Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹3.9 L
EMD Value
₹7,749
Closing Date
27 Oct 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
AE, BSSD
Suri, Birbhum
WBPHED/AE/BSSD/NIeT_02/26-27 _11
2026_PHED_5078210_11
WBPHED/AE/BSSD/NIeT_02/26-27
Open Tender
CIVIL WORKS
Percentage
20 days
Suri
Please refer Tender documents.
5 documents required · 5 mandatory
₹7,749
7 Oct 2026
7 Oct 2026
2 Nov 2026
7 Oct 2026
27 Oct 2026
7 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, laying, fiting, fixing and jointing of UPVC pipes conforming to IS:4985-2000 with latest revision and amendments, if any, with necessary UPVC/CI specials, CIDF sluice valves, as per relevant I.S. specification including labour charges for earth work in excavation in any kind of soil including mixed soil with boulder ,road sub-grade and its flanks but excluding moorum and laterite or sand stonehard arock including cutting of brick payment without damaging the existing telephone/electrical cable line etc.(in case of damage of any type of cable line during excavation, necessary damaged charges as applicable by the respaective authority will be borne by the agency in his own cost. Loading, unloading, carrying of pipes, specials, valves from the local store to work site and lowering laying of pipes specials valves carefully in trenches maintaining proper levels and alignment, jointing the pipe and specials including supplying of good quality/approved brand solvent cement(asperIS:14182-1994 including cost of all fabricated PVC fitting i.e. tees,bend, reducers, adopter etc.as per IS:101-1988 and making flange joints including supplying required quantity of nuts, bolts and rubber insertion (CIDF sluice valves will be supplied by the department free of cost) as required at site by adopting suitable method so as to facilate the maintenance of pipe line locally as per conventional method including back filling the trenches with good earth obtained from excavation of trenches including consolidation with watering in layer not exceeding 150mm thk. with maintaining an average depth of
cushion of 1.10mtr. from the top of pipe line including making interconnection with distribution pipes etc. all complete as per drawing direction and satisfaction of the E.I.C.
N.B. i) Manufacturer’s test certificate for UPVC pipe & specials to be produced before laying of pipe line. ii)3rdpartyinspectionofUPVCpipe&specialstobe doneby CEPETor (India) SGS/NTH Kolkata or as per direction of EIC as per approved vender list. iii)No part payment at any stage on account of supply of materials shall be entertained. iv)Payment will be made on actual consumption of materials.v)UPVC pipes for the works to be supplied as per approved vendor list and as per direction & satisfaction of EIC. No pipes will be allowed beyond recommendated vendor list. vi)Submission of drawing of pipe line with statement of materials consumed between node to node points against each R.A. & final bill.if so. vii) Any deviation from required clear cover of 1.10mtr.due to site adverse condition, prior permission is to be obtained from EIC and payment for such work will be made on prorate basis over the rate of entire item. viii)All pipe connection shall be completed in all respect and as per directionofEIC.DecisionofEICinthisrespectisfinal &binding.Incase of any deviation/or any left out pipe connections an amount of Rs.10,000.00 for each pipe connection will be realized/recovered from the bill. (A) Pressure Rating : Class - III (ii) Laying of pipe line including cost of pipe & fittings/specials but excluding cost of valves. a) 90 mm dia. | 65 | Mtr. | 342 | ₹22,230 |
| 2 | b) 160 mm dia. | 250 | Mtr. | 974 | ₹2,43,500 |
| 3 | Construction of different dia Sluicevalve/Airvalve/Washoutchamberin different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified] a) 80 mm. to 150 mm. dia. | 1 | Each | 11,804 | ₹11,804 |
| 4 | Providing FHTC from the existing CI/DI/UPVC/HDPE/GI/AC distribution pipeline installing 10 mm NB Gun-metal Ferrule conforming to IS2692:1989 with latest amendments of the said pipeline with supply fitting & fixing of all other accessories like saddle piece of required size to fit the existing distribution pipeline, specials, nut & bolts, rubber sheet, washers etc and supply & laying of l5mm NB PVC (Schedule80)/20mm OD HDPE {PE100, PN16)/20mm OD PPR-C {Ctass - SDR7.4/PN16} pipes upto required length with all necessary specials 1.0 metre below the ground connecting including cutting trenches in all sorts of soil and filling up trenches'as per direction of the Engineer-in-charge and upto a point just inside the premises of the household or as directed by EiC. Supply and installation of a l5mm dia. alloy iron Bib Cock (tested to 21 Kg/cm2) above 1.0 Mtr. frorn ground, an alloy stop cock of 15 with brass spindle (tested ta 21" Kg/cm2] to be fitted in a position as directed by EIC G.l pipe of TATA make {mediurn duly} of 2 metre length with all necessary continue from the end of the PVC/HDPE/PPR-C pipe and upto 1.0 m above ground within the premises of household.
Note:
1. PVC pipe shall of schedule 80 (medium duty) conlorming to ASTMD -1785 and threaded to match with Gl Pipes as per IS : 1239 (Part - I).
2. PPR'C (Poly propylene Randam copolymer) pipe shofi be 3-layer confirming to IS:15801 UV stabilised & anti-microbial fusion welded, having thermal stabitity for hot & cold water supply including all PP-R plain & brass threoded polypropylene random/fittings.
3. Rate is exclusive of supply and delivery of 10mm NB gun-metal Ferrule. Supply & laying of 15 mm NB PVC (Schedule80)/20 mm OD HDPE (PE100, PN16)/20MM OD PPR-C (cLASS-SDR7.4/PN16) pipes
a) Above 10 m upto 20m length | 15 | Each | 3,044 | ₹45,660 |
| 5 | Filling the pipe line with water, testing hydraulically as per I.S 3114-1965 (Article-6) in section of a length not exceeding 500mtr. for head of pressure as per specification including supplying installing and fixing all equipments such as diesel pump set, blank flange, pressure gauge, valve, pressure pump and all other tools and plants including drilling topping and plugging of necessary holes to pipes, blocking ends providing temporary thrust block and subsequent blocking of holes and other jointing materials and dismantling and removal of the same including disposal of water etc. all complete as per specification and direction of EIC. The rate is inclusive of cost of requisite water to be arranged by the contractor (Recovery rate of water @ Rs.10.00/m3, if contractor used water from deptt. source). B) For UPVC/HDPE Pipe a) 90 mm dia. | 65 | Mtr. | 3.6 | ₹234 |
| 6 | b) 160 mm dia. | 250 | Mtr. | 4.78 | ₹1,195 |
| 7 | Cleaning thoroughly the inner surface of pipe line including specials and valves by flushing with water and subsequently disinfection of the same pipe line by flushing again with water containing bleaching powder resulting in residual chlorine not less than 15mg/ltrs. after 24hrs. of such filling including laboratory testing of water samples obtain from the disinfested pipe line and disposal of water from the pipe line after completion of the work. The rates including of cost of requisite water to be arranged by the contractor)
(The rate of water @Rs. 10/m3 may be recovered, if the contractor used water from deptt. source). B) For UPVC/HDPE Pipe a) 90 mm dia. | 65 | Mtr. | 0.88 | ₹57.2 |
| 8 | b) 160 mm dia. | 250 | Mtr. | 1.73 | ₹432.5 |
| 9 | Add GST @18% on sum of Item No. 1 to 8 | 1 | item | - | - |
| 10 | Add Cess @1% on sum of Item No. 1 to 9 | 1 | item | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
Tendernotice_2.pdf
PDF • 0.05 MB
Tendernotice_3.pdf
PDF • 0.53 MB
BOQ_5177855.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .