Tender Value
₹3.5 Cr
EMD Value
₹1 L
Closing Date
8 Aug 2023, 3:00 pmClosed
Superintending Engineer
Superintending Engineer, PHC,TVM
Design and Construction of 10.00 LL capacity of OHSR at Kattachalkuzhi
2023_KWA_591299_1
107/2023-24/KWA/PHC/D2/TVM
Open Tender
Civil Works - Water Works
Item Rate
270 days
Kottukal
Pls refer NIT
7 documents required · 7 mandatory
₹9,759
₹1 L
Yes
19 Oct 2023
31 Jul 2023
9 Aug 2023
31 Jul 2023
8 Aug 2023
31 Jul 2023
31 Jul 2023 - 7 Aug 2023
Amount
Construction of 10.00L Capacity OHSR
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
OD111613/2022-2023:od286847/2021_2022 :Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 3 m, disposed earth to be levelled and neatly dressed.Ordinary rock
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
50.2.26.1:Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
OD111619/2022-2023:od286849/2021_2022 :Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work,using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishing and reinforcement, including admixtures,water proofing etc in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.All works upto Floor Five level (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.11.1:Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
OD111666/2022-2023:od286850/2021_2022 ::12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof., 10m to 13m height
OD111720/2022-2023:od286851/2021_2022 :12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof., 13m to 16m height
OD111731/2022-2023:od286852/2021_2022 :12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof., 16m to 19m height
OD111739/2022-2023:od299076/2021_2022 :12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof., 19 m to 22 m height
13.21:Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
OD111946/2022-2023:od286853/2021_2022 :100.41.33 Supplying and fixing 600 x 600 mm CI manhole cover with frame( medium duty) charges including all cost, labour charges etc complete.
OD111953/2022-2023:od286854/2021_2022 :Supply and fixing of 100 mm CI / DI Air vent pipe with charges including all cost,labour charges etc complete.
100.36.1:Filling water with 5000 litre tankers fited in lorry and conveying water from a distance of 5 km (average) to the reservoir site and pumping the water into the reservoir of height not less than 3 m using 5 HP diesel engine pump set , hire for tanker lorry, tools and other appliences and cost of water etc. complete.
13.71:Lettering with black Japan pint of approved brand and manufacture
14.72:Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done .
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
13.50.3:Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
100.15.5:Conveying and laying Double Flanged (Screwed / Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS: 8329, excluding cost of pipe and specials: 300mm diameter Ductile Iron Double Flanged pipes.
100.15.3:Conveying and laying Double Flanged (Screwed / Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS: 8329, excluding cost of pipe and specials: 200mm diameter Ductile Iron Double Flanged pipes.
100.15.8:Conveying and laying Double Flanged (Screwed / Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS: 8329, excluding cost of pipe and specials: 450mm diameter Ductile Iron Double Flanged pipes.
100.15.6:Conveying and laying Double Flanged (Screwed / Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS: 8329, excluding cost of pipe and specials: 350mm diameter Ductile Iron Double Flanged pipes.
18.30.5:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:200 mm diameter pipe
18.30.10:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:450 mm diameter pipe
18.30.7:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:300 mm diameter pipe
18.30.8:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:350 mm diameter pipe
100.31.1.1:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 80mm diameter, Class I.
100.32.4:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 80mm Double Acting Air Valve.
100.31.1.5:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 200mm diameter, Class I.
100.31.1.7:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 300mm diameter, Class I.
100.31.1.8:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 350mm diameter, Class I.
100.31.1.10:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 450mm diameter, Class I.
OD112251/2022-2023:od287482/2021_2022 :Providing and Fixing 300 mm CI mechanical flow meter with ISI Standards with all accessories-Supply and delivery of Woltman model with removal mechanism water meters confirming to<br>ISO 4064 part I, II,III class B or IS 779 and IS 2373 with life cycle test certificate from FCRI lab. The water meters shall have magnetic drivers or mechanical drivers<br>and shall be versatile for installation in any position . The meters shall be hydrodynamically,<br>hydrostatically balanced. The runner, runner chamber, pointers of the meter shall be as per<br>ISO 4064 class B specification. Dry dial excavated counter housing fully protected against<br>flooding ensuring easy reading in all climates.
OD112253/2022-2023:od287484/2021_2022 :Providing and Fixing 450 mm CI mechanical flow meter with ISI Standards with all accessories-Supply and delivery of Woltman model with removal mechanism water meters confirming to<br>ISO 4064 part I, II,III class B or IS 779 and IS 2373 with life cycle test certificate from FCRI lab. The water meters shall have magnetic drivers or mechanical drivers<br>and shall be versatile for installation in any position . The meters shall be hydrodynamically,<br>hydrostatically balanced. The runner, runner chamber, pointers of the meter shall be as per<br>ISO 4064 class B specification. Dry dial excavated counter housing fully protected against<br>flooding ensuring easy reading in all climates.
OD112254/2022-2023:od286858/2021_2022 :Providing standarded pipe earth station for lightening arrester with 40 mm dia 4.5m long class B.GI pipe confirminng IS (latest edition) including supply of all materials and providing masonary enclosure with cover plate having arrangement and watering pipe etc with charcol/coke and salt as required.
OD112255/2022-2023:od286859/2021_2022 :Supply and providing imported vertical air terminal with 12 needled Nickal coated spike receiver ,supporting rod of 1.2m long 25mm dia and stand including all accesories with possitive absorber(45 meter receiving capacity) rigidly fixed on RCC roof includinfg supply of all materials including bolts and nuts ,installation etc.cutting,welding grouting,waterproofing the roof around the base complete etc as required
OD112256/2022-2023:od286860/2021_2022 :Providing Water level indicator assemblying by using float, pully, nylon rope, plumb bob with indicator lamp, MS board (30cm width)with sufficient depth to show the zero water level and full water level, painting 10 cm divisions, lettering, including cost for clamps, drilling of RCC slabs etc., complete.
OD112257/2022-2023:od286861/2021_2022 :Supply and installation of lightning protection arrangements with laying of 20 mm x 3 mm Copper strip through eppoxy resign cast support,Down conductor through wall vertical run/through parapet ,supplying all materials including bolts and nuts ,installation etc.cutting,welding grouting,waterproofing the roof around the base complete etc as required
OD191083/2022-2023::Providing standarded pipe earth station for<br>lightening arrester with 40 mm dia 3.75m<br>long<br>class B.GI pipe confirminng IS (latest edition)<br>including supply of all materials and<br>providing<br>chamber and cover etc.comple
OD191095/2022-2023::Supply and installation of lightning protection<br>arrangements with 20 mm x 3 mm<br>Copper<br>tape and all materials including bolts and nuts<br>,installation<br>etc.cutting,welding<br>grouting,waterproofing the roof around the<br>base complete etc as require
OD191096/2022-2023:Supply and installation of lightning protection arrangements with 50 mm dia globe having<br>5<br>pointed probes at top 1 m long stem of 25 mm dia copper tube rigidly fixed on RCC roof including supply of<br>all<br>materials including bolts and nuts ,installation etc.cutting,welding grouting,waterproofing the roof around the<br>base<br>complete etc as required
OD112258/2022-2023:od286862/2021_2022 :Supply and installing test joint box fabricated out of 16 SWG CRCA sheet,supply and laying of 32x6mm GI strip through ground including earth work excavation,back filling and jointing complete
12.41.2:Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
13.50.4:Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)
Construction of Valve chamber , Anchor block & compound wall
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
50.6.5.2:Hollow block masonry using pre cast blocks ( Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part 1 of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Supply materials for OHSR .
OD112259/2022-2023:od286843/2021_2022 :Supply Ductile Iron Pipe Class K-9 flanges and welding 350 mm dia
OD112260/2022-2023:od286844/2021_2022 :Supply Ductile Iron Pipe Class K-9 flanges and welding 300 mm dia
OD112261/2022-2023:od286845/2021_2022 :Supply Ductile Iron Pipe Class K-9 flanges and welding 450 mm dia
OD112262/2022-2023:od286846/2021_2022 :Supply Ductile Iron Pipe Class K-9 flanges and welding 200 mm dia
OD112263/2022-2023:od286848/2021_2022 :DI specials like bend,tee,flanges....etc DSR 7684- Qtl weight 13700/
100.98.450:Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 80mm.
100.98.481:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 80mm.
100.98.485:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 200mm.
100.98.487:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 300mm.
100.98.488:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 350mm.
100.98.490:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 450mm.
Design charges
OD113161/2023-2024:Design Charges OHSR .-Design details (Design sheet)and submit the detailed drawings of all the components with hard and soft copy(3 Nos each ) and vetting from WASCON-KWA
Sreekumar S
Bidder Name
Jai Associates
Sreekumar S
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_875498.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .