Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-Finance | L1 | Accepted-Finance LOWEST | |
| 2 | L2₹11.1 L+₹42,457 (3.97%)Rejected-Finance SHOP NO 13 MOHINI MARKET KISHORE BAGH MANDORE JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance HIGHEST | |
| 3 | L3₹11.5 L+₹84,922 (7.95%)Rejected-Finance PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance HIGHEST | |
| 4 | L4₹11.8 L+₹1.1 L (10.0%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L4 | Rejected-Finance HIGHEST | |
| 5 | L5₹12.2 L+₹1.5 L (14.4%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L5 | Rejected-Finance HIGHEST |
Tender Value
₹17 L
EMD Value
₹34,000
Closing Date
4 Mar 2021, 6:00 pmClosed
SHRI T C SHISHODIYA, DCWE (C)
MULTAN LINE ARMY AREA JODHPUR
Spl Repair For Conversion Of LT OH Feeder To Underground Cable Including Allied Works In Army Area Jodhpur
2021_MES_417417_1
CWE (A) JODH-131 OF 2020-21
Open Tender
Civil Works
Item Rate
150 days
GE(Army) Utility
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
Yes
GE(Army) Utility
₹34,000
Yes
12 Aug 2021
30 Jan 2021
5 Mar 2021
30 Jan 2021
4 Mar 2021
18 Feb 2021
Amount
Laying of cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured,electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of sizes:- 150 sq mm 3.5 core
All as per Srl Item No 01 above but 120 sq mm 3.5 core
All as per Srl Item No 01 above but 95 sq mm 3.5 core
All as per Srl Item No 01 above but 70 sq mm 3.5 core
All as per Srl Item No 01 above but 50 sq mm 3.5 core
All as per Srl Item No 01 above but 25 sq mm 4 core
All as per Srl Item No 01 above but 16 sq mm 4 core
All as per Srl Item No 01 above but 10 sq mm 2 core Note for Srl Item No 01 to 08 :- (i) LT XLPE cable will be issued by department free for fixing under schedule 'B'. (ii) Earth work, cable protection, sand shall be measured and paid separately.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, erection of poles, struts/stays, leveling of yard etc not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
M&L for sand cushioning to underground cable screened un-washed river sand including spreading, leveling and hand punning etc complete all as specified and as directed.
Supply and lay of un-reinforced precast concrete cable cover, class LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soil complete all as specified and as directed.
Removing excavated material soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
Supply and fix GI pipe , 'light grade' with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed of size :- (a) 80 mm bore
All as Srl Item No 14 above but 50 mm bore
All as Srl Item No 14 above but 40 mm bore
Dismantling of unserviceable ACSR conductor of any type and size from existing unserviceable poles at various location complete all as specified and as directed.
Dismantling of serviceable insulated ACSR conductor (Rabbit) from existing poles at various location and deposited to MES store yard complete all as specified and as directed.
Dismantling of cross arms (Clamp, nut bolts ),care fully from site complete all as specified and as directed.
Dismantling of insulators any type any size from existing poles complete all as specified and as directed.
Taking out serviceable LT cable of any type and size for re-use and relaying at site as directed . Note : Earth work, sand & PCC covers/stone slab shall be measured and paid separately.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm complete as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 32 x 6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical Plate No 3 of MES Sch. part I and testing on completion including necessary excavation and earthwork, expansive soil, adequate common salt, charcoal dust and funnel, PCC(1:3:6) type C-1 pit with precast RCC(1:1.5:3) type A-I cover, 40mm thick reinforced with 6 mm dia MS bars 3 Nos both ways with lifting hooks made out of 6mm dia MS bars, watering arrangement with funnel, wire mesh, with 20mm dia GI medium grade watering pipe earthing lead from earth plate to equipment earth point complete all as specified.
Supply, install, testing and commissioning of LT Panel board, outdoor type, gable roof, floor mounted, suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars of rating 300 amps duly insulated by insulation of RYB colour mounted on porcelain insulators. The panel shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40 x 40 x 6 mm duly embedded in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 hinges to panel doors and locking arrangement as desired complete all as directed by Engr-in-charge and comprising of the following:- [ At Location-B] (A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy CL-1.0 rating - 01 No L&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 36 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) MCCB 4 Pole 415 Volts 25 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -03 Nos (c) MCB SPN 230 Volts 32 Amp rating -02 Nos
Supply, install, testing and commissioning of LT Panel board, outdoor type, gable roof, floor mounted, suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars of rating 200 amps duly insulated by insulation of RYB colour mounted on porcelain insulators. The panel shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40 x 40 x 6 mm duly embedded in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 hinges to panel doors and locking arrangement as desired complete all as directed by Engr-in-charge and comprising of the following:- [AT Location-C] (A) IN COMING (a) MCCB 4 Pole 415 Volts 25 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy CL-1.0 rating - 01 No L&T/Siemens. (B) OUT GOING (a) MCB SPN 230 Volts 32 Amp rating -02 Nos
Supply, install, testing and commissioning of LT Panel board, outdoor type, gable roof, floor mounted, suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars of rating 400 amps duly insulated by insulation of RYB colour mounted on porcelain insulators. The panel shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40 x 40 x 6 mm duly embedded in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 hinges to panel doors and locking arrangement as desired complete all as directed by Engr-in-charge and comprising of the following:- [At Location-U] (A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 250 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy CL-1.0 rating - 01 No L&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) MCCB 4 Pole 415 Volts 25 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -02 Nos (c) MCB SPN 230 Volts 32 Amp rating -03 Nos
Supply, install, testing and commissioning of LT Panel board, outdoor type, gable roof, floor mounted, suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars of rating 400 amps duly insulated by insulation of RYB colour mounted on porcelain insulators. The panel shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40 x 40 x 6 mm duly embedded in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 hinges to panel doors and locking arrangement as desired complete all as directed by Engr-in-charge and comprising of the following:- [At Location-L] (A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 250 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy CL-1.0 rating - 01 No L&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) MCCB 4 Pole 415 Volts 25 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (c) MCB SPN 230 Volts 32 Amp rating -01 No (d) Timer box with 3 pole contactor, 40A - 01 Set
Supply, install, testing and commissioning of LT Panel board, outdoor type, gable roof, floor mounted, suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars of rating 300 amps duly insulated by insulation of RYB colour mounted on porcelain insulators. The panel shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40 x 40 x 6 mm duly embedded in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 hinges to panel doors and locking arrangement as desired complete all as directed by Engr-in-charge and comprising of the following:- [At Location-M] (A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy CL-1.0 rating - 01 No L&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 36 KA 160 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) MCCB 4 Pole 415 Volts 25 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -03 Nos
Supply, install, testing and commissioning of LT Panel board, outdoor type, gable roof, floor mounted, suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars of rating 300 amps duly insulated by insulation of RYB colour mounted on porcelain insulators. The panel shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40 x 40 x 6 mm duly embedded in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 hinges to panel doors and locking arrangement as desired complete all as directed by Engr-in-charge and comprising of the following:- [At Location-N] (A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 160 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy CL-1.0 rating - 01 No L&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 36 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) MCCB 4 Pole 415 Volts 25 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -03 Nos (c) MCB SPN 230 Volts 32 Amp rating -02 Nos
Supply, install, testing and commissioning of LT Panel board, outdoor type, gable roof, floor mounted, suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars of rating 200 amps duly insulated by insulation of RYB colour mounted on porcelain insulators. The panel shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40 x 40 x 6 mm duly embedded in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 hinges to panel doors and locking arrangement as desired complete all as directed by Engr-in-charge and comprising of the following:- [At Location-O] (A) IN COMING (a) MCCB 4 Pole 415 Volts 36 KA 100 Amp rating thermal magnetic release type(Icu=Ics=100%) -01 No (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. (c) Panel mounted multi function energy meter of accuracy CL-1.0 rating - 01 No L&T/Siemens. (B) OUT GOING (a) MCCB 4 Pole 415 Volts 25 KA 63 Amp rating thermal magnetic release type(Icu=Ics=100%) -03 Nos (b) MCB SPN 230 Volts 32 Amp rating -01 No
Sachiyay maa Electricals
Shree Karni Construction
Shri Electrical Enterprises
SANJOLI CONSTRUCTION COMPANY
Nvimal Engineers and Contractor
M/S JAGDAMBA ENTERPRISES
Inkhead Corporation
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .