Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-AOC 53 SHANTI S SANIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹2.5 L+₹6,676 (2.73%)Rejected-Finance | L2 | Rejected-Finance 2ND LOWEST BID | |
| 3 | L3₹2.7 L+₹23,676 (9.68%)Rejected-Finance LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L3 | Rejected-Finance 3RD LOWEST BID | |
| 4 | L4₹2.9 L+₹40,956 (16.7%)Rejected-Finance | L4 | Rejected-Finance 4TH LOWEST BID |
Tender Value
₹2.8 L
EMD Value
₹5,500
Closing Date
15 Nov 2019, 6:00 pmClosed
GE Dronachal
GE Dronachal, Dronachal Top, Neori Hills, Bhopal
PROVN OF CERAIN MINOR WORKS AT DRONACHAL BHOPAL
2019_MES_287369_1
8488/E8
Open Tender
Electrical Maintenance Service
Item Rate
180 days
GE Dronachal
Please refer tender documents
5 documents required · 5 mandatory
₹500
Yes
GE Dronachal
₹5,500
Yes
16 Jan 2020
4 Oct 2019
18 Nov 2019
4 Oct 2019
15 Nov 2019
18 Oct 2019
Amount
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for laying cable and getting out in hard/dense soil complete all as specified and directed.
Returning filling in including spreding, leveling, watering and well ramming in layers n exc. 25 cm in softt/loose soil all as specified and directed .
Removing surplus excavated materials (soils) upto a distance not exc. 50 meter and depositing where directed at a level not exc. 1.5 meter above the starting point complete all as specified and directed..
Supply and spread sand in trenches as sand cushioning to underground cable for protection with fine river sand and provide required cover after punning down complete all as specified and directed. Note: Thickness of sand cushion after punning down will be measured and paid)
Sub class 'B' old size well burnt brick laid flate in trenches as protection to LT cable complete all as specified and as directed.
S&F Cable in trenches or passing through pipe or fixing to pole of 1100 volts grade heavy duty cable with XLPE insulated, stranded aluminium conductor, served with inner sheathing of PVC tape, armoured with galvanised steel wire or strip and overall PVC sheathed nominal cross sectinal area 25 Sqmm, 3.5 core, all as specified and directed.
Supply and laying GI tubing 'light grade' 50 mm dia complete with all fittings to walls and ceiling or laid in floors/road crossing (for cable protection) all as specified and directed.
S&F, out door feeder pillar box weather & vermin proof suitable ventilated 3 Phase, 4 wire, 440 volts, 50 Hz, factory assemble & factory fabricated and compartmentalised out of 2 mm thick sheet steel duly powder coated paint over one coat of red oxide zinc chrome primer, with bus bar chamber to accommodate epoxy painted high conductivity aluminium bus bar of capacity 250 Amps (3 Ph, 4 Wire) including digital type multi functional meter to measure voltage 0 - 500 volts & 0-100 Amps with suitable CT's phase indication neon lamps, necessary glands cable connection with proper lugs, PCC foundation & pedestal for fixing feeder pillar box with required PCC work in fondation with PCC (1:2:4 ) type B1 using 20 mm graded stone aggregate and plastering 15 mm thick in CM ( 1:6) and including following Accessories complete :- INCOMING (a) MCCB ,4 Pole, 415 Volt,125 Amp,25 KA -01 Nos. OUT GOING (a) MCCB ,4 Pole, 415 Volt,63 Amp,10 KA-04 Nos Note: (i) Make of LT Panel : Juhi/ Deor/BSPL/ Mc layer (ii) Drawing of panel to be got approved from AGE E//M before procurement.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for laying cable and getting out in hard/dense soil complete all as specified and directed.
Returning filling in including spreding, leveling, watering and well ramming in layers n exc. 25 cm in softt/loose soil all as specified and directed .
Removing surplus excavated materials (soils) upto a distance not exc. 50 meter and depositing where directed at a level not exc. 1.5 meter above the starting point complete all as specified and directed..
Supply and spread sand in trenches as sand cushioning to underground cable for protection with fine river sand and provide required cover after punning down complete all as specified and directed. Note: Thickness of sand cushion after punning down will be measured and paid)
Sub class 'B' old size well burnt brick laid flate in trenches as protection to LT cable complete all as specified and as directed.
S&F Cable in trenches or passing through pipe or fixing to pole of 1100 volts grade heavy duty cable with XLPE insulated, stranded aluminium conductor, served with inner sheathing of PVC tape, armoured with galvanised steel wire or strip and overall PVC sheathed nominal cross sectinal area 10 Sqmm, 4 core, all as specified and directed.
Supply and laying GI tubing 'light grade' 25 mm dia complete with all fittings to walls and ceiling or laid in floors/road crossing (for cable protection) all as specified and directed.
S&F outdoor panel board suitable size for incoming MCB four pole 63 Amps 415 Volt and outgoing MCB DP 32 Amps -03 Nos including Timer and contractor ,internal wiring with copper wire and fixed on PCC foundation complete all as specified and directed..
S&F Cable in trenches or passing through pipe or fixing to pole of 1100 volts grade heavy duty cable with XLPE insulated, stranded aluminium conductor, served with inner sheathing of PVC tape, armoured with galvanised steel wire or strip and overall PVC sheathed nominal cross sectinal area 16 Sqmm, 4 core, all as specified and directed.
S&F Cable in trenches or passing through pipe or fixing to pole of 1100 volts grade heavy duty cable with XLPE insulated, stranded aluminium conductor, served with inner sheathing of PVC tape, armoured with galvanised steel wire or strip and overall PVC sheathed nominal cross sectinal area 35 Sqmm x 3.5 core, all as specified and directed.
S&F Cable in trenches or passing through pipe or fixing to pole of 1100 volts grade heavy duty cable with XLPE insulated, stranded aluminium conductor, served with inner sheathing of PVC tape, armoured with galvanised steel wire or strip and overall PVC sheathed nominal cross sectinal area 06 Sqmm x 2 core, all as specified and directed.
Dismantling of ACSR or AAC conductors/GI wire complete all as specified and directed. Note :- (Dismantling of MS work and insulatores shall be removed and paid separately)
Dismantling cross-arms of M.S. channel or angle sections etc. Complete and setting aside reusable channel for reuse with in 50 m complete all as specified and directed.
Dismantling insulator any type, any size complete all as specified and directed.
Dismantling of stay assembly complete all as specified and directed.
Taking down old/unserviceable stay wire of any size complete all as specified and directed.
Supply and fix stay assembly with accessories as shown in electrical plate No 1, comprising of MS galvanized stay plate 23 cm x 23 cm x 6 mm, galvanised stay rod 16 mm dia with nut 100 cm long , MS galvanised stay bow 40 cm long with 01 Nos galvanized thimbles with and including all fittings all as specified in SSR 2010 Part I. Note : (loop type insulator, stay clamps, excavation and concrete to be measured and paid separately).
M&L galvanised stay strand, 7/4 mm complete all as specified and directed.
S&F loop type insulator, vitreous porcelain, white, brown or green, large size, with overall dimensions of 90 x 140 mm, clearance of hole 25.5 mm complete all as specified and directed.
Supply, install, testing and commisioning of factory made outdoor busbar panel box suitable for 415V, 50Hz, 3Phase 4Wire AC Supply ,dust and vermin proof, outer body, outer door,roof,mounting channel fabricated with 2 mm thick CRCA sheet and compartment door with 2mm thick CRCA sheet , powder coated , treated insulated compartment of busbar and MCCB 200 Amps 4 pole, 25 KA (incoming) -01 No with LED indication lamp (RYB colour) , overall front and rear door with locking arrangement top sloped ,projection at each side, suitable channel,internal wiring with copper wire etc complete of end terminal and Fixed including supplying and fixing on MS chanel 75mmx40mmx5mm groated in PCC foundation etc all as specified and directed..
M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundtion of pole/stay assembly ,mass concrete.etc including necessary form work , all as specified and directed.
Supply and laying GI tubing 'light grade' 50 mm dia complete with all fittings to walls and ceiling or laid in floors/road crossing (for cable protection) all as specified and directed.
Dismantling and removing of old PCC Pole complete and deposit to MES store yard
S&F Cable in trenches or passing through pipe or fixing to pole of 1100 volts grade heavy duty cable with XLPE insulated, stranded aluminium conductor, served with inner sheathing of PVC tape, armoured with galvanised steel wire or strip and overall PVC sheathed nominal cross sectinal area 10 Sqmm, 4 core, all as specified and directed.
Dismantling and setting aside use within 50 metres old steel pole complete
M&L for PCC 1:2:4 type B-1 (Using 20 mm graded stone aggregate) as in coping/benching incl wheathing slightly chamfered on edge and finishes exposed surfaces even smooth with out using extra cement including necessary from work complete all as specified and directed .
M&L for PCC 1:4:8 type D-2 (Using 40 mm graded stone aggregate) as in foundation filling and mass concrete for stay and poles complete all as specified and directed.
Supply and fix LT cable joiniting kit 1100Volts grade cable for indoor/outdoor joint heat shrink type complete with jointing material and accessories suitble for 4 core XLPE armoured aluminium conductor cable of size 10 to 16 sqmm
PRAGTI ELECTRICALS AND ELECTRONICS
PRAGATI ELECTRICALS AND ELECTRONICS
Neelam Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .