Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹18.6 Cr
EMD Value
₹18.6 L
Closing Date
16 Nov 2026, 6:30 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Vice President, (P), GUDC Ltd., Gandhinagar
Barwala UGD-II under SJMMSVY : Working Survey, Soil Investigation, Design & Construction, Testing & Commissioning, Underground Drainage Project with 3.00 MLD Sewerage Treatment Plant Work Including Providing, Supplying, Lowering, Laying and Jointing Raising main and Gravity Main Pipeline Network, Providing House Connection, Property Connection, Road Restoration, Pumping Machinery, Pumping Station with Operation & Maintenance with All Allied Works for 02-[Two] Years and 07-[Seven] Years for STP Including 03-[Three] Years Defect Liability Period Including 03-[Three] Years Defect Liability Period for Barwala Nagarpalika Under Ground Drainage Phase-II Project, Taluka: - Barwala & District: - Botad, Gujarat” Under SJMMSVY
356096
GUDC/PROJECTS/SJMMSVY/UGD-II/Barwala
Open
Civil Works
Works
Gandhinagar
3 documents required · 3 mandatory
₹21,240
GUDC Ltd., Gandhinagar
₹18.6 L
17 Oct 2026
17 Oct 2026
17 Oct 2026
16 Nov 2026
17 Oct 2026
Schedule-B-1 Providing & Laying Gravity Sewerage Network
Schedule-B-2 Construction of Sewage Pumping Station (O-1)
Schedule-B-3 Construction of Sewage Pumping Station (O-2)
Schedule-B-4.1 Mech, Elec., Instrumentation Work for Pumping Station -01
Schedule-B-4.2 Mech, Elec., Instrumentation Work for Pumping Station -02
Schedule-B-5 Providing and Laying of Rising Main
Schedule-B-6 Construction of Inspection Chambers
Schedule-B-7 Construction of House Connections
Schedule-B-8 Construction of 3.0 MLD Sewage Treatment Plant at Barwala
Total of Schedule-B
Schedule-C-1 02-Years of Operation & Maintanance For Drainage Network System
Schedule-C-2 07-Years of Operation & Maintanance For Sewerage Treatment Plant
Total of Schedule-C
Total of Schedule-B + Schedule-C
Providing & Laying Gravity Sewerage Network
Item Description Qty Unit Rate Amount
1 Excavation for pipeline tenches for sewerage line, manhole with shoring & shruting if 71,546.70 Cum 102.35
required as per required gradient and line including all safety provision using site rails
and stacking excavated stuff including up to all required lead cleaning the site etc.
complete for all lift and strata as specified.
In all sorts of Soil and soft murrum.
Upto 1.50 mt depth
1.4 6.00 mt to 7.50 mt depth 184.00 Cum 129.95
1.5 Upto 1.50 mt depth 1,645.00 Cum 427.80
In hard rock and / or in C. C. 1:2:4 or RCC with blasting, breaking, chiseling, or by
chiseling/breaking only
2 Excavation in bituminous road as per reuired gradient and line including safety 6,578.40 Cum 288.65
provisions using site rails and stacking excavated stuff including up to all required lead
cleaning the site etc. complete for all lifts as specified.
Excavation in Bituminous Road
3 Providing bedding incl. ramming, watering, consolidating etc. as per standard and 1,393.00 Cum 378.35
instruction of engineer incharge. As above with required quality Sand brough from
outside including all lead.
4 Providing and casting in situ C.C. in grade M-20 (proportions as per mix design or as per 477.00 Cum 6,348.00
table9 of IS456 2000 in masses by weigh batching) using granite, quartzite trap metal of
size 6 mm to 20 mm for RCC work, including scaffolding centering, formwork, needle
vibrated consolidation, curing complete (excluding cost of reinforcement and neat
finishing) with centering and shuttering/ deshuttering etc. complete for structure other
than water retaining (Below G.L)
Footing for column or foundation (with form work)
5 Providing and supplying ISI Standard R.C.C. pipes (of Sulphate Resisting Cement) in 3,895.00 Rmt. 527.00
standard lengths of following class and diameter suitable for either collar joints or
rubber ring joints including all taxes, insurance, transportation, freight charges, octroi,
inspection charges, loading, unloading, conveyance to departmental stores, stacking
Note: One rubber ring should be supplied with each full length socketed pipe, cost
included in rates below. as Directed by Engineering in charge.
Class NP3 Test Pressure 0.7 Kg/sq.cm
Class IRS/NP-4 3,871.00 Rmt. 757.00
Lowering, laying & jointing R.C.C pipes in C.M. 1:1.5 for following dia in proper position 7,766.00 Rmt. 111.55
, grade and alignment as directed by Engineer -in-charge including conveyance from
6 store to site of work. Labour giving Hydraulic testing as per ISI code.
Item Description Qty Unit Rate Amount
7 Providing, fixing and constructing of pre-cast RCC M-40 grade circular manholes with 333.00 No. 17,800.00
internal dia 1.2m and up to specified depth having pre-cast RCC M-40 grade circular
manhole cover frame (ID 0.56m, OD 0.92m), conical piece (top ID 0.56m, bottom ID
1.2m, vertical height 1.005m, wall thickness 125mm), and circular rings of required
heights (ID 1.2m, height 150/225/300/600/900mm, wall thickness 125mm) below
conical piece as per required depth of manhole and having steel reinforcement in
Conical piece @ not less than 80 kg per cum of concrete, including cast-in-situ PCC M-
10 grade (1:3:6) foundation of 1.825m dia and 150mm thickness, PCC M15 grade
circular wall ID 1.125m, wall thickness 200mm, height equal to ID of sewer pipe + one
wall thickness of pipe + 50 mm (to flush the manhole frame with road top, height of
wall can be increased but not more than 100mm), PCC M15 grade benching and
channel portion and up to top level of sewer pipe etc complete with curing compaction
and form work, supplying and fixing heavy duty SFRC manhole cover as per IS
(Part I and II), supplying and fixing plastic encapsulated CI/MS footsteps / SFRC
footsteps, including cost of shuttering, steel reinforcement, testing for water tightness
etc complete in all respect as per drawing, as per specification and the direction of the
Engineer. Note:- Excavation of earth work and road cutting for manhole will be
measured and paid separately.
Pre-cast RCC M-40 grade circular manhole conical piece with inbuilt cover and frame
(height 1.005), cast-in-situ PCC M-10 grade foundation, PCC M15 grade circular wall ID
1.125m, wall thickness 200mm, wall height equal to ID of sewer pipe + one wall
thickness of pipe + 50 mm, PCC M15 grade benching and channel portion. Depth of
manhole shall be measured from top of manhole cover upto lowest invert of pipe.
(Depth includes in the item = height of Conical piece + ID of Sewer pipe + 1 Wall
thickness of pipe + increased height of wall (if any) + 50mm)
Providing and fixing pre-cast RCC M-40 grade circular ring of ID 1.2m, wall thickness 164.00 Rmt. 7,810.00
7.1 125mm, height 150/225/300/600/900mm for constructing extra depth of manhole
beyond depth mentioned in above item as per drawing.
Providing and constructing Sewer manholes, scraper manholes and unit house 9.00 No. 14,005.85
connection chamber, as per the type design in brick masonry in C. M. 1:5 and inside
and outside 20mm thick plastering in C. M. 1:3 necessary 100 mm coping with
reinforcement in R.C.C.M. 200 fixing C. I. steps and fixing manhole frame and covers
(But excluding supply of manhole frame and covers) over manholes and house
connection chambers and fixing Manhole covers (but excluding supplying of manhole
covers) over scraper manhole etc. complete, providing and fixing safety chain wherever
necessary as per the stipulations in the type design complete as per latest CPHEEO
manual.(excl. excavation).
Manhole type "A" circular type having inside diameter of 1200 mm for depth upto
m depth. (For 150 mm to 500 mm dia sewer).
Manhole type "A" as above but upto 1.0 m depth.
Extra depth beyond 1.0 m. but upto 1.5 mt. depth for "A" type manhole above. 5.00 Rmt. 7,622.20
Manhole type "B" circular type having inside diameter of 1500 mm and for depth from 128.00 No. 24,283.40
8.2 1.5 m to 4.0 mt. (For 150 mm to 600 mm dia sewer)
Manhole type "B" as above but upto 1.5 m depth
8.3 Extra depth beyond 1.5 m but upto 4.0 mt. depth for type "B" manhole above. 96.00 Rmt. 14,159.95
9 RCC Precast M.H. Frame & Cover Manufacture, Supply & Delivery at store or at site of 137.00 No. 1,121.00
work precast RCC M.200 Frame & Cover suitable to drainage M.H. and as per type
design & Drawing including cost of reinforcement M.S. Angles or Flat, curing moid work
Frame Suitable for 50cm Opening of MH
9.1 Cover Suitable for 50cm Opening of MH 137.00 No. 1,173.00
10 Refilling the pipeline trenches including ramming, watering, consolidating disposal of 1,54,033.00 cum 25.30
surplus stuff as directed within a radius of 3 Km.
Item Description Qty Unit Rate Amount
11 Making connection to the ex. M.H. in running sewer incl. Dewatering and other 4.00 No. 1,500.00
required machinery etc. of following dia pipes at any convenient time. All damaged
work shall be well repaired as per instructions.etc. complete.
12 Providing, laying, spreading and compacting graded stone aggregate to wet mix 5,482.00 cum 1,126.95
macadam specification including premixing the Material with water at OMC in
mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform
layers in subbase/base course on well prepared surface and compacting with vibratory
roller to achieve the desired density as per MoRTH clause
13 Construction of 200 mm thick un-reinforced, dowel jointed, plain cement concrete 5,485.00 Sq.m 1,591.00
pavement with M - 35 grade of concrete including provision of contraction, expansion,
construction and longitudinal joints, joint filler,sealant primer, joint sealant, , dowel bar,
tie rod, admixtures as approved, finishing to lines and grades as per drawing as per
MoRTH clause 602 over a 200 mm thick WMM with necessary excavation/ loosening
and recompacting ground as per respective MoRTH specification and as directed by
engineerin charge
14 Providing & erecting C.I & M.S ventilating column 15 cms dia with CI ornamental cap 15.00 No. 38,911.40
and min 6 mt height (height may be varying as per site) base fixed firmly with necessary
foundation with one coat of red oxide paint and one coat of any approved colour with
15 cms dia 10 mt in length with 0.35 m x 0.35 m x M100 encasing, RCC pipe connection
with M.H including excavation and jointing as required etc complete as per drawing.
For 6 Mt height ( 6 Mt MS pipe)
14.1 For 12 Mt height (2 m CI and 10m MS) 14.00 No. 47,414.50
15 Dewatering by pumping set of required capacity including temporary platform carting 4,747.00 HP/hr 21.07
pumping at site and fixing the same in position including all accessories, and fuel and
labour etc. complete.
Pump set of capacity
16 Scrapper manhole type S1 rectangulartypefor 600 mm dia to 1200 mmdia sewer pipes 60,166.85
and for depth 2.5 m to 9.0 m. 13.00 No
Scraper manhole type S1 as above but upto 2.5 m depth
16.1 Extra depth beyond 2.5 m and upto 9.0m depth for type S1 Scrapper manhole as above 36,693.05
Construction of Sewage Pumping Station (O-1)
Item Description Qty. Unit Rate Amount
Excavation for well/pumping station including removing and spreading 360.00 Cum 147.20
the excavated stuffs directed with all lead.
loose or soft Soil
From 0.0 to 1.5 m. Depth
1.1 From 1.5 to 3.0 m. Depth 159.00 Cum 162.15
1.2 From 3 to 4.5 m. Depth 106.00 Cum 178.25
1.3 From 4.5 to 6.0 m. Depth 46.00 Cum 197.80
Excavation for well/pumping station including removing and spreading 159.00 Cum 328.90
the excavated stuffs directed with all lead
From 1.5 to 3.0 m. Depth
1.5 From 3 to 4.5 m. Depth 247.00 Cum 345.00
1.6 From 4.5 to 6.0 m. Depth 107.00 Cum 364.55
1.7 From 6 to 7.5 m. Depth 109.00 Cum 386.40
1.8 From 7.5 to 9.0 m. Depth 69.00 Cum 411.70
2 Refilling with available excavated earth including ramming, watering, 749.00 Cum 25.30
consolidating disposal of surplus stuff as directed within a radium of
Km. Refilling as directed
3 Filling in plinth with sand under floors including water ramming, 20.00 Cum 481.80
consolidating and dressing complete.
Extra for dewatering for excavation in wet condition and in all strata
From 3 to 4.5 m.
5 Providing and casting in situ C.C. in grade M-15 (approx. corresp. to 51.00 Cum 5641.90
prop. 1:2:4) (proportions as per mix design or as per Table 9 of IS456
2000 in masses by weigh batching ) using granite, quartzite trap metal
of size 6 mm to 20 mm for RCC work, including scaffolding centering,
form work, needle vibrated consolidation, curing comp. up to
meter depth or height (excluding cost of reinforcement and neat
finishing) with centering and shuttering/deshuttering etc. comp. for
structure for other than water retaining.
Footing for column or foundation (with form work)
6 Providing and casting in situ C.C. in grade M-15 (approx. corresp. to 70.00 Cum 5441.80
prop. 1:2:4) (proportions as per mix design or as per Table 9 of IS456
2000 in masses by weigh batching ) using granite, quartzite trap metal
of size 6 mm to 20 mm for RCC work, including scaffolding centering,
form work, needle vibrated consolidation, curing comp. up to
meter depth or height (excluding cost of reinforcement and neat
finishing) with centering and shuttering/deshuttering etc. comp. for
structure for other than water retaining.
Footing (Without form work)
Item Description Qty. Unit Rate Amount
Providing and cast in situ C.C. in grade M-30 proportions of ingredients
as per mix design by weigh batching using granite, quartzite trap metal
of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding
centering formwork, needle vibrated consolidation, curing and
hydraulic testing etc. complete (excluding cost of reinforcement) with
centering and shuttering/deshuttering etc. camp. up to 6 meter height
/depth Av. G.L.for all water retaining structures.
Flat bottom slab/floor slab/slab with shuttering
R.C.C. slab and footings
7.1 R.C.C. walls (Above 25 cm) 200.00 Cum 9295.45
7.2 Beams/ ring beams/girders ('R.C.C Beams ) 14.00 Cum 9758.90
7.3 Slab & Platform (Flat bottom slab/floor slab/slab with shuttering)
7.4 RCC Column 4.00 Cum 10714.55
7.5 R.C.C. Pedestal (Flat bottom slab/floor slab/slab with shuttering)
8 Providing and cast in situ C.C. in grade M-25 proportions of ingredients 10.00 Cum 9599.05
as per mix design by weigh batching using granite, quartzite trap metal
of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding
centering formwork, needle vibrated consolidation, curing and
hydraulic testing etc. complete (excluding cost of reinforcement) with
centering and shuttering/deshuttering etc. camp. up to 6 meter height
/depth Av. G.L.for all water retaining structures.
R.C.C. beams, lintels and bracket for gantry or chain pully blocks, plinth
beams, tie beams.
R.C.C. slabs and platform (Flat bottom slab/floor slab/slab with 4.00 Cum 9288.55
8.1 shuttering)
R.C.C. weather shed, pardi & staircase (Flat bottom slab/floor slab/slab 1.00 Cum 9288.55
8.2 with shuttering)
8.3 R.C.C. columns 5.00 Cum 10574.25
9 Providing and casting in situ C.C. in grade M-20 (proportions as per mix 5.00 Cum 6348.00
design or as per table9 of IS456 2000 in masses by weigh batching )
using granite, quartzite trap metal of size 6 mm to 20 mm for RCC
work, including scaffolding centering, formwork, needle vibrated
consolidation, curing complete (excluding cost of reinforcement and
neat finishing) with centering and shuttering/deshuttering etc.
complete for structure other than water retaining (Below G.L)
Footing for column or foundation (with form work)
10 Supplying cutting, bending, binding and placing in position steel as per 51.00 MT 89129.60
plan and design and as per ISS 2502 including cost of steel and binding
wire for reservoirs/structures only including lift below G.L. for all
Do - deformed (TMT) bars confirming to relevant IS Fe -
grade for all diameters.
11 Providing and fixing water tight construction or expansion joints 150 310.00 Rmt 379.50
mm. dia. Wide thin ribbed PVC.
Item Description Qty. Unit Rate Amount
12 Half brick masonry in common brunt clay building bricks having 5.00 Sq.Mt 629.84
crushing strength not less than 35 Kg/Sq.Cm. In Cement mortar 1:4 (1-
Cement : 4 -coarse sand ) in foundation and plinth (B) Conventional.
Extra for half brick masonry in superstructure above plinth level upto
floor two level. (B) Conventional
12.1 Extra for half brick masonry in superstructure above plinth level upto 5.00 Sq.Mt 54.43
floor two level. (B) Conventional
13 Brick work using common burnt clay building bricks having crushing 43.00 Cum 4214.33
strength not less than 35 kg./Sq.Cm. in foundation and plinth in
Cement Mortar 1:6 (1- Cement : 6 -fine sand) (B) Conventional
14 Extra for brick work in superstructure above plinth level upto floor two 23.00 Cum 281.72
level (B) Conventional
15 Providing and applying 20 mm thick inside OPC cement plaster with 270.00 Sq.Mt 303.00
water proofing agent on inside of sump consisting of 12 mm thick
backing coat of CM 1:3 (1 cement : 3 sand) and 8 mm thick finishing
coat of CM 1:1 (1 cement : 1 sand) etc. complete including necessary
curing, scaffolding required if any etc. complete.
16 Providing and applying 20 mm thick sand faced cement plaster at 258.00 Sq.Mt 342.41
outside RCC / brick on work upto height 10 mtr. above ground level
consisting of 12 mm thick backing coat of C. M. 1:3 (1 cement : 3 sand)
and 8 mm thick finishing coat of C. M. 1:1 (1 cement : 1 sand) etc.
17 Providing and applying 10 mm thick cement plaster in single coat on 22.00 Sq.Mt 145.65
concrete work for interior plastering upto floor two level finished even
and smooth in Cement mortar 1 : 3 (1 cement : 3 sand) in a single coat
over RCC slab (on ceiling) etc. complete as directed (In ceiling of pump
18 Providing 15mm thick cement plaster in single coat on Rough 93.00 Sq.Mt 246.05
(Similar)side of single or half brick walls for interior plastering upto
floor two level and finished even and smooth in (i) Cement mortar 1:3
(1-cement:3-sand) for finishing with a floating coat of
neat cement slurry.
19 Providing and laying 40 mm thick cement concrete flooring in 1:2:4 (1 74.00 Sq.Mt 305.58
cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal
size) including water proofing compound finishing with a floating of
neat cement etc. complete laid in one layer finished including
necessary curing with sulphate resistant cement.
Item Description Qty. Unit Rate Amount
20 Providing and laying 40 mm thick heavy duty cement concrete flooring 1.00 Sq.Mt 373.75
in 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) with ironite powder including finishing with a floating of
neat cement etc. complete.
21 Providing and laying polished Kota stone slab 25 mm thick in riser of 17.00 Sq.Mt 1109.07
steps, dado & pillars, skirting, laid on 10 mm thick cement mortar 1:3
(1 cement : 3 coarse sand) and jointed with grey cement slurry
including rubbing and polishing etc. complete
22 Distempering in 3 coats with oil bound distemper of approved brand 115.00 Sq.Mt 106.92
and manufacture and of required shade on wall surface to give an
even shade over and including a primer coat with distemper primer of
approved brand, thoroughly brushing the surface free from mortar
dropping and other foreign material and also inclusive of preparing the
surface even and smooth etc. complete,
23 Providing and applying epoxy paint of approved make to concrete 270.00 Sq.Mt 103.50
surface for RCC structure including cleaning the surface by scrapping
and air blowers to the satisfaction of Engineer-in -charge necessary
scaffolding etc. complete with all leads and lifts and giving satisfactory
hydraulic test for water tightness as per IS codes. For new surface-
24 Wall painting (two coats) with plastic emulsion paint of approved 258.00 Sq.Mt 94.33
brand and manufacture of undercoated wall surface to give an even
shade including thoroughly brushing the surface free from mortar
dropings and other foreign matter and sand papered smooth.
25 Providing and fixing window having extruded aluminum Colour 6.00 Sq.Mt 1583.95
anodized section frame main outer size 95mm x 24mm x 1.17 mm (of
Jindal Section no : 2459 @ wt. of 0.738 Kg/mt), horizontal Three track
member size 92mm x 31.75 mm x 1.30 mm (of Jindal Section no.
@ Wt. 1.07 Kg/mt), vertical member of size 92mm x 31.75mm x
mm (of Jindal Section no. 8933, @ Wt. 1.06 Kg/mt.) with sliding
shutters of horizontal member size 40mm x 18mm x .29 mm (of Jindal
section no. 8947 @ wt. 0.456 Kg/mt.) vertical member of size 40mm x
18mm x 1.29mm (of Jindal Section no. 8949 @ wt. of 0.456 Kg/mt with
5 mm thick transparent bronze colour tinted float glass with powder
coated aluminum fittings and fixtures and transparent silicon sealant
glass fixing to frame as per details etc.
26 Providing and fixing 50 cm wide M.S. Ladder fabricated from M.S. Flats 5.00 Rmt 3392.50
10 mm x 75 mm with 20 mm dia steel bar steps in double rows, @
em C/C. The include stays of 10 mm x 50 mm flats fixed at 3 meter
C/C wtih welding anchoring and 3 coats anticorrosive paint. (M.S.
ladder (without safty cage))
Item Description Qty. Unit Rate Amount
27 Providing & fixing in position aluminum fully paneled doors with 15 3.00 Sq.Mt 3054.24
micron natural matt brush finish anodized as per over all size shown
on the drawings and aluminum sections of approved make
conforming to IS:733 and IS : 1285, made out of 102 mm x 45 mm x
1.90 mm thick aluminum outer frame section weighing 1.640Kg/m.
and shutter sections with bottom / lock rail 96 mm x 45 mm x 2.7 mm,
top rail 48 mm x 45 mm x 2.70 mm weighing 1.38 Kg/m. vertical styles
48 mm x 45 mm x 1.90 mm weighing 0.976 Kg/m. with rounded sides,
fixed with roll plugs and screws or with fixing clips, or with expansion
hold esters including necessary filling up of gaps at junctions, at top,
bottom and sides with required PVC/neoprene felt etc. and aluminum
snap beading for glazing / paneling, C. P. brass/stainless steel screws,
including standard anodized aluminum fittings and fixtures of
approved make and of adequate size and in adequate numbers,
double action floor springs of approved make for each shutter with
standard pivot panels of 12 mm thick pre-laminated three layer
medium density, exterior grade particle board (termite proof, water
proof and fire proof)Grade 1, Type II conforming to IS : 12823 bounded
with phenol formaldehyde synthetic resin, of approved make including
cost and fixing of fixtures etc. complete as per detailed drawings with
all lead and lifts.
28 Providing and fixing 40mm dia. GI pipe medium weight quality as 22.00 Rmt 1784.00
openable type with angle iron support at 1.5 m c/c using 75 x 75 x
mm angles, 1 m long with three rows of pipes as railing including
necessary painting with two coats of approved quality oil paint over
one coat of approved primer including necessary welding, bolting
required, if any.
29 Supplying, cleaning, cutting, bending, welding, 'fabricating, erecting 1770.00 Kg 99.00
structural steel in position irrespective of locations and levels as per
drawing including handling and transport etc. complete including
applying two coats of primer red oxide and two coats of approved
quality of paint over it etc. complete as directed for gentry girder,
platform, stairs, chequered plate for cable trench etc.
30 Providing and fixing MS grating with 8 mm thick 50 mm wide flat at 50 5.00 Sq.Mt 12590.00
mm c/c to form grid pattern as specified and wherever directed
including two coats of approved quality oil paint with one coat of
primer red oxide etc. complete.
31 Providing and fixing plastic moulded reinforced steps with 10 mm TOR 40.00 No. 87.00
steel bar with plastic polyproclene (P.P.) material (vergin) etc.
32 Providing and fixing to wall, ceiling and floor 10.0 kg.F/cm2 working 10.00 Rmt 252.22
pressure polythene pipes of the following outside Dia. Low density
complete with special flange compression type fittings, wall clips etc.
including making good the wall ceiling and floor.
Item Description Qty. Unit Rate Amount
33 Grouting with 1:3 cement mortar for anchor bolt pockets machine 5.00 Cum 3628.63
bases, pipe sleeves, pocket holes etc. including roughening and
cleaning of concrete surfaces curing etc. complete.
34 Providing, Cement vata (10 cm. X 10. cm. size) quarter round in 44.00 Rmt 24.28
cement motar 1:1 including neat cement finishing, watering etc.
35 Providing 100 mm x 100 mm size vata in cement concrete (1:2:4) 18.00 Rmt 41.00
including water proofing compounds, smooth finish, curing, etc.
complete for the internal side of the sump, pump house and
chlorination room.
36 Supplying & fixing insert plate of size 150 x 150 x 6 mm in wall 5.00 No. 74.00
alongwith ISA 100 x 100 x 8 mm angle in position for support of
vertical delivery pipe, as per drawing including handling and
transporting etc. complete.
37 Providing and fixing 1.20 Metre high fencing with 2.0 Metre long M.S. 80.00 Rmt. 391.93
Angle posts 40 mm x 40 mm x 6 mm and oil painting 3 coats fixed at
2.5 Mt, C/c with five Horizontan line sand two diagonals of galvanised
steel barbed wire weighting 9.38Kg. per 100 Metre, strained and fixed
to posts with G.I,staples including fixing the posts in ground with 0.5 M
x 0.5.M x 0.5 M. block in C.C 1:5:10 etc complete.
38 Fabricating and fixing in position MS structural section such as flat, 350.00 Kg. 91.08
pipes, plates, hold fast, anchoring bolts / bars of required size
including fixing, welding and two coats of approved anti corrosive
paint over prime coat of red-oxide including RCC gate column as per
drawing etc. complete as directed by Engineer-in-charge.
a) 1.2 m height and 3 m wide main and wicket gate
Construction of Sewage Pumping Station (O-2)
Item Description Qty. Unit Rate Amount
Excavation for well/pumping station including removing and spreading 150.00 Cum 147.20
the excavated stuffs directed with all lead.
loose or soft Soil
From 0.0 to 1.5 m. Depth
1.1 From 1.5 to 3.0 m. Depth 57.00 Cum 162.15
Excavation for well/pumping station including removing and spreading 57.00 Cum 328.90
the excavated stuffs directed with all lead
From 1.5 to 3.0 m. Depth
2.1 From 3 to 4.5 m. Depth 130.00 Cum 345.00
2.2 From 4.5 to 6.0 m. Depth 41.00 Cum 364.55
2.3 From 6 to 7.5 m. Depth 3.00 Cum 386.40
3 Refilling with available excavated earth including ramming, watering, 378.00 Cum 25.30
consolidating disposal of surplus stuff as directed within a radium of
Km. Refilling as directed
4 Filling in plinth with sand under floors including water ramming, 20.00 Cum 481.80
consolidating and dressing complete.
Extra for dewatering for excavation in wet condition and in all strata
From 3 to 4.5 m.
6 Providing and casting in situ C.C. in grade M-15 (approx. corresp. to 2.00 Cum 5441.80
prop. 1:2:4) (proportions as per mix design or as per Table 9 of IS456
2000 in masses by weigh batching ) using granite, quartzite trap metal
of size 6 mm to 20 mm for RCC work, including scaffolding centering,
form work, needle vibrated consolidation, curing comp. up to
meter depth or height (excluding cost of reinforcement and neat
finishing) with centering and shuttering/deshuttering etc. comp. for
structure for other than water retaining.
Footing (Without form work)
Providing and cast in situ C.C. in grade M-30 proportions of ingredients
as per mix design by weigh batching using granite, quartzite trap metal
of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding
centering formwork, needle vibrated consolidation, curing and
hydraulic testing etc. complete (excluding cost of reinforcement) with
centering and shuttering/deshuttering etc. camp. up to 6 meter height
/depth Av. G.L.for all water retaining structures.
Flat bottom slab/floor slab/slab with shuttering
R.C.C. slab and footings
7.1 R.C.C. walls (Above 25 cm) 40.00 Cum 9295.45
7.2 Beams/ ring beams/girders ('R.C.C Beams ) 3.00 Cum 9758.90
Slab & Platform (Flat bottom slab/floor slab/slab with shuttering)
Item Description Qty. Unit Rate Amount
7.4 RCC Column 1.00 Cum 10714.55
7.5 R.C.C. Pedestal (Flat bottom slab/floor slab/slab with shuttering)
8 Providing and cast in situ C.C. in grade M-25 proportions of ingredients 6.00 Cum 9599.05
as per mix design by weigh batching using granite, quartzite trap metal
of size 12 mm to 20 mm and or 6 mm to 12 mm including scaffolding
centering formwork, needle vibrated consolidation, curing and
hydraulic testing etc. complete (excluding cost of reinforcement) with
centering and shuttering/deshuttering etc. camp. up to 6 meter height
/depth Av. G.L.for all water retaining structures.
R.C.C. beams, lintels and bracket for gantry or chain pully blocks, plinth
beams, tie beams.
R.C.C. slabs and platform (Flat bottom slab/floor slab/slab with 4.00 Cum 9288.55
8.1 shuttering)
R.C.C. weather shed, pardi & staircase (Flat bottom slab/floor slab/slab 1.00 Cum 9288.55
8.2 with shuttering)
8.3 R.C.C. columns 4.00 Cum 10574.25
9 Providing and casting in situ C.C. in grade M-20 (proportions as per mix 5.00 Cum 6348.00
design or as per table9 of IS456 2000 in masses by weigh batching )
using granite, quartzite trap metal of size 6 mm to 20 mm for RCC
work, including scaffolding centering, formwork, needle vibrated
consolidation, curing complete (excluding cost of reinforcement and
neat finishing) with centering and shuttering/deshuttering etc.
complete for structure other than water retaining (Below G.L)
Footing for column or foundation (with form work)
10 Supplying cutting, bending, binding and placing in position steel as per 13.00 MT 89129.60
plan and design and as per ISS 2502 including cost of steel and binding
wire for reservoirs/structures only including lift below G.L. for all
Do - deformed (TMT) bars confirming to relevant IS Fe - 500 grade
for all diameters.
11 Providing and fixing water tight construction or expansion joints 150 70.00 Rmt 379.50
mm. dia. Wide thin ribbed PVC.
12 Half brick masonry in common brunt clay building bricks having 5.00 Sq.Mt 629.84
crushing strength not less than 35 Kg/Sq.Cm. In Cement mortar 1:4 (1-
Cement : 4 -coarse sand ) in foundation and plinth (B) Conventional.
12.1 Extra for half brick masonry in superstructure above plinth level upto 5.00 Sq.Mt 54.43
floor two level. (B) Conventional
13 Brick work using common burnt clay building bricks having crushing 18.00 Cum 4214.32
strength not less than 35 kg./Sq.Cm. in foundation and plinth in
Cement Mortar 1:6 (1- Cement : 6 -fine sand) (B) Conventional
14 Extra for brick work in superstructure above plinth level upto floor two 18.00 Cum 281.72
level (B) Conventional
Item Description Qty. Unit Rate Amount
15 Providing and applying 20 mm thick inside OPC cement plaster with 130.00 Sq.Mt 303.00
water proofing agent on inside of sump consisting of 12 mm thick
backing coat of CM 1:3 (1 cement : 3 sand) and 8 mm thick finishing
coat of CM 1:1 (1 cement : 1 sand) etc. complete including necessary
curing, scaffolding required if any etc. complete.
16 Providing and applying 20 mm thick sand faced cement plaster at 132.00 Sq.Mt 342.41
outside RCC / brick on work upto height 10 mtr. above ground level
consisting of 12 mm thick backing coat of C. M. 1:3 (1 cement : 3 sand)
and 8 mm thick finishing coat of C. M. 1:1 (1 cement : 1 sand) etc.
17 Providing and applying 10 mm thick cement plaster in single coat on 25.00 Sq.Mt 145.65
concrete work for interior plastering upto floor two level finished even
and smooth in Cement mortar 1 : 3 (1 cement : 3 sand) in a single coat
over RCC slab (on ceiling) etc. complete as directed (In ceiling of pump
18 Providing 15mm thick cement plaster in single coat on Rough 97.00 Sq.Mt 246.05
(Similar)side of single or half brick walls for interior plastering upto
floor two level and finished even and smooth in (i) Cement mortar 1:3
(1-cement:3-sand) for finishing with a floating coat of
neat cement slurry.
19 Providing and laying 40 mm thick cement concrete flooring in 1:2:4 (1 27.00 Sq.Mt 305.58
cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
including water proofing compound finishing with a floating of neat
cement etc. complete laid in one layer finished including necessary
curing with sulphate resistant cement.
20 Providing and laying 40 mm thick heavy duty cement concrete flooring 1.00 Sq.Mt 373.75
in 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) with ironite powder including finishing with a floating of
neat cement etc. complete.
21 Providing and laying polished Kota stone slab 25 mm thick in riser of 11.00 Sq.Mt 1109.07
steps, dado & pillars, skirting, laid on 10 mm thick cement mortar 1:3
(1 cement : 3 coarse sand) and jointed with grey cement slurry
including rubbing and polishing etc. complete
22 Distempering in 3 coats with oil bound distemper of approved brand 122.00 Sq.Mt 106.92
and manufacture and of required shade on wall surface to give an even
shade over and including a primer coat with distemper primer of
approved brand, thoroughly brushing the surface free from mortar
dropping and other foreign material and also inclusive of preparing the
surface even and smooth etc. complete,
Item Description Qty. Unit Rate Amount
23 Providing and applying epoxy paint of approved make to concrete 130.00 Sq.Mt 103.50
surface for RCC structure including cleaning the surface by scrapping
and air blowers to the satisfaction of Engineer-in -charge necessary
scaffolding etc. complete with all leads and lifts and giving satisfactory
hydraulic test for water tightness as per IS codes. For new surface-Two
24 Wall painting (two coats) with plastic emulsion paint of approved brand 132.00 Sq.Mt 94.33
and manufacture of undercoated wall surface to give an even shade
including thoroughly brushing the surface free from mortar dropings
and other foreign matter and sand papered smooth.
25 Providing and fixing window having extruded aluminum Colour 3.00 Sq.Mt 1583.95
anodized section frame main outer size 95mm x 24mm x 1.17 mm (of
Jindal Section no : 2459 @ wt. of 0.738 Kg/mt), horizontal Three track
member size 92mm x 31.75 mm x 1.30 mm (of Jindal Section no.
@ Wt. 1.07 Kg/mt), vertical member of size 92mm x 31.75mm x
mm (of Jindal Section no. 8933, @ Wt. 1.06 Kg/mt.) with sliding
shutters of horizontal member size 40mm x 18mm x .29 mm (of Jindal
section no. 8947 @ wt. 0.456 Kg/mt.) vertical member of size 40mm x
18mm x 1.29mm (of Jindal Section no. 8949 @ wt. of 0.456 Kg/mt with
5 mm thick transparent bronze colour tinted float glass with powder
coated aluminum fittings and fixtures and transparent silicon sealant
glass fixing to frame as per details etc.
26 Providing and fixing 50 cm wide M.S. Ladder fabricated from M.S. Flats 7.00 Rmt 3392.50
10 mm x 75 mm with 20 mm dia steel bar steps in double rows, @
em C/C. The include stays of 10 mm x 50 mm flats fixed at 3 meter
C/C wtih welding anchoring and 3 coats anticorrosive paint. (M.S.
ladder (without safty cage))
Item Description Qty. Unit Rate Amount
27 Providing & fixing in position aluminum fully paneled doors with 15 5.00 Sq.Mt 3054.24
micron natural matt brush finish anodized as per over all size shown on
the drawings and aluminum sections of approved make conforming to
IS:733 and IS : 1285, made out of 102 mm x 45 mm x 1.90 mm thick
aluminum outer frame section weighing 1.640Kg/m. and shutter
sections with bottom / lock rail 96 mm x 45 mm x 2.7 mm, top rail
mm x 45 mm x 2.70 mm weighing 1.38 Kg/m. vertical styles 48 mm x
45 mm x 1.90 mm weighing 0.976 Kg/m. with rounded sides, fixed with
roll plugs and screws or with fixing clips, or with expansion hold esters
including necessary filling up of gaps at junctions, at top, bottom and
sides with required PVC/neoprene felt etc. and aluminum snap beading
for glazing / paneling, C. P. brass/stainless steel screws, including
standard anodized aluminum fittings and fixtures of approved make
and of adequate size and in adequate numbers, double action floor
springs of approved make for each shutter with standard pivot panels
of 12 mm thick pre-laminated three layer medium density, exterior
grade particle board (termite proof, water proof and fire proof)Grade
1, Type II conforming to IS : 12823 bounded with phenol formaldehyde
synthetic resin, of approved make including cost and fixing of fixtures
etc. complete as per detailed drawings with all lead and lifts.
28 Providing and fixing 40mm dia. GI pipe medium weight quality as 22.00 Rmt 1784.00
openable type with angle iron support at 1.5 m c/c using 75 x 75 x
mm angles, 1 m long with three rows of pipes as railing including
necessary painting with two coats of approved quality oil paint over
one coat of approved primer including necessary welding, bolting
required, if any.
29 Supplying, cleaning, cutting, bending, welding, 'fabricating, erecting 920.00 Kg 99.00
structural steel in position irrespective of locations and levels as per
drawing including handling and transport etc. complete including
applying two coats of primer red oxide and two coats of approved
quality of paint over it etc. complete as directed for gentry girder,
platform, stairs, chequered plate for cable trench etc.
30 Providing and fixing MS grating with 8 mm thick 50 mm wide flat at 50 5.00 Sq.Mt 12590.00
mm c/c to form grid pattern as specified and wherever directed
including two coats of approved quality oil paint with one coat of
primer red oxide etc. complete.
31 Providing and fixing plastic moulded reinforced steps with 10 mm TOR 40.00 No. 87.00
steel bar with plastic polyproclene (P.P.) material (vergin) etc.
32 Providing and fixing to wall, ceiling and floor 10.0 kg.F/cm2 working 10.00 Rmt 252.22
pressure polythene pipes of the following outside Dia. Low density
complete with special flange compression type fittings, wall clips etc.
including making good the wall ceiling and floor.
Item Description Qty. Unit Rate Amount
33 Grouting with 1:3 cement mortar for anchor bolt pockets machine 5.00 Cum 3628.63
bases, pipe sleeves, pocket holes etc. including roughening and
cleaning of concrete surfaces curing etc. complete.
34 Providing, Cement vata (10 cm. X 10. cm. size) quarter round in cement 20.00 Rmt 24.28
motar 1:1 including neat cement finishing, watering etc. complete
35 Providing 100 mm x 100 mm size vata in cement concrete (1:2:4) 16.00 Rmt 41.00
including water proofing compounds, smooth finish, curing, etc.
complete for the internal side of the sump, pump house and
chlorination room.
36 Supplying & fixing insert plate of size 150 x 150 x 6 mm in wall 5.00 No. 74.00
alongwith ISA 100 x 100 x 8 mm angle in position for support of vertical
delivery pipe, as per drawing including handling and transporting etc.
37 Providing and fixing 1.20 Metre high fencing with 2.0 Metre long M.S. 80.00 Rmt. 391.93
Angle posts 40 mm x 40 mm x 6 mm and oil painting 3 coats fixed at
2.5 Mt, C/c with five Horizontan line sand two diagonals of galvanised
steel barbed wire weighting 9.38Kg. per 100 Metre, strained and fixed
to posts with G.I,staples including fixing the posts in ground with 0.5 M
x 0.5.M x 0.5 M. block in C.C 1:5:10 etc complete.
38 Fabricating and fixing in position MS structural section such as flat, 350.00 Kg. 91.08
pipes, plates, hold fast, anchoring bolts / bars of required size including
fixing, welding and two coats of approved anti corrosive paint over
prime coat of red-oxide including RCC gate column as per drawing etc.
complete as directed by Engineer-in-charge.
a) 1.2 m height and 3 m wide main and wicket gate
Mech, Elec., Instrumentation Work for Pumping Station -01
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
1 MECHANICAL WORK 2 Set 3,81,660
SUBMERSIBLE NON-CLOG PUMP SET
Supply, Installation, Testing and Commissioning (SITC) of Submersible NC Pump-Motor
set suitable for sewage application with semi-open or enclosed or suitable type Impeller
& wear Rings in CF8M with CI FG 260 Casing & casing cover, SS 410 shaft & with motor
suitable for 3-Phase, 415 V, 50 Hz., AC induction Air filled dry type submersible motor of
mini. rating as specified having max. 1500 RPM sync. speed, insulation Class 'F' With
temp. rise limited to class B and IP-68 protection.
The scope shall include all required accessories viz. automatic coupling device, SS-304
heavy duty & of suitable size double guide pipes of length to suit the sump height with
required supports, SS-304 or suitable stainless steel grade Chain with shackles (shall be
with dual hook / shackles of 100 mm or suitable higher size at app. every 1.5m C-C
distance) & of length as per sump height + min. 2m, Submersible Power & control cable
(copper flexible & stranded type conductor of reqd. cores & size for each pump motor
set) & length of sump height + min. 5 m long each run with necessary electrical
termination connection at junction box/starter panel and RCC foundation blocks for auto
coupling & delivery bend, PMU etc. complete as per IS and Specification and also
including in scope any other parts/accessories / fittings required to complete the work in
all respects & satisfactory operation of pump set.
Pump Capacity: 150 m3 / hr., (Pump Type-1),
Motor Rating: min. 15 kW (or higher rating as reco. by pump mfg.)
Overall Efficiency at Duty- min. 56%
2 Item Description as per 1.1.1 for SITC and suitable for following duty parameters 2 Set 4,84,957
complete in all respect.
Pump Capacity : 225 m3 / hr. (Pump Type-2),
Motor Rating: min. 22 kW (or higher rating as reco. by pump mfg.)
Over all Efficiency at Duty- min. 59%
3 VALVES: 2 Nos. 6,521
SITC of CI/DI Double Flange Manually operated Sluice Valve as per IS 14846, PN 1.0 of
following sizes with SS 304 seat rings, SS spindle with all hot dipped galvanized
hardwares, bolts, nuts & washers, gaskets including all taxes, etc. complete as per IS and
Size: 150 mm NB (At delivery of Type-1 Pump) - Manually operated
4 Item description as per Sr.No.-2.1.1 and of following, 2 Nos. 10,666
Size : 200 mm NB (On delivery of Type-2 Pump) - Manually operated
5 Item description as per Sr.No.-2.1.1 and of following, 1 No. 21,696
Size : 300 mm NB (On Common Header) - Manually operated
6 SITC of Non-slam, flanged, single door, swing type Non Return Valve conforming to IS 2 Nos. 8,700
5312, Part 1 having pressure rating PN 1.0, having CI/DI body and door, CF8M seat rings
along with all necessary hardwares and complete as per IS and Specification.
Size: 150 mm NB (At delivery of Type-1 Pump)
7 Item description as per Sr.No.-2.2.1 and of following, 2 Nos. 16,782
Size : 200 mm NB (On delivery of Type-2 Pump)
8 SITC of approved make CI/DI Temper proof Flanged Air Valve with Isolation Sluice Valve 1 No. 14,249
as per AWWA / IS 14845, PN-1.0 & IS-14846 PN-1.0 respectively with SS304 float, gun
metal nozzle, complete hardware's, bolts, nuts & washers, gaskets etc. complete as per IS
and Specification.
Size: 80 mm NB (On header after flow meter)
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
9 SITC of Flange ends Expansion Bellow (PN 1.0) as per EJMA standards and as per specs. 2 Nos. 4,656
and complete in all respect.
Size : 150 mm NB X 300 mm L (On delivery of Type-1 Pump)
10 Item description as per Sr.No.-3.1.1 and of following, 2 No. 6,216
Size : 200 mm NB X 300 mm L (On delivery of Type-2 Pump)
11 Item description as per Sr.No.-3.1.1 and of following, 1 No. 10,200
Size : 300 mm NB X 300 mm L (On Common Header near MSV)
12 DI PIPES 20 Rmt 2,986.00
Supply, installation, testing, commissioning of double flanged DI Pipes confirming to IS
8329-2000, class K9 with connections complete for delivery line, header lines as per site
& as per specifications. The scope also includes connection with main header to rising
Size: 150 mm dia.
13 Item description as per Sr.No.-4.1.1 for SITC of: 20 Rmt 3,898.00
Size: 200 mm dia.
14 Item description as per Sr.No.-4.1.1 for SITC of: 10 Rmt 6,546.00
Size: 300 mm dia.
15 Item description as per Sr.No.-4.1.1 for SITC of: 5 Rmt 10,668.00
Size: 400 mm dia.
16 DI FITTINGS 895.3 kg 155.00
Supply, installation, connection with delivery / header, testing and commissioning of
Flanged DI Fittings and Specials like 90 deg. Bend, Drilled / Blind Flanges, Reducer /
Enlarger, TEE, etc. as required to complete the piping and connection of pumps with
header to rising main conforming to IS
Size: 80 mm to 300 mm dia.
17 Item description as per Sr.No.-4.2.1 for SITC of: 100 kg 158.00
Size : 350 mm dia. & Above
18 Flanged Joints of Pipes, Fittings and Specials: 12 Nos. 703
Supply, Installation, Making of Flanged CI / GI / MS Pipes, Fittings and Specials Joints with
all jointing materials, rubber packing, nut bolts, labour etc.for complete connection.
Size: 150 mm dia.
19 Item Description as per 5.1.1 and of following size complete in all respect. 12 Nos. 963
Size: 200 mm dia.
20 Item Description as per 5.1.1 and of following size complete in all respect. 10 Nos. 1,406
Size: 300 mm dia.
21 Item Description as per 5.1.1 and of following size complete in all respect. 1 No. 1,954
Size: 400 mm dia.
22 MONORAIL EOT WITH ELECTRIC CHAIN HOIST 1 No. 2,28,220
SITC of Electrically Operated Chain Hoist & Electrically operated Trolley, suitable to
operate on Mono Rail Girder having motorised motion, manufactured as per IS:6547-
1972-Class-II & IS-3177- Class-II, complete with brake, chain-gear, motors, safety device,
pendant push button, starter panel, cables from motor to starter panel and all other
required accessories like limit switches, power supply system (Fastoon cable type),
fasteners, epoxy painting, etc. tested for overload as per IS and as per specifications,
complete in all respect.
Capacity: min. 1.0 Ton. (For Subm. NC Pump set)
Lift: min. 10-15 m or as per site req.
Bay Length: min. 8-10 m or as per site req.
(w/o MONORAIL GIRDER & MS supporting structure)
Note: Minimum as specified capacity or higher as per requirement such that EOT with
ECH capacity is min.1.25 times of the pump /motor OR single heaviest component to be
lifted within pump house.
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
23 Item Description as per 6.1.1 and of following size complete, 1 No. 2,28,220
Capacity: min. 1.0 Ton. (For Manual Screen)
Lift: min. 10-15 m or as per site req.
Bay Length: min. 8-10 m or as per site req.
24 SLUICE GATE 2 No. 3,68,580
SITC of Manually gear operated C.I. Thimble mounted Sluice Gate conforming to AWWA
C 501 or IS: 13349 - 1992 Class - 1 with rising spindle, single faced, wall thimble
mounted, handwheel, Conventional Type Closure, flange back frame, headstock, Spindle
with supports brackets having length as specified or to suit site condition, suitable for
seating as well as unseating water head, complete in all respect.
Size: 600 mm X 600 mm - approx. 4.5m spindle length (At Inlet Pipe)
25 SITC of Box Type Manual mesh Screen having following size, made of SS 304 material 1 set 3,23,310
having round bars of size min. 9.0 mm dia with clear bar opening as specified here below,
suitably welded in outer frame of equal Leg SS angle of size 50 mm x 50 mm x 6 mm thick
or higher, with intermediate support at required locations, complete as per specs. & shall
also including followings:
The screen shall be with SS perforated Screening Material Collection Box at bottom end
of Screen having size as specified, fabricated from 3 mm thk SS sheet, screen shall be
suitable to slide complete screen through rollers between existing guide passage of MCP
400, embedded/ fixed in wall on both sides of RCC wall up to top of chamber with all
necessary hardware, SS nuts, bolts & wahsers, sacrificial Brass lugs on sides, min. two
lifting lugs/hooks & SS lifting chain having intermediate link/chain of 100 mm dia. at
every 1.5 m distance with shackle, etc. complete in all respects and provided with 1 set
of cleaning rake with each screen, complete as per specification and complete in all
Screen Size: 900 mm (W-or actual chamber width as per site) x 1200 mm (H) x 300 mm
Box Size: 900 mm (W-or actual screen width) x 200 mm (H) x 300 mm (D)
Opening: 50 mm x 50 mm sq. opening
Note : 1. Screen suitable for 1000 mm wide screen chamber or to suit site requirement.
(w/o Guide channel & MS supporting structure)
26 Providing, Supply of Structure Steel at site of work with freight, loading, unloading 1000 kg. 64.84
carting, etc. including all taxes and duties complete such as joints, channels, angles, Iron
Rails, ISA/ISMC/ISMB/MS flat, Plates, Chequered plates (below 8mm thickness) for cable
trench etc. required for support structure of all Electro-mechanical equipment, piping,
etc. for support on floor / wall / beam / brackets etc. as per tender and IS.
27 Labour Charges for lowering, laying, Fixing with fabrication various size section of MS 1000 kg. 13.07
such as joints, channels, angles, Iron Rails, ISA/ISMC/ISMB/MS flat, Plates, Chequered
plates, for cable trench etc Complete with two coats of red oxide and two coats of
approved colour shade of epoxy paint as per relevant IS and as per specification.
TOTAL OF MECHANICAL WORK WITHOUT GST
28 ELECTRICAL WORK 1 Set 38,952.11
TPN MCCB (For LT Service Obtaining Requirement)
SITC of 250A TPN microprocessor MCCB, LSIG (50kA) with inbuilt O/L, S/C & E/F
protection with Extended rotary handle, Terminal spreader, Auxiliary change over & Trip
contact, with Outdoor Enclosure with canopy 2mm thick , Single/double door & Wall
mounted/ stand mounted as per site requirement (with incoming & outgoing cable entry
at bottom )with Cable end boxes with RYB indicating lamp, Digital voltmeter, VSS,ON,OFF
& Trip indicating lamp etc as per Power supply company requirements & location.
Including all civil works for fixing of panel on wall.
(Wall mounted at Location as per PSC req.)
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
29 MEDIUM VOLTAGE PANEL BOARD (PMCC /APFC) 1 Set 6,51,000.00
SITC of PMCC Panel (50kA), compartmentalized, floor mounted, operating height
maximum 1800/1900 mm, Extensible on both ends, suitable for Manual & Auto
operation -Local & through PLC/SCADA operation as per site conditions complete in all
respects as per Tender SLD / Specification / IS and including following as minimum:
(1) One no. Incoming feeder FP 250A Microprocessor MCCB (50kA), LSIG, with inbuilt
O/C, S/C, & E/F protection for I/c with Digital Voltmeter, Voltmeter selector switch,
Digital Ammeter, Ammeter selector switch, Power Factor Meter, MFM with RS-485 of
Class-0.5, Indicating lamps R,Y,B,On,off,Trip, 3nos. 250A/5A, Cl.-0.5 metering CT, CL
CT for APFC relay etc. Constant voltage/control voltage transformer 1500VA, 415V/230V
AC, with tapping +/-5% in steps of 2.5%, 32A DP MCB complete in all respects. (2) 250A
TPN Main Aluminium busbars. (main busbars size with current density 0.8A/Sq.mm)
(3) 22 KW STAR -DELTA STARTER FEEDER (SUBM.): 2 NOS
22 KW or higher as per pump manufacturer recommendation Star-delta starter with
100A TPN Thermal magnetic MCCB with Adjustable O/L & Adjustable S/C protection, 95A
AC3 duty contactors (3 nos.), O/L Relay, star-delta timer, Ammeter with ASS, Resin Cast
CT Cl: 0.5(3 nos.),SPP,PMU, A/M, L/R switch, ON, OFF, TRIP Indication & Start, E-Stop &
Reset pushbutton etc. for S/D starter. complete in all respects.
(4) 15 KW STAR -DELTA STARTER FEEDER (SUBM.): 2 NOS
15 KW or higher as per pump manufacturer recommendation Star-delta starter with 80A
TPN Thermal magnetic MCCB with Adjustable O/L & Adjustable S/C protection, 80A AC3
duty contactors (3 nos.), O/L Relay, star-delta timer, Ammeter with ASS, Resin Cast CT Cl:
0.5(3 nos.),SPP, PMU, A/M, L/R switch, ON, OFF, TRIP Indication & Start, E-Stop & Reset
pushbutton etc. for S/D starter. complete in all respects.
29 (5) 63A TPN TM MCCB FEEDER : 1 No. ( for Spare) rate incl in
Each feeder comprising of 63A TPN Thermal Magnetic (TM) MCCB, with indicating lamp above price
(6) 32A TPN TM MCCB FEEDER : 2 Nos. (1 no. EOT with ECH at Pump house, 1 no.
Each feeder comprising of 32A TPN Thermal Magnetic (TM) MCCB, with indicating lamp
(7) 63A TPN TM MCCB FEEDER FOR ALL MCB FEEDERS: 1 set:
Incomer: 63A TPN Thermal Magnetic (TM) MCCB, with indicating lamp etc.
7.1) 3 nos. 32A 'C' curve 4P MCB feeders (for 1 no. Ind LDB, 1 no. ICP/PLC panel & 1 no.
7.2) 1 no. 32A 'C' curve 4P MCB with Time switch,32A contactor 4P,ON lamp feeders (for
(8) APFC separate cubical compartment (minimum 30 KVAr) having 1 no. 63A TPN
Thermal magnetic MCCB 50KA with adjustable overload and adjustable short circuit,
step APFC relay with RS 485, 1 no. 63 A/5A, Cl.-1.0 CT for Ammeter, Digital Ammeter,
ASS, 1 no. 1 kVAR capacitor with 16A TPN D curve MCB, 2 nos. 2 kVAR capacitor with 16A
TPN D curve MCB, 3 nos. 5 kVAR capacitor with 16A TPN D curve MCB,1 no. 10 kVAR
capacitor with 32A TPN D curve MCB with capacitor Duty Contractor, A/M switch, On
delay timer, Push Buttons etc. Complete in all respects as per Specification, IS & SLD.
(9) Multiplication relay as required for dry run protection of pumps.
NOTE: 1). All MCCB shall be 50KA, Ics = 100% Icu, inbuilt protection with adj O/L and
Adj.S/c (LSIG for MP MCCB),Extended rotary handle, Terminal spreader, Auxiliary Change
over contact and trip contact as required.2) All MFM, ACB, Soft Starter,Temp.Scanner etc
shall be with inbuilt RS
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
30 SITC of Lighting Distribution Board (LDB) as under: 2 Nos. 7,497.69
SITC of 3 Phase 4 Wire 4P, double door Prewired LDB each for Indoor Lighting & Outdoor
Lighting Suitable to house :
Incoming: 32A FP, ELMCB (30mA)
Outgoing: 20A SP MCB (9 nos.) & 16A SP MCB (9 nos.)
31 SITC of LCS pushbutton station ON & OFF (E-stop) set complete with Enclosure, 4 Nos. 2,008.47
necessary mounting/ fixing arrangement on wall / pipe support etc. to be installed near
motors for remote operation, etc. as per IS and specifications. (including structural steel)
32 SITC of stand / wall mounting type MS Junction Box, minimum 2.5mm thick, with 4 Nos. 1,906.78
detachable cable gland plate of 3mm thick, duly powder coated, with earthing terminals,
steel structure stand for mounting of JB, etc. for Jointing/Termination suitable for 1.1 kV
Submersible Flexible Copper Power cable with Aluminium/ Copper armoured power
cable from PMCC . Scope shall include providing suitable rating AL busbars, Support
insulators, Crimping type lugs,nuts,bolts,washers etc. complete in all respects as
instructed by E.I.C. Drawing shall be got approved before SITC of the same. Lugs of
cables shall not be connected directly. (Structure steel for Stand shall be measured
separately) JB of minimum Size: 300mm x 300mm x 100mm or higher as required. or
higher as required (for Pump)
33 SITC of stand / wall mounting type MS Junction Box, minimum 2.5mm thick, with 4 Nos. 1,906.78
detachable cable gland plate of 3mm thick, duly powder coated, with earthing terminals,
steel structure stand for mounting of JB, etc. for Joining/Termination suitable for 1.1 kV
Submersible Flexible Control Cables of Submersible pump with control cable from PMCC.
Scope shall include providing Terminal connectors for connecting control cable, copper
lugs, etc. complete in all respects as instructed by E.I.C. 20% additional/spare Terminal
connector shall be provided. Drawing shall be got approved before SITC of the same.
SMC/FRP/Bakelite separator shall be provided between Power cable section & Control
cable section. Lugs of cables shall not be connected directly (Structure steel for Stand
shall be measured separately).
JB of minimum Size: 300mm x 300mm x 100mm or higher as required. or higher as
required (for Pump)
34 LOW VOLTAGE (LT) CABLES 25 Mtr. 783.00
Supply, laying, testing and commissioning of 1.1 kV, A2XFY(X)/2XWY(X) XLPE insulated (IS
7098) AL / Cu stranded conductor, Extruded innersheath cables as per specification & IS.
The cable when laid outside the building shall be laid underground in trench with brick &
sand protection/in DWC pipes as per specified method and shall be laid in prepared
trench/ on cable tray when laid inside the building.
SITC of 3.5C x 240 sq. mm. A2XFY(X) Cable (1 run for MCCB to PMCC panel)
35 3C x 6 sq. mm. A2XWY Cable (2 runs for PMCC to 2 nos. 22 kW Subm. pump Junction box, 220 Mtr. 70.00
2 runs for PMCC to 2 nos. 15 kW Subm. pump Junction box)
36 4C x 6 sq. mm. A2XFY(X) Cable (For 1 no. Indoor LDB, Outdoor LDB & for 3 nos. street 120 Mtr. 78.00
37 4C x 2.5 sq. mm. 2XWY/2XFY(X) Cable (For 1 no. TPN MCCB for EOT with ECH at Pump 150 Mtr. 81.00
House, 1 no. ICP/PLC panel, 4 nos. pump PMU)
38 5C x 1.5 sq. mm. 2XWY(X) Cable (For 4 nos. of pump LCS) 110 Mtr. 130.00
39 2C x 2.5 sq. mm. Multi strand 2XWY(X) Cable (APFC sensing C.T) 20 Mtr. 177.12
40 Single core 95sq. mm. PVC insulated circular unsheathed copper conductor flexible 20 Mtr 910.12
Cable (For Power supply Metering Panel to I/c MCCB Unit)
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
41 CABLE END TERMINATION AND CONNECTION: 2 Nos. 838.00
SITC of Double compression Ni-Plated brass cable glands and crimping type Bimetallic
lugs / sockets with necessary tools and equipments as specified in specifications and IS.
The glands and lugs / sockets shall be suitable for cable size and type mentioned below
& as per specifications.
1) Earthing the glands and armouring with earthing clamp and jumper and also
connecting to common earth bar.
2) The job also includes, if necessary, supply & fixing of extension busbar of same
material on MCCB or panel board terminal / connector to connect more than one no. of
parallel cables or to connect higher size cable to lower size unit. The job also includes
earthing the glands and armour of the cable with common earth bar or flexible copper
mesh.(Cable termination qty. shall be as per site requirement)
3.5C x 240 sq. mm. A2XFY(X) Cable (1 run for MCCB to PMCC panel)
42 3C x 6 sq. mm. A2XWY Cable (2 runs for PMCC to 2 nos. 22 kW Subm. pump Junction box, 16 Nos. 110.00
2 runs for PMCC to 2 nos. 15 kW Subm. pump Junction box)
43 4C x 6 sq. mm. A2XFY(X) Cable (For 1 no. Indoor LDB, Outdoor LDB & for 3 nos. street 10 Nos. 111.00
44 4C x 2.5 sq. mm. 2XWY/2XFY(X) Cable (For 1 no. TPN MCCB for EOT with ECH at Pump 12 Nos. 65.15
House, 1 no. ICP/PLC panel, 4 nos. pump PMU)
45 5C x 1.5 sq. mm. 2XWY(X) Cable (For 4 nos. of pump LCS) 8 Nos. 130.00
46 2C x 2.5 sq. mm. Multi strand 2XWY(X) Cable (APFC sensing C.T) 2 Nos. 49.13
47 Single core 95sq. mm. PVC insulated circular unsheathed copper conductor flexible 10 Nos. 47.11
Cable (For Power supply Metering Panel to I/c MCCB Unit)
48 CABLE TRAY 30 Mtr. 388.00
SITC of G.I. (hot dip galvanised )Ladder type medium duty (2mm thick) Cable Tray with
necessary bends, tees, reducers, covers and clamps for fixing. All material shall be Hot
dip galvanised as per Specification. And including all accessories.
300 x 75 mm - Ladder type
49 150 x 50 mm - Ladder type 100 Mtr. 336.00
50 Supply, laying and erection of 75 mm ID approved make Double Walled Corrugated 50 Mtr. 161.15
pipes (DWC) of polyethelene (confirming to IS-14930 II) with necessary connecting
accessoies of same material at required depth for laying of cable below ground / road
surface for enclosing cable and back filling the same to make ground as per original. (LT
51 Cable Trench, Laying & Installation of Cable: Making cable trench in soft soil of suitable 100 Mtr. 46.46
width of 90cms deep for laying cable, Sand cushioning and brick protection on sides and
on top all over the run and back filling the same and making the surface as normal
ground as per IS & Specification. (For laying of LT cable in ground)
52 Cable Protection/ Covering in Trench: Cable Covering with second class bricks or cement 50 Mtr. 133.31
tiles laid cover the cable (top) & also on both side with sand bedding/cusioning of
75mm.& covering of 150mm Layer of sand above cable (16 bricks per meter.) as per IS
& Tender Drg/ Specification. (For HT/LT cable protection) complete in all respects as
instructed by EIC.
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
53 CHEMICAL EARTHING SYSTEM 2 Set 10,494.73
SITC of Maintenance free chemical earthing (copper) with earthpit of minimum bore size
dia. 225mm Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS-
3043:1987 /Tech spec. made of corrosion free Pipes having Outer pipe dia of 48 mm
having 250 Micron copper plating, Inner corrosion free Hot dip galvanised (80 to
micron) pipe dia of 26 mm with copper flat strip type connection terminal 14mm dia
with constant ohmic value surrounded by highly conductive corrosion resistant chemical
compound with high charge dissipation suitable for electrical installation & of 3Mtr.
length of Pipe with two nos. 25Kg. bag of Back filling compound.. (2 nos. for ICP earthing)
NOTE: Earthing Resistance value & date shall be painted on the chamber cover.
54 SITC of Maintenance free chemical earthing with earthpit of minimum bore size dia. 4 Set 7,028.82
225mm Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS-3043:1987
/Tech spec. made of corrosion free Hot dip Galvanised (min 150 Microns) Pipes having
Outer pipe dia of 76 mm , Inner corrosion free Hot dip galvanised (80 to 100 micron)
pipe dia of 26 mm with copper flat strip type connection terminal 14mm dia with
constant ohmic value surrounded by highly conductive corrosion resistant chemical
compound with high charge dissipation suitable for electrical installation & 3Mtr. length
of Pipe with two nos. 25Kg. bag of Back filling compound. (2 nos. for PMCC panel & 2nos.
for all elect. Equipments)
NOTE: Earthing Resistance value & date shall be painted on the chamber cover.
55 SITC of 50mm(w) x 8mm(T) etc. sizes as required, HOT dip galvanized GI Strip including 230 Kg. 77.17
supply & fixing using GI spacers, saddles when laid inside the building and inclusive of
excavation & refilling of earth when laid outside the building & interconnection with
earth pit & all electro-mechanical equipments.
(50X6 G.I Strip wt.2.3 kg/m, 2.3x100Mt.=230kg.)
56 Supply, laying and erection of 25mm(w) x 3mm(T) etc. sizes Copper Strip including 15 Kg. 787.34
supply & fixing of bolts, saddles when laid inside the building and inclusive of excavation
& refilling of earth when laid outside the building & interconnection with earth pit & PLC
panel. (25 X3 Cu. Strip, 0.761 Kg/m, 0.761 x 20mtr.=15.22Kg.)
Copper Bolt,Nuts ,Washers shall be used for Connecting Earth electrode to individual
eqp. Bitumen shall be used at the place of joint/welding. (PLC panel to Earthing)
57 Supply, laying and erection of 25mm(w) x 3mm(T) etc. sizes as required, HOT dip 18 Kg. 77.17
galvanized GI Strip including supply & fixing using GI spacers, saddles when laid inside
the building and inclusive of excavation & refilling of earth when laid outside the building
& interconnection with earth pit & all electro-mechanical equipments. (25X3 G.I Strip,
58 SITC of HOT Dip Galvanized iron strip wire 8 SWG (For LDB,LCS, etc.) 19 Kg. 77.17
(8 SWG G.I Strip, 0.103 Kg/m, 0.103 x 180Mt.=18.54 Kg.)
59 INTERNAL WIRING 80 Mtr. 78.06
SITC of Mains & outlet points wiring with 1.1 kV grade FRLS PVC insulated ISI marked
flexible stranded copper conductor wires with medium class min. 25mm. dia. Electrical
grade PVC pipe and accessories to be erected concealed in / to be run on surface / wall /
ceiling with following sizes as mentioned below. The unit rate wirings shall be with
connector, PVC junction box, wires, holder, ceiling rose, angle holder, switch, sockets,
switch board, brass chromium / cadmium plated machine screws, phase and neutral
wires, green Earth continuity wires etc. as required to complete wiring from LDB panel to
the final outlet termination points. The wiring shall be as per IS:732, IS:4648 and as
per tender specification / IS.
(a) SITC of Mains wiring with 3 wire 1.5 sq.mm.
60 same as above, but (b) SITC of Mains wiring with 3 wire 2.5 sq.mm as per tender 80 Mtr. 96.06
specification & IS.
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
61 same as above, but (c) SITC of Mains wiring with 4 wire 1.5 sq.mm as per tender 70 Mtr. 86.06
specification & IS.
62 same as above, but (d) SITC of Mains wiring with 4 wire 2.5 sq.mm as per tender 70 Mtr. 119.06
specification & IS.
63 SITC of Point wiring for Light / fan / Bell / Primary Point with 2nos. 1.5 sq. mm & earth 21 Nos. 326.59
wire of 1.5 sq. mm (green) both are of ISI marked 1.1 kv grade FRLS PVC insulated
multistrand copper wires , pipe to be erected concealed in flushed on wall / ceiling,
complete with 6A Tissino Type ISI marked flush type switch / bell push & accessories
erected on metal / PVC Box covered with 3 mm thick PC (Polycarbonate) / Acrylic sheet
with necessary lamp holder / ceiling Rose / H. D. connector as directed with medium
class Rigid PVC pipe & accessories.
64 SITC of 6A independent Plug with 2nos. 1.5 sq.mm Cu. Mains size wiring & earthwire of 2 Nos. 288.50
1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand
copper wires with medium class Rigid PVC pipe and accessories to be erected on wall /
ceiling, complete with ISI marked 3 / 5 Pin socket and tissino type switch erected with
earth continuity connection erected on Metal / PVC box covered with 3 mm thick
PC(Polycarbonet) / Acrylic sheet. (2 no. LT cum Pump House)
65 SITC of 6/16A independent Plug with 2nos. 4 sq.mm Cu. Mains size wiring & earthwire of 2 Nos. 565.50
1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand
copper wires with medium class Rigid PVC pipe and accessories to be erected on wall /
ceiling, complete with ISI marked 3 / 5 Pin socket and tissino type switch erected with
earth continuity connection erected on Metal / PVC box covered with 3 mm thick
PC(Polycarbonet) / Acrylic sheet. (2 no. LT cum Pump House)
66 SITC of One 300/380 mm dia. Ex fan 16A independent Plug point near Ex. Fan with 2nos. 4 Nos. 601.60
4 sq.mm Cu. Mains size wiring & earthwire of 1.5 sq.mm (green) both are of ISI marked
1.1 KV grade FRLS PVC insulated multistrand copper wires with medium class Rigid PVC
pipe and accessories to be erected on wall / ceiling, complete with ISI marked 3Pin
socket and tissino type switch erected with earth continuity connection erected on
Metal / PVC box covered with 3 mm thick PC(Polycarbonet) / Acrylic sheet. Plug point
shall be near Ex.Fan.
67 SITC of 380mm sweep 1400 R.P.M exhaust fan, capacitor type, having double ball 4 Nos. 3,052.47
bearing, M.S.blades, mounting frame, forearms, suitable to operate on 230V,50 HZ AC
supply conforming to IS: 2312.Fan shall be painted with epoxy grey colour controlled by
one 6 A flush type switch on board and 6A plug point near Ex. fan.
68 SITC of Single Phase 20A 3 Pin Metal clad Industrial Type Socket with plug top and 20A 2 Nos. 840.00
SPMCB, suitable for flush mounting, in 16 SWG MS box of suitable size and covered with
3 mm thick electrical grade hylam sheet or equivalent ISI marked Electrical grade Bakelite
sheet and earthing with 2.5 sq.mm insulated copper wire run inside the conduit including
interconnections etc. complete as required.
(2 no. LT Room cum Pump House)
69 SITC of Sheets steel powder coated weather proof enclosure with One no. 32A, 415V 4P 1 Nos. 765.39
MCB for Motor & Inductive load (C Curve) having 10 KA breaking capacity & confirms to
IS: 8828. (1 no. for EOT with ECH at P.H.)
70 1200mm sweep ceiling fan, capacitor type, having double ball bearing 450mm down rod, 1 Set 1,581.51
canopies, shackle, rubber bush, blades, electronic speed regulator, suitable to operate on
230V,50Hz AC supply conforming to IS: 374/1979.Fan shall be painted with white
colour.(1 no. LT Room cum at P.H)
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
71 LED LIGHT FIXTURES & LIGHTING: 4 Nos. 293.26
SITC of Indoor wall mounting 20Watt or up to 25% higher wattage LED 4 feet Tube Light
indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA polyester powder coated and high U.V. & corrosion resistance with diffuser
and/or Polycarbonate optics with company mark/name
120 to 300 V,Power Factor more than 0.9, THD < 20 %,
CCT 4000 K to 6500K, Uniformity ratio >0.7,
Luminaries efficacy> 85 lumens/watt
LED driver efficiency > 85 %
(Each fitting required LM-79 & LM-80 Certificates)
Tube Light with integral / non-integral driver, Surge-4KV,IP-20, 4 feet, Cat-III (For 4 nos.
72 Item description as per Sr. No.7.1 SITC of 7 watts LED Lamps integral type,cool white with 1 Nos. 111.00
PC diffuser suitable for B22 LAMP holder (1 no. LT Room cum at P.H)
73 SITC of 40W LED Surface / Wall mounted LED Flood Light fittings with High power 4 Nos. 5,144.28
White LEDs wattage of 1Watt and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth
finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate
optics/ lenses with company mark/name engraved or embossed
120 to 300 V,Power Factor more than 0.95, THD < 20 %, CCT 5000 K to 5700K,
Uniformity ratio >0.45, Luminaries efficacy> 85 lumens/watt . LED driver efficiency >
( Each fittings required LM-79 & LM-80 certificates)
(IP-65), Surge -4KV Cat-III
For Indoor use: (at Pump House)
74 SITC of 'B' class galvanised iron pipe 32 mm outside dia 45 cms long duly welded on 20 9 Nos. 553.86
cms x 20 cms x 3 mm thick M.S. base plate, erected on wall or corner for mounting
luminaries with necessary hardware materials duly painted for wall mounting indoor
flood light fixtures on Wall of Buildings & post top lantern.
75 EXTERNAL LIGHTING (Flood LIGHT): 5 Nos. 6,029.70
SITC of 70W LED Wall mounted LED Flood Light fittings with High power White LEDs
wattage of 1Watt and above assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses
with company mark/name engraved or embossed
120 to 300 V,Power Factor more than 0.95, THD < 20 %, CCT 5000 K to 5700K,
Uniformity ratio >0.45, Luminaries efficacy> 85 lumens/watt . LED driver efficiency >
( Each fittings required LM-79 & LM-80 certificates)
(IP-65), Surge -4KV Cat-III
For Outdoor use: (5 nos. for area lighting)
76 SITC of 40watt, Cat-III Post Top Lantern LED fitting comprises of 650 MM TOP Diameter, 2 Nos. 4,772.85
120 degree beam angle with 3 Nos. Supporting Ribs and with 0.5mt. G.I. fitting pipe (for
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
77 EXTERNAL LIGHTING (STREET LIGHT): 3 Nos. 10618.72
SITC of Street Light Pole, steel tubular swaged type, 7.5 meter long with single arm &
M.S.base plate with pipe cap and over hung 1.5 m long having dia to suit the socket of
240V LED street light fixtures. Street light pole unit rate shall be with (i) IP 65 SMC box of
size 20 x 15 x 15 cms. with MCB & terminal strip inside the box with hinged/sliding door
(ii) 50mm dia, B class GI pipe bracket min.1.5mtr long for Incoming & outgoing cable
(iii)MS Cable Clamp of 25 x 3mm (iv)SITC of 1.5 Mtr.single Arm bracket of medium duty
MS pipe of 4.2 cms. Out side dia complete with suitable sleeve tubing 45 cms. long of
required size of pole top etc. and having spread of 1.5.mtr. length with 110 deg.(v)
Complete painted with one coat of Red oxide / PU base primer and two coats of
Aluminium / PU paint for Pole,Arm, pipe etc.
78 SITC of 70W LED Street light fittings with High power White LEDs wattage of 1Watt and 3 Nos. 5,918.70
above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free
High pressure die cast aluminum housing with smooth finish powder coated and heat
sink extruded aluminium with diffuser and Polycarbonate optics/ lenses with company
mark/name engraved or embossed
120 to 300 V,Power Factor more than 0.95, THD < 20 %, CCT 5000 K to 5700K,
Uniformity ratio >0.45, Luminaries efficacy> 85 lumens/watt . LED driver efficiency >
( Each fittings required LM-79 & LM-80 certificates)
Street Light (IP-65), Surge -4KV, 70 watt Cat-III
79 SITC of M-20 / 1:2:4 cement concrete foundation for Street light pole & 70 % PCC from 3 Nos. 1,282.12
bottom including excavation for the pole of size 60 x 60 x 120 cms. Deep in below ground
level with plinth of 45 cms x 45 cms(or 45 cms dia x 45 cms) high upper ground level with
necessary curing and finishing in approved manner.
80 SAFETY ACCESSORIES 1 No. 8,586.26
SITC of following safety accessories complete with necessary fixing brackets, other
accessories and tools etc. as required to complete the job.
Supply & Erecting carbon dioxide (CO2) fire extinguisher of 6.5kg capacity with necessary
clamps made from 50 x 6 mm M.S. Flat with nut & bolts grouted in wall complete.
(For 1 no. for LT Room)
81 Supplying of standard first AID box with antiseptic cream, medicine for use on wounds 1 No. 297.00
due burn, crepe bandage, guage bandage, medicated ready to use bandage (Band-aid)
adhesive tape for medicinal user, scissors, antiseptic solution (Savlon or similar) etc. (All
above contents shall be of standard makes)
(For 1 no. For LT Room)
82 Supply & fixing of printed instruction (First Aid) Chart both in English and Gujarati and 1 No. 129.06
duly framed with front glasses, for treatment of person suffering from electric shock. (For
1 no. For LT Room)
83 Supply and fixing of 20 W fluorescent lamp operated emergency light with 1 No. 2,730.00
maintenance free battery for 3 hours operation during mains power failure.
(For 1 no. LT Room)
84 Supply and laying of Synthetic Insulating Mat of Class - A of min. thickness 2mm as per 5 Sq.mtr 1,017.00
IS:15652 and with good electrical insulation property for 1.1KV/3.3KV as per site .
requirement. (For LT Panel)
85 Providing pair of rubber hand gloves ISI make suitable for working on 22 KV supply 1 No. 212.00
TOTAL OF ELECTRICAL WORKS WITHOUT GST
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
86 PRESSURE MEASURING SYSTEM 4 Nos. 5,522
Supply, installation, testing & commissioning of Diaphragm Type Pressure Guage having
150 mm dial with necessary fittings/accessories in SS
(manifold valve, nipples etc.) complete in all respects and as per specs.
Range : 0-1.6 Kg/cm2 (at each pump discharge line)
87 LEVEL MEASURING SYSTEM FOR SUMP 1 No. 59,436
Supply, installation, testing and commissioning of Ultrasonic type Level Transmitter
with remote type transmitter with 10meter cable between Sensor and Transmitter
along with all required accessories, Weather proof enclosure for transmitter for outdoor
application, mounting stand , etc. complete in all respects as per specification and having
following measurement ranges for liquid (Sewage) application:
Meas. Range: upto 10 m (at sump )
88 Supply, installation, testing and commissioning of Float type Level Switch along with 10 2 Nos. 12,802
mtr. Cable and WP Junction Box (at sump for dry run protection of pumps through relay
multiplication in PLC, U/S at Manual Screen for High Level alarm), etc., complete in all
respects and as per specification.
Meas. Range: upto 10 m
89 ELECTRO MAGNETIC FLOWMETER MAINS OPERATED 1 No. 1,34,422
Supply, installation, testing and commissioning of Full Bore Electromagnetic flow meter
comprising of IP-68 Sensor , IP-66 remote type transmitter with 20 m cable between
sensor and transmitter along with all mounting accessories, Weather proof enclosure
for transmitter, hardware, mounting stand, etc.
as per specification and to complete the work in all respect as per site condition
necessary connection with pipe and shall have following size.
Meter Size: 300mm NB (At Pump common Header )
Pipe Size : 300 mm NB
90 PLC BASED CONTROL PANEL FOR WDS 1 LOT 6,09,848
Supply, Installation, Testing & Commissioning of PLC Based Instrument control Panel with
panel mounted 10 " colour touch screen HMI, 4G or Latest GPRS modem (Ethernet port
+ SIM Slot, ) with 2 IP Supported, Communication port for MFM. Instrument Control
Panel '(PLC Enclosure / Panel ) with necessary PLC based logic and wiring , 1 no. Panel
Mounted FIQ for flow meter and 1 no. Process Indicator for Level Ta., Min. 1 kVA Online
UPS + CVT (with 60 min min backup alongwith filter for harmonic, suitable rating SMF
inbuilt batteries alongwith battery charger and all other accessories as per standard),
etc. complete in all respects and as per specs with PLC having minimum I/O count of 20DI
/ 8 DO / 4AI /2AO. These are the minimum IO requirement if any other IO,s required to
complete the work contractor shall be provide the same without any extra cost.
91 INSTRUMENT CABLE & ACCESSORIES 50 MTR. 146
'Supply, Laying, Installation, Connection, Termination, Testing & Commissioning of
Instrument Cables as per specs.
The unit rate shall include
a)Supply, loading & unloading of the cable at site from store.
b)Shifitng of cable from site store to place of installation.
c)Fixing of cable clamps, brackets, supports, route markers etc. where ever required to
fix the cables safely.
d)Excavation, back filling and levelling of ground alongwith laying of fine sand, protection
bricks and other necessary civil material for laying cables outside the building.
f)Testing and submission of sketches & reports of all the cables laid.
92 CONTROL CABLE 100 MTR. 330
93 SIGNAL CABLE 100 MTR. 133
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
94 CABLE END TERMINATION AND CONNECTION : 4 Nos. 160
'Supply, fixing, connection, testing and commissioning of double compression brass cable
glands and crimping type Bimetalic lugs / sockets with necessary tools and equipments as
specified in specifications and IS complete in all respects. The glands and lugs / sockets
shall be suitable for cable size and type mentioned above. The job also includes earthing
the glands and armour of the cable with common earth bar or flexible copper mesh as
95 CONTROL CABLE 8 NOS. 230
96 SIGNAL CABLE 8 Nos. 160
TOTAL OF INSTRUMENTATION WORK WITHOUT GST
Mech, Elec., Instrumentation Work for Pumping Station -02
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
1 MECHANICAL WORK 2 Set 3,95,886
SUBMERSIBLE NON-CLOG PUMP SET
Supply, Installation, Testing and Commissioning (SITC) of Submersible NC Pump-Motor set
suitable for sewage application with semi-open or enclosed or suitable type Impeller &
wear Rings in CF8M with CI FG 260 Casing & casing cover, SS 410 shaft & with motor
suitable for 3-Phase, 415 V, 50 Hz., AC induction Air filled dry type submersible motor of
mini. rating as specified having max. 1500 RPM sync. speed, insulation Class 'F' With temp.
rise limited to class B and IP-68 protection.
The scope shall include all required accessories viz. automatic coupling device, SS-304
heavy duty & of suitable size double guide pipes of length to suit the sump height with
required supports, SS-304 or suitable stainless steel grade Chain with shackles (shall be
with dual hook / shackles of 100 mm or suitable higher size at app. every 1.5m C-C
distance) & of length as per sump height + min. 2m, Submersible Power & control cable
(copper flexible & stranded type conductor of reqd. cores & size for each pump motor set)
& length of sump height + min. 5 m long each run with necessary electrical termination
connection at junction box/starter panel and RCC foundation blocks for auto coupling &
delivery bend, PMU etc. complete as per IS and Specification and also including in scope
any other parts/accessories / fittings required to complete the work in all respects &
satisfactory operation of pump set.
Pump Capacity: 255 m3 / hr.,
Motor Rating: min. 18.5 kW (or higher rating as reco. by pump mfg.)
Overall Efficiency at Duty- min. 60%
2 VALVES: 3 Nos. 10,666
SITC of CI/DI Double Flange Manually operated Sluice Valve as per IS 14846, PN1.0 of
following sizes with SS 304 seat rings, SS spindle with all hot dipped galvanized hardwares,
bolts, nuts & washers, gaskets including all taxes, etc. complete as per IS and Specification.
Size: 200 mm NB (At delivery of each Pump & Common Header)
3 SITC of Non-slam, flanged, single door, swing type Non Return Valve conforming to IS 2 Nos. 16,782
5312, Part 1 having pressure rating PN 1.0, having CI/DI body and door, CF8M seat rings
along with all necessary hardwares and complete as per IS and Specification.
Size: 200 mm NB (At delivery of Pump)
4 SITC of approved make CI/DI Temper proof Flanged Air Valve with Isolation Sluice Valve 1 No. 14,249
as per AWWA / IS 14845, PN-1.0 & IS-14846 PN-1.0 respectively with SS304 float, gun
metal nozzle, complete hardware's, bolts, nuts & washers, gaskets etc. complete as per IS
and Specification.
Size: 80 mm NB (on header after flow meter)
5 SITC of Flange ends Expansion Bellow (PN 1.0) as per EJMA standards and as per specs. 3 Nos. 6,216
and complete in all respect.
Size : 200 mm NB X 300 mm L (On delivery of Pump & 1 no. at header)
6 DI PIPES 22 Rmt 3,898.00
Supply, installation, testing, commissioning of double flanged DI Pipes confirming to IS
8329-2000, class K9 with connections complete for delivery line, header lines as per site
& as per specifications. The scope also includes connection with main header to rising
Size: 200 mm dia.
7 DI FITTINGS 297 kg 155.00
Supply, installation, connection with delivery / header, testing and commissioning of
Flanged DI Fittings and Specials like 90 deg. Bend, Drilled / Blind Flanges, Reducer /
Enlarger, TEE, etc. as required to complete the piping and connection of pumps with
header to rising main conforming to IS
Size: 80 mm to 300 mm dia.
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
8 Flanged Joints of Pipes, Fittings and Specials: 20 Nos. 963
Supply, Installation, Making of Flanged CI / GI / MS Pipes, Fittings and Specials Joints with
all jointing materials, rubber packing, nut bolts, labour etc.for complete connection.
Size: 200 mm dia.
9 Item Description as per 5.1.1 and of following size complete in all respect. 1 Nos. 1,158
Size: 250 mm dia.
10 MONORAIL EOT WITH ELECTRIC CHAIN HOIST 1 No. 2,28,220
SITC of Electrically Operated Chain Hoist & Electrically operated Trolley, suitable to
operate on Mono Rail Girder having motorised motion, manufactured as per IS:6547-1972-
Class-II & IS-3177- Class-II, complete with brake, chain-gear, motors, safety device,
pendant push button, starter panel, cables from motor to starter panel and all other
required accessories like limit switches, power supply system (Fastoon cable type),
fasteners, epoxy painting, etc. tested for overload as per IS and as per specifications,
complete in all respect.
Capacity: min. 1.0 Ton. (For Subm. NC Pump set)
Lift: min. 10-12 m or as per site req.
Bay Length: min. 5-8 m or as per site req.
(w/o MONORAIL GIRDER & MS supporting structure)
11 Item Description as per 6.1.1 and of following size complete, 1 No. 2,28,220
Capacity: min. 1.0 Ton. (For Manual Screen)
Lift: min. 10-12 m or as per site req.
Bay Length: min. 5-8 m or as per site req.
12 SLUICE GATE 1 No. 2,70,060
SITC of Manually gear operated C.I. Thimble mounted Sluice Gate conforming to AWWA
C 501 or IS: 13349 - 1992 Class - 1 with rising spindle, single faced, wall thimble mounted,
handwheel, Conventional Type Closure, flange back frame, headstock, Spindle with
supports brackets having length as specified or to suit site condition, suitable for seating
as well as unseating water head, complete in all respect.
Size: 400 mm X 400 mm - approx. 4.6 m spindle length (At Inlet Pipe)
13 SITC of Box Type Manual mesh Screen having following size, made of SS 304 material 1 set 2,47,240
having round bars of size min. 9.0 mm dia with clear bar opening as specified here below,
suitably welded in outer frame of equal Leg SS angle of size 50 mm x 50 mm x 6 mm thick
or higher, with intermediate support at required locations, complete as per specs. & shall
also including followings:
The screen shall be with SS perforated Screening Material Collection Box at bottom end
of Screen having size as specified, fabricated from 3 mm thk SS sheet, screen shall be
suitable to slide complete screen through rollers between existing guide passage of MCP
400, embedded/ fixed in wall on both sides of RCC wall up to top of chamber with all
necessary hardware, SS nuts, bolts & wahsers, sacrificial Brass lugs on sides, min. two
lifting lugs/hooks & SS lifting chain having intermediate link/chain of 100 mm dia. at every
1.5 m distance with shackle, etc. complete in all respects and provided with 1 set of
cleaning rake with each screen, complete as per specification and complete in all respect.
Screen Size: 550 mm (W-or actual chamber width as per site) x 600 mm (H) x 300 mm (D)
Box Size: 550 mm (W-or actual screen width) x 100 mm (H) x 300 mm (D)
Opening: 50 mm x 50 mm sq. opening
Note : 1. Screen suitable for 600 mm wide screen chamber or to suit site requirement.
(w/o Guide channel & MS supporting structure)
14 Providing, Supply of Structure Steel at site of work with freight, loading, unloading 1000 kg. 64.84
carting, etc. including all taxes and duties complete such as joints, channels, angles, Iron
Rails, ISA/ISMC/ISMB/MS flat, Plates, Chequered plates (below 8mm thickness) for cable
trench etc. required for support structure of all Electro-mechanical equipment, piping, etc.
for support on floor / wall / beam / brackets etc. as per tender and IS.
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
15 Labour Charges for lowering, laying, Fixing with fabrication various size section of MS such 1000 kg. 13.07
as joints, channels, angles, Iron Rails, ISA/ISMC/ISMB/MS flat, Plates, Chequered plates,
for cable trench etc Complete with two coats of red oxide and two coats of approved
colour shade of epoxy paint as per relevant IS and as per specification.
TOTAL OF MECHANICAL WORK WITHOUT GST
16 ELECTRICAL WORK 1 Set 38,952.11
TPN MCCB (For LT Service Obtaining Requirement)
SITC of 250A TPN microprocessor MCCB, LSIG (50kA) with inbuilt O/L, S/C & E/F
protection with Extended rotary handle, Terminal spreader, Auxiliary change over & Trip
contact, with Outdoor Enclosure with canopy 2mm thick , Single/double door & Wall
mounted/ stand mounted as per site requirement (with incoming & outgoing cable entry
at bottom )with Cable end boxes with RYB indicating lamp, Digital voltmeter, VSS,ON,OFF
& Trip indicating lamp etc as per Power supply company requirements & location.
Including all civil works for fixing of panel on wall.
(Wall mounted at Location as per PSC req.)
17 MEDIUM VOLTAGE PANEL BOARD (PMCC /APFC) 1 Set 4,91,000.00
SITC of PMCC Panel (50kA), compartmentalized, floor mounted, operating height
maximum 1800/1900 mm, Extensible on both ends, suitable for Manual & Auto operation -
Local & through PLC/SCADA operation as per site conditions complete in all respects as
per Tender SLD / Specification / IS and including following as minimum:
(1) One no. Incoming feeder FP 250A Microprocessor MCCB (50kA), LSIG, with inbuilt
O/C, S/C, & E/F protection for I/c with Digital Voltmeter, Voltmeter selector switch,
Digital Ammeter, Ammeter selector switch, Power Factor Meter, MFM with RS-485 of
Class-0.5, Indicating lamps R,Y,B,On,off,Trip, 3nos. 250A/5A, Cl.-0.5 metering CT, CL 0.5 CT
for APFC relay etc. Constant voltage/control voltage transformer 1500VA, 415V/230V AC,
with tapping +/-5% in steps of 2.5%, 32A DP MCB complete in all respects.
(2) 250A TPN Main Aluminium busbars. (main busbars size with current density
(3) 18.5 KW STAR -DELTA STARTER FEEDER (SUBM.): 2 NOS
18.5 KW or higher as per pump manufacturer recommendation Star-delta starter with 80A
TPN Thermal magnetic MCCB with Adjustable O/L & Adjustable S/C protection, 80A AC3
duty contactors (3 nos.), O/L Relay, star-delta timer, Ammeter with ASS, Resin Cast CT Cl:
0.5(3 nos.),SPP, PMU, A/M, L/R switch, ON, OFF, TRIP Indication & Start, E-Stop & Reset
pushbutton etc. for S/D starter. complete in all respects.
(4) 63A TPN TM MCCB FEEDER : 1 No. (for Spare)
Each feeder comprising of 63A TPN Thermal Magnetic (TM) MCCB, with indicating lamp
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
17 (5) 32A TPN TM MCCB FEEDER : 4 Nos. (1 no. EOT with ECH at PH, 1 no. EOT with ECH at rate incl in
screen, 2 nos. spare) above price
Each feeder comprising of 32A TPN Thermal Magnetic (TM) MCCB, with indicating lamp
(6) 63A TPN TM MCCB FEEDER FOR ALL MCB FEEDERS: 1 set:
Incomer: 63A TPN Thermal Magnetic (TM) MCCB, with indicating lamp etc.
a) 3 nos. 32A 'C' curve 4P MCB feeders (for 1 no. Ind LDB, 1 no. ICP/PLC panel & 1 no.
B) 1 no. 32A 'C' curve 4P MCB with Time switch,32A contactor 4P,ON lamp feeders (for
(7) APFC separate cubical compartment (minimum 20 KVAr) having 1 no. 63A TPN
Thermal magnetic MCCB 50KA with adjustable overload and adjustable short circuit, 8step
APFC relay with RS 485, 1 no. 63 A/5A, Cl.-1.0 CT for Ammeter, Digital Ammeter, ASS,
no. 1 kVAR capacitor with 16A TPN D curve MCB, 2 nos. 2 kVAR capacitor with 16A TPN D
curve MCB, 3 nos. 5 kVAR capacitor with 16A TPN D curve MCB with capacitor Duty
Contractor, A/M switch, On delay timer, Push Buttons etc. Complete in all respects as per
Specification, IS & SLD.
(8) Multiplication relay as required for dry run protection of pumps.
NOTE: 1). All MCCB shall be 50KA, Ics = 100% Icu, inbuilt protection with adj O/L and
Adj.S/c (LSIG for MP MCCB),Extended rotary handle, Terminal spreader, Auxiliary Change
over contact and trip contact as required.2) All MFM, ACB, Soft Starter,Temp.Scanner etc
shall be with inbuilt RS
18 SITC of Lighting Distribution Board (LDB) as under: 2 Nos. 7,497.69
SITC of 3 Phase 4 Wire 4P, double door Prewired LDB each for Indoor Lighting & Outdoor
Lighting Suitable to house :
Incoming: 32A FP, ELMCB (30mA)
Outgoing: 20A SP MCB (9 nos.) & 16A SP MCB (9 nos.)
19 SITC of LCS pushbutton station ON & OFF (E-stop) set complete with Enclosure, 2 Nos. 2,008.47
necessary mounting/ fixing arrangement on wall / pipe support etc. to be installed near
motors for remote operation, etc. as per IS and specifications. (including structural steel)
20 SITC of stand / wall mounting type MS Junction Box, minimum 2.5mm thick, with 2 Nos. 1,906.78
detachable cable gland plate of 3mm thick, duly powder coated, with earthing terminals,
steel structure stand for mounting of JB, etc. for Jointing/Termination suitable for 1.1 kV
Submersible Flexible Copper Power cable with Aluminium/ Copper armoured power cable
from PMCC . Scope shall include providing suitable rating AL busbars, Support insulators,
Crimping type lugs,nuts,bolts,washers etc. complete in all respects as instructed by E.I.C.
Drawing shall be got approved before SITC of the same. Lugs of cables shall not be
connected directly. (Structure steel for Stand shall be measured separately)
JB of minimum Size: 300mm x 300mm x 100mm or higher as required. or higher as
required (for Pump)
21 LOW VOLTAGE (LT) CABLES 25 Mtr. 783.00
Supply, laying, testing and commissioning of 1.1 kV, A2XFY(X)/2XWY(X) XLPE insulated (IS
7098) AL / Cu stranded conductor, Extruded innersheath cables as per specification & IS.
The cable when laid outside the building shall be laid underground in trench with brick &
sand protection/in DWC pipes as per specified method and shall be laid in prepared
trench/ on cable tray when laid inside the building.
SITC of 3.5C x 240 sq. mm. A2XFY(X) Cable (1 run for MCCB to PMCC panel)
22 3C x 6 sq. mm. A2XFY Cable (2 runs for PMCC to 2 nos. 18.5 kW Subm. pump Junction box) 110 Mtr. 70.00
23 4C x 6 sq. mm. A2XFY(X) Cable (For 1 no. Indoor LDB, Outdoor LDB & for 5 nos. street 170 Mtr. 78.00
24 4C x 2.5 sq. mm. 2XWY/2XFY(X) Cable (For 1 no. TPN MCB for EOT with ECH at Pump 130 Mtr. 81.00
House,1 no. ECH at Screen, 1 no. ICP/PLC panel, 2 nos. pump PMU)
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
25 5C x 1.5 sq. mm. 2XWY(X) Cable (For 2 nos. of pump LCS) 60 Mtr. 130.00
26 2C x 2.5 sq. mm. Multi strand 2XWY(X) Cable (APFC sensing C.T) 20 Mtr. 177.12
27 Single core 95sq. mm. PVC insulated circular unsheathed copper conductor flexible Cable 20 Mtr 910.12
(For Power supply Metering Panel to I/c MCCB Unit)
28 CABLE END TERMINATION AND CONNECTION: 2 Nos. 838.00
SITC of Double compression Ni-Plated brass cable glands and crimping type Bimetallic
lugs / sockets with necessary tools and equipments as specified in specifications and IS.
The glands and lugs / sockets shall be suitable for cable size and type mentioned below &
as per specifications.
1) Earthing the glands and armouring with earthing clamp and jumper and also connecting
to common earth bar.
2) The job also includes, if necessary, supply & fixing of extension busbar of same material
on MCCB or panel board terminal / connector to connect more than one no. of parallel
cables or to connect higher size cable to lower size unit. The job also includes earthing the
glands and armour of the cable with common earth bar or flexible copper mesh.(Cable
termination qty. shall be as per site requirement)
3.5C x 240 sq. mm. A2XFY(X) Cable (1 run for MCCB to PMCC panel)
29 3C x 6 sq. mm. A2XFY Cable (2 runs for PMCC to 2 nos. 18.5 kW Subm. pump Junction box) 8 Nos. 110.00
30 4C x 6 sq. mm. A2XFY(X) Cable (For 1 no. Indoor LDB, Outdoor LDB & for 5 nos. street 14 Nos. 111.00
31 4C x 2.5 sq. mm. 2XWY/2XFY(X) Cable (For 1 no. EOT with ECH at Pump House,1 no. EOT 10 Nos. 65.15
with ECH at Screen, 1 no. ICP/PLC panel, 2 nos. pump PMU)
32 5C x 1.5 sq. mm. 2XWY(X) Cable (For 2 nos. of pump LCS) 4 Nos. 130.00
33 2C x 2.5 sq. mm. Multi strand 2XWY(X) Cable (APFC sensing C.T) 2 Nos. 49.13
34 Single core 95sq. mm. PVC insulated circular unsheathed copper conductor flexible Cable 10 Nos. 47.11
(For Power supply Metering Panel to I/c MCCB Unit)
35 CABLE TRAY 30 Mtr. 388.00
SITC of G.I. (hot dip galvanised )Ladder type medium duty (2mm thick) Cable Tray with
necessary bends, tees, reducers, covers and clamps for fixing. All material shall be Hot dip
galvanised as per Specification. And including all accessories.
300 x 75 mm - Ladder type
36 150 x 50 mm - Ladder type 100 Mtr. 336.00
37 Supply, laying and erection of 75 mm ID approved make Double Walled Corrugated pipes 50 Mtr. 161.15
(DWC) of polyethelene (confirming to IS-14930 II) with necessary connecting accessoies of
same material at required depth for laying of cable below ground / road surface for
enclosing cable and back filling the same to make ground as per original. (LT cable etc)
38 Cable Trench, Laying & Installation of Cable: Making cable trench in soft soil of suitable 100 Mtr. 46.46
width of 90cms deep for laying cable, Sand cushioning and brick protection on sides and
on top all over the run and back filling the same and making the surface as normal
ground as per IS & Specification. (For laying of LT cable in ground)
39 Cable Protection/ Covering in Trench: Cable Covering with second class bricks or cement 50 Mtr. 133.31
tiles laid cover the cable (top) & also on both side with sand bedding/cusioning of
75mm.& covering of 150mm Layer of sand above cable (16 bricks per meter.) as per IS &
Tender Drg/ Specification. (For HT/LT cable protection) complete in all respects as
instructed by EIC.
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
40 CHEMICAL EARTHING SYSTEM 2 Set 10,494.73
SITC of Maintenance free chemical earthing (copper) with earthpit of minimum bore size
dia. 225mm Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS-
3043:1987 /Tech spec. made of corrosion free Pipes having Outer pipe dia of 48 mm
having 250 Micron copper plating, Inner corrosion free Hot dip galvanised (80 to
micron) pipe dia of 26 mm with copper flat strip type connection terminal 14mm dia
with constant ohmic value surrounded by highly conductive corrosion resistant chemical
compound with high charge dissipation suitable for electrical installation & of 3Mtr.
length of Pipe with two nos. 25Kg. bag of Back filling compound.. (2 nos. for ICP earthing)
NOTE: Earthing Resistance value & date shall be painted on the chamber cover.
41 SITC of Maintenance free chemical earthing with earthpit of minimum bore size dia. 4 Set 7,028.82
225mm Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS-3043:1987
/Tech spec. made of corrosion free Hot dip Galvanised (min 150 Microns) Pipes having
Outer pipe dia of 76 mm , Inner corrosion free Hot dip galvanised (80 to 100 micron) pipe
dia of 26 mm with copper flat strip type connection terminal 14mm dia with constant
ohmic value surrounded by highly conductive corrosion resistant chemical compound with
high charge dissipation suitable for electrical installation & 3Mtr. length of Pipe with two
nos. 25Kg. bag of Back filling compound. (2 nos. for PMCC panel & all elect. Equipments)
NOTE: Earthing Resistance value & date shall be painted on the chamber cover.
42 SITC of 50mm(w) x 8mm(T) etc. sizes as required, HOT dip galvanized GI Strip including 230 Kg. 77.17
supply & fixing using GI spacers, saddles when laid inside the building and inclusive of
excavation & refilling of earth when laid outside the building & interconnection with earth
pit & all electro-mechanical equipments.
(50X6 G.I Strip wt.2.3 kg/m, 2.3x100Mt.=230kg.)
43 Supply, laying and erection of 25mm(w) x 3mm(T) etc. sizes Copper Strip including supply 15 Kg. 787.34
& fixing of bolts, saddles when laid inside the building and inclusive of excavation &
refilling of earth when laid outside the building & interconnection with earth pit & PLC
panel. (25 X3 Cu. Strip, 0.761 Kg/m, 0.761 x 20mtr.=15.22Kg.)
Copper Bolt,Nuts ,Washers shall be used for Connecting Earth electrode to individual eqp.
Bitumen shall be used at the place of joint/welding. (PLC panel to Earthing)
44 Supply, laying and erection of 25mm(w) x 3mm(T) etc. sizes as required, HOT dip 18 Kg. 77.17
galvanized GI Strip including supply & fixing using GI spacers, saddles when laid inside the
building and inclusive of excavation & refilling of earth when laid outside the building &
interconnection with earth pit & all electro-mechanical equipments. (25X3 G.I Strip,
45 SITC of HOT Dip Galvanized iron strip wire 8 SWG (For LDB,LCS, etc.) 19 Kg. 77.17
(8 SWG G.I Strip, 0.103 Kg/m, 0.103 x 180Mt.=18.54 Kg.)
46 INTERNAL WIRING 100 Mtr. 78.06
SITC of Mains & outlet points wiring with 1.1 kV grade FRLS PVC insulated ISI marked
flexible stranded copper conductor wires with medium class min. 25mm. dia. Electrical
grade PVC pipe and accessories to be erected concealed in / to be run on surface / wall /
ceiling with following sizes as mentioned below. The unit rate wirings shall be with
connector, PVC junction box, wires, holder, ceiling rose, angle holder, switch, sockets,
switch board, brass chromium / cadmium plated machine screws, phase and neutral
wires, green Earth continuity wires etc. as required to complete wiring from LDB panel to
the final outlet termination points. The wiring shall be as per IS:732, IS:4648 and as per
tender specification / IS.
(a) SITC of Mains wiring with 3 wire 1.5 sq.mm.
47 Same as per above, but (b) SITC of Mains wiring with 3 wire 2.5 sq.mm as per tender 100 Mtr. 96.06
specification & IS.
48 Same as per above, but (c) SITC of Mains wiring with 4 wire 1.5 sq.mm as per tender 60 Mtr. 86.06
specification & IS.
49 Same as per above, but (d) SITC of Mains wiring with 4 wire 2.5 sq.mm as per tender 60 Mtr. 119.06
specification & IS.
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
50 SITC of Point wiring for Light / fan / Bell / Primary Point with 2nos. 1.5 sq. mm & earth 21 Nos. 326.59
wire of 1.5 sq. mm (green) both are of ISI marked 1.1 kv grade FRLS PVC insulated
multistrand copper wires , pipe to be erected concealed in flushed on wall / ceiling,
complete with 6A Tissino Type ISI marked flush type switch / bell push & accessories
erected on metal / PVC Box covered with 3 mm thick PC (Polycarbonate) / Acrylic sheet
with necessary lamp holder / ceiling Rose / H. D. connector as directed with medium class
Rigid PVC pipe & accessories.
51 SITC of 6A independent Plug with 2nos. 1.5 sq.mm Cu. Mains size wiring & earthwire of 2 Nos. 288.50
1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand
copper wires with medium class Rigid PVC pipe and accessories to be erected on wall /
ceiling, complete with ISI marked 3 / 5 Pin socket and tissino type switch erected with
earth continuity connection erected on Metal / PVC box covered with 3 mm thick
PC(Polycarbonet) / Acrylic sheet.
52 SITC of 6/16A independent Plug with 2nos. 4 sq.mm Cu. Mains size wiring & earthwire of 2 Nos. 565.50
1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand
copper wires with medium class Rigid PVC pipe and accessories to be erected on wall /
ceiling, complete with ISI marked 3 / 5 Pin socket and tissino type switch erected with
earth continuity connection erected on Metal / PVC box covered with 3 mm thick
PC(Polycarbonet) / Acrylic sheet. (1 no. LT Room, 1 no. Pump House)
53 SITC of One 300/380 mm dia. Ex fan 16A independent Plug point near Ex. Fan with 2nos. 4 4 Nos. 601.60
sq.mm Cu. Mains size wiring & earthwire of 1.5 sq.mm (green) both are of ISI marked
KV grade FRLS PVC insulated multistrand copper wires with medium class Rigid PVC pipe
and accessories to be erected on wall / ceiling, complete with ISI marked 3Pin socket and
tissino type switch erected with earth continuity connection erected on Metal / PVC box
covered with 3 mm thick PC(Polycarbonet) / Acrylic sheet. Plug point shall be near Ex.Fan.
(2 nos. LT room, 2 nos. P.H)
54 SITC of 380mm sweep 1400 R.P.M exhaust fan, capacitor type, having double ball bearing, 4 Nos. 3,052.47
M.S.blades, mounting frame, forearms, suitable to operate on 230V,50 HZ AC supply
conforming to IS: 2312.Fan shall be painted with epoxy grey colour controlled by one 6 A
flush type switch on board and 6A plug point near Ex. fan. (2 nos. LT room, 2 nos. P.H)
55 SITC of Single Phase 20A 3 Pin Metal clad Industrial Type Socket with plug top and 20A 2 Nos. 840.00
SPMCB, suitable for flush mounting, in 16 SWG MS box of suitable size and covered with
mm thick electrical grade hylam sheet or equivalent ISI marked Electrical grade Bakelite
sheet and earthing with 2.5 sq.mm insulated copper wire run inside the conduit including
interconnections etc. complete as required.
(1 no. LT Room, 1 no. Pump House)
56 SITC of Sheets steel powder coated weather proof enclosure with One no. 32A, 415V 4P 4 Nos. 765.39
MCB for Motor & Inductive load (C Curve) having 10 KA breaking capacity & confirms to
IS: 8828. (1 no. WR DB TPN MCB at P.H, 1 no.WR-DB TPN MCB at screen, 1 no. for EOT
with ECH at P.H.,1 no. ECH for Screen)
57 1200mm sweep ceiling fan, capacitor type, having double ball bearing 450mm down rod, 2 Set 1,581.51
canopies, shackle, rubber bush, blades, electronic speed regulator, suitable to operate on
230V,50Hz AC supply conforming to IS: 374/1979.Fan shall be painted with white
colour.(1 no. LT Room, 1 no. at P.H)
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
58 LED LIGHT FIXTURES & LIGHTING: 10 Nos. 293.26
SITC of Indoor wall mounting 20Watt or up to 25% higher wattage LED 4 feet Tube Light
indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA polyester powder coated and high U.V. & corrosion resistance with diffuser
and/or Polycarbonate optics with company mark/name
120 to 300 V,Power Factor more than 0.9, THD < 20 %,
CCT 4000 K to 6500K, Uniformity ratio >0.7,
Luminaries efficacy> 85 lumens/watt
LED driver efficiency > 85 %
(Each fitting required LM-79 & LM-80 Certificates)
Tube Light with integral / non-integral driver, Surge-4KV,IP-20, 4 feet, Cat-III (For 4 nos. at
LT Room, 6 nos. at P.H.)
59 Item description as per Sr. No.7.1 SITC of 7 watts LED Lamps integral type,cool white with 2 Nos. 111.00
PC diffuser suitable for B22 LAMP holder (1 no. LT Room, 1 no. at P.H)
60 SITC of 40W LED Surface / Wall mounted LED Flood Light fittings with High power White 4 Nos. 5,144.28
LEDs wattage of 1Watt and above assembled on single MCPCB, efficiency more than
lm/w and corrosion free High pressure die cast aluminum housing with smooth finish
powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/
lenses with company mark/name engraved or embossed
120 to 300 V,Power Factor more than 0.95, THD < 20 %, CCT 5000 K to 5700K,
Uniformity ratio >0.45, Luminaries efficacy> 85 lumens/watt . LED driver efficiency > 85 %.
( Each fittings required LM-79 & LM-80 certificates)
(IP-65), Surge -4KV Cat-III
For Indoor use: (at Pump House)
61 SITC of 'B' class galvanised iron pipe 32 mm outside dia 45 cms long duly welded on 20 9 Nos. 553.11
cms x 20 cms x 3 mm thick M.S. base plate, erected on wall or corner for mounting
luminaries with necessary hardware materials duly painted for wall mounting indoor
flood light fixtures on Wall of Buildings & post top lantern.
62 EXTERNAL LIGHTING (Flood LIGHT): 5 Nos. 6,029.70
SITC of 70W LED Wall mounted LED Flood Light fittings with High power White LEDs
wattage of 1Watt and above assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses
with company mark/name engraved or embossed
120 to 300 V,Power Factor more than 0.95, THD < 20 %, CCT 5000 K to 5700K,
Uniformity ratio >0.45, Luminaries efficacy> 85 lumens/watt . LED driver efficiency > 85 %.
( Each fittings required LM-79 & LM-80 certificates)
(IP-65), Surge -4KV Cat-III
For Outdoor use: (5 nos. for area lighting)
63 SITC of 40watt, Cat-III Post Top Lantern LED fitting comprises of 650 MM TOP Diameter, 2 Nos. 4,772.85
120 degree beam angle with 3 Nos. Supporting Ribs and with 0.5mt. G.I. fitting pipe (for
64 EXTERNAL LIGHTING (STREET LIGHT): 5 Nos. 10618.72
SITC of Street Light Pole, steel tubular swaged type, 7.5 meter long with single arm &
M.S.base plate with pipe cap and over hung 1.5 m long having dia to suit the socket of
240V LED street light fixtures. Street light pole unit rate shall be with (i) IP 65 SMC box of
size 20 x 15 x 15 cms. with MCB & terminal strip inside the box with hinged/sliding door
(ii) 50mm dia, B class GI pipe bracket min.1.5mtr long for Incoming & outgoing cable
(iii)MS Cable Clamp of 25 x 3mm (iv)SITC of 1.5 Mtr.single Arm bracket of medium duty
MS pipe of 4.2 cms. Out side dia complete with suitable sleeve tubing 45 cms. long of
required size of pole top etc. and having spread of 1.5.mtr. length with 110 deg.(v)
Complete painted with one coat of Red oxide / PU base primer and two coats of
Aluminium / PU paint for Pole,Arm, pipe etc.
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
65 SITC of 70W LED Street light fittings with High power White LEDs wattage of 1Watt and 5 Nos. 5,918.70
above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free
High pressure die cast aluminum housing with smooth finish powder coated and heat sink
extruded aluminium with diffuser and Polycarbonate optics/ lenses with company
mark/name engraved or embossed
120 to 300 V,Power Factor more than 0.95, THD < 20 %, CCT 5000 K to 5700K,
Uniformity ratio >0.45, Luminaries efficacy> 85 lumens/watt . LED driver efficiency > 85 %.
( Each fittings required LM-79 & LM-80 certificates)
Street Light (IP-65), Surge -4KV, 70 watt Cat-III
66 SITC of M-20 / 1:2:4 cement concrete foundation for Street light pole & 70 % PCC from 5 Nos. 1,282.12
bottom including excavation for the pole of size 60 x 60 x 120 cms. Deep in below ground
level with plinth of 45 cms x 45 cms(or 45 cms dia x 45 cms) high upper ground level with
necessary curing and finishing in approved manner.
67 SAFETY ACCESSORIES 1 No. 8,586.26
SITC of following safety accessories complete with necessary fixing brackets, other
accessories and tools etc. as required to complete the job.
Supply & Erecting carbon dioxide (CO2) fire extinguisher of 6.5kg capacity with necessary
clamps made from 50 x 6 mm M.S. Flat with nut & bolts grouted in wall complete.
(For 1 no. for LT Room)
68 Supplying of standard first AID box with antiseptic cream, medicine for use on wounds 1 No. 297.00
due burn, crepe bandage, guage bandage, medicated ready to use bandage (Band-aid)
adhesive tape for medicinal user, scissors, antiseptic solution (Savlon or similar) etc. (All
above contents shall be of standard makes)
(For 1 no. For LT Room)
69 Supply & fixing of printed instruction (First Aid) Chart both in English and Gujarati and duly 1 No. 129.06
framed with front glasses, for treatment of person suffering from electric shock. (For 1 no.
70 Supply and fixing of 20 W fluorescent lamp operated emergency light with maintenance 1 No. 2,730.00
free battery for 3 hours operation during mains power failure.
(For 1 no. LT Room)
71 Supply and laying of Synthetic Insulating Mat of Class - A of min. thickness 2mm as per 3 Sq.mtr. 1,017.00
IS:15652 and with good electrical insulation property for 1.1KV/3.3KV as per site
requirement. (For LT Panel)
72 Providing pair of rubber hand gloves ISI make suitable for working on 22 KV supply 1 No. 212.00
TOTAL OF ELECTRICAL WORKS WITHOUT GST
73 PRESSURE MEASURING SYSTEM 2 Nos. 5,522.00
Supply, installation, testing & commissioning of Diaphragm Type pressure guage having
150 mm dial with necessary fittings/accessories in SS
(manifold valve, nipples etc.) complete in all respects and as per specs.
Range : 0-1.6 Kg/cm2 (at each pump discharge line)
74 LEVEL MEASURING SYSTEM FOR SUMP 1 No. 59,436
Supply, installation, testing and commissioning of Ultrasonic type Level Transmitter with
remote type transmitter with 10meter cable between Sensor and Transmitter along with
all required accessories, Weather proof enclosure for transmitter for outdoor application,
mounting stand , etc. complete in all respects as per specification and having following
measurement ranges for liquid (Sewage) application:
Meas. Range: upto 10 m (at sump )
75 Supply, installation, testing and commissioning of Float type Level Switch along with 10 2 Nos. 12,802
mtr. Cable and WP Junction Box (at sump for dry run protection of pumps through relay
multiplication in PLC, U/S at Manual Screen for High Level alarm), etc., complete in all
respects and as per specification.
Meas. Range: upto 10 m (at sump )
Sr. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
76 ELECTRO MAGNETIC FLOWMETER MAINS OPERATED Supply, 1 No. 1,06,049
installation, testing and commissioning of Full Bore Electromagnetic flow meter
comprising of IP-68 Sensor , IP-66 remote type transmitter with 20 m cable between
sensor and transmitter along with all mounting accessories, Weather proof enclosure for
transmitter, hardware, mounting stand, etc.
as per specification and to complete the work in all respect as per site condition necessary
connection with pipe and shall have following size.
Meter Size: 200 mm NB (At Pump common Header )
Pipe Size : 200 mm NB
77 PLC BASED CONTROL PANEL FOR WDS 1 LOT 6,09,848
Supply, Installation, Testing & Commissioning of PLC Based Instrument control Panel with
panel mounted 10 " colour touch screen HMI, 4G or Latest GPRS modem (Ethernet port +
SIM Slot, ) with 2 IP Supported, Communication port for MFM. Instrument Control Panel
'(PLC Enclosure / Panel ) with necessary PLC based logic and wiring , 1 no. Panel Mounted
FIQ for flow meter and 1 no. Process Indicator for Level Ta., Min. 1 kVA Online UPS + CVT
(with 60 min min backup alongwith filter for harmonic, suitable rating SMF inbuilt
batteries alongwith battery charger and all other accessories as per standard), etc.
complete in all respects and as per specs with PLC having minimum I/O count of 20DI /
DO / 4AI /2AO. These are the minimum IO requirement if any other IO,s required to
complete the work contractor shall be provide the same without any extra cost.
78 INSTRUMENT CABLE & ACCESSORIES 50 MTR. 146
'Supply, Laying, Installation, Connection, Termination, Testing & Commissioning of
Instrument Cables as per specs.
The unit rate shall include
a)Supply, loading & unloading of the cable at site from store.
b)Shifitng of cable from site store to place of installation.
c)Fixing of cable clamps, brackets, supports, route markers etc. where ever required to fix
the cables safely.
d)Excavation, back filling and levelling of ground alongwith laying of fine sand, protection
bricks and other necessary civil material for laying cables outside the building.
f)Testing and submission of sketches & reports of all the cables laid.
79 CONTROL CABLE 100 MTR. 330
80 SIGNAL CABLE 100 MTR. 133
81 CABLE END TERMINATION AND CONNECTION : 4 Nos. 160
'Supply, fixing, connection, testing and commissioning of double compression brass cable
glands and crimping type Bimetalic lugs / sockets with necessary tools and equipments as
specified in specifications and IS complete in all respects. The glands and lugs / sockets
shall be suitable for cable size and type mentioned above. The job also includes earthing
the glands and armour of the cable with common earth bar or flexible copper mesh as
82 CONTROL CABLE 8 NOS. 230
83 SIGNAL CABLE 8 Nos. 160
TOTAL OF INSTRUMENTATION WORK WITHOUT GST
Providing and Laying of Rising Main
Sr. Description Total Unit Rate Amount
No. Qty. in Rs. in Rs.
1 Excavation for pipeline tenches for sewerage line, manhole 4,468.00 Cum 102.35
with shoring & shruting if required as per required gradient
and line including all safety provision using site rails and
stacking excavated stuff including up to all required lead
cleaning the site etc. complete for all lift and strata as
In all sorts of Soil and soft murrum.
Upto 1.50 mt depth
1.1 1.50 mt to 3.00 mt depth 216.00 Cum 112.70
2 Excavation in bituminous road as per reuired gradient and 598.20 Cum 288.65
line including safety provisions using site rails and stacking
excavated stuff including up to all required lead cleaning the
site etc. complete for all lifts as specified.
Excavation in Bituminous Road
3 Providing and supplying D. I. K-9 grade pipes for following 50.00 Rmt 2,998.00
nominal bore diameter with internal cement mortar lining
including all taxes, insurance,transportation, freight charges,
octroi,inspection charges, loading, unloading, conveyance to
departmental stores, stacking etc.complete. (IS 8329-2000).
For sewerage project cement mortor lining shall be with
sulphate resistance cement.
4 Lowering, laying and jointing C. I. S & S Spun pipes suitable 50.00 Rmt 146.05
for Tyton joints / Mortar lined D. I. Pipes of various classes
with CI / MS specials of following diameters in proper
position, grade and alignment as directed by Engineer-in-
charge including hydraulic testing etc. comp.
Sr. Description Total Unit Rate Amount
No. Qty. in Rs. in Rs.
5 Manufacture, Supply & Delivery of Ductile Iron Flange 3.00 kg 148.00
socket spigot bends, tees, reducers or any other specials as
per BS-EN-545/1995 Class-A series K12 suitable for use with
D.I. Pipes manufactured as per IS:8329/1994delivery of
specials is to be made to store or site of works any where in
Gujarat including all taxes, loading, unloading, carting,
stacking, insurance, inspection charges, octroi etc.
complete. With external bitumen & zinc coating & internal
cement mortar lining.
Socket & Spigot Type
80 to 300 mm Dia
6 Providing and casting in situ C.C. in grade M-20 (proportions 13.00 Cum 6,348.00
as per mix design or as per table9 of IS456 2000 in masses
by weigh batching ) using granite, quartzite trap metal of
size 6 mm to 20 mm for RCC work, including scaffolding
centering, formwork, needle vibrated consolidation, curing
complete up to 6 meter depth or height (excluding cost of
reinforcement and neat finishing) with centering and
shuttering/deshuttering etc. complete for structure other
than water retaining (Below G.L)
Footing for column or foundation (with form work)
(For Thrust block & Encasing)
6.1 Supplying cutting, bending, binding and placing in position 1.00 MT 89,129.60
steel as per plan and design and as per ISS 2502 including
cost of steel and binding wire for reservoirs/structures only
including lift below G.L. for all diameters
Do - deformed (TMT) bars confirming to relevant IS Fe -
500 grade for all diameters.
7 Refilling with available excavated earth including ramming, 4,438.00 Cum 25.30
watering, consolidating disposal of surplus stuff as directed
within a radium of 3 Km. Refilling as directed
8 Providing and supplying ISI mark CI D/F Sluice Valves as per 1.00 No. 20,384.00
IS:14846 (Latest Edition) of following class and diameter
including all taxes, insurance, transportation, freight
charges, octroi, inspection charges, loading, unloading,
conveyance to departmental stores, stacking etc. complete.
PN-1 With hand wheel /cap operated (PD type short body)
Sr. Description Total Unit Rate Amount
No. Qty. in Rs. in Rs.
9 Lowering, laying and jointing in position following C. I. / D/F 1.00 No. 1,312.15
Reflux valves, Butterfly valves, Sluice valves and Air valves
including cost of all labour, jointing material, including nut
bolts and giving satisfactory hydraulic testing, etc. complete.
10 Providing and supplying C. I. Temper proof Air valves with SS 3.00 No. 13,789.00
304 Float gun metal- nozzle of approved make & quality of
following class and diameter including all taxes, insurance,
transportation, freight charges, octroi, inspection charges,
loading, unloading, conveyance to departmental stores,
stacking etc. complete.
With Isolating Sluice Valve PN
11 Lowering, laying and jointing in position following C. I. / D/F 3.00 No. 472.65
Reflux valves, Butterfly valves, Sluice valves and Air valves
including cost of all labour, jointing material, including nut
bolts and giving satisfactory hydraulic testing, etc. complete.
Air valves double ball Flanged 80 mm Dia.
12 Providing, laying, spreading and compacting graded stone 499.00 3 1,126.95
aggregate to wet mix macadam specification including
premixing the Material with water at OMC in mechanical
mix plant carriage of mixed Material by tipper to site, laying
in uniform layers with grader in sub- base / base course on
well prepared surface and compacting with vibratory roller
to achieve the desired density as per MoRTH Clause
13 Construction of valves chambers in brick or bela stone 5.00 No. 13,053.65
masonry, locally available in C. M. 1:6. Foundation concrete
150 mm thick in C. C. 1:4:8 of trap metal size 25 mm to
mm thick, inside cement plaster in C. M. 1:3 and cement
pointing outside in C. M. 1:3 and top cover of precast RCC
slab 100 mm thick (with key hole in two parts, each with
handles or MS Bar etc. complete as given size) Upto 1 Mt.
depth from G. L. to pipe invert level incl. complete civil
works but excl. cost of excavation and refilling, with cast in
situ RCC slab in one single piece with fixing of CI-MH Frame
and cover (excl. cost of CI-MH Frame and cover) with 23 mm
thick brick masonry wall in C.M.1:6.
Size of 1.30 m x 1.30 m and 1.0 m deep
13.1 For 1 Mtr. Extra Depth 3.00 Rmt 6,996.60
Sr. Description Total Unit Rate Amount
No. Qty. in Rs. in Rs.
14 Drilling of 900mm dia Horizontal borehole for watermain 30.00 Rmt 19,992.32
pipeline crossing under the road incl in all strata with
requried length incl fixing of 800mm dia M.S/RCC casing
pipe with pushing etc complete various size of pipe for
406.4 to 508mm dia
Without Water main & with RCC Casing Pipe watermain
Construction of Inspection Chambers
Sr. Description Total Unit Rate Amount
No. Qty. in Rs. in Rs.
1 Providing and supplying of Class SN8 Structured Wall polyethelene Piping systems (Pipe with 5,980.00 Rmt 208.00
online/offline coupler and elastomeric sealing ring) with non-smooth External Annular
Corrugated and Smooth Internal Surfaces (Double Wall) for non-pressure underground
Sewerage & Drainage application as per EN:13476-3 including all local and central taxes,
transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to
the departmental stores etc. complete.(ID Dia) 100 mm Dia
2 Excavation for pipeline trenches for sewerage line, manhole etc. all with shoring and strutting if 5,104.81 Cum. 102.35
required as per required gradient and line including safety provisions using site rails and
stacking excavated stuff including up to all required lead Cleaning the site etc. complete for lifts
and strata as specified.
In all sorts of soil and soft murrum
3 Providing and laying cement concrete 1:5:10 (1- Cement : 5-Coarse sand : 10- hand broken 196.40 Cum. 2,606.92
stone aggregates 40 mm nominal size) and curing complete excluding cost of formwork in (A)
Foundation and Plinth
4 Brick work using common burnt clay building bricks having crushing strength not less than 35 236.43 Cum. 4,245.09
kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine sand) (B)
5 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick 780.39 Sqmt 195.42
walls for interior plastering up to floor two level and finished even and smooth in (i) Cement
mortar 1:3 (1-cement:3-sand)
5.1 Extra over for finishing with a floating coat of neat cement slurry. 780.39 Sqmt 50.62
6 Refilling the Pipeline Trenches incl. Ramming, watering, consolidating and deposal of surplus 4,500.98 Cum 25.30
stuff as directed within a radius of 3 KM. Refilling as directed.
7 Providing and laying cement concrete work 1:2:4 (1- Cement : 2- Coarse sand : 4- graded stone 166.07 Cum 4,189.91
aggregates 20 mm nominal size) and curing complete excluding cost of formwork and
reinforcement for reinforced concrete work in (B) Slabs, landing, shelves, Balconies, Lintels,
Beams, Girders and Cantilever up to floor two level.
8 Providing formwork of ordinary timber planking so as to give a rough finish including centring 1,095.53 Sqmt 205.45
shuttering strutting and propping etc. height of propping and centring below supporting floor to
ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain
concrete work in. (H) (1) Sides and soffits of Beams Beam Haunching's cantilevers Girders
Bressummers and Lintels not exceeding 1 M. in Depth.
9 Providing and laying cement concrete work 1:2:4 (1- Cement : 2- Coarse sand : 4- graded stone 29.08 Cum 4,094.10
aggregates 20 mm nominal size) and curing complete excluding cost of formwork and
reinforcement for reinforced concrete work in (A) Foundations, footings, Base or columns and
Mass concrete For Benching
10 Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior 335.48 Sqmt 145.65
plastering up to floor two level and finished even and smooth in (I Cement mortar 1:3 (1-
cement:3- sand) above beaching
11 RCC precast M.H. Frame & Cover Manufacture, supply & Delivery at store or at site of work 598.00 Nos. 813.00
precast RCC M.200 Frame & cover suitable to drainage M.H. and as per type design & Drawing
including cost of reinforcement M.S. Angles or Flat, curing mold work etc.
House Connection Chamber Light duty
Sr. Description Total Unit Rate Amount
No. Qty. in Rs. in Rs.
12 Lowering, laying and jointing of class SN 8 structured wall ( External Annular Corrugated & 5,980.00 Rmt. 24.15
Smooth Internal surface) Polyethylene Piping and fittings with the help of coupler ( on line / off
line ) attached with one end of pipes, sliding over the elastomeric sealing rubber ring placed on
the specified valley of the corrugation at the spigot end, lowering the same into the trench at all
level, laying on the lower bedding (constructed at bottom of trenches) at prescribed
gradient,depth & alignment ,testing the water tightness of the joints, ensuring the continuity
tests of specified pipe segments etc. complete as per drawing,specifications & detailed
engineering, including carriage of pipes & fittings from site stacks to the place of laying etc. as
per direction of Engineer-in-charge.
Total for Schedule-B6(Rs.) =
Construction of House Connections
Description Qty. Unit Rate Amount
1 Providing and supplying of Class SN8 Structured Wall polyethelene Piping systems (Pipe with 11,960.00 Rmt 208.00
online/offline coupler and elastomeric sealing ring) with non-smooth External Annular Corrugated
and Smooth Internal Surfaces (Double Wall) for non-pressure underground Sewerage & Drainage
application as per EN:13476-3 including all local and central taxes, transportation, freight charges,
octroi, inspection charges, loading, unloading, conveyance to the departmental stores etc.
complete.(ID Dia)
2 Excavation for pipeline trenches for sewerage line, manhole etc. all with shoring and strutting if 5,025.88 Cum 102.35
required as per required gradient and line including safety provisions using site rails and stacking
excavated stuff including up to all required lead Cleaning the site etc. complete for lifts and strata as
In all sorts of soil and soft murrum
3 Providing and laying cement concrete 1:5:10 (1- Cement : 5-Coarse sand : 10- hand broken stone 201.57 Cum 2606.92
aggregates 40 mm nominal size) and curing complete excluding cost of formwork in (A) Foundation
4 Brick work using common burnt clay building bricks having crushing strength not less than 35 262.43 Cum 4245.09
kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine sand)
(B) Conventional
5 Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls 645.84 Sqmt 195.42
for interior plastering up to floor two level and finished even and smooth in
(i) Cement mortar 1:3 (1-cement:3-sand)
5.1 Extra over for finishing with a floating coat of neat cement slurry. 645.84 Sqmt 50.62
6 Refilling the Pipeline Trenches incl. Ramming, watering, consolidating and deposal of surplus stuff as 4,414.29 Cum 25.30
directed within a radius of 3 KM. Refilling as directed.
7 Providing and laying cement concrete work 1:2:4 (1- Cement : 2- Coarse sand : 4- graded stone 138.16 Cum 4189.91
aggregates 20 mm nominal size) and curing complete excluding cost of formwork and reinforcement
for reinforced concrete work in (B) Slabs, landing, shelves, Balconies , Lintels, Beams, Girders and
Cantilever up to floor two level.
8 Providing formwork of ordinary timber planking so as to give a rough finish including centring 1,260.58 Sqmt 205.45
shuttering strutting and propping etc. height of propping and centring below supporting floor to
ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete
work in. (H) (1) Sides and soffits of Beams Beam Haunching's cantilevers Girders Bressummers and
Lintels not exceeding 1 M. in Depth.
9 Providing and laying cement concrete work 1:2:4 (1- Cement : 2- Coarse sand : 4- graded stone 36.18 Cum 4094.10
aggregates 20 mm nominal size) and curing complete excluding cost of formwork and reinforcement
for reinforced concrete work in (A) Foundations, footings, Base or columns and Mass concrete For
10 Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering up 118.40 Sqmt 145.65
to floor two level and finished even and smooth in (I Cement mortar 1:3 (1-cement:3- sand) above
11 RCC precast M.H. Frame & Cover Manufacture, supply & Delivery at store or at site of work precast 1,196.00 Nos. 813.00
RCC M.200 Frame & cover suitable to drainage M.H. and as per type design & Drawing including cost
of reinforcement M.S. Angles or Flat, curing Mold work etc.
House Connection Chamber light duty
12 Lowering, laying and jointing of class SN 8 structured wall ( External Annular Corrugated & Smooth 11,960.00 Rmt. 24.15
Internal surface) Polyethylene Piping and fittings with the help of coupler ( on line / off line ) attached
with one end of pipes, sliding over the elastomeric sealing rubber ring placed on the specified valley
of the corrugation at the spigot end, lowering the same into the trench at all level, laying on the lower
bedding (constructed at bottom of trenches) at prescribed gradient,depth & alignment ,testing the
water tightness of the joints, ensuring the continuity tests of specified pipe segments etc. complete as
per drawing,specifications & detailed engineering, including carriage of pipes & fittings from site
stacks to the place of laying etc. as per direction of Engineer-in-charge.
Total for Schedule-B7(Rs.) =
Construction of 3.0 MLD Sewage Treatment Plant at Barwala
Description Qty. Unit Rate Amount
1 Design, supply, construction, installation, testing and commissioning of 1.00 4,76,93,627.06 No.
3.00 MLD Capacity sewage treatment plant based on Open Technology
with Biological Nutrient Removal (BNR) with MCC panel room, DG set and
all civil, electrical, mechanical, piping and instrumentation works with three
months trial run including but not limited to;
a) Connecting the existing rising main with all fittings up to the STP inlet
b) Internal roads of 4.5m
c) 33% green zone
d) Providing compound wall and
e) Discharge effluent pipe up to 500 m.
All other Constitions and General Technical Specification are as per GWSSB
02-Years of Operation & Maintanance For Drainage Network System
ITEM QTY. UNIT RATE (RS.) AMOUNT (Rs)
1 Comprehensive Operation and Maintenance of the various components of Under ground Drainage scheme 1 Year 6,53,048.43
undertaken in this tender mainly sewer collecting network, pumping station, Rising Main pipeline, pumping
machinery & Electrical works & other works as a whole including 1) Breakdown Maintenance or Emergency
Maintenance, 2) Day to day Maintenance, 3) Preventive or Periodic Maintenance, 4) Major Maintenance (or Special
repairs and replacement including Training to O & M staff of Municipality. The rate shall also include all consumables
and deployment of Manpower but excluding electric power (The electrical bill for power shall be paid by the
municipality) . The O & M work shall be carried out as per detailed specifications in the tender & maintaining the
record for the same. - For 1st year O&M
2 Comprehensive Operation and Maintenance of the various components of Under ground Drainage scheme 1 Year 6,85,700.85
undertaken in this tender mainly sewer collecting network, pumping station, Rising Main pipeline, pumping
machinery & Electrical works & other works as a whole including 1) Breakdown Maintenance or Emergency
Maintenance, 2) Day to day Maintenance, 3) Preventive or Periodic Maintenance, 4) Major Maintenance (or Special
repairs and replacement including Training to O & M staff of Municipality. The rate shall also include all consumables
and deployment of Manpower but excluding electric power (The electrical bill for power shall be paid by the
municipality) . The O & M work shall be carried out as per detailed specifications in the tender & maintaining the
record for the same. - For 2nd year O&M
Total for Schedule-C-1 (Rs.)
07-Years of Operation & Maintanance For Sewerage Treatment Plant
SR ITEM QTY. UNIT RATE (RS.) AMOUNT (Rs)
1 Operation and Maintenance of the various components of Upgraded 3.00 MLD Sewage Treatment Plant based on 1 Year 17,76,230.00
aeration system as per NGT Norms and other Under Ground Drainage Work as a whole incluiding,
1) Breakdown Maintenance or Emergency Maintenance,
2) Day to day Maintenance,
3) Preventive or Periodic Maintenance,
4) Major Maintenance (or) Special repairs and replacement including Training to O & M staff of Municipality.
The rate shall also include cost against fixed charges, consumables flow dependent charges, maintenance repair
charges, replacement charges, miscellaneous charges and deployment of manpower but excluning electric power. all
the components executed under this tender mainly pimping machinery, pumping station. Rising Main, including
estabilishment charges and all materials on repairing of pipe line and other civil works and pumping machinery. The
O & M work shall be carried out as per detailed specificstions in the tender & maintaining the record for O & M.
2 For 2nd Year 1 Year 18,65,041.50
3 For 3rd Year 1 Year 19,58,293.58
4 For 4th Year 1 Year 20,56,208.25
5 For 5th Year 1 Year 21,59,018.67
6 For 6th Year 1 Year 22,66,969.60
7 For 7th Year 1 Year 23,80,318.08
Total for Schedule-C-2 (Rs.)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
01_Vol-I-A_GUDC_Works_Tech_Barwala-UGD-II.pdf
02_Vol-I-B_SBD_GUDC_Works_GCC_Barwala-UGD-II.pdf
03_Vol-II-A-Part-1_Extent_of_Works_STP.pdf
04_Vol-II-A-Part-1_Extent_of_Works_UGD.pdf
05_Vol-II-A-Part-2_Gen_Tech_And_Process_Require_STP.pdf
06_Vol-II-A-Part-3_ITC_Mod_STP.pdf
07_Vol-II-B-Part-1_TS_for_Civil_Work_STP.pdf
08_Vol-II-B-Part-2_TS_for_Mechanical_Work_STP.pdf
09_Vol-II-B-Part-3_TS_for_Ele_and_Instru_Work_STP.pdf
10_Vol-II-C-Part-1_Func_Guran_of_the_Plant_Mod_STP.pdf
11_Vol-II-C-Part-2_Data_Sheet_for_Process_and_Civil_STP.pdf
12_Vol-II-C-Part-3_Data_Sheet_for_Mechanical.pdf
13_Vol-II-C-Part-4_Data_Sheet_for_Electrical_STP.pdf
14_Vol-II-C-Part-5_Data_Sheet_for_Instrumentation_STP.pdf
15_Vol-II-D-Part-1_Technical_Data_Sheet_Barwala_UGD-II.pdf
16_Vol-II-D_Part-2_Item_Tech_Spec_Civil_Elect-Mech_UGD-compressed.pdf
17_Vol-II-General_Part-1_Gen_Tech_Spec_Civil_R_and_B.pdf
18_Vol-II-General_Part-2_Gen_Tech_Spec_Electrical-pages-1.pdf
18_Vol-II-General_Part-2_Gen_Tech_Spec_Electrical-pages-2.pdf
19_Vol-III_SBD_GUDC_Works_Price_Bid_Barwala-UGD-II.pdf
20_Vol-III_SBD_GUDC_Schedule-B_Barwala-UGD-II-compressed.pdf
21_Vol-IV_Bid_Drawing_Barwala-UGD-II-pages-1.pdf
21_Vol-IV_Bid_Drawing_Barwala-UGD-II-pages-2.pdf
22_Vol-V_Cond_of_Cont_for_O_and M_UGD_Barwala_STP.pdf
23_Vol-V_Cond_of_Cont_for_O_and M_STP_Barwala_STP.pdf
24_Price_Variation_Paripatra_16.03.2023.pdf
25_GR_DOC_1.pdf
26_GR_DOC_2.pdf
27_DMO_2941_01-Apr-2026_744.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .