| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC RIO RANGRAT OLD AIR FIELD ROAD BUDAM KASHMIR PIN 190007 J K | BUDGAM | JAMMU AND KASHMIR | 190007 | ₹15.2 L Quoted ₹15.6 L | L1 | Accepted-AOC Lowest Bidder and quoted reasonable rate |
| 2 | L2₹16.8 LRejected-Finance H NO 01 MADINA BAGH MEHJOOR NAGAR NEAR HOTEL RAFADA SRINAGAR 190015 J K | BUDGAM | JAMMU AND KASHMIR | 190015 | ₹16.8 L | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹17.1 LRejected-Finance | ₹17.1 L | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹17.2 LRejected-Finance | ₹17.2 L | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹17.5 LRejected-Finance H NO 03 TULSI BAGH SRINAGAR J K 190001 | SRINAGAR | JAMMU AND KASHMIR | 190001 | ₹17.5 L | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | M/S DUTTA ENGINEERING WORKS L4 | M/s B R Constructions L3 | HARMEET TRADERS L5 | GAGAN ASSOCIATES L1 | KASHMIR FAIR DEAL SERVICES L6 | M/S ALI MOHD AND SONS L8 | AMAR MOTOR GARAGES L7 | M/S BALI CONSTRUCTIONS L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for disconnecting of electric supply from LT control panel and starter of submersible pump motor of any size, removing the pipe line connection from discharge side, lifting submersible pump motor set alongwith column pipe from bore well with the help of chain pulley block and Refixing of submersible pumping set after repair and reconnecting with existing pipe line and making electric connection with the panel board including replacement of rusted nuts, bolts, rubber gaskets and clamps including transporting to workshop and return back after repair complete all as specified and as directed by Engr-in-charge. | 3 | Each Job | 15,000 ₹45,000 | 23,500 ₹70,500 | 24,000 ₹72,000 | 22,000 ₹66,000 | 14,500 ₹43,500 | 16,500 ₹49,500 | 24,500 ₹73,500 | 23,000 ₹69,000 |
| 2.00 | M&L for Rewinding of submersible motor with PVC insulated copper wire of existing gauge after removing the old wire and insulated material, cleaning of stator slots and making good for winding all insulating material for submersible motor of capacity 5-7.5 HP including transportation cost to workshop complete all as specified and as directed by Engr-in-charge. | 1 | Each Job | 10,000 ₹10,000 | 13,500 ₹13,500 | 14,000 ₹14,000 | 12,000 ₹12,000 | 9,500 ₹9,500 | 11,000 ₹11,000 | 13,000 ₹13,000 | 13,000 ₹13,000 |
| 3.00 | M&L for Rewinding of submersible motor with PVC insulated copper wire of existing gauge after removing the old wire and insulated material, cleaning of stator slots and making good for winding all insulating material for submersible motor of capacity 10-12.5HP including transportation cost to workshop complete all as specified and as directed by Engr-in-charge. | 1 | Each Job | 12,500 ₹12,500 | 20,000 ₹20,000 | 18,000 ₹18,000 | 18,500 ₹18,500 | 12,000 ₹12,000 | 14,000 ₹14,000 | 17,000 ₹17,000 | 19,500 ₹19,500 |
| 4.00 | M&L for Rewinding of submersible motor with PVC insulated copper wire of existing gauge after removing the old wire and insulated material, cleaning of stator slots and making good for winding all insulating material for submersible motor of capacity 25-30 HP including transportation cost to workshop complete all as specified and as directed by Engr-in-charge. | 1 | Each Job | 25,000 ₹25,000 | 23,500 ₹23,500 | 25,000 ₹25,000 | 22,500 ₹22,500 | 26,000 ₹26,000 | 27,000 ₹27,000 | 21,000 ₹21,000 | 23,000 ₹23,000 |
| 5.00 | M&L for rectification of defects in external water supply installation as when required on call by this office for no water supply due to any defects in LT panels, or leakage/blockage in water supply mains/distribution line of GI Pipes or defects in control valves i.e. gate valves, ball valves, foot valves etc of 20 to 32 mm size fixed in the pipe line laid in trenches of 20 to 32 mm dia & above including leakage of pipe line of any size including required fittings such as socket, elbow, nipple, dead plug, union and other required fittings including excavation upto required depth and refilling of trenches to make the water supply installation functional round the clock complete all as specified and as directed by Engr-in-charge. | 10 | Each Job | 1,500 ₹15,000 | 1,550 ₹15,500 | 1,500 ₹15,000 | 1,200 ₹12,000 | 1,510 ₹15,100 | 1,650 ₹16,500 | 2,000 ₹20,000 | 1,500 ₹15,000 |
| 6.00 | M&L for rectification of defects in external water supply installation as when required on call by this office for no water supply due to any defects in LT panels, or leakage/blockage in water supply mains / distribution line of GI Pipes or defects in control valves i.e. gate valves, ball valves, foot valves etc of 40 to 50 mm size fixed in the pipe line laid in trenches of 40 to 50 mm dia & above including leakage of pipe line of any size including required fittings such as socket, elbow,nipple,dead plug,union and other required fittings including excavation upto required depth and refilling of trenches to make the water supply installation functional round the clock complete all as specified and as directed by Engr-in-charge. | 8 | Each Job | 2,000 ₹16,000 | 1,600 ₹12,800 | 1,300 ₹10,400 | 1,500 ₹12,000 | 1,950 ₹15,600 | 2,200 ₹17,600 | 16,000 ₹1.3 L | 1,550 ₹12,400 |
| 7.00 | M&L for rectification of defects in external water supply installation as when required on call by this office for no water supply due to any defects in LT panels, or leakage/blockage in water supply mains / distribution line of GI Pipes or defects in control valves i.e.Sluice valve, NRV, gate valves, ball valves, foot valves etc of 80 to 100 mm size fixed in the pipe line laid in trenches of 80 to 100 mm dia & above including leakage of pipe line of any size including required fittings such as socket, elbow,nipple,dead plug,union and other required fittings including excavation upto required depth and refilling of trenches to make the water supply installation functional round the clock complete all as specified and as directed by Engr-in-charge. | 5 | Each Job | 3,000 ₹15,000 | 1,600 ₹8,000 | 1,300 ₹6,500 | 1,500 ₹7,500 | 2,950 ₹14,750 | 3,300 ₹16,500 | 1,300 ₹6,500 | 1,550 ₹7,750 |
| 8.00 | M&L for rectification of defects in external water supply installation as when required on call by this office for no water supply due to any defects in LT panels, or leaka/blockage in water supply mains / distribution line of PP-R Pipes or defects in control valves i.e. gate valves, ball valves, foot valves etc of 20 to 32 mm size fixed in the pipe line laid in trenches of 20 to 32 mm dia & above including leakage of pipe line of any size including required fittings such as socket, elbow,nipple,dead plug,union and other required fittings including excavation upto required depth and refilling of trenches to make the water supply installation functional round the clock ccomplete all as specified and as directed by Engr-in-charge. | 30 | Each Job | 1,500 ₹45,000 | 1,200 ₹36,000 | 950 ₹28,500 | 950 ₹28,500 | 1,515 ₹45,450 | 1,650 ₹49,500 | 1,100 ₹33,000 | 1,150 ₹34,500 |
| 9.00 | M&L for rectification of defects in external water supply installation as when required on call by this office for no water supply due to any defects in LT panels, or leakage/blockage in water supply mains / distribution line of PP-R Pipes or defects in control valves i.e. gate valves, ball valves, foot valves etc of 40 to 50 mm size fixed in the pipe line laid in trenches of 40 to 50 mm dia & above including leakage of pipe line of any size including required fittings such as socket, elbow,nipple,dead plug,union and other required fittings including excavation upto required depth and refilling of trenches to make the water supply installation functional round the clock complete all as specified and as directed by Engr-in-charge. | 20 | Each Job | 2,000 ₹40,000 | 1,150 ₹23,000 | 900 ₹18,000 | 950 ₹19,000 | 2,500 ₹50,000 | 2,200 ₹44,000 | 1,100 ₹22,000 | 1,100 ₹22,000 |
| 9.01Notes for Sr item No 5 to 9: - (I) Minor repair either GI or PP-R (e.g. Socket, Nipple, Dead plug, Elbow,Union and other required items) shall be carried out on spot and included in the quoted rate. (II) Adequate tradesman /supporting manpower shall be deployed by contractor as and when required for maintenance of above mentioned work. The supervisor /site Engineer of the contractor will get detailed instructions by concerned AGE/JE every morning for rectification of defects. (III) Any delay in non-rectification of defetcs shall immediately be communicated to AGE/JE. (iv) Complaint register & complaints slips shall be maintained by the contractor rep. After completion of complaint, the rep of contractor shall obtained feedback and signature of user. Payment against these items shall be made after due verification of complaint register & complaint slips by JE & Engineer-in-Charge. (vii) All Electrician/ Pipe Ftr/ Plumber shall wear proper uniform. | |||||||||||
Tender Value
₹15.0 L
EMD Value
₹30,000
Closing Date
22 Jan 2026, 6:00 pmClosed
Garrison Engineer Kargil
office of GE Kargil, Pin-908121, C/o 56 APO
CA NO. GE/K-72/2025-26 - REPAIR AND MAINT OF EXTERNAL WATER SUPPLY SYSTEM AT BHIMBAT, THASGAM AND DRASS UNDER GE KARGIL
2026_MES_746809_1
CA No. GE/K-72/2025-26
Open Tender
Civil Works - Water Works
180 days
Dras
Please Refer Tender Documents
9 documents required · 9 mandatory
₹500
GE Kargil
₹30,000
28 Feb 2026
1 Jan 2026
23 Jan 2026
1 Jan 2026
22 Jan 2026
15 Jan 2026
M&L for disconnecting of electric supply from LT control panel and starter of submersible pump motor of any size, removing the pipe line connection from discharge side, lifting submersible pump motor set alongwith column pipe from bore well with the help of chain pulley block and Refixing of submersible pumping set after repair and reconnecting with existing pipe line and making electric connection with the panel board including replacement of rusted nuts, bolts, rubber gaskets and clamps including transporting to workshop and return back after repair complete all as specified and as directed by Engr-in-charge.
M&L for Rewinding of submersible motor with PVC insulated copper wire of existing gauge after removing the old wire and insulated material, cleaning of stator slots and making good for winding all insulating material for submersible motor of capacity 5-7.5 HP including transportation cost to workshop complete all as specified and as directed by Engr-in-charge.
M&L for Rewinding of submersible motor with PVC insulated copper wire of existing gauge after removing the old wire and insulated material, cleaning of stator slots and making good for winding all insulating material for submersible motor of capacity 10-12.5HP including transportation cost to workshop complete all as specified and as directed by Engr-in-charge.
M&L for Rewinding of submersible motor with PVC insulated copper wire of existing gauge after removing the old wire and insulated material, cleaning of stator slots and making good for winding all insulating material for submersible motor of capacity 25-30 HP including transportation cost to workshop complete all as specified and as directed by Engr-in-charge.
M&L for rectification of defects in external water supply installation as when required on call by this office for no water supply due to any defects in LT panels, or leakage/blockage in water supply mains/distribution line of GI Pipes or defects in control valves i.e. gate valves, ball valves, foot valves etc of 20 to 32 mm size fixed in the pipe line laid in trenches of 20 to 32 mm dia & above including leakage of pipe line of any size including required fittings such as socket, elbow, nipple, dead plug, union and other required fittings including excavation upto required depth and refilling of trenches to make the water supply installation functional round the clock complete all as specified and as directed by Engr-in-charge.
M&L for rectification of defects in external water supply installation as when required on call by this office for no water supply due to any defects in LT panels, or leakage/blockage in water supply mains / distribution line of GI Pipes or defects in control valves i.e. gate valves, ball valves, foot valves etc of 40 to 50 mm size fixed in the pipe line laid in trenches of 40 to 50 mm dia & above including leakage of pipe line of any size including required fittings such as socket, elbow,nipple,dead plug,union and other required fittings including excavation upto required depth and refilling of trenches to make the water supply installation functional round the clock complete all as specified and as directed by Engr-in-charge.
M&L for rectification of defects in external water supply installation as when required on call by this office for no water supply due to any defects in LT panels, or leakage/blockage in water supply mains / distribution line of GI Pipes or defects in control valves i.e.Sluice valve, NRV, gate valves, ball valves, foot valves etc of 80 to 100 mm size fixed in the pipe line laid in trenches of 80 to 100 mm dia & above including leakage of pipe line of any size including required fittings such as socket, elbow,nipple,dead plug,union and other required fittings including excavation upto required depth and refilling of trenches to make the water supply installation functional round the clock complete all as specified and as directed by Engr-in-charge.
M&L for rectification of defects in external water supply installation as when required on call by this office for no water supply due to any defects in LT panels, or leaka/blockage in water supply mains / distribution line of PP-R Pipes or defects in control valves i.e. gate valves, ball valves, foot valves etc of 20 to 32 mm size fixed in the pipe line laid in trenches of 20 to 32 mm dia & above including leakage of pipe line of any size including required fittings such as socket, elbow,nipple,dead plug,union and other required fittings including excavation upto required depth and refilling of trenches to make the water supply installation functional round the clock ccomplete all as specified and as directed by Engr-in-charge.
M&L for rectification of defects in external water supply installation as when required on call by this office for no water supply due to any defects in LT panels, or leakage/blockage in water supply mains / distribution line of PP-R Pipes or defects in control valves i.e. gate valves, ball valves, foot valves etc of 40 to 50 mm size fixed in the pipe line laid in trenches of 40 to 50 mm dia & above including leakage of pipe line of any size including required fittings such as socket, elbow,nipple,dead plug,union and other required fittings including excavation upto required depth and refilling of trenches to make the water supply installation functional round the clock complete all as specified and as directed by Engr-in-charge.
M&L for disconecting and servicing/Repairing of submersible pumping set of capacity 5HP to 12.5HP and making servicing, greesing, oiling, cleaning of dust, sand etc and reassembling including electric connection and making pump fully functional including testing and commissioning after repair/replacing spare parts. Note:- 1. Spare parts required for replacement shall be measured and paid separately under relevant items Sr No 10.01 to 10.13 of this schedule.
S&F in replacement GM impellers suitable for pump motor 5 HP to 12.5HP.
S&F in replacement in replacement GM Bushes suitable for pump motor 5 HP to 12.5HP.
S&F in replacement inreplacement of Neck ring suitable for pump motor 5 HP to 12.5HP.
S&F in replacement in replacement Pump motor coupling stainless steel suitable for pump motor 5 HP to 12.5HP.
S&F in replacement in replacement Key to coupling stainless steel suitable for pump motor 5 HP to 12.5HP.
S&F in replacement in replacement Thrust plate fibre and stainless steel suitable for pump motor 5 HP to 12.5HP.
S&F in replacement in replacement Cable seal rubber suitable for pump motor 5 HP to 12.5 HP.
S&F in replacement in replacement pump shaft of suitable size suitable to existing bearing/bush sizes
Supply only in replacement Bronze bush along with SS sleeve to rotor shaft suitable for pump motor 5 HP to 12.5 HP.
M&L for leth work of pump and motor shaft for pump motor 5 HP to 12.5 HP.
Supply only in replacement C.I. Bowl assembly as per sample suitable for pump motor 5 HP to 12.5 HP.
Supply only in replacement End cover both sides for submersible motor suitable for pump motor 5 HP to 12.5 HP.
Supply only in replacement T Bolt to motor suitable for pump motor 5 HP to 12.5 HP.
Supply only in replacement Housing for assembling of motor with pump suitable for pump motor 5 HP to 12.5 HP.
S&F in repairs Column pipe made of GI/Mild Steel pipe medium Grade of appropriate length 3 mtr each 50 mm dia having both end flange as per sample complete all as specified and directed.
Excavation in trenches in hard/dense soil not exceeding 1.5mtr wide and not exceeding 1.5 depth, for foundation, etc, or for shafts, wells, cesspits, manhole, pier holes etc not exceeding 10 Sq m on plan and not exceeding 1.5 m in depth and getting out, complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by Engr-in-charge.
Removal of surplus soil not exceeding 50mtr and depositing where directed at level not exceeding 1.5mtr above the starting point complete all as specified and as directed by Engr-in-charge.
Taking up or down old unserviceable GI tubing and connections including all fittings from the trenches, wall, floor etc complete all as specified and as directed by Engr-in-charge for the following:-
20 mm bore size
25 mm bore size
40 mm bore size
50 mm bore size
80 mm bore size
S&F GI water tubing medium grade, ISI marked, 20mm bore of pipe galvanised with all fittings and fixed to walls and ceilings or laid in floors/trenches complete all as specified and as directed by Engr-in-charge.
S&F GI water tubing medium grade, ISI marked, 25mm bore of pipe galvanised with all fittings and fixed to walls and ceilings or laid in floors/trenches complete all as specified and as directed by Engr-in-charge.
S&F GI water tubing medium grade, ISI marked, 40mm bore of pipe galvanised with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed by Engr-in-charge.
S&F GI water tubing medium grade, ISI marked, 50mm bore of pipe galvanised with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed by Engr-in-charge.
S&F GI water tubing medium grade, ISI marked, 80mm bore of pipe galvanised with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed by Engr-in-charge.
S&F in repairs Gun metal globe or gate valve with iron wheel head, screwed both ends, heavy duty ISI marked of 20 mm bore complete all as specified and as directed by Engr-in-charge.
S&F in repairs Gun metal globe or gate valve with iron wheel head, screwed both ends, heavy duty ISI marked of 25 mm bore complete all as specified and as directed by Engr-in-charge.
S&F in repairs Gun metal globe or gate valve with iron wheel head, screwed both ends, heavy duty ISI marked of 40 mm bore complete all as specified and as directed by Engr-in-charge.
S&F in repairs Gun metal globe or gate valve with iron wheel head, screwed both ends, heavy duty ISI marked of 50 mm bore complete all as specified and as directed by Engr-in-charge.
S&F in repairs Gun metal globe or gate valve with iron wheel head, screwed both ends, heavy duty ISI marked of 80 mm dia complete all as specified and as directed by Engr-in-charge.
S&F in repairs brass ball valves,high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed ISI marked of 20 mm bore complete all as specified and as directed by Engr-in-charge.
M&L in replacement cast iron body sluice valve, stainless steel stem, non raising wedged gates with iron wheel head, PN-1.6, as per IS-14846, including flanged joints of 80 mm bore pipe complete all as specified and as directed by Engr-in-charge.
Taking up or down old unserviceable PP-R tubing and connetions including all fittings from the trenches , wall , floor etc complete as directed.
50 mm bore size
40 mm bore size
32 mm bore size
25 mm bore size
20 mm bore size
S&F of 3 layer PP-R pipes of size 50 mm SDR 7.4 (PN16) UV stablished and antimicrobial fusion having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches/surfacrs and wall complete all as specified and as directed by Engr-in-charge.
S&F of 3 layer PP-R pipes of size 40 mm SDR 7.4 (PN16) UV stablished and antimicrobial fusion having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches/surfacrs and wall complete all as specified and as directed by Engr-in-charge.
S&F of 3 layer PP-R pipes of size 32 mm SDR 7.4 & SDR 11 UV stablished and antimicrobial fusion having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches/surfacrs and wall complete all as specified and as directed by Engr-in-charge.
S&F of 3 layer PP-R pipes of size 25 mm SDR 7.4 & SDR 11 UV stablished and antimicrobial fusion having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches/surfacrs and wall complete all as specified and as directed by Engr-in-charge.
S&F of 3 layer PP-R pipes of size 20 mm SDR 7.4 & SDR 11 UV stablished and antimicrobial fusion having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches/surfacrs and wall complete all as specified and as directed by Engr-in-charge.
S&F in repairs PP-R ball valve of size 50mm as per site requirement complete all as specified and as directed by Engr-in-charge.
S&F in repairs PP-R ball valve of size 40mm as per site requirement complete all as specified and as directed by Engr-in-charge.
S&F in repairs PP-R ball valve of size 32mm as per site requirement complete all as specified and as directed by Engr-in-charge.
S&F in repairs PP-R ball valve of size 25mm as per site requirement complete all as specified and as directed by Engr-in-charge.
S&F in repairs water flexible suction pipe of dia 75 to 80 mm, thickness 3 mm complete all as specified and as directed by Engr-in-charge.
S&F in repairs, CI foot valve of dia 75-80mm complete all as specified and as directed by Engr-in-charge.
S&F in repairs, CI foot valve of dia 100mm complete all as specified and as directed by Engr-in-charge.
M&L for Cleaning of RCC Underground/Semi underground reservoir / tank/sump to be cleaned by stoping the main incomming of water and removing the silt/sand and scrapping the internal surfaces of the tank with wire brush, removing the fungus, deposited and removing the scrap material not exceeding 100 mtr from site and washing the sump internally with bleaching powder solution including applying two coats of synthetic enamel paint including ceiling, floor complete and painting black base and writing “TANK CLEANED ON ………..” and “NEXT TANK CLEANING DUE ON ………..” complete and writing letters not less than 4” size upto 60000 Gallons capacity all as directed by EIC. Note- Any extra cost for machinary and tool required for cleaning the tank/Sump will be bear by the contractor complete all as specified and as directed by Engr-in-charge.
M&L for Cleaning of MS OH reservoir tank to be cleaned after removing/draining out, silt/residual silt and scrapping the internal surfaces of the tank with wire brush, repairing of damaged parts by welding/jointing, removal of all the fungus, deposits and washing the complete tank with bleaching powder solution complete all as specified and providing two coats of paint on internal and external surface of tank and overflow pipe using synthetic enamel paint complete and painting black base and writing “TANK CLEANED ON ………..” and “NEXT TANK CLEANING DUE ON ………..” complete and writing letters not less than 4” size for 9600 Gallons capacity all as directed by EIC.
M&L for Opening the electric induction/centrifugal motor/pump of capacity 25-30 HP and taking out the unserviceable winding wire complete and cleaning the slots, rewinding the motor with super enamelled copper winding wire of gauge same as existing gauge including all other insulating material, (i.e. cotton tap, PVC tap, PVC sleeve glass pipe, varnish) complete all as specified and as directed by Engr-in-charge.
Disconnecting the centrifugal pump and repairing the same by replacing unserviceable spare parts including lath work etc and re-assembling the same in original position and testing the pump by running of 25-30 HP pump complete all as specified and as directed by Engr-in-charge. (Note:- Spare parts required for repaired shall be measured and paid separately under relevant item of 45 this schedule)
Supply and fixind in replacement following spare parts as per sample for pumps of capacity 25-30 HP, complete all as specified and as directed Make-Kirloskar or equivalent
CI Impellor
CI casing wearing ring.
CI Split glands.
Ball bearing SKF/NBC.
Bearing Cap.
Key for impeller steel.
Impeller nut (steel).
Remetalling welding & turning of pump shaft.
Stuffing box bush.
Gland packing
Trey coupling
Opening the electric induction/centrifugal motor/pump of capacity 10-12.5 HP and taking out the unserviceable winding wire complete and cleaning the slots, rewinding the motor with super enamelled copper winding wire of gauge same as existing gauge including all other insulating material, (i.e. cotton tap, PVC tap, PVC sleeve glass pipe, varnish) complete all as specified and as directed.
Disconnecting the centrifugal pump and repairing the same by replacing unserviceable spare parts including lath work etc and re-assembling the same in original position of 10-12.5 HP pump complete all as specified and as directed. (Note:- Spare parts required for repaired shall be measured and paid separately under relevant item of 48 this schedule)
S&F in replacement following spare parts as per sample for pumps of capacity 10-12.5 HP, complete all as specified and as directed by Engr-in-charge. Make- Kirloskar or equivalent
CI Impellor
CI casing wearing ring.
CI Split glands.
Ball bearing SKF/NBC.
Bearing Cap.
Key for impeller steel.
Impeller nut (steel).
Remetalling welding & turning of pump shaft.
Stuffing box bush.
Gland packing
Trey coupling
S&F in repair submersible copper conductor cable 3 core 4 sqmm 1100 volts flat including Nylon binding wire and accessories to clamp with column pipe and connect to starter and wire should be within the PVC conduit complete all as specified and as directed by Engr-in-charge.
S&F in repair submersible copper conductor cable 3 core 6 sqmm 1100 volts flat including Nylon binding wire and accessories to clamp with column pipe and connect to starter and wire should be within the PVC conduit complete all as specified and as directed by Engr-in-charge.
S&F in repair submersible copper conductor cable 3 core 10 sqmm 1100 volts flat including Nylon binding wire and accessories to clamp with column pipe and connect to starter and wire should be within the PVC conduit complete all as specified and as directed by Engr-in-charge.
S&F in repair submersible copper conductor cable 3 core 16 sqmm 1100 volts flat including Nylon binding wire and accessories to clamp with column pipe and connect to starter and wire should be within the PVC conduit complete all as specified and as directed by Engr-in-charge.
S&F in repair MS housing clamp made of MS flat iron of size 360mmx40mmx5mm to hold 50 mm dia MS/GI column pipe at/or ground level including nut bolts and washers of suitable size complete with two coats of black bituminous paint over a coat of red oxide primer complete all as specified and as directed by Engr-in-charge.
S&F in repair MS well cap fabricated out of 6 mm thick MS Sheet having an internal threading and locking arrangement for 200 mm dia bore pipe in two pieces having 50 mm dia hole in centre with external bracket of flat iron of size 40 mm x 5 mm thick complete with nut, bolts and washers etc including painting over a coat of red oxide primer complete all as specified and as directed by Engr-in-charge.
Supply, Installation, testing and commissioning in replacement of booster pump set of cap 0.5HP, 230 volts, 1 phase, 50 Hz complete all as specified and directed by Engr-in-charge. Make- Crompton (model No- MINI-FORCE II) or Equivalent.
S&F in repair digital fully automatic star-Delta submersible starter panel suitable for 7.5 to 10HP submersible pump set with short ckt protection conforming to IS/IEC 60947-4-1 with IP protection IP-54 complete all as specified and directed. Make- Havells or any Equivalent approved make.
S&F in repair digital fully automatic star-Delta submersible starter panel suitable for 12.5 HP submersible pump set with short ckt protection conforming to IS/IEC 60947-4-1 with IP protection IP-54 complete all as specified and directed. Make- Havells or any equivalent approved make.
S&F in repair digital fully automatic star-Delta starter(ASD) suitable for 25-30 HP Motor pump set conforming to IS/IEC 60947-4-1 with IP protection IP-54 complete all as specified and directed. Make- Havells or any equivalent approved make.
S&F in repair 60mm thick closed cell elastomeric insulation 42 kg /m3 density glass wool fiber insulation with wire mess and Aluminium cover over GI/PP-R pipes complete all as specified and as directed by Engr-in-charge.
25mm bore.
32/40 mm bore.
50 to 100 mm bore.
M&L for providing tracer /antifreezing cable for GI/PP-R pipe of any size required to keep the pipe warm upto avoiding freezing complete all as specified and as directed by Engr-in-charge.
M&L for dismantling existing connections of GI pipe dia 80 mm including valves and fittings of centrifugal pumps including removal of old rusted/damaged pipes, bends, elbows, unions, flanges, supports etc. and cleaning of site complete all as specified and directed.
M&L for preparation of pump specification plate of size 0.6x0.2 meter made out of 3 mm thick acrylic plate of blue colour and writing pump specification (i.e centrifugal/monoblock), pump capacity, MES No, with white colour and grouted on wall with suitable size screw all as specified and directed. The signboard shall be fixed on wall with stainless steel clamps and screws, including all necessary hardware and supports. Edges shall be neatly finished and rounded, and layout shall be as per approved sample.The work shall be completed in all respects including materials, transportation, lettering, fixing, and finishing to the satisfaction of Engineer-in-Charge Notes: 1.Sample of signboard shall be approved prior to bulk supply.
M&L in repair of factory made retro reflective sign board 2 mm thick aluminium sheet plate of size 1200X800 mm in 40 mm bore stainless steel pipe frame incl legs with aluminium/stainless steel rivets and flats of suitable size . The plate to be provided with compurised cut directional arrows,alphabets,lines & symbols etc with white colour reflective tape with font size and thickness as directed over dennison HIP base green reflective background sheets.Top hight of the boards with legs from ground level as decided by engr in charge including embeding in PCC 1;2;4 type b-1 blocks of size 45x45x60 cm including excavation, taking out old board (any type and size) all as per sample kept in GE office and as directed by Engr in charge.
M&L for preparation of surface by removing old paint by scraping with scrap paper/ sand paper and applying two coat of synthetic enamel paint as per the existing colour on sluice valves, NRV, Pumping set etc complete all as specified and as directed by Engr-in-charge.
Note- In case the contractor fails to complete the Repair/Servicing of centrifugal /submersible pumps within the 48 Hour from the date of issue of the pump a recovery of Rs 500/- per day till 2 days and after that Rs 1000 /- per day shall be made from the contractor dues.
Note : Deduction for amount of Rs. 35097.00 as listed in Schedule 'A' Part-II (Schedule of Credit) shall be made while awarding of contract.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
Tender722526.pdf
Tender Documents • 1.17 MB
BOQ_836279.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid