Executive Engineer PHED Division Malpura
Executive Engineer PHED Division Malpura
CONSTRUCTION and COMMISIONING of 150 MM DIA 02 nos SINGLE PHASE TUBEWELL UNDER SUB DIVISION MALPURA DIV MALPURA DISTRICT TONK
2026_PHCJA_597963_1
EE PHED DIV MALPURA 99/2026-27
Open Tender
Civil Works - Water Works
Percentage
20 days
Executive Engineer PHED Division Malpura
As Per Tender Document
3 documents required · 3 mandatory
₹1,000
Executive Engineer PHED Division Malpura
₹13,929
Yes
16 Sept 2026
16 Sept 2026
24 Sept 2026
16 Sept 2026
23 Sept 2026
16 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe. | - | - | - | - |
| 2 | Nominal bore 150 mm dia. | 200 | Mtr | 615.25 | ₹1,23,050 |
| 3 | Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended
up to date of following sizes | - | - | - | - |
| 4 | 150 mm dia NB(Thickness of pipe 5.0 mm & mass of
tube 20.13 Kg/m) | 60 | Mtr | 1,638.14 | ₹98,288.4 |
| 5 | Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985. | - | - | - | - |
| 6 | 150 mm dia nominal bore of 4.8 mm thickness | 36 | Mtr | 177.12 | ₹6,376.32 |
| 7 | Supply & Installation of single phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. | - | - | - | - |
| 8 | Above 2.0 KW | 4.5 | KW | 11,059.32 | ₹49,766.94 |
| 9 | Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase up to 5 HP, comprising of DOL Starter, MCB, Indicating Light, Ammeter, Volt meter, connection plate, condensers of approved make and the panel enclosure should be made out from 18 gauge M.S. Sheet with powder coating. Panel size Height 600 mm Width 500 mm depth 250 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The operation of panel should be
suitable for on 240 Volt AC Supply. | 2 | Each | 8,482.2 | ₹16,964.4 |
| 10 | Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.26 MB
Tendernotice_2.pdf
PDF • 3.91 MB
BOQ_1060486.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .