| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC 19192 STREET NO 8 BIBI WALA ROAD OPPOSITE DAV COLLEGE BATHINDA PUNJAB PIN 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹1.8 Cr | L1 | Accepted-AOC Being L1 and found in order |
| 2 | L2₹1.8 Cr+₹1.1 L (0.58%)Rejected-AOC | ₹1.8 Cr+₹1.1 L (0.58%) | L2 | Rejected-AOC Not being L1 |
| 3 | L3₹1.8 Cr+₹2.2 L (1.21%)Rejected-AOC | ₹1.8 Cr+₹2.2 L (1.21%) | L3 | Rejected-AOC Not being L1 |
| 4 | L4₹1.9 Cr+₹7.1 L (3.86%)Rejected-AOC | ₹1.9 Cr+₹7.1 L (3.86%) | L4 | Rejected-AOC Not being L1 |
| 5 | L5₹2.2 Cr+₹33.0 L (18.1%)Rejected-AOC H NO 816 NEAR GANDHI CHOWK KALKA 133302 HARYANA | KALKA | PANCHKULA | HARYANA | 133302 | ₹2.2 Cr+₹33.0 L (18.1%) | L5 | Rejected-AOC Not being L1 |
| Sl No | Description | Qty | Unit | A P ENTERPRISES L2 | m/s jupiter builders L5 | M/S MANI GARG CONTRACTOR L1 | M/s Om parkash L3 | MILAP SINGH THAKUR L4 | M/S SEWA AND SERVE BUILDERS L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00SCHEDULE A PART-I (BUILDING WORK) | |||||||||
| 1.01 | Construction of Storage Accn (RCC Framed Structure) , with permanent specification including plinth protection and all as shown on drawings and as specified. | 1 | Each | 23,10,000 ₹23,10,000 Lowest | 39,55,000 ₹39,55,000 | 26,50,000 ₹26,50,000 | 33,00,000 ₹33,00,000 | 68,00,000 ₹68,00,000 | 1,20,50,000 ₹1,20,50,000 |
| 1.02 | Construction of Garrage Repair Bays (RCC Framed Structure) , with permanent specification including plinth protection, ramp and all as shown on drawings and as specified. | 1 | Each | 49,72,500 ₹49,72,500 | 57,85,560 ₹57,85,560 | 35,00,000 ₹35,00,000 | 42,00,000 ₹42,00,000 | 20,00,000 ₹20,00,000 Lowest | 49,50,000 ₹49,50,000 |
| 1.03 | Construction of Petrol Store (RCC Framed Structure) , with permanent specification including plinth protection, Platform, ramp and all as shown on drawings and as specified. | 1 | Each | 4,50,000 ₹4,50,000 Lowest | 5,99,650 ₹5,99,650 | 6,73,000 ₹6,73,000 | 8,00,000 ₹8,00,000 | 17,00,000 ₹17,00,000 | 25,50,000 ₹25,50,000 |
| 1.04 | Construction of Guard Rest Room (RCC Framed Structure) , with permanent specification including plinth protection and all as shown on drawings and as specified. | 1 | Each | 26,50,000 ₹26,50,000 | 28,58,650 ₹28,58,650 | 22,00,000 ₹22,00,000 | 26,00,000 ₹26,00,000 | 15,00,000 ₹15,00,000 Lowest | 42,50,000 ₹42,50,000 |
| 1.05 | Construction of Battery Charging Room (RCC Framed Structure) , with permanent specification including plinth protection, Verandah, ramp and all as shown on drawings and as specified. | 1 | Each | 9,66,280 ₹9,66,280 | 9,20,514 ₹9,20,514 | 10,00,000 ₹10,00,000 | 9,00,000 ₹9,00,000 Lowest | 10,00,000 ₹10,00,000 | 16,50,000 ₹16,50,000 |
| 1.06 | Construction of Washing Platform type 'B' of three bay in one platform with permanent specification all as shown on drawings and as specified. | 1 | Each | 15,50,000 ₹15,50,000 | 5,60,000 ₹5,60,000 | 25,00,000 ₹25,00,000 | 4,00,000 ₹4,00,000 Lowest | 10,00,000 ₹10,00,000 | 12,50,000 ₹12,50,000 |
| 2.00 | SCHEDULE A PART II-A (Internal Water Supply) for details refer Sch A in pdf folder | 1 | Each | 10,500 ₹10,500 | 8,614 ₹8,614 | 25,000 ₹25,000 | 12,000 ₹12,000 | 7,179.8 ₹7,179.8 Lowest | 24,500 ₹24,500 |
| 3.00SCHEDULE A PART II-B (Internal Water Supply) | |||||||||
| 3.01 | S&F health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 m long flexible tube and ABS wall hook including making connections and fixed in position complete all specified and directed. | 1 | Each | 1,495 ₹1,495 | 1,200 ₹1,200 Lowest | 1,500 ₹1,500 | 3,000 ₹3,000 | - | 1,500 ₹1,500 |
Tender Value
₹1.9 Cr
EMD Value
₹2.6 L
Closing Date
14 Aug 2025, 6:00 pmClosed
Brig T Lalit Mohan Chief Engineer Bareilly Zone
HQ Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly
PROVN OF ANCILLARIES STORAGE ACCN MT BTY CHARGING ROOM AND OTHER BUILDINGS AT KARCHAM
2025_MES_714930_1
CEBZ/DDN(H)/T-06 of 2025-26
Open Tender
Civil Works
Lump-sum
304 days
Jhakri
As per NIT
8 documents required · 8 mandatory
₹1,000
Yes
GE 863 EWS
₹2.6 L
Yes
6 Oct 2025
17 Jun 2025
21 Aug 2025
17 Jun 2025
14 Aug 2025
31 Jul 2025
17 Jun 2025 - 24 Jun 2025
Amount
SCHEDULE A PART-I (BUILDING WORK)
Construction of Storage Accn (RCC Framed Structure) , with permanent specification including plinth protection and all as shown on drawings and as specified.
Construction of Garrage Repair Bays (RCC Framed Structure) , with permanent specification including plinth protection, ramp and all as shown on drawings and as specified.
Construction of Petrol Store (RCC Framed Structure) , with permanent specification including plinth protection, Platform, ramp and all as shown on drawings and as specified.
Construction of Guard Rest Room (RCC Framed Structure) , with permanent specification including plinth protection and all as shown on drawings and as specified.
Construction of Battery Charging Room (RCC Framed Structure) , with permanent specification including plinth protection, Verandah, ramp and all as shown on drawings and as specified.
Construction of Washing Platform type 'B' of three bay in one platform with permanent specification all as shown on drawings and as specified.
SCHEDULE A PART II-A (Internal Water Supply) for details refer Sch A in pdf folder
SCHEDULE A PART II-B (Internal Water Supply)
S&F health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 m long flexible tube and ABS wall hook including making connections and fixed in position complete all specified and directed.
S&f 15 mm dia brass chromium plated central hole wash basin mixture fancy type with or without lettered hot or cold with long screwed shanks and fly nut capstan head screwed for 15 mm bore pipe complete all specified and directed.
S&F Brass Chromium Plated Angle Valve, fancy type screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed.
S&F for 32 mm dia low density polythylene pipe (LDPE) of pressure rating 6 Kg/sqmm complete all specified and directed.
SCHEDULE A PART III-A (Internal Electrification) for details refer Sch A in pdf folder
SCHEDULE A PART III-B (Internal Electrification)
M & L for point wiring using 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade, IS-694 single core multi-stranded (FRLS-H) copper conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.6 mm thick pressed modular steel terminal box for mounting fittings i.e, modular switch / sockets incl cover plate with frame including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded FRLS-H copper conductor cable as in earth wire and connecting all metal parts to common earth dolly incl cutting and chases pinning in for concealed conduit wiring and making good of disturbed surface complete all as specified and directed for the following: -
Note: (i) Blank (ii) All items used should be ISI marked. (iii) Cutting chases for concealed type point wiring including making good the same with plaster/putty is deemed to be included in quoted rate by the contractor. (iv) Accessories modular metal boxes, cover plate inner & outer is also deemed to be included in quoted rate.
(a) One light point point /bell buzzer/ ceiling fan/Exhaust fan point controlled by one-one way switch.
(b) One three pin 5 Amp socket on same board with other switches.
(c) One three pin 5 Amp socket on independent board
(d) All as per item No 5.01 above but point wiring with cable 2.50 Sq mm size, with earth continuity conductor of size 2.50 Sq mm.
Supply, installation, testing and commissioning of Water Heater Storage Type five star rating, electric suitable for single phase ,50HZ, AC supply, stainless steel inner assembly, 2 KW heating element, Twin thermostat for water temperature and safety thermostat stove enamel outer body including minimum 1M of three core 2.5 sq mm twisted copper conductor cable PVC sheathed, three pin plug top, polyethylene pipe connection piece 450mm long of 6Kg/sq,CM with two sets of chromium plated adopter at each end suitable for 15mm bore GI pipe at cold water inlet and copper tubing connection with chromium plated adopter at ends, at hot water outlet, with safety fusible plug confirming to relevant IS of 25 ltrs capacity.
M&L for flameproof point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS-H grade in and including medium duty concealed/ surface STEEL conduit 20 mm dia or higher and conduit fittings and all accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.2mm thick, duly painted for mounting of switches, sockets, fan regulator etc ,
including continuous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS-H grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of the following. (Note: Colour code shall be maintained as per IE rule)
(a) One light point point /bell buzze/ ceiling fan/Exhaust fan point controlled by one-one way switch.
(b) All as per item No-1 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity conductor of size 2.5 Sq mm.
S&F flameproof DB SPN, 240 volt with 200 amps rated copper bus bar for double door 4 way IP-66, IK-09 with one MCB SPN 20 Amps as incoming and 02 Nos MCB SP 06-10 Amps as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge .
SCHEDULE A PART IV (Site Clearance and Earthwork) for details refer pdf folder
SCHEDULE A PART V (Road, Path and Culvert) for details refer pdf folder
SCHEDULE A PART VI A (Sewage Disposal) for details refer pdf folder
SCHEDULE A PART VI B (Sewage Disposal)
M&L for PVC (SWR) pipes 110 mm single socketed in any length with rubberring joints fixed to walls.
SCHEDULE A PART VII (Area Drainage) for details refer pdf folder
SCHEDULE A PART VIII A (External Water Supply) for details refer pdf folder
SCHEDULE A PART VIII B (External Water Supply)
M&L for cutting of existing steel tubing of size 25 mm dia for alterations or additions, done in position without taking down, complete, all as specified and directed. Note: Each cut shall be measured. complete all as specified and directed.
SCHEDULE A PART IX A (EXTERNAL ELECTRIC SUPPLY) for details refer pdf folder
SCHEDULE A PART IX B (EXTERNAL ELECTRIC SUPPLY)
Supply & fabrication of outdoar type LT Panel board factory made CPRI approved with IP 54 grade of protection and installed at a height of 1 feet over suitable PCC plat form fabricated with suitable angle iron (50x50x6mm thick) bottom leg supports for resting independently cubical ,compartmental type with double hinged front openable doors, half turn type operating knobs for incoming feeders and out going feeders made of 2 mm thick CRCA sheet metal powder coated for outer sheet of panel and 3.1 mm thick CRCA sheet for patition and compartment doors
and with suitable capacity of aluminum bus bar not less than 160 Amps capacity for each phases supported by suitable insulators and covered with colour coded heat shrinkable sleeves along with wiring of panel with suitable size of copper conductor cable for accesories including provision of necessary cable entry/exit boxes complete all as directed by Engr-in-Charge. (A) Incomming (i) MCCB 100 Amp 25 KA 4P 415 Volts AC fixed thermal/magnetic setting, Nos-1 (ii) 3 phase Digital Volt meter, Nos-1 (ii) 3 phase digital ammeter ,Nos-1 (iv) 1 Phase Indicating lamp LED type of RYB colour for all three phases round in shape of 22.5mm,Nos-3 (B) Outgoing (ii) MCB TPN 40 Amps 16KA 4P 415 Volt AC,Nos-5
Supply and fixing of PVC Terminal /junction pole box, 4 pole strips, mounted on DMC insulator and MCB SP 6 Amps, 10 KA, Size 310 x 210 x 120mm and fixed with MS flat iron clamps to pole complete all as specified and as directed.
Supply and fixing of digital automatic street light control panel of 12 KW, made of extended wide band coil, FRLS (Fire retardant low smoke) Internal wiring, In-built Short-Circuit Protection, Provided with Protection Degree IP 54 and Class H Insulation, all as specified and directed by Engr-in-charge.
S & F sheet sheet metal enclosure with socket plug top, triple pole and neutral enclosure with two pin earth plug and socket completye with one MCB of capacity 20 to 32 Amps complete all as specified and as directed.
S&F bracket made of GI pipe light grade 40mm bore bend to shape in 120 degree of 1.2 m in length suitable for fixing street light luminaire and fixed on wall/pole including necessary MS clamps, nuts, bolts etc complete all as specified and as directed.
A P ENTERPRISES (BID ID -3384724)
M/s Om parkash (BID ID -3393810)
MILAP SINGH THAKUR (BID ID -3384493)
m/s jupiter builders (BID ID -3386048)
M/S SEWA AND SERVE BUILDERS (BID ID -3393410)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .