984+₹14,384 (20.7%)Qualified Make: MOTOROLA
Model: Motorola Battery Charger for GP 328/338 ANTRIKSH TECHNOSYS PVT LTD E 173 LGF KALKAJI NEW DELHI 110019 SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | Make: MOTOROLA
Model: Motorola Battery Charger for GP 328/338 | L3 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
17 Aug 2018, 11:00 amClosed
battery chargers Battery Chargers ( 58 ) Technical Specifications Specification Specification Name Values Allowed Values Ungrouped GENERIC Charger technology Transformer Based Transformer Based
SMPS Based Compatibility with battery type (User Selectable) VRLA-SMF Tubular
VRLA-SMF Number of Independent charging stations (in numbers) 1 1 CONSTRUCTIONAL Input Voltage Range (VAC) 160 volt 270 volt (ISI MARKED POWER CORD TO BE PROVIDED) - AC surge protection AC surge protection at Input side with MOV (Metal Oxide Varistor) - Soft start and Soft stop feature without inrush current Yes - Facility for charging deep discharged battery through pulse charging. yes - Not to charge battery in case one or more Yes - 1/4 cells are internally short/Battery voltage less than 10.5V Digital display of output voltage and current Yes - LED Indication for Charging Status
Charged condition status and reverse polarity Yes - Cabinet Material CRCA Sheet - Cabinet Thickness (mm) minimum 1.2 mm - Length of Charging Cable for each station. (metre) Minimum 1.5 mtrs. Length (ISI MARKED Cable) - Size of Charging Cable for each station. (sq. mm) min. 6 sq.mm as per IS:694 ISI MARKED FLEXIBLE Cu cable per station - FUNCTIONAL Battery/battery bank Voltage (Volts) 12 Volts per station - Capacity of the battery to be charged(User Selectable) (AH) 7 aH TO 120 aH - Maximum Charger output current (Amp) 12 Ampere per station - Charging Cut-off Voltage per 12V battery (Volts) 14.5 volt +/-0.2 volt - Efficiency (%) >/= 75% - Ripple (Peak to Peak at Full Load) (millivolts) <100 - Reverse Polarity Protection Yes - Short Circuit Protection Yes - Over Current Protection Yes - Over voltage cutoff protection Over voltage protection at 280 volt at input and automatic recovery at 270 volt when the voltage is reduced from 280 volt - Cut-in voltage for charging a discharged battery (Volts) Cut-in voltage shall be 10.5 Volt - Cut-off voltage for Cut-off voltage shall be - 2/4 charging a discharged battery (Volts) 14.5 V +/- 0.2 Volt Minimum operating temperature (Degree Celsius) -10 - Maximum operating temperature (Degree Celsius) +55 - CERTIFICATIONS Availability of Type Test Report from Central Government NABL/ILAC Accredited lab To prove conformity to the specification Yes - Type Test report No. ETDC (MH)/T&M/053 - Test report date 18/08/2014 - Name of Lab STQC - Address of Lab Mohali
Punjab - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Debasis Pal 784001
O/O The Inspector General
FTR HQRS SSB Tezpur
PO. Tezpur 58 21
439877
GEM/2018/B/62198
battery chargers
21 days
Assam; Sonitpur
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| battery chargers Battery Chargers ( 58 ) Technical Specifications Specification Specification Name Values Allowed Values Ungrouped GENERIC Charger technology Transformer Based Transformer Based | - | - | - |
| SMPS Based Compatibility with battery type (User Selectable) VRLA-SMF Tubular | - | - | - |
| VRLA-SMF Number of Independent charging stations (in numbers) 1 1 CONSTRUCTIONAL Input Voltage Range (VAC) 160 volt 270 volt (ISI MARKED POWER CORD TO BE PROVIDED) - AC surge protection AC surge protection at Input side with MOV (Metal Oxide Varistor) - Soft start and Soft stop feature without inrush current Yes - Facility for charging deep discharged battery through pulse charging. yes - Not to charge battery in case one or more Yes - 1/4 cells are internally short/Battery voltage less than 10.5V Digital display of output voltage and current Yes - LED Indication for Charging Status | - | - | - |
| Charged condition status and reverse polarity Yes - Cabinet Material CRCA Sheet - Cabinet Thickness (mm) minimum 1.2 mm - Length of Charging Cable for each station. (metre) Minimum 1.5 mtrs. Length (ISI MARKED Cable) - Size of Charging Cable for each station. (sq. mm) min. 6 sq.mm as per IS:694 ISI MARKED FLEXIBLE Cu cable per station - FUNCTIONAL Battery/battery bank Voltage (Volts) 12 Volts per station - Capacity of the battery to be charged(User Selectable) (AH) 7 aH TO 120 aH - Maximum Charger output current (Amp) 12 Ampere per station - Charging Cut-off Voltage per 12V battery (Volts) 14.5 volt +/-0.2 volt - Efficiency (%) >/= 75% - Ripple (Peak to Peak at Full Load) (millivolts) <100 - Reverse Polarity Protection Yes - Short Circuit Protection Yes - Over Current Protection Yes - Over voltage cutoff protection Over voltage protection at 280 volt at input and automatic recovery at 270 volt when the voltage is reduced from 280 volt - Cut-in voltage for charging a discharged battery (Volts) Cut-in voltage shall be 10.5 Volt - Cut-off voltage for Cut-off voltage shall be - 2/4 charging a discharged battery (Volts) 14.5 V +/- 0.2 Volt Minimum operating temperature (Degree Celsius) -10 - Maximum operating temperature (Degree Celsius) +55 - CERTIFICATIONS Availability of Type Test Report from Central Government NABL/ILAC Accredited lab To prove conformity to the specification Yes - Type Test report No. ETDC (MH)/T&M/053 - Test report date 18/08/2014 - Name of Lab STQC - Address of Lab Mohali | - | - | - |
| Punjab - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Debasis Pal 784001 | - | - | - |
| O/O The Inspector General | - | - | - |
| FTR HQRS SSB Tezpur | - | - | - |
| PO. Tezpur 58 21 | - | - | - |
Exempted
17 Aug 2018
7 Aug 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_439877.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .