Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC H NO 30 2 83 WARD NO 18 PRASHANTH NAGAR COLONY NEW PALVANCHA BHADRADRI KOTHAGUDEM DISTRICT TELANGANA 507115 | BHADRADRI KOTHAGUDEM | TELANGANA | 507115 | L1 | Accepted-AOC L1 STATUS | |
| 2 | L2₹33.7 L+₹2.5 L (8.15%)Rejected-AOC A7 1 3 HWPM COLONY ASWAPURAM 507116 BHADRADRI KOTHAGUDEM DIST TELANGANA | ASWAPURAM | BHADRADRI KOTHAGUDEM | TELANGANA | 507116 | L2 | Rejected-AOC L2 STATUS | |
| 3 | Rejected-Technical H NO 1 77 1 VIJAYANAGARAM COLONY KONDAIEGUDEM POST MANUGURU 507117 BHADRADRI KOTTAGUDEM DIST TELANGANA STATE | BHADRADRI KOTHAGUDEM | TELANGANA | 507117 | - | Rejected-Technical Technically Not Qualified as per E NIT Conditions |
Tender Value
₹31.9 L
EMD Value
₹63,780
Closing Date
10 Apr 2025, 6:45 pmClosed
General Manager, HWP(M).
General Manager, HWP(M).
Maintenance of Split A/Cs, Window A/C, Water Cooler, Refrigerators and Hospital Package A/c Units in HWP (M) colony for 2 years.
2025_HWB_855413_1
HWPM/Col/Elect/AC/2025/NIT, Dt.02.04.2025.
Open Tender
Electrical Works
Item Rate
730 days
HWP(M) Colony. Aswapuram.
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹63,780
9 Jul 2025
3 Apr 2025
17 Apr 2025
3 Apr 2025
10 Apr 2025
3 Apr 2025
3 Apr 2025 - 7 Apr 2025
Amount
Maintenance of 1.5 TR Window ACs
Quarterly servicing of 1.5 TR window a/c units including handling of units and attending breakdown maintenance, as per Technical specifications of tender document.
Replacement of compressor/Leak arresting and associated works including supply of freon filter, capillary and including charging of required freon gas.
Supply of 1.5 TR AW1500Q /Rotary type compressor as required as directed by EIC of the Work.(TECUMSEH/KIRLOSKER/HIGHLY or equivalent) new compressor as required as per specification
Dismantling ,Shifting, Installation, testing and commissioning of Window A/Cs from one location to another location in case of emergencies as per specifications, as directed by EIC.
Maintenance of Water Coolers/ Bottle Coolers / Deep Frezeers.
Monthly Servicing of water cooler/bottle cooler/deep freezers including cleaning of tank inside and out side once in a week with suitable cleaning agent and including breakdown maintenance noticed if any during the servicing as required and as per specifications.
Replacement and installation of compressor/ leak arresting of freon gas and associated works including supply of freon filter, capillary, freon gas, and charging of gas.
Supply and installation of 230V/50Hz/Single Phase 4 legs Compressor model No: KCE-461 HAE/ or any equivalent for water Coolers as per technical specifications, as directed by EIC.
Supply & installation of following suitable new parts for 1.5 TR window ACs/ water coolers/Bottle coolers/ Fridges. As per specification and as directed by EIC. as follows
Starting Capacitor metallic G.C / NIKCON AS PER IS-2993(FIRE PROOF)OR Equivalent make asper specification as required.
Running Capacitor metallic G.C / NIKCON AS PER IS-2993(FIRE PROOF)OR Equivalent make asper specification as required.
Over load protector SRIRAM/Tecumseh or equilent make asper specification as required.
Thermostat danfoss / Ranutral make or equivalent make.
Starting relay asper specification as required.
Capacitor for Fan Motor metallic as per specification as required.
Knobs for thermo start/grill fixing etc. As per specifications as required.
Fan motor including capacitor. Two Rubber bushes and fixing clamps suitable for 1.5TR window ac, 95 W ,1- Ph, 50Hz, 920 RPM. American Universal or equivalent make.asper specification as required.
Condenser fan blade for window a/c asper specification as required.
Cooling air blower for Window a/c asper specification as required.
Rotary switch for window a/c.asper specification as required.
Air filter synthetic type for window a/c as per specification as required.
Window a/c front grill make pacific/Accent or metalic equivalent asper specification as required.
Fan motor including capacitor .Two rubber bushes and fixing clamps suitable for water cooler/bottle cooler /deep freezer.65 Watts,920 RPM,1 Phase,50 HZasper specification as required.
Condenser Fan blade matalic suitable for water cooler asper specification as required.
Stainless steel water taps suitable for water coolers.(Top push type asper specification as required).
Gasket for Top cover of Water Cooler/ Fridge Door suitable etc. asper specification as required.
One meter 2” PVC pipe with clamp for water cooler asper specification as required.
Float valve (complete set) for water cooler asper specification as required.
Wooden frame supply and fixing for window a/c unit asper specification as required.
Condenser suitable for up to 120 lit per hour water cooler
1/ 2” PVC pipe with clamp to connect water tap of water cooler asper specification as required.
Complete new remote control kit (Mother Board, Power unit, Remote set etc.) with cells asper specification as required for Window A/c.
Evaporator indoor Coils for 100 to 300 Ltrs. Fridges as per specificaltions as directed by EIC.
Water Cooler 1mm thickness Total Body (4 sides) with Bottm sheet 2mm thickness GI Sheet, suitable legs as required and as per specifications by EIC.
Spray painting of following type of units are as per specifications and instructions of EIC including supply of paint and all consumables.
Window a/c units including outer shell and supports asper specification as required.
Water coolers/bottle coolers/deep freezer,and Refrigirators asper specification as required.
split ac out door unit including stand,cover asper specification as required.
Maintenance of 1.5 / 2.0 / 3.0 TR Split ACs
Quarterly Servicing of 1. 5/2.0/ 3.0 TR, Split a/c units by attending maintenance as per specifications including attending breakdown maintenance as required as specified by EIC.
Replacement of compressor/Leak arresting and associated works for Split AC 1. 5/2.0/ 3.0 TR including supply of freon filter, capillary and freon gas including charging of freon gas.
Existing Split a/c units removing as directed by EIC.
Split a/c unit fixing at other location as directed by EIC.
Supply & instllation of following spare parts for 1.5/2.0/3.0TR Split ACs As per specification as directed by EIC.
Insulation with tape for 1/2 & 3/4 inch copper pipes
Air filter synthetic type for Split AC Indoor unit asper specification as required.
AAA size 1.5Volts, Alkaline non rechargable batteries
Blower as required as per specification .
Condenser Fan Blade as per specification as required.
Suction and Discharge Valves for above as per specification as required.
Blower Motor suitable for split a/c upto 3.TR capcacity unit. 230 volts, 50 hz a.c.
Condenser Fan Motor suitable for split a/c upto 3 TR capacity unit. 230 volts, 50 Hz A.C as per specification as required.
Suitable bearing for condenser / blower motor asper specification as required.
1.5 /2.0/3.0TR sensor coil make Voltas/Godrej/ LG or any equvalant as per EIC.
Copper pipe ( 1/2 " to 5/8 " ) suitable for split A/C suction and discharge asper specification as required.
New split A/c complete kit upto 1.5 Tr capacity with copper condenser, copper pipes of reputed standard make, refrigrent R410A/R32 or equivalent eco friendly gas, 5 STAR rating with 1 year warranty, as required and as directed by EIC.
Compressor suitable to upto 1.5/2.0 TR Split AC
Condensor Copper Coil for suitable up to 1.5/2TR Split Acs as per EIC
Evaporator Coil for suitable up to 1.5/2.0 TR Split Acs
Complete AC remote control kit (elctronic card, power unit, remote set etc.) with cells asper specification as required for Split AC.
Mainteance of 100 To 300 Lts. Refrigirators
Quarterly servicing of Refrigirators such as cleaning inside and outside,attending the operation checks like functioning of themostat relay, Door light etc. including handling of units and attending breakdown maintenance, as per specifications of tender document.
Replacement of compressor/Leak arresting and associated works including supply of freon filter, capillary and including charging of freon gas.
Supply of Rotary/Reciprocating type Compressor as required as directed by EIC of the Work.(TECUMSEH/KIRLOSKER/HIGHLYor equivalent) new compressor as required as per specification
Supply of PVC trays for 100 ltr to 340 ltr refrigirator
Voltas make AC Package Units at HWP(M) Hospital
Quarterly servicing of each unit, out of 3Nos. (1No 6.75 TR and 2Nos. 5.5 TR) Voltas make model 51005-D/50BB008-TR A/C package units at HWP(M) colony Hospital,
Overhauling of the compressor after disconnecting from its refrigeration & electrical circuit, Note: All the required material Tools & tackles for the above work are under the scope of the contractor including supply of freon gas. But Nitrogen gas will be supplied by the Department.
Re-winding of Condenser motor operating on 3phase, 415 volts, 50 HZ, AC power supply up to 3HP capacity,
Supply for topping up of Freon R22/32/R410A or equivalent eco friendly gas to the required level against the observation/occurance low pressure during the normal course of operation.
Supply & Replacement of new following spares for Window ACs, Water Coolers, Split ACs & Refrigirators. As per specification as directed by EIC. as follows (supplied by controctor scope)
16A double pole mcb with pvc encloser as per market price (Legrand/Goldmedal/Anchor & Havells).
16A plug tops (Havells/Orient & Goldmedal).
6A plug tops (Havells/Orient & Goldmedal).
Red & Black colour 2.5sq.mm copper flexible wire (Havells/Polycab & Goldmedal).
Green colour 1.5sq.mm copper flexible wire (Havells/Polycab & Goldmedal).
Supply and installation of 11Kv/110V,3PH 3L, DRAWOUT TYPE VT, SEC- 110V AC, STAR/STAR, BURDEN&ACCCLASS-100VA/Cl 0.5, VOLTAGE FACTOR-1.2 CONT&1.9 FOR 30 SECONDES, BIL-35KV/75KVP
M/s YAKUB BABA CONTRACTOR (BID ID -3200385)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .