| 1 | L1₹2.5 CrAccepted-AOC | ₹2.5 Cr | L1 | Accepted-AOC Tender awarded to M S Ruchira Associates C233 CEEC for Rs 24680202.5 being the lowest tenderer and rates are reasonable. |
| 2 | L2₹2.5 Cr+₹6.9 L (2.79%)Rejected-Finance | ₹2.5 Cr+₹6.9 L (2.79%) | L2 | Rejected-Finance Being other than the Lowest tenderer |
| 3 | L3₹2.5 Cr+₹7.8 L (3.15%)Rejected-Finance MIG 76 DR NO 39 33 146 2 3 MADHAVADHARA VUDA COLONY VISAKHAPATNAM 530 018 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530018 | ₹2.5 Cr+₹7.8 L (3.15%) | L3 | Rejected-Finance Being other than the Lowest tenderer |
| 4 | L4₹2.8 Cr+₹30.9 L (12.5%)Rejected-Finance | ₹2.8 Cr+₹30.9 L (12.5%) | L4 | Rejected-Finance Being other than the Lowest tenderer |
| 5 | L5₹2.8 Cr+₹36.9 L (15.0%)Rejected-Finance | ₹2.8 Cr+₹36.9 L (15.0%) | L5 | Rejected-Finance Being other than the Lowest tenderer |
Tender Value
₹3.4 Cr
EMD Value
₹4.2 L
Closing Date
2 Jun 2020, 6:00 pmClosed
Commander Works Engineer 2 Visakhapatnam
Commander Works Engineer 2 ,Chief Engineer Navy Visakhapatnam Complex, Station Road, Visakhapatnam, 530004
PROVISION OF MOTORABLE ROAD ALONG WITH BOUNDARY WALL OF INS KALINGA BHEEMUNIPATNAM
2020_MES_334629_2
82455
Open Tender
Civil Works - Roads
Item Rate
365 days
GE Kalinga
Class A cat a i and b i
6 documents required · 6 mandatory
₹2,000
Yes
GE kalinga
₹4.2 L
Yes
16 Jun 2020
8 Apr 2020
5 Jun 2020
8 Apr 2020
2 Jun 2020
6 May 2020
8 Apr 2020 - 15 Apr 2020
Amount
M&L Rolling and consolidation of formation of surfaces in cutting with power roller exc 8 tonne & n.exc 12 tonne complete all as specified and directed.
M&L Moorum /red bajri filling under floors or pavings,laid in layers n.exc 15 cm thick, spread, rolled and consolidated to gradient and camber required, complete all as specified and directed.
M&L 100 mm spread thickness moorum /red bajri filling spread, rolled and consolidated to gradient and camber required, with hand roller 0.20 to 0.50 tonne capacity complete all as specified and directed.
M&L for soling (or sub base) of 150 mm spread thickness with broken boulders or quarried stone, of granite/basalt/trap interstices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified.
M&L for 250 mm thick in two layer of 125 mm thick each layer (compacted thickness) WMM (Wet Mix Macadam), including the premixing the material with water at OMC in mechanical mix plant,carriage of mixed material by tipper to site laying in unifor layers with paver/grader/manual in sub base/base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete all as per MORTH specification,as specified and as directed.
M&L Preparing un surfaced WMM road surfaces by brushing with wire brushes for removing caked mud etc., sweeping with brooms and finally fanning the clearned surface with gunny bags to remove all loose dirt etc,complete all as specified and directed.
M&L Applying evenly a priming / tack coat with paving bitumen VG -30 at 10 Kg per 10 Sqm complete all as specified.
M&L Premix bituminous macadam 50mm consolidated thickness with 4% binder content by weight of total mix,laid/rolled and compacted to required gradient and camber using paving bitumen of grade VG-30 complete all as per MORTH specifications,as specified and as directed. Note : Premix bituminous mecadam shall be laid by using mechanical paver and mixing in hot mix plant.
M&L Preparing black top surfaces of road by brushing with wire brushes for removing caked mud etc., sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc complete all as specified and directed.
M&L Applying evenly a priming / tack coat with paving bitumen VG -30 at 5 Kg per 10 Sqm complete all as specified.
M&L for laying 40 mm consolidated thickness bituminous premix semi dense asphaltic concrete with 5.5% binder content with paving bitumen VG-30 by weight of total mix, rolled and compacted to required camber and gradient by using hot mix plant and mechanical paver equipment complete all as specified and directed.
M&L for road marking strips, lines, dashes, arrows, letters etc., of 2.5 mm thick (reflective type) on new surfaces of road / pavements and the like including and exceeding 10 cm wide with hot thermo plast material @ 5Kg/ sqm of white or golden yellow, by fully automatic thermoplastic paint applicator machine, fitted with profile shoe, glass beads dispenser, propane tank heaters and profile shoe heater etc., driven by the skilled operator on road surface complete all as per MORTH specifications and as directed.
S&F Dual directional reflective cat eye (Road Glow sutd) of impact resistant ABS plastic 100 x 90 x 16 mm of ultra voilet resistant yellow colour, having micro prismatic / cube corner reflectors suitable for fixing with epoxy / bitumen adhesive as per manufacturer's specification / instructions complete all as specified and as directed. Make: Protek/Swarflex/Greenlite [Note : Appropriate epoxy adhseive on the road surface shall be provided as per manufacturers specifications / instructions before fixing the cat eye and the same is deemed to be included in the unit rate quoted. ]
Surface excavation n.exc. (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified.
Excavation in over areas, not exc 1.5 m deep and getting out in soft / loose soil complete all as specified.
Excavation in over areas, exc 1.50 m deep but not exc 3.0 m deep and getting out in soft / loose soil complete all as specified.
Excavation in trenches, not exc 1.5 m wide & not exc 1.5 m in depth; for foundation, laying of cables etc, getting out in soft / loose soil complete all as specified.
All as per Item No.17 above but,exc 1.50 m deep & not exc 3.0 m in depth complete all as specified.
Excavation in trenches, not exc 1.5 m wide & not exc 1.5 m in depth; for foundation, laying of cables etc, getting out in hard /dense soil complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified
Removing excavated meterial to a distance not exc.50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
Removing excavated meterial to a distance exc.250 m but not exc.500m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
Removing excavated meterial to a distance exc.1.50 Km but n.exc 5 Km and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
M&L Loose filling with aggregate (broken stone or boulders) of guage 40 to 80 mm,deposited,spread and levelled and rammed to a true surface complete all as directed.
M&L Loose filling with broken bricks, n.exc 63 mm deposited,spread and levelled in layers n.exc 15 cm thick,watered and rammed to a true surface complete all as specified.
M&L Loose filling with aggregates (broken bricks) of guage 80 to 150 mm,deposited,spread and levelled in sokage wells/pits,etc complete all as directed.
M&L Hard core of broken stones broken to gauge not exceeding 63 mm deposited, spread and levelled in layers not exc 15 cm thick watered and rammed to a true surface complete all as specified.
M & L Moorum and coarse sand mix with (1:1) ratio and filling as in RWH pits, deposited,spread and levelled and rammed to a true surface complete all as directed.
M & L River sand as filling in RWH pits, deposited, spread and levelled and rammed to a true surface complete all as directed.
M&L PCC (1:4:8) type D2(using 40mm graded stone aggregate) as in foundation, filling in mass concrete complete all as specified.
Demolition of cement concrete (un reinforced) of any description and in any postion not otherwise specifically provided for including removing rubbish off the premises complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any postion not otherwise specifically provided for including removing rubbish off the premises complete all as specified and as directed.
M&L for RCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs and the like complete all as specified.
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings, and similar work not exceeding 200mm thick [horizontal or sloping] including fair finished surfaces complete all as specified.
M&L for Precast RCC (1:2: 4) type B1 (using 20 mm graded stone aggregate) as in cover slabs for manholes and set in CM 1:4 including use and waste of form work complete all as specified.
M&L for precast cement concrete (1:2:4) type B-1, (using 20 mm graded stone aggregate) as in lintels up to 1.50m span,kerb stone, window or door cills, lintles, bressumers, steps, quoin blocks (for use with masonry) string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling) corbles, brackets etc., (of any section indicated) with plain fair faces, including chamfers, weatherings, throating, etc., and setting in cement mortar 1:4 complete with joints to match complete all as specified.
M&L for PCC (1:2:4) type B0 (using 12.5 mm graded stone aggregate) as in coping including weathering, slightly rounded or chambered angles and throating including use and waste of formwork complete all as specified.
M & L for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in coping including weathering, slightly rounded or chambered angles and throating including use and waste of formwork complete all as specified.
M&L for 40 mm thick PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in bed of drains,surface to be finished even and fair without using extra cement complete all as specified.
M&L for 75 mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base of path/paver block/ hardstanding complete all as specified.
M & L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment , complete all as specified and directed
M&L for mild steel TMT bars 10mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for column hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified.
Demolition of brick work or stone / boulder masonary, built in cement mortar including all quoins, arches, pillars, etc., and precast concrete articles and removing rubbish off the premises complete all as specified and as directed.
M&L Brickwork with using flyash bricks straight or curved on plan exc 6m mean radius, built in cement morter 1:6 complete all as specified.
M&L Brickwork with using flyash bricks straight or curved on plan any radius, in half brick thick walls built in cement morter 1:4 complete all as specified.
M&L for Pre-cast cement concrete block masonry with solid blocks of PCC (1:3:6) type C1 (using 20 mm graded granite stone aggregate) exc 10 cm in width and setting in CM(1:4) complete all as specified.
Demolition and breaking up drain pipes of 150 mm dia (salt glazed ware,AC or reinforced) including cement mortar and removing rubbish off the premises complete all as specified and as directed.
M&L for Concrete bed to drain pipes for 450mm dia bore with PCC (1:4:8) type D2 (using 40 mm graded granite stone aggregate) including packing under and haunching against sides of pipes after they are laid and tested complete all as specified.
M&L for Concrete bed to drain pipes for 150mm dia bore with PCC (1:4:8) type D2 (using 40 mm graded granite stone aggregate) including packing under and haunching against sides of pipes after they are laid and tested complete all as specified.
M & L for RCC hume pipe of internal dia 450 mm, class NP-2 pipes laid and jointed with collars complete all as specified.
M & L for Under ground drainage double wall corrugated HDPE pipe of internal dia 150 mm, SN4 confirming to IS 16098(Part-II),single socketed in any length laid in trenches or floors complete all as specified.
S&F 110 mm bore PVC (SWR) pipes single socketed in any length connecting to RWH pit including necessary clamps complete all as specified.
M&L for rendering 10mm thick in cement mortar 1:6 on internal wall brick / concrete surfaces, finished even and smooth without using extra cement complete all as specified.
M&L for rendering 15mm thick in cement mortar 1:6 on stone masonry surfaces, finished even and smooth without using extra cement complete all as specified.
M&L for rendering 15 mm thick in cement mortar 1:4 on PCC block wall/ brick / concrete surfaces, finished even and smooth without using extra cement complete all as specified.
M&L for preparation of new plasterd surfaces of walls and applying three coats of white wash complete all as specified.
M & L for natural river sand as cushioning of cables, including spreading and punning down complete all as specified and directed by Engineer in charge. Note : punned thickness shall be measured for payment purpose
M&L Common burnt clay building bricks,sub class B of size 230x115x75 mm for cable protection complete all as specified.
M & L for GI Pipe 50 mm bore ( light grade) with all fittings laid in wall/road crossing/fixed to poles for protection of cable complete all as specified.
Supply, lay, test & commissioning of FRLS XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 4 core, 16 sq mm, complete all as specified and directed.
Supply, lay, test & commissioning of FRLS XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 3.50 core, 35 sq mm, complete all as specified and directed.
Supply, lay, test & commissioning of FRLS XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 3.50 core, 70 sq mm, complete all as specified and directed.
Supply, lay, test & commissioning of FRLS XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 3.50 core, 90 sq mm, complete all as specified and directed.
Supply, lay, test & commissioning of FRLS PVC insulated, sheathed, galvanized steel strip or wire armoured, electric control round cable (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 3 core, 1.50 sq mm, drawn through and including PVC rigid conduit heavy grade 20 mm dia,all fittings,clamps,etc complete all as specified. Note: one runs of 3 core 1.5 Sq.mm cable and 01 run of PVC conduit will be measured as one unit.
S&F Pre-stressed concrete poles 9.0 mtr long 102 x 172 mm at top and 102 mm x 279 mm at bottom class 10 and including apply of two coats of cement base paint over a coat of primer complete all as specified and directed.
S& F Aero dynamically designed LED street light fitting of 90 W, with pressure die cast aluminium housing,heat resistant toughened glass, IP-66 protection,prewired,inbuilt tilt arrangement with all accessories,complete all as specified and directed. Make : Crompton model HAWKI cat part No.LSTN-90-CDL-A or equivalent model in Havells/Philips/C&S.
S&F and commission solar street light with 20 watt smart integrate solar ALL-IN-ONE one street light with highest ever system efficacy LED of 170 Lum/W,MPPT charge controller,life P04 battery,monocrystalline solar panel,PIR motion sensor,easy installation with tubular pole complete all as specified, and directed by Eng-in-charge.
Solar street light system specifications: (i) Street Light : 20 W,solar LED street light range (2 days back up),highest ever system efficacy LED of 170 Lum/W,with customised lenes for proper light distribution extruded aluminium body all the components protected with IP-65 rating with 02 years warranty. Make: Crompton CSADHMP 20 CDL or equivalent model in Havells/ Philips/ Wipro/ Surya. (ii) PV Module : Mono crystalline solar PV module with positive power tolerance with efficiency > 17% for faster charging with 25 years warranty. (iii) PIR Motion sensor : Automatic dimming and brightness of light within range of 10 M (iv) (Life P04) Lithium Ferro Phosphate battery : Warranty exoected life > 5 years,inbuilt BMS for battery safety maintenance free,operating temperature of (Life P04) 10 degree to + 55 degree. (v) MPPT Solar charge controller : High efficiency >93% to charge faster type.Reverse polarity protection for battery & solar panel.Over charge and deep discharge protection for battery.Over voltage and over current protection from solar PV module.
(vi) Pole : HDG GI tubular pole of nominal bore 50mm (high grade) 9 m height with all accessories and applying 02 coats of aluminium paint over a coat of primer as specified and directed. Make: Tata/Jindal. Notes: (a) The tenderer shall opt All-in-one solar street light system from MNRE approved suppliers or manufacturers of above mentioned as approved by the GE. (b)The quoted unit rate includes earth work excavation,return filling and removal of surplus soil for poles and applying two coats of aluminium paint over a coat of primer on entire surfaces of poles as directed by Engineer-in-charge. (c) PCC foundation and coping for pole shall be measuresd and paid separately.
M&L (1:3:6) type C2 ( using 40mm graded stone aggreagate) as in foundation for poles including necessary form work complete all as specified.
M & L PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in foundation for poles including necessary form work,complete all as specified and directed .
S& F Time lite distribution board Timelite-40 A,3 Pole,230 V,digital time switch for three phase rating with contactor fitted inside steel enclosure suitable for outdoor application with IP-52 ptotection complete all as specified and directed. Make : Indo asian cat part No.TL040 DB0 or equivalent model in Havells/ C&S/L&T.
S&F HOT mouled (FRP) junction box for street light pole with locking arrangement with IP 65 protection of size 225 x 295 with 16 Amps 2 way heavy duty terminal block with 10 Amp MCB SP and two number of cable entry gland of standard size with 2 Nos suitable stainless steel bracket to fix the pole including taking down existing box complete all as specified.
M&L Earthing complete with galvanised steel earth plate electrode 600×600× 6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron wire 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point including earth work and excavtion in any type of soil, PCC 1:3:6 type C1 chamber and RCC 1:2:4 type B1 cover 40 mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for earth lead protection, 20 mm dia GI medium grade pipe for watering, water funnel, testing point etc complete all as specified and directed by Eng-in-charge and testing on completion.
S & F Galvansided iron wire 4 mm dia by means of bolts,nutscheck nuts,etc as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc., complete all as specified and directed
M&L Earthing complete with CI pipe 80 mm dia 7.5 m with flanged ends centrifugally cast,class "A" joints with suitable stainless steel bolts,nuts and sufficient slot up to 7.00 m length buried directly and preferably vertically in ground with top flanged end 0.5 m above GL,welded/connected with 32x6 mm copper conductor by means of bolts, nuts, check nuts and washers of galvanised iron including PCC 1:3:6 type C1 chamber and RCC 1:2:4 type B1 cover 40 mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI light grade pipe for earth lead protection, 20 mm dia GI light grade pipe for watering, water funnel, testing point etc and connected to earthing test point including drilling of 400 mm dia bore in any strata of soil to lower the CI pipe complete all as specified and directed by Eng-in-charge and testing on completion.
S.S.TRADERS
SVS PROJECTS
anjaliinfratech
S V S ENTERPRISES
MURALI KRISHNA ASSOCIATES
Mavee Syndicate
k.ramakrishnarao and co
Venkateswara Electricals
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .