| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC | ₹34.4 L Quoted ₹35.0 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹39.2 L+₹4.3 L (12.3%)Rejected-Finance 3 SHITALNATH FLATE 1 NR KHANPUR JAIN TEMPLE OPP BANK OF INDIA SHAHPUR AHMEDABAD GUJARAT 380001 | AHMADABAD | GUJARAT | 380001 | ₹39.2 L+₹4.3 L (12.3%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹39.8 L+₹4.9 L (14.0%)Rejected-Finance 00 IN FRONT OF SHIVPURI HOTEL NEAR KOTHI NO 14 SHIVPURI MADHYA PRADESH 473551 | SHIVPURI | MADHYA PRADESH | 473551 | ₹39.8 L+₹4.9 L (14.0%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹40.7 L+₹5.7 L (16.4%)Rejected-Finance | ₹40.7 L+₹5.7 L (16.4%) | L4 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹72,000
Closing Date
24 Mar 2022, 6:00 pmClosed
Maj Yogender Singh
GE Navy Porbandar Tija Mile Porbandar
SPECIAL REPAIRS TO BUILDING NO. P-86 (SENIOR SAILOR BLOCK) AT INS SARDAR PATEL UNDER GE NAVY PORBANDAR
2022_MES_505459_2
9112/PBR/E8
Open Tender
Civil Works
Item Rate
180 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹72,000
Yes
30 Mar 2022
4 Mar 2022
26 Mar 2022
4 Mar 2022
24 Mar 2022
11 Mar 2022
4 Mar 2022 - 10 Mar 2022
Amount
Dismantling of floor hearth and wall tilling incl mortar beding removing serviceable tiles to store and rubbish off the premises as directed by the Engr-in-Charge
Non-skid ceramic tiles, coloured (of approved shade and design), 7 to 8mm thick, of superior quality, square / rectangular 300mmx300mm 7 to 8mm thick (area exceeding 0.06 Sqm but not exceeding 0.11 Sqm) , as in floors, etc.set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match shade of tiles laid over & including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
Non-skid ceramic tiles, coloured (of approved shade and design) of superior quality, square / rectangular 400mmx400mm x 7 to 8mm thick (area exceeding 0.11 Sqm but not exceeding 0.18 Sqm), as in floors, etc.set and jointed in neat cement slurry and pointed with white cement mixed with pigment including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
Glazed ceramic tiles, coloured (light colour as approved), of size 300x 600 x7mm/ 350x250mm x 7mm / 450X 350X 7mm x300mmx200mmx7mm thick on vertical surfaces such as in skirting/dado etc set and jointed in cement slurry over 10mm thick rendering in cement mortar (1:4) and pointed in white cement mixed with pigment to match the colour of tiles complete all as specified
Cement concrete tiles 25cm x 25cm x 22 to 25 mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished over 15mm thick screed in cement mortar (1:6) and pointed with cement and suitable pigment (mixed with white cement) to match the colour of tiles complete all as specified.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.laid dry beded in any mortor complete all as specified.
Granite 20mm thick machine cut, bedded andjointed as in cills, jambs, steps and the like with grey cement slurry and pointed with white cementwith admixture of pigment to match the shade of granite stone including grinding and polishing , etc with 15mm thick screed in cement mortar (1:4) complete all as specified.
20mm thick Granite machine cut, in skirting/dado door window sill, jambs etc laid over cement screed ( 1::3) and jointed with grey cement slurry, and pointed with white cement with admixture ofpigment to match the shade ofgranite stone including grinding and polishing complete all as specified.
Demolition of brickwork or stone/boulders/block masonry, built in cement mortar including all quoins, arches, pillars, ashlar facing, dressed stonework, precast concrete artilcles and precast concrete block walling etc. Complete all as specified and directed.
Stone masonry walling or squred walling in cm 1:6, brought upto courses using dressed same size Porbandar stone of superior quality complete all as specified and directed.
Stone masonry walling or squred walling in cm 1:6, brought upto courses but except stone complete all as specified and directed (Serviceable stones retrieved from item No. 10 will be reused).
Taking down cement plaster of any description incl raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
Rendering 15mm thick on fair faces of brickwork or concrete surfaces 'in CM 1:4 finished even and smooth without using extra cement all as specified and directed.
Rendering 5mm thick in CM 1:3 on concrete surfaces finished even and smooth without using extra cement as in ceiling complete all as specified and directed.
Forming jambs, etc. with CM ( 1:6) or Cement Concrete 1:1:8 to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as spd
Preparation of new plastered surfaces and applying two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of white primer and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complet`e, as per manufacturer's specification complete all as spd and as directed by Engineer in Charge
Preparatiion of new plastered surfaces and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as spd and as directed by Engineer in Charge
Preparation of new plaster surface of ceiling applying three coats of white wash complete all as spd
Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces complete all as specified.
Preparation of old steel surfaces of any description, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified.
Material and labour for preparation of old wooden surfaces of any description exceeding 10 cm width or grith not otherwise described and applying one coat of syntheic enamel paint complete all as specified and as directed.
Preparation of new or previously untreated surface of wood or wood based materials of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified.
Complete removal of existing treatment from old plastered/pointed surfaces(Dry distember,white / lime wash etc) and Applying two coats of water based distemper over a coat of primer including applying 2mm thick wall putty to filling nail holes,cracks etc smooth, finished even and smooth complete all as specified and as directed by Engineer in Charge.
Preparation of old surfaces of ceiling including cornicess plasters and applying one coat of lime wash (white washing) on ceiling complete all as specified and directed.
M & L preparation of old plastered surfaces as in External walls, soffits & facias of beam ,chajjas & incl roof/floor bottom ceiling portion in etc applying two coats of weather coat proof Acrylic based exterior emulsion paint over a coat of primer of shade as approved by GE complete all as specified.
Taking down chowkats or frames n.exc 1.5 Sqm each with shutter (without taking off Shutter) complete all as specified.
Taking down chowkats or frames exc 1.5 sqm and n.exc 4 Sqm each with shutter (without taking off Shutter) complete all as specified.
Factory made 35 mm thick,2nd class hard wood (Hollock), glazed and skeleton shutters open rebated and prepared to receive glass/ gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass etc for doors, size of members as specified in clause 8.24 (a) of MES Schedule Part-I Section-8, complete all as specified.
35mm 2nd class HW rail and style Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified.
Plain solid, straight chowkats and frames of second class hard wood Wrought Framed rabatted on the solid rounded or chamfered, put together with glue pinned at joints Complete all as specified and directed.
Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame complete as specified by the manufacturer and as per directions of Engineer-in-charge.
Supply and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge.
S & F Stainless steel curtain rod fixing with side brackets, finials on both end of every opening length end cups, etc and fixed with PVC rawl plugs & steel screws as in repairs complete all as specified.
Dismantling boarding, any description, fixed in any position with nails complete all as specified.
18-19mm thick pre-laminated particle board (incl dismantling), flat pressed single layer type or three layer type with BWR type adhesive, medium density interior grade having one side decorative lamination and other side balancing white lamination as in cup board shutter , shelves etc including 6 mm thick teak wood leaping on three sides and 20mm thich on hanging side & French polishing to edging complete all as specified.
300mm long (Length of Bolt in mm) Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified.
150mm long (Length of Bolt in mm) Aluminium anodised, barrel tower bolts of extruded section and fixed all as specified and directed.
150mm (Size of Handle in mm) Aluminium handles, cast type, anodised all as specified.
100mm self closing Butt hinges (Size of hinges in mm), medium weight, cold rolled, stainless steel, and fixed all as specified.
Hasp and staple of aluminium anodized, safety type, 100mm long, fixed with screws complete all as specified.
75mm aluminium handle, cast type anodised complete all as specified.
75 mm mm self closing Butt hinges(Size of hinges in mm), medium weight, cold rolled, stainless steel, and fixed all as specified.
Dismantling structural steel work including doors, gates but excluding framed trusses complete all as specified.
Framed work ( Fe 410 -W(Gde-E- 250) quality-A)- as in doors or gates of angle or other section with gusset plates, rails, posts, braces, rafters, purlins etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing as in repair complete complete all as spd and directed by Engineer in Charge.
Supply and fixing of powder coated aluminium section of overall size of outer frame 90mmx34.5mmx1.2mm thickness fixing with gasket, beading , Star lock also Gaps to be filled with weatherproof Silicon Sealant( both sides ) , and fixing to opening area incl necessary cleats , brackets, screws bolts, Fixed to wall , floor a etc as in repair complte all as specified and as directed By Engineer In Charge
S&F anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
Supply and fixing powder coated aluminium sliding window shutters, , aluminium section ( 40mm(Ht) x18mm-20mm (W) x1.2mm thickness aluminium Section for window Shutters ) including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1 No.) or hinges type B-21 100 mm long (2 nos.), suitable handle or Star lock, (1 no.) gasket, , Fixing arrangement with Stainless Steel Mesh or Plain glass section . etc as in repair complete all as specified and directed. NOTE : Glass & Wiremesh shall be paid separately
Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin- charge complete all as specified and directed.
Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples.etc as in repair complete all as spd
S& F in repair to Powder coated Aluminium doors of section incl chowkat size of door n.exe 4 Sqm (chowkat 101mmx44mmx 1.5mm wall thickness, stiles, top & lock rail of shutter 80mmx44mmx1.5mm wall thickness, bottom rail Min 90mmx44mmx2mm thick wall thickness) including aluminium hinges, aluminium tower bolts 200mm, aluminium handle 150mm, 4 mm thick plain glass,necessary jointing cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws & 1 nos hydraulic door closer of aluminium body,mortice lock four levers with two Nos keys etc complete all as specified and directed by Engineer in Charge
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor over all length of cover 150 mm complete all as specified and directed.
M&L for water proofing treatment to existing RCC roof slab including preparation of surfaces parapet comprising with the following course of treatment/ specification from bottom to top:- (a) Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (b) one layer of APP based polymeric membrane of approved manufacturer, 3 mm thick, weight not less than 3.0 Kgs per Sqm, reinforced with non wovwn polyster fabric or weight not less 160 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm minimum) and then inserted insde the groove of parapet wall and shall be finished by a membrane flashing. (Note:- (i) Laying of APP based membrane shall be done by torch on method or as per manufacturers instruction. (ii) A minimum overlap of 150 mm and 100 mm should be made in the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as manufacturers instruction. (c ) Applying two coats of reflective Bituminous aluminium paint on top of APP membrane. Laying of Standard APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) including removal existing treatment , complete all as specified and directed by Engineer in Charge
M&L for 10 mm thick (average) plastering on concrete surfaces in cement mortar 1:4, in order to maintain proper slope and base over existing roof surfaces for laying of APP based polymeric membrane, including add WPC @3% of cement weight ( Dr Fixt /Cera /Krishna etc ) , finished even and smooth without using extra cement complete all as specified and as directed. (Note:- Rate includes WPC & Polymeric membrane will be measured and paid separately)
Special treatment of sunken portion of WCs and Bath room as per following stages:Stage 1 :- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc .Stage 2:- Providing 10mm thick plaster in CM 1:4 with chemical of Dr. Fixit Pidicrete URP/SIKA /plaster seal of STP Ltd or Equallent Stage 3:- Applying Dr Fixit Primseal primer or STP Ltd(and allow to dry for 8 hours) under touch dry condition Stage 4:- Applying two coats of water proofing of Dr Fixit Pidicrete for the sunken portion of toilets/bathrooms (The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per manufactutrer instruction Stage 5:-Again rendering 10mm thick in CM 1:4 mixed with Dr Fixit Pidicrete URP or plaster seal of STP Ltd. Stage 6. All CI joints shall filled with mixture of cement fine sand and plaster seal of STP Ltd or Dr Fixit pidicrete URP. Stage 7:- Making holes in wall and fixing 600mm long 25mm dia GI spout for draining the surplus water if any.
Plain cement concrete (1:5:10) type E-2 using 40mm gdd stone agg as in floor filling as mass concrete or in sub base of floors complete all as specified.
Plain Cement concrete (1:2:4), type B-0 using 12.5mm graded stone aggregate min radius of 75mm thick as in roof and parapet wall junction , roof benching, kerbs, mud stop, coping, rounded or chamfered on edges, filling rails embedded sec etc incl necessary sloping on roof top surfaces including form work complete all as specified.
Demolition of unreinforced cement concrete in ground floor and paving n.exc 15 cm thick below or above ground level complete all as specified and directed
75mm Cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in plinth protection,Floor topping etc , surfaces finished of concrete flooring with brooming / checked finish complete all as spd u including provision of necessary construction joints filled with bitumen filler etc complete all as directed by Engr-in-Charge
Taking up or down existing steel water tubing, 15mm, 20mm & 25mm bore alongwith connections fixed/laid in any situation, complete all as specified
CPVC tubing, 25mm bore including fittings such as bends, tees, elbows, short pieces, connectors, back nuts and connections fixed in new or old position (walls, ceiling, floors) complete all as specified and directed.
CPVC tubing, 20mm bore including fittings such as bends, tees, elbows, short pieces, connectors, back nuts and connections fixed in new or old position (walls, ceiling, floors) complete all as specified and directed.
CPVC tubing, 15mm bore including fittings such as bends, tees, elbows, short pieces, connectors, back nuts and connections fixed in new or old position (walls, ceiling, floors) complete all as specified and directed.
S& F in repair PVC (SWR) pipes, 110mm bore, single socketed, 2.50 Kgf per Sqcm pressure, in any length with rubber ring joints complete all as specified and as directed.
S&F 110mm dia bore PVC (SWR) bends, single / double 'Y' or 'T', with access doors, any radius including fixing clips complete all as specified and as directed
S& F in repair PVC (SWR) pipes, 75mm bore, single socketed, 2.50 Kgf per Sqcm pressure, in any length with rubber ring joints complete all as specified and as directed
S&F 75mm dia bore PVC (SWR) bends, single / double 'Y' or 'T', with access doors, any radius including fixing clips complete all as specified and as directed.
S & F in PVC (SWR) junction single, (Single T) equal or unequal of size 110mm complete all as specified and as directed.
S & F in PVC (SWR) junction single, (Single T) equal or unequal of size 75mm complete all as specified and as directed.
S & F in PVC (SWR) vent cowl of size 110mm complete all as specified and as directed.
S & F in PVC (SWR) vent cowl of size 75mm complete all as specified and as directed.
S & F in 75mm PVC (SWR) floor trap, plain with grating including jointing set to solvent cement and white cement complete fixtures all as spd
S & F in PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete fixtures all as spd
1000 Ltr Cap Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position with inlet outlet with suitable PVC Float Valve etc connections all as specified in SSR Part I Complete all as spd and as directed by Engineer in Charge
S & F in Ball valves high pressure (min 1.5 psi to 2psi)of PTMT with epoxy coated aluminium rod and high density plastic ball ( long/big size ) screwed for iron pipe and fixed for 25mm bore pipe (Minimum weight-455gms), fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Disconnecting existing tanks up to 500 ltr cap, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position with Cleaning , repairing,incl complete connection with inlet and outlet with GI / CPVC pipe fitting , Float valve etc Complete all as spd and as directed by Engineer in Charge
S&F in repairs Vitreous China wash down water closet pan (European type) with P or S trap, snow white or white colour, fixing bolts, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc complete, excluding flushing cistern and flush pipe including seat cover complete all as spd and directed by engineer in charge.
S&F in repairs min 10 litres capacity PVC flushing tank, syphonic action type, high / low level, valveless, with PVC inlet ball valve, PVC flush pipe, float, chain and pull and suitable sized brackets including taking down / dismantling old unserviceable flush tank (any type) and disposing off complete all as specified and directed by Engineer in charge.
S & F in fancy type (Vitreous Ceramic ivory or snow white) pedestal patten hand wash basins with full pedestal of size 630x450mm (Cat Model No. CERA CORNET / CONCORD / CALIBRE) wall with all necessary fittings with fixing arrangements and connecting to water pipe with existing water system etc including suitable pillar tap ( CERA MODEL F1015101 or make as specified or Equivalent model of make as specified here-in-after.
15mm bore pillar tap, cast copper alloy( Swan neck type ) , with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly-nuts, screwed for iron pipe, as in repair complete all as specified.
Soap dish brass chromium plated, vitreous China white, approximate size 160x 160x90mm fixed to plugs with chromium plated brass screws complete all as specified.
Toilet paper Holder brass chromium plated with flap guard as in repair complete all as specified and directed by Engineer in charge.
S&F in repairs fancy type Chromium plated towel rail, 600mm long (24"), complete all as specified.
S & F in Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified.
S&F in repair to ABS body Health faucet with wall hook and 1 metre SS braided rubber holes pipe complete all as specified.
S&F in repairs CP brass wall mixer for mixing hot & cold water with bend pipe for over head shower screwed down for CPVC and fixed as in repair complete all as specified.
S&F in repairs to15mm bore fancy type CP Stop Cock cock or angle with wall flange complete all as specified.
S&F in repairs to Bib cock long nose with wall flange and aerator for CPVC pipe and fixed complete all as specified.
S&F in repairs to two way Bib cock long nose with wall flange and aerator for CPVC pipe and fixed complete all as specified.
S & F in repair Low density polythene pipe (LDPE) of pressure rating 6 Kg per Sq.cm,600mm long, heavy duty with two sets of brass nuts & washers (one at each end) etc suitable for 15mm bore of pipe complete all as specified.
S&F in repairs to CP grating square min 150mm size Complete all as secified.
M&L Chequered cement concrete tiles 20cm x 20cm x 22 to 25 mm thick set jointed and pointed with grey cement with CM (1:3) with WPC & pigment filled with pigment in neat cement slurry in floors & Roof surface (roof surfaces with 2 to 3 mm spacer) with grouting complete all as specified and directed.
S&F machine pressed precast concrete interlocking paver block any shape size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigment fixed over and including 50 mm thick sand cushioning complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light/fan, buzzer, socket or power point etc) complete including all fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc including making good the disturbed surface to match with the existing all as specified and directed by Engineer-in-charge.
Point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for the following:-
One light or fan point controlled by one one way switch
One ceiling fan/exhaust fan controlled by one way switch
All as per above item No. 96.00 but wire 1.5 sq mm cable for switch socket outlet 3 pin 5 amps with 1.5 sq mm cable as earth continuity conductor.
All as per above item No. 96.00 but below/parallel the switch board of independent 5 Amps socket in the same vertical/horizontal board.
Point wiring with 2.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for Description a for independent switch socket outlet 6 pin 5/15 Amps complete all as Specified and directed by Engr-in-Charge.
Switch piano 1 way 6A, 1 module all as specified and directed by EIC.
Ceiling rose surface bakelite 65x50mm 3 terminal complete all as specified and directed.
Modular socket 6A, 2/3 pin combined, 2 modules 230 volts complete all as specified and directed.
Modular switch 1 way 16 Amps, 1 modules 230 volts complete all as specified and directed.
Modular socket 16A, 2/3 pin combined, 2 modules 230 volts complete all as specified and directed.
Ceiling fan electronic regulator five step 02 module, hum free, AC, 230 volts, 100 watts complete all as specified & directed.
Taking down existing ceiling fan / exhaust fan any size, any make, refixing the same after replacing the rubber bushes, split pin, servicing, greasing and painting with two coats of synthetic enamel paint (spray painting) complete all as specified and directed.
Supply and fixing ENDURA LINEAR NEO (1200mm) 20 W LED fitting baten fro surface and wall conduit mounting High Transmissitivity diffuser High lumen Output PF > 0.98, thd < 10 % wall mounted type fitting with LED tube rod , complete all as specified and directed by Engr-in-Charge. Make : Havells No :- ENDURALINEARNEOBS20WLED865SPCWH or equivalent model of make specified in appx 'B' hereinbefore.
Supply and fixing ENDURA LINEAR NEO (600mm) 10 W LED fitting baten fro surface and wall conduit mounting High Transmissitivity diffuser High lumen Output PF > 0.98, thd < 10 % wall mounted type fitting with LED tube rod , complete all as specified and directed by Engr-in-Charge. Make : Havells No :- ENDURALINEARNEOBS10WLED865SPCWH or equivalent model of make in PHILIPS/CG.
Supply and fixing EDGEPRO SQUARE TYPE 12 WATT DOWN LIGHT new generation Recessed mounting low height backlit square LED downlight with non integral driver provides high quality ecomonic energy saving lighting to modern offices complete all as specified and directed by Engr-in-charge. Make : Havells No :- EDGEPROSQDLR12WLED857S or equivalent model of make in PHILIPS/CG.
Supply and fixing Flood light of minimum 70W luminaire grey powder coated dire-cast aluminium housing, built in control gear faceted anodised aluminium reflector heat resistant toughened clear glass cover complete all as specified and directed. Make : HPLLEDFL7260F or its equivalent model of make specified here-in-before.
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps fixed in repair / replacement complete all as specified and directed.
MCCB 4 pole 100 Amps, breaking capacity 16 KA, 415 Volts, fixed thermal & magnetic releases, (Conforms to IEC:60947-II / IS:13947-II) fixed in repairs complete all as specified and as directed by Engineer-in-charge. Make Legrand Model No DPX3 160, Cat No 4200 15 compatible model of make as specified in Appx 'B' herein after complete all as specified.
Supply and fixing MCCB, AC 415 V, 50 HZ, fixed type, capacity 100 Amps, 3 Pole, 16 KA, suitable to be fixed in 4/6/8 way TPN DB fixed in repair / replacement complete all as specified and directed.
S & F in repair MCB DB double door SPN 8 Way with 200 Amps rated copper bus bar complete all as specified and directed.
MCB SP 6-32 Amps,10 KA breaking capacity suitable for 230 V,50 Hz for lighting and other domestic load complete all as specified and directed by Engineer - in - Charge.
MCB SP 415 Volts AC 63 Amps of breaking capacity 10 KA fixed in repair / replacement complete all as specified and directed.
MCB SPN 40 to 63 Amps, 10 KA breaking capacity suitable for 415 V, 50 Hz AC complete all as specified and directed by Engineer - in - Charge.
MCB SP 240 Volts AC 40 Amps of breaking capacity 10 KA fixed in repair / replacement complete all as specified and directed.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level Glvanized earth plate connected with GI earth strip 25x4mm by means of lug, bolts, nuts, check nuts, washers of galvanised iron GI protection pipe 32 mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover, fixed in repairs, including testing on completion complete all as specified and directed.
Sub main wiring concealed with 10 Sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistrand unsheathed copper conductor cable 1100 V grade, ISI marked with copper conductor drawing into rigid non-metallic PVC concealed conduit complete with including 10 sqmm (nominal area) single core PVC insulated multistrand unsheathed FRLS copper conductor as earth wire and duly connected to all common earth point, complete all as Specified and directed by Engr-in-Charge. (Conduit shall be measured and paid separately).
Sub main wiring concealed with two runs of single core 6 Sqmm (Nominal area) cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, ISI marked with copper conductor drawing into rigid non-metallic PVC concealed conduit complete with including one run of 6sqmm (nominal area) single core PVC insulated multistrand unsheathed FRLS copper conductor as earth wire and duly connected to all common earth point, complete all as Specified and directed by Engr-in-Charge. (Conduit shall be measured and paid separately).
20 mm rigid non-metallic PVC concealed conduit medium grade including all PVC conduit accessories, cutting / chases and making good disturbed surfaces complete all as specified and directed.
Supply laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 10 sqmm 4 core suitable for working on 1100 Volts, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe shall be measured and paid for separately.
Supply laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 50 sqmm 3.5 core suitable for working on 1100 Volts, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe shall be measured and paid for separately.
Hot press moulded SMC junction box 240mm x 130mm x 95mm (inside dimension) fixed with left side hinges and cable terminals with one number 6 Amp SP MCB fixed to pole with clamp nuts,bolts etc complete all as specified and directed by Engineer-in-charge. Make: Sintex Cat No :- GSJB -2817 or equivalent model of makes specified.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm 3 core 1100 volts grade complete all as specified and directed.
Supply and fixing Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB of 32 Amps capacity including all electrical connection complete all as specified and directed.
Supply and fixing Garden 08 Watt LED Light, BAMBOO new generation LED Light with non integral driver provides high quality ecomonic energy saving lighting IP65, long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs, complete all as specified and directed by Engr-in-charge. Make : Havells No :- BAMBOOBLS8WLED830PSYMTOPC (0.6M) or equivalent model of make in PHILIPS/CG
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, pipe line, cable , etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm deep as in soil complete as specified.
Removing excavated material (soil/ rock) to distance not exc 50 m and depositing where directed at a level not exc 1.5m above the starting point,complete all as specified and directed.
Fine dry river sand cushion in trenches for cable protection with a layer of sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed. Note :- Only compacted thickness will be measured and paid.
Precast concrete cable cover unreinforced, ISI marked class LV types 2 flat size 250mm x 150mm x 40mm having minimum average breaking load 200KG, complying IS:5820-1970 made of concrete used of grade M-20, laid flat in trenches over the cable with the length of concrete cover perpendicular to the direction of the cable length, adjacent / abutting each other complete all as specified.
shree chamunda enterprise
Bharat Enterprise
Vastushilp Building Designer
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .