| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical | - | Rejected-Technical L5 | |
| 3 | Rejected-Technical | - | Rejected-Technical L2 | |
| 4 | Rejected-Technical | - | Rejected-Technical L6 | |
| 5 | Rejected-Technical KACHEETTI PUTHEN VEEDU PALIYODE KUNNATHUKAL ANAVOOR P O TRIVANDRUM 695124 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695124 | - | Rejected-Technical L3 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
18 Dec 2023, 3:00 pmClosed
EXECUTIVE ENGINEER
HW Division, Aruvikkara
Deposit-Minority Drinking water supply scheme 2022-23-Resolving the drinking water shortage Azhikode area of Aruvikkara Panchayath-pipeline work
2023_KWA_628179_1
45/2023-2024/HWD/DEPOSIT MINORITY
Open Tender
Civil Works - Others
Item Rate
180 days
WORK
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,760
Yes
₹50,000
Yes
31 Jan 2024
4 Dec 2023
19 Dec 2023
4 Dec 2023
18 Dec 2023
4 Dec 2023
Amount
COST OF LABOUR
15.2.2:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.9.6:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outside diameter pipes.
100.9.9:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 110 mm nominal outside diameter pipes.
100.31.1.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class I.
100.32.3:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 50mm Double Acting Air Valve.
100.60.8.1:Replacing the chocked / damaged 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing mains, up to a length of 5m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / Brass specials viz. brass ferrule, Elbow, MTA, FTA, couplers etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, safely removing & re-fixing existing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges but excluding cost of water meter and meter box and excluding charges for cutting the concrete / tarred / bituminous roads and as per the directions of the department officers
18.17.5:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore
OD241026/2022-2023:Interconnecting the existing 100mm GI pipe with newly laid110 mm with MS tee
OD241028/2022-2023:Interconnection from newly laid 110 mm pipe line to the existing branch lines 110/90/75/63 mm pvc by supplying and fixing equal Tee and connected items.cutting, earthwork excavation, bailing out ,fencing, valve operation ,fixing materials pipes and specials, etc complete all as per direction of Engineer in charge
Cost of materials
100.98.237:Supply of PVC Pipe, 10kg/cm2, 110mm Dia.
100.98.234:Supply of PVC Pipe, 10kg/cm2, 63mm Dia.
100.98.435:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Kinetic Air Valve Type DK, Size 50mm.
100.98.482:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 100mm.
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Valve chamber
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
OD241029/2022-2023:Conveying supplying and fixing CI manhole cover of dia 560 mm
Providing Booster Pump in Kummi-Azheekkodu line
OD156046/2023-2024:Supplying, erection , testing and commissioning of Submersible pump set having 5 HP, bronze LTB impeller, SS 316 shaft CI casing, bronze LTB2 necking SS 410 sleeve with electronic flow meter, soft starter with statutory preventive relays for the protection of motor and squirrel cage EF2 motor with required electrical panel board with meters and control switches, capacitors, pressure gauges etc. asper IE rules satisfying the requirements and including the cost of required inside pumping valves.
OD69356/2023-2024:Fabrication and fixing 2M column pipe using 100 mm heavy duty GIpipe with100 mm MS flnge 16 mm thick, th work including cost of material , labour charge , cost of welding rod , conveyance charge ,hire charge of plat etc complete
ANURAG INFRA MANAGEMENT (OPC) PRIVATE LIMITED
MOHANAKUMAR V
S SANIL KUMAR
Anilkumar D
M SURENDRAN NAIR
Bidder Name
Anilkumar D
M SURENDRAN NAIR
MOHANAKUMAR V
ARUNKUMAR S.O
S SANIL KUMAR
ANURAG INFRA MANAGEMENT (OPC) PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.PDF
finance_948590.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .