| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹30.6 L+₹1.9 L (6.56%)Rejected-Finance DOOR NO 50 13 27 14 FLAT NO 14 PADMAJA APARTMENTS SEETHAMMAPETA VISAKHAPATNAM 530016 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530016 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹31.0 L+₹2.3 L (8.01%)Rejected-Finance | L3 | Rejected-Finance Not lowest |
Tender Value
₹35.1 L
EMD Value
₹70,500
Closing Date
27 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer P Navy Kalinga Visakhapatnam
Garrison Engineer P Navy Kalinga Military Engineer Services INS Kalinga PO Visakhapatnam 531 163
ADDITION/ALTERATION TO WEAPON CLEANING/MAINTENANCE BAY (P-188) AT INS KARNA AND CERTAIN MISC REPAIRS TO KV SCHOOL AT INS KALINGA BHEEMUNIPATNAM
2022_MES_521137_2
GE (P)/N/K/8893 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Garrison Engineer P Navy Kalinga Visakhapatnam
₹70,500
Yes
12 Aug 2022
6 Jun 2022
29 Jun 2022
6 Jun 2022
27 Jun 2022
13 Jun 2022
Amount
Demolition of chajja drop/roof projection drop of thin RCC section of depth 10 to 20 cm, thick 8 to 10 cm and finishing the concrete surfaces with CM 1:3 complete all as specified and directed by Engineer In Charge.
Demolition of RCC as in roofs, floors, (other than ground floors), beams, staircases, landings, chajjas, drops, facias and similar suspended works(reinforcement cut as required to facilitate demolition),
Demolition of brickwork or stone boulder masonry built in cement mortar in portions
M&L PCC (1:2:4) Type B2 in foundation, filling and mass concrete
Use and waste of form work to sides of concrete foundations or similar works, vertical or to batter.
Taking down plastering on brick or stone wall,etc including raking out joints, hacking for key, scrubbing down with water etc all as specified and directed.
M&L for 10 mm thick rendering on Internal plaster of brick work or concrete surfaces in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L Preparation of new surfaces of wall and applying two coats of plastic emulsion paint over priming paint including applying 3mm thick wall care putty on walls.
Taking down chowkats or frames exc 1.50sqm but n.exc 4.00sqm (without taking off shutters from the frame)
Taking down aluminium frames exc 1.50sqm but n.exc 4.00sqm (without taking off shutters from the frame)
Second class hard wood Plain solid straight chowkhats and frames, wrought ,framed, rebated on the solid, rounded or chamfered ,put together with glue pinned at joints, supplied and fixed.
Second class hardwood 30mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats
Preparation of new wooden Surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of Synthetic Enamel Paint over a coat of pink primer
Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165
Preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described, and treated with tar or coal tar black paint treating ends of posts, backs of chowkats, etc, area tarred exc 0.1 sq.m but n exc 0.5 sq.m each ditto
Preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described, and treated with tar or coal tar black paint treating small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of chowkats, etc, area n exc 0.1 Sq.m each, ditto
125 mm Butt hinges, Medium weight, cold rolled mild steel, and fixed
Aluminium handles, cast type, anodised of size 150 mm
200mm Aluminium anodised, barrel tower bolts of extruded section and fixed
300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
Repairs of PVC Rain water Pipes of Dia 150mm single socketed in any length with rubber ring joints fixed to walls including necessary fittings complete all as specified.
150mm dia PVC (SWR) bends any radius complete all as specified and as directed by Engineer In Charge.
Post construction Anti Termite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors
Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15 mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre, including hangers 6mm dia. GI (Upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed by the Engineer-in-Charge.
MS Sheet 1mm thick in false ceiling concealed type fixed with screws in GI frame work catered under item No.24 above fixed with anchor fasteners complete all as specified and directed by the Engineer-in-Charge.
M&L for cleaning of all laitance, algae grease etc on existing concrete surface by grinding wire brushing or sand blasting and laying Non skid/matt finish coloured ceramic tiles to 8mm thick of size not exc 0.36 sqm in floor set and jointed in 'CERA BOND' or equivalent make tile adhesive and pointed in epoxy joint filler 'MYK LATICRETE' or equivalent make all as specified and as directed by engineer -in-charge.
cleaning of all laitance, algae grease etc on existing concrete surface by grinding wire brushing or sand blasting and laying Non skid/matt finish coloured ceramic tiles to 8mm thick of size not exc 0.36 sqm in in skirting/vertical and jointed in set and jointed in 'CERA BOND' or equivalent make tile adhesive and pointed in epoxy joint filler 'MYK LATICRETE' or equivalent make all as specified and as directed by engineer -in-charge.
Supply only Integral water proofing compound
Complete removal of existing treatment on wall and applying two coats of exterior emulsion paint over priming paint including applying 3mm thick exterior wall care putty on walls.
Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius with built in CM 1:6
Preparation of new plastered surfaces and applying two coats of oil bound distemper over wall care putty of 2mm thick over one coat of primer on walls complete all as specified and as directed by the Engineer-in-Charge.
Single stanchions, built up of one MS Tube conforming to IS-1161-1979 grade Yst 240 with flange plates,,caps,bases,splices angle brackets, cleats and other connections
Steel work in tubular trusses and column including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 and is painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication
Mild Steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment.
Mild steel screw bolts 11 to 15mm neck dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm n exc 10cm long.
Mild steel screw bolts 16 to 20mm neck dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm n exc 10cm long.
Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering for flat or arched roof cladding to wall, fixed with self tapping screws as specified
Preparation of new or previously untreated steel Surfaces of any description, over 10cm in width or girth, not otherwise described, priming with red oxide, zinc chrome and applying two coats of synthetic enamel paint
Hanger fastening screw bolts 10 to 12mm neck dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm n exc 10cm long.
Rendering 15mm thick plaster on concrete/brick masonry surfaces in CM(1:4) finished even and smooth w/o using extra cement complete all as specified
Preparation of new surface of walls and applying two coats of Exterior emulsion over a coat of primer for external surface on walls
Forming mortise holes exc 50 cu cm but not exc 100 cu cm for balusters, newels, posts etc and grouting with cement mortar (1;2) after fixing.
Anodised Powder coated(any tint) aluminium frame for doors, windows, ventilators, partitions with one or more rebates including necessary joining cleats ,glazing clips, rubber neoprene packing for fixing etc. complete all as specified (minimum thickness of powder coating 50 micron)
Sheet glass 5mm thick Tinted glass and glazing in aluminium frames ,in square exc 0.50 sqm in each pane, complete all as specified and as directed.
Frameless toughened glass door with sliding shutters(02 Nos) shutter 12MM thick ,factory toughened plain sheet glass , not exc 2.00SQM,using the stainless steel fittings of polished chrome finish ,in each shutter (satin stainless steel finish for handles) including cutting necessary holes and cutouts complete all as specified and as directed by Engr-in-charge. (a) corner lock patches with EPC and strike plateXL-C-4011A:01 No(for openable shutter) (b)Floor spring 90o open(EN4) 01 No(for openable shutter) (c ) Top patches XL-C 4012: 01 No (for openable shutter) (d) Bottom patches XL-C 4013: 01 No (for openable shutter) (e) Top pivots XL-C 4014: 01 No (for openable shutter) (f)450mm long H -Type handles 25mm dia of grade SS-304,XL-C-3003A: 01 No (01 Set for openable shutter)
Complete removal of existing treatment on wall and applying two coats of plastic emulsion paint over priming paint including applying 3mm thick wall care putty on walls.
Sheet glass 5.5 mm thick ,ordinary quality and glazing in aluminium frames ,in square exc 0.50 sqm in each pane, complete all as specified and as directed.
Door closer hydraulically regulated ,designation No:3,universal type, aluminium extruded section body, suitable for door shutters of 851 to 1000mm in width, complete all as specified and as directed.
20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over a screed bed of 20mm thick in cement mortar 1:4
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. Or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil
Plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
RCC 1:1.5:3 , Type A 20 mm graded stone aggregate in Foundations, including rafts, footings, plinth beam etc and mass concrete complete all as specified .
Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
Mild steel bars 6mm to 8 mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated soil exc. 250 m but n exc. 500 m and depositing where directed at a level n exc. 1.5 m above the starting point.
Cutting holes for bolts, pipes etc in stone walls built in cement mortar and walls of cement concrete area n exc 150 Sq cm and depth of 10cm
S&F Mild steel bolts ,purpose made, with hexagonal or square head,16 to 20mm neck dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 30cm long.
Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0
preparation of new steel or iron Surfaces of any description, n.exc10cm in width or girth, not otherwise described applying two coats of synthetic enamel paint over a coat of red oxide primer
UPVC window,(unplastisized poly-Vinyl Chloride) sliding windows multi-chambered and stiffened framed windows using 88mm x 52mm size sections all-round as main frames and shutters made with profile sections of size 57mm x 42mm, including the cost and fixing of 5mm thick clear float glass in shutters and stainless steel wire mesh shutters shall have well defined welded corner joints without any gaps, fixed the window unit to the existing masonry with anchor fasteners as required. The shutters shall have necessary handles and other associated fittings to facilitate smooth operation. Both the frames and the shutters shall be reinforced with GI profiles of thickness 1.25mm the entire window is covered with MS powder coated tube of size 40mm x 20mm all-round the frame the frame section, 10mm square bars horizontally placed at 120mm C/C and suitably placed vertically to avoid buckling and providing structural strength, Minimum weight shall be 10kg/Sqm and fixed to UPVC frames with suitable fasteners. The gaps between the window frames and masonry walls shall be filled with silicon or with any other suitable filler materials complete all as specified and directed. Make : Rajshri Plastiwood/Sintex/Duroplast Extrusion Pvt. Ltd
Dismantling Structural steel work including ladders, doors, gates etc.
Demolition of Reinforced cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Demolition of Unreinforced Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level
Demolition of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles portions ordered to be dismantled
Taking down Cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
Dismantling of water tank and removing to store of capacity exc 250 Lit but not exc 500Lit
Dismantling of water tank and removing to store of capacity exc 500 Lit but not exc 1000Lit
Dismantling of water tank and removing to store of capacity exc 1000 Lit but not exc 2000Lit
Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4
Preparation of new plastered surfaces and applying two coats of two coats of weather proof paint over a coat of primer.
2000 litres Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position
700 litres Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position
25mm Globe valve (PPR with steel ball) with iron wheel head, screwed both ends for iron pipe
Taking down PVC (SWR) Pipes (of any radius) including joints etc complete all as specified and as directed by Engineer-In-Charge
PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls
PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to walls
PVC shoe for rain water pipe of 110mm dia complete all as specified and as directed
Taking down existing roof treatment including plaster of any description
Brushing neat cement slurry with 3.0 Kg of cement per Sq.m
Plain Cement concrete 25mm thick (average thickness type B-0, 1:2:4 (12.50mm graded aggregate) in padding
10 mm thick screed bed over roof surfaces in CM 1:4 and finished even and smooth without using extra cement including mixing of W.P.C. (Note : WPC will be measured & paid separately)
APP based polymeric membrane minimum weighing 3 Kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric(weight not less than 150 gms/Sqm) land on primed surface by forced application complete all as specified and applying a coat of solar reflective bituminous aluminium paint.
75mm thick Plain Cement concrete of type C2, 1:3:6 of (20 mm aggregate) in Plinth protection finished even and smooth with extra cement complete all as specified and directed.
Removing loose and broken concrete by chiselling upto a depth of 80 to 100mm from columns, beams and similar structural memebers,cutting edges, cleaning the dismantled portion with wire brushes etc., and picking to remove dust, dirt and other foreign particles etc., and washing with clean water at desired pressure and removing debris to a distance not exceeding 50metre,
Removing loose and broken concrete by chiselling upto a depth of 20 to 40mm from floor/roof slab and similar structural members, cutting edges, cleaning the dismantled portion with wire brushes etc., and picking to remove dust, dirt and other foreign particles etc., and washing with clean water at desired pressure and removing debris to a distance not exceeding 50metre,
Applying one coat of anti-corrosive primer all as per manufacturers’ instructions to exposed reinforcement to the full circumference and length of bar in the area prepared vide Sl. Item No. 85 & 86 here-in-before, so as to form unbroken 40micron thick film using Nitozine primer of M/s FOSROC or techno-commercially equivalent in MC Bauchemic or S. Beck,
Non-shrink, cementious micro concrete mixed with 12.5mm graded stone aggregate using Renderoc RG of M/s FOSROC or techno-commercially equivalent, by weight (18 kg of aggregate : 25 kg of Renderoc RG) all as per manufacturers’ instructions, laid to an average thickness of 80mm to 100mm on surfaces of columns, beams and similar structural members prepared vide Sl. Item No. 87 here-in-before, with and including use and wastage of water tight form work, complete all as specified and directed.
Applying one coat of epoxy bonding agent of M/s FOSROC or techno-commercially equivalent, complete all as per manufacturers’ instructions, on old concrete surfaces prepared vide Sl. Item No. 87 here-in-before, with and including use and wastage of water tight form work to facilitate pouring of micro concrete,
Applying high build polymer modified mortar, 40mm thick, in two layers using Nitobond SBR of M/s FOSROC or techno-commercially equivalent, in the ratio of 1:1:3 (1 litre SBR + 1 litre Water + 3 kg of Cement) to ceiling surfaces, complete all as per manufacturers’ instructions,
Roughening surfaces of old concrete surface by picking, sweeping clean and washing down with water to remove dust, etc.
Cutting/Chipping the spalling concrete surfaces of columns beams, slabs etc and trimming & cleaning the surface to receive gunting applying epoxy treatment for bonding new or old concrete surfaces prior to guniting applying chemical FOSROC or Techno commercially equivalent and NITOBOND AR complete all as specified and as per manufacture instruction and providing pressure gunnting avg 25mm thick in CM (1:3) for slab/columns complete all as specified and directed including providing scaffolding as required and removal the same on completion of the work including scaffolding and welding the reinforcement to existing reinforcement and finished the surface fair and even (Reinforcement measured separately
Pressure grouting into RCC surfaces with cement slurry in the ratio 1:2 (cement and water) and mixing of cibex 100 or techno - commercially equivalent as per manufacturer instruction and mixing of NITOBOND AR of FOSROC or technochemically equivalent as per direction (NITOBOND AR of FOSROC or technochemically equivalent measured and paid separately including making hole in RCC surface for fixing PVC spout of required size to receive nozzle of pump and sealing the same after grouting etc
Supply only of NITOBOND AR of FOSROC or techno - chemically equivalent
Mild steel TMT bars 10mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
M&L for concealed point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLS PVC insulated and unsheathed 1100 V grade multi stranded copper conductor single core cable drawn through and including 20 mm dia (medium grade) rigid metallic stove enamelled concealed conduit with all fittings and accessories including one run of FRLS PVC insulated and unsheathed single core multi stranded copper conductor cable of size 1.5 Sqmm as earth continuity conductor to common earth
All as per Item no 97 here-in-before but for one fan /E Fan point controlled by 1 one way switch and regulator all as specified and as directed.
All as per Item no 97 above but for one 3 pin switch socket outlet, 5 Amp on independent board all as specified and as directed.
All as per Item no 97 here-in-before but for one switch socket outlet, 5 Amp on same board with other switches all as specified and as directed
All as per Item no 97 here-in-before but for one16 Amp 3 & 5 pin switch socket outlet, independent with 4.0 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 4.0 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed.
Material and labour for sub main wiring with two single core PVC insulated un-sheathed cable with multi-stranded copper conductor of 6.0 sq mm size and drawing into and including concealed PVC conduit of 25 mm dia with earthing cable of PVC insulated un-sheathed stranded copper conductor of size 6.0 sqmm, single core, as earth continuity wire all as specified and as directed. (NOTE: 3 runs of 6.0 Sqmm cable and one run of PVC concealed conduit 25mm dia will be measured as one unit i.e. RM)
Material and labour for sub main wiring with two single core PVC insulated un-sheathed cable with multi-stranded copper conductor of 6.0 sq mm size and drawing into and including concealed PVC conduit of 25 mm dia with earthing cable of PVC insulated un-sheathed stranded copper conductor of size 6.0 sqmm, single core, as earth continuity wire all as specified and as directed.
Supply and fixing switch piano flush button single pole one way 6 amps 250 Volt all as specified and as directed.
Supply and fixing switch piano flush button single pole one way 16 amps 250 Volts all as specified and as directed.
supply and fixing modular socket 6 Amp 5 pins .
M&L modular socket 6-16 Amps 2/ 3 pin combined shutter complete all as specified and as directed.
S&F modular step type fan regulator 120 watt two module five steps and back plate complete all as specified and as directed.
S&F modular plate white colour suitable for flush metal boxes for mounting modular switches or sockets etc for 8 modules complete all as specified and as directed.
All as per Srl Item No. 109 here-in-above but for 6 modules
All as per Srl Item No. 109 here-in-above but for 3 modules
All as per Srl Item No. 109 here-in-above but for 2 modules
S&F flush metal box 1/2 module complete all as specified and as directed.
All as per Srl Item No. 113 here-in-above but for 6 modules
All as per Srl Item No. 113 here-in-above but for 3 modules
All as per Srl Item No. 113 here-in-above but for 8 modules
Fixing only ceiling rose, surfaces bakelite three terminal complete all as specified and as directed.
Supply and fixing sheet metal enclosure for MCCB, DBs, phosphatised, Powder coated , Triple Pole and Neutral (TPN), suitable for 4 way, Double door 415 Volts , all as specified and as directed .
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 8 way with dim rail earth and neutral bar , all as specified and as directed.
Supply and fixing MCB Four Pole (FP) C curve 10kA breaking capacity of 63 amps, 415 Volts in proper position, all as specified and as directed.
Supply and fixing MCB Single Pole (SP) C curve 10kA breaking capacity of 6 to 32 amps, 240 Volts in proper position, all as specified and as directed.
Supply and fixing in proper position MCB double pole of capacity up to 40 amps, 240 Volts C-series with 10kA breaking capacity, all as specified and as directed.
S&F single pole and neutral enclosure with two pin earth plug and socket complete with 01 double pole MCB 20 Amps 240 volts complete all as specified and as directed.
LED building security light 35 W 220 v ,IP 65 suitable for at existing false ceiling /pole/wall/tower/ground with suitable size necessary fitting and fixture (hook/suspended rod of required size existing electric incoming cable incl taking down old unserviceable one.
supply and installed hi wall split AC units indoor/ out door complete with cordless remote control unit and with in built air ioniser, working on dual Rotor inverter Technology, precision cooling technology, having brushless DC motor, high cooling performance and plasma filter with climate control for better indoor air quality with minimum 5 star rating and ISEER 3.2 of capacity 1.5 ton.
Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 130 Volt to 500 Volts with out put voltage stabilizer to 230 volts with accuracy of +-2.5% Make v-Guard (VGB500)/ ANCHOR/Vertex The unit are quoted include the installation of voltage stabilizer and there should be warranty of 03 years on the stabilizer on whole.
Water heater storage type steel body with copper inner tank, and heating element upto 2KW capacity 25 Ltr BEE 5 Star rated complete with all accessories such as safety valve, thermostat NRV a connection pipe. Note. The unit rate includes the fixing arrangement of geyser through clamps and making holes for fixing the bolts and filling the surface with plaster and making good the disturbed surface, matching with colour of existing wall and plug top for the electrical connection of Geyser and tools for fixing .
Supply and fixing on wall security LED light luminaries fitting 1X22 W and including cable for connection from ceiling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable including 25 mm GI bracket medium grade 1m long bent to shape including bolt, nut, washer, clamp etc all as specified and as directed by the Engineer-in-charge.
Supply and fixing Ceiling fan of 1200 mm sweep BLDC 32 W decorative blades metallic white energy rating with clamp and hook at proper position with taking down old ceiling fan and kept in MES store yard with necessary accessories etc.
M&L for earthing complete with galvanized steel earth plate electrode 600x 600 x 3.15 mm buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to 20 x3 mm copper strip as earthing lead by means of iron or steel bolts, nuts, check nuts and washers, and connected to equipments . Note that quoted rates includes excavation and earth work, PCC, Pit, CI Cover, Funnel with water Piping, GI protection pipe for protection of earthing lead and main earthing lead upto 7.5 Mtrs protection pipe for protection of earthing lead and main earthing lead upto 7.5 mtr
4 pole MCCB 125 Amp, 50 Hz, 415 v with rupturing capacity 16 KA
Three phase mono block Pump set of 7.5 HP working on 440 V , 3000 RPM
Removal of Surplus excavated soil to a distance not exceeding 50 mtr away from site and depositing where directed at a level not exceeding 1.5 Mtr above ground level
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade cross sectional area 35 sqmm .
P SRINIVASA RAO
POTHINA SAMBAMURTHY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .