Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹4.0 L+₹12,400 (3.23%)Rejected-Finance 8 9 BENTINCK STREET KOLKATA 700001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹4.3 L+₹48,700 (12.7%)Rejected-Finance 46C 7G EVEREST HOUSE CHOWRINGHEE ROAD MIDDLETON ROW KOLKATA 700071 | KOLKATA | KOLKATA | WEST BENGAL | 700071 | L3 | Rejected-Finance Highest bid value |
Tender Value
₹4.5 L
EMD Value
₹9,100
Closing Date
18 Sept 2020, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Deputy General Manager (M and C)
GM bldg,KTPS,Mecheda,Purba Medinipur 721137
Annual Rate Contract for Environmental Monitoring and submission of Annual Statement for KTPS, WBPDCL.
2020_WBPDC_293882_1
GM(K)/ CC/ Env / 2704 (Vol 5)/E1650
Open Tender
Support/Maintenance Service
Item Rate
365 days
KTPS, Mecheda, Purba Medinipur 721137
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹9,100
Yes
Conference Hall,GM bldg,KTPS,Mecheda
5 Jul 2021
25 Aug 2020
21 Sept 2020
25 Aug 2020
18 Sept 2020
3 Sept 2020
2 Sept 2020
180 days
Amount
Collection of samples for emission through stack/stacks of the operating unit/units of the Power Station conducting analysis (SPM, SOX, NOX all at 6% O2 correction and other necessary parameters) and submitting report etc. as per guideline / stipulation of MOEF, GOI/WBPCB/CPCB during 12(Twelve) calendar months
Sample collection for ambient air from 4 Nos. locations per month surrounding the Power Station conducting analyzing & submitting of report containing relevant parameters including PM2.5, PM10, SO2, NO2, CO, O3, NH3, Pb, C6H6, As, Bap, Ni (1 hour & 8 hour report for CO and O3 to be submitted separately) etc. all as per guidelines of MOEF,GOI/WBPCB/CPCB during 12(Twelve) calendar months.
Collection of samples not exceeding 2 (two) of dry fly ash from silo & pond ash for analyzing and submitting report etc. all as per guideline/stipulation of MoEF&CC, GOI/CEA/ WBPCB showing different parameters i.e geotechnical & engineering properties, shear & consolidation properties, physical & chemical properties along with Cadmium, Arsenic, Thallium, Nickle, Lead, Zine, Selenium, Mercury, Hexavalent Chromium (as Cr+6) on Half-yearly basis.
Monitoring of Noise Level inside the Plant from four locations such as CHP crusher house, Turbine floor, Coal Mill, Boiler Feed pump Area and Township Area and others if required etc. analyzing and submitting of report etc. as per guideline/stipulation of MOEF,GOI/WBPCB.
Collection of samples for fugitive air from 7 (seven) separate locations for analyzing & submitting of report etc. as per guideline/stipulation of MOEF,GOI/WBPCB. Parameters to be tested are: TSPM, PM10, SO2, NO2 and free available Silica on Half-yearly basis.
Collection of samples for analyzing liquid effluent water from Ash Pond “in service” and submitting report etc. as per guideline/stipulation of CEA,MOEF,GOI/WBPCB/ CPCB. Parameters to be tested are : Oil & Grease, pH & TSS ( in mg/lit. except pH) during 12 (Twelve) calender months.
Collection of sample for analyzing liquid effluent water from Drainage Pump house to Ba-pur canal & submitting report etc. as per guideline/stipulation of CEA, MOEF, GOI/WBPCB/CPCB during 12(Twelve) calendar months. Parameters to be tested are: pH, TSS, BOD, COD, O&G, Free available chlorine, Fe, Cu, Cr, PO4 and Zn ( in mg/lit. except pH) during 12 (Twelve) calender months.
Collection of liquid effluent sample from ETP for conducting, analyzing & submitting report, etc as per guideline/stipulation of CEA, MOEFGOI/WBPCB/CPCB during 12(Twelve) calendar months. Parameters to be tested are: pH, TSS, BOD, COD, O&G, Free available chlorine, Fe, Cu, Cr, PO4 and Zn ( in mg/lit. except pH) during 12 (Twelve) calender months.
Collection of nos. of sample not exceeding 2 (two) location for analyzing drinking water from Power House and Township for analyzing and submitting report etc. Parameters to be tested are: Odor, Taste, pH, TDS, Hardness (as CaCO3), Alkalinity (as CaCO3), Nitrate, Sulphate, Fluoride, Chloride, Turbidity (NTU), Arsenic, Copper, Cadmium, Chromium, Lead, Iron, Zine, Fecal Coliform (cfu) & E. Coli (cfu) (All in mg/lit. except pH), during 12 (twelve)) calendar months.
Collection of samples from ash pond effluent water, ETP outlet, intake sump & a tube oil in vicinity of ash pond location number not exceeding 1 (one) analyzing and submitting report etc. all as per guideline / stipulation of MoEF&CC, GOI/WBPCB. Parameters to be tested are: Cadmium, Arsenic, Thallium, Nickle, Lead, Zine, Selenium, Mercury, Hexavalent Chromium (as Cr+6) on Half-yearly basis.
R V BRIGGS AND COMPANY PVT LTD
Superintendence Co of India Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .