| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 LAccepted-AOC U 57 OPP AGGARWAL NURSING HOME RAJU GAS AGENCY OFFICE VIJAY NAGAR NARELA DELHI DELHI 110040 | NORTH | DELHI | 110040 | ₹1.6 L | L1 | Accepted-AOC L1 |
| 2 | L2₹1.6 LSame as L1Rejected-Finance | ₹1.6 LSame as L1 | L2 | Rejected-Finance L2 |
| 3 | L3₹1.7 L+₹10,691.86 (6.52%)Rejected-Finance F 1 1ST FLOOR EAST JYOTI NAGAR SHAHDARA DELHI DELHI 110093 | NORTH EAST | DELHI | 110093 | ₹1.7 L+₹10,691.86 (6.52%) | L3 | Rejected-Finance L3 |
| 4 | L4₹1.8 L+₹12,678.67 (7.73%)Rejected-Finance | ₹1.8 L+₹12,678.67 (7.73%) | L4 | Rejected-Finance L4 |
| 5 | L5₹1.8 L+₹15,730.56 (9.59%)Rejected-Finance | ₹1.8 L+₹15,730.56 (9.59%) | L5 | Rejected-Finance L5 |
Tender Value
₹2.0 L
EMD Value
₹4,500
Closing Date
27 Mar 2026, 5:05 pmClosed
Ex. Engineer(Elect.)/CNZ
C-Block, Defence Colony, New Delhi 110024
Provision of E.I and Fans in Kalkaji Malaria office In ward no. 175 under Central Zone.
2026_MCD_273190_1
EE(Elect.)/CNZ/2025-26/69-02
Open Tender
Electrical Works
Percentage
60 days
Ward 175
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹4,500
14 Jul 2026
26 Mar 2026
27 Mar 2026
26 Mar 2026
27 Mar 2026
26 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C | 26 | point | 1,704 | ₹44,304 |
| 2 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required(a)2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 40 | PM | 311 | ₹12,440 |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (a)2 X 4sq. mm + 1 X 4 sq. mm earth wire | 50 | PM | 373 | ₹18,650 |
| 4 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire | 10 | PM | 482 | ₹4,820 |
| 5 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire | 30 | PM | 452 | ₹13,560 |
| 6 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 4 sq. mm + 2 X 4 sq. mm earth wire | 30 | PM | 587 | ₹17,610 |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. | 8 | Each | 545 | ₹4,360 |
| 8 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required | 8 | Each | 659 | ₹5,272 |
| 9 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. (a) Up to 450 mm sweep | 4 | Nos. | 556 | ₹2,224 |
| 10 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door | 1 | Each | 2,773 | ₹2,773 |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 12.40 MB
Tendernotice_2.pdf
PDF • 5.88 MB
Tendernotice_3.pdf
PDF • 0.10 MB
BOQ_318852.xls
BOQ • 0.80 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .