Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-AOC | ₹2.5 L | L1 | Accepted-AOC Accepted Bidder |
| 2 | L2₹2.5 L+₹1,210.98 (0.49%)Rejected-Finance | ₹2.5 L+₹1,210.98 (0.49%) | L2 | Rejected-Finance Financially Rejected |
| 3 | L3₹2.5 L+₹1,937.33 (0.78%)Rejected-Finance | ₹2.5 L+₹1,937.33 (0.78%) | L3 | Rejected-Finance Financially Rejected |
| 4 | Rejected-Technical VILL LALPUR P O CHAKDAHA DIST NADIA PIN 741222 | CHAKDAHA | NADIA | WEST BENGAL | 741222 | - | - | Rejected-Technical Technically disualified |
Tender Value
₹2.4 L
EMD Value
₹4,842
Closing Date
25 Feb 2026, 11:30 amClosed
EXECUTIVE ENGINEER
OFFICE OF THE EXECUTIVE ENGINEER, COMMON SERVICE DIVISION, E andAM SECTOR, KMDA. UNNAYAN BHAVAN, 1st FLOOR, B- BLOCK SALT LAKE CITY, KOLKATA -700 091.
Repair and Renovation of Office Chamber of CE, E and M sector at 1st floor, L-Block, Unnayan Bhavan, Salt lake, Kol-91.
2026_KMDA_1005922_1
11/e-NIT/EE/CSD/EandAM/KMDA of 2025-2026(3rd Call), Date-12.02.2026
Open Tender
CIVIL WORKS
Percentage
60 days
Unnayan Bhawan, KMDA
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹4,842
25 May 2026
18 Feb 2026
27 Feb 2026
18 Feb 2026
25 Feb 2026
18 Feb 2026
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:4 cement mortar (a) 20 mm thick plaster 1st Floor
Removing loose scales, blisters etc. from old painted surface andthoroughly smoothening the surface to make the same suitable for receiving fresh coat of paint. 1st Floor
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In 1st Floor) (a) One Coat i) Water based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) (Two coats) ii) Standered quality
Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixed complete Medium (I.S.I. size 2)
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (Whiten cement, synthetic adhesive and grout material to be supplied by the contractor) II) With Polymerised Adhesive [6 mm thick] &epoxy grouting materials for filling joints including spacer-2 mm [Applied directly over finished artificial stone floor/mosaic etc.] B) Light Colour
Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). In 10-12 Micron thickness Annodizing film Natural white 2- track sliding window a)Bottom frame.
Top and side frame.
Shutter for all track sliding window. i) Bottom & Top member
ii) Style side member
iii) Interlock member
Supplying, fitting and fixing boiling water resistant ply conforming to IS:303-1989 bonded with phenol formaldehyde synthetic resin of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in-Charge.[excluding the cost of supporting frame work and teak wood batten/Lipping] a) In 1st floor
French polishing to wood work including preparing surface (ordinary gloss) b)On old French polished surface including complete removal of the old polish. a) In 1st floor
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 5mm thick coloured / tinted / smoke glass.
Wood work in posts, post plates, rafters, battens, truss members, purlins etc. fitted and fixed complete (excluding the cost of bolts, paints, but including the cost of nails, screws etc.) (The quantum should be corrected upto three decimals) Sal : Malayasian
Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge.The rate includes the cost of labour, adhesive and all incidental charges there of. Glossy/Matt/Suede excluding surface texture or metallic lustre. Thickness of laminate 1 mm. a)In 1st floor
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. i) 100mm. X 50mm. X 1.25mm
ii) 75mm. X 40mm. X 1.12mm.
Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete 250mm x 19mm dia. bolt.
Anodised aluminium decorative handle (hexagonal / fluted) of approed quality fitted and fixed complete. 175mm plate x 12mm dia rod x 60mm hexagonal / fluted..
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: 300mm long x 12mm dia. bolt..
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary (a) On timber or plasterd surface : Two coats (with any shade except white)
Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T 2430 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 6 mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Standard Ceiling Board (Density > 1300 Kg/m3) of size 595 mm X 595 mm, conforming IS 14862 & Type B Category III of ISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge. In 1st floor. A) False Ceiling (with 6mm thick Fibre Cement Designer Board and E-Grid T-2430).
Supplying wooden moulding slanting beat of size 37mm X 18mm (finished) of approved design to finish the joint between wooden frame of door/window with masonary in true line and level fitted & fixed with adhesive and head less pins complete as per direction of Engineer -in-charge. a) Teak wood beat
Taking out heavy iron grated door or window (jail pattern or existing) with locking arrangement after cutting out from walls and refixing the same including mending all damages.[Mending chargesto be paid separately]
Scantling upto 50mm wide and 12mm thick (chamfering or rounding) for ceiling/partion battens including fitting, fixing in position with washers, coach screws etc. complete.: (a) Ordinary teak
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal /Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Add @ 18 % GST on Sl. No. 1 to 24.00
Add @ 1 % CESS on Sl. No. 1 to 25.00
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.84 MB
BOQ_2467524.xls
BOQ • 0.36 MB
KMDA_Form_No1.pdf
Tender Documents • 1.17 MB
SpecialTC.pdf
Tender Documents • 0.67 MB
AffidavitDeclaration.pdf
Tender Documents • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .