Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹74.0 LAccepted-Finance | ₹74.0 L | L-1 | Accepted-Finance Accepted |
| 2 | L-2₹74.4 LAccepted-Finance E 60 INDUSTRIAL AREA HARIDWAR 249401 | HARIDWAR | HARIDWAR | UTTARAKHAND | 249401 | ₹74.4 L | L-2 | Accepted-Finance Accepted |
| 3 | L-3₹74.4 LAccepted-Finance 1759 SECOND FLOOR SECTOR 28 FARIDABAD 121008 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121008 | ₹74.4 L | L-3 | Accepted-Finance Accepted |
| 4 | Rejected-Technical KALSI ROAD DAKAPTHAR DEHRADUN | - | - | Rejected-Technical Disqualified |
| Sl No | Description | Qty | Unit | GOGOAL HYDRO PVT. LTD. L2 | MS Projects L1 | VM POWER AND INFRATECH L3 |
|---|---|---|---|---|---|---|
| 1.00Work | ||||||
| 1.01 | Daily Operation, monitoring and logging of all 3 (three) unit and related work including transformers, switchyard equipment, capacitor bank, DC bank etc. with all labor, material T&P etc. required for proper completion of work on daily basis. | 12 | Month | 37,89,600 ₹44,71,728 | 37,84,800 ₹44,66,064 Lowest | 38,04,000 ₹44,88,720 |
| 1.02 | Site visit of Engineer required for fault rectification of E&M equipment of plant up to the satisfaction of plant in charge including all labor T&P etc. required for completion of work. Spares shall be supplied by UJVNL
SCADA, PLC
Control, Metering and Protection Panels
ACB & SF6 Circuit Breaker
Power & Auxiliary transformers
Battery charger, UPS & Battery Bank
Lubrication oil system
Oil pressure unit.
DE & NDE bearing of generator.
Turbine & MIV
CVT 250kVA
EOT
Capacitor bank | 12 | Job | 9,12,000 ₹10,76,160 | 9,08,400 ₹10,71,912 Lowest | 9,18,000 ₹10,83,240 |
| 1.03 | Daily cleaning of all E&M equipment, Control & Protection panels, Cleaning of turbine floor, control room, Service Bay and make it oil/dust free. including all labor, material (Old dhoti, brush, detergent, WD40, degreaser etc.), T&P (Air blower etc.) required for proper completion of work on daily basis. | 12 | Month | 4,68,000 ₹5,52,240 | 4,60,800 ₹5,43,744 Lowest | 4,68,000 ₹5,52,240 |
| 1.04 | Preventive maintenance of all E&M equipment of plant on routine basis to minimize breakdown of E&M equipment by skilled manpower & maintain proper record including all labor, material T&P etc. required for completion of work. The brief description of preventive maintenance works described as given below: -
i. Greasing, lubrication of all equipment.
ii. Filtration/Dehydration of LOS & OPU oil regularly.
iii. Filtration/Dehydration of Transformer oil.
iv. Checking & maintaining oil level in LOS, OPU & Switchyard equipment.
v. Inspection of Under water parts of turbine from D/T side after dismantling of expansion joint of Unit-I, II & III (twice in a year)
vi. Checking tightness of Nut & Bolts of E&M equipment Specially LT & HT Bus bar. | 12 | Month | 9,42,000 ₹11,11,560 | 9,34,800 ₹11,03,064 | 9,30,000 ₹10,97,400 Lowest |
| 1.05 | HT & LT Breaker:- General Servicing, Repairing, Calibration and testing of 8 Nos HT Breaker (SF6) make ABB and 5 Nos LT ACB breaker make ABB by OEM Authorized person, Supply & replacement of all limit switches, complete in all respect including all men, material & all T&P required for proper completion of work. | 1 | Job | 3,49,000 ₹4,11,820 Lowest | 3,54,000 ₹4,17,720 | 3,55,000 ₹4,18,900 |
| 1.06 | General Servicing & Breakdown maintenance of 62.5kVA DG 2 (two) number 62.5 kVA DG set one at Madhyamaheshwar powerhouse (Kirloskar) and other at Jugasu Mansuna (Cummins) performed by authorized service center arranged by contractor for breakdown free operation of DG set including all labor, material, T&P etc. required for completion of work. | 3 | Job | 2,37,600 ₹2,80,368 | 2,35,500 ₹2,77,890 Lowest | 2,40,000 ₹2,83,200 |
| 1.07 | Forebay water level Transmitter, Model- CLT5-SS, Range 6M, Cable 15M, Output 4-20mA, Power supply 24VDC, 2 wire, Make- Cirrus. (As par sample) | 2 | Nos | 96,000 ₹1,13,280 | 94,000 ₹1,10,920 Lowest | 95,000 ₹1,12,100 |
| 1.08 | Pressure Transmitter range 0 to 60 bar, Output 4-20mA, Make- Gefran (As par sample) | 2 | Nos | 63,000 ₹74,340 | 60,000 ₹70,800 Lowest | 66,000 ₹77,880 |
| 1.09 | Straub OD 60.3mm, material AISI 304 (As per Sample) | 5 | Nos | 39,000 ₹46,020 | 37,000 ₹43,660 Lowest | 37,250 ₹43,955 |
Tender Value
₹74.4 L
EMD Value
₹1.5 L
Closing Date
20 Aug 2026, 3:00 pmClosed
Executive engineer (EM),
UJVN Limited, Kund Guptkashi (Rudraprayg)
Annual Operation and Maintanance of MM SHP
2026_UJVN_98075_1
05/EE(E_M_SHP)/MM/2026-27
Open Tender
Repair and Maintenance Works
Item Wise
365 days
Kund Guptkashi Rudraprayag
Please Refer Tender Document
2 documents required · 2 mandatory
₹5,900
Yes
GM (SHP), Rishikesh
₹1.5 L
Yes
25 Aug 2026
25 Jul 2026
24 Aug 2026
25 Jul 2026
20 Aug 2026
25 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | GST % |
|---|---|---|---|---|---|---|
| 1Work | ||||||
| 1.01 | Daily Operation, monitoring and logging of all 3 (three) unit and related work including transformers, switchyard equipment, capacitor bank, DC bank etc. with all labor, material T&P etc. required for proper completion of work on daily basis. | 12 | Month | - | - | 18% |
| 1.02 | Site visit of Engineer required for fault rectification of E&M equipment of plant up to the satisfaction of plant in charge including all labor T&P etc. required for completion of work. Spares shall be supplied by UJVNL
SCADA, PLC
Control, Metering and Protection Panels
ACB & SF6 Circuit Breaker
Power & Auxiliary transformers
Battery charger, UPS & Battery Bank
Lubrication oil system
Oil pressure unit.
DE & NDE bearing of generator.
Turbine & MIV
CVT 250kVA
EOT
Capacitor bank | 12 | Job | - | - | 18% |
| 1.03 | Daily cleaning of all E&M equipment, Control & Protection panels, Cleaning of turbine floor, control room, Service Bay and make it oil/dust free. including all labor, material (Old dhoti, brush, detergent, WD40, degreaser etc.), T&P (Air blower etc.) required for proper completion of work on daily basis. | 12 | Month | - | - | 18% |
| 1.04 | Preventive maintenance of all E&M equipment of plant on routine basis to minimize breakdown of E&M equipment by skilled manpower & maintain proper record including all labor, material T&P etc. required for completion of work. The brief description of preventive maintenance works described as given below: -
i. Greasing, lubrication of all equipment.
ii. Filtration/Dehydration of LOS & OPU oil regularly.
iii. Filtration/Dehydration of Transformer oil.
iv. Checking & maintaining oil level in LOS, OPU & Switchyard equipment.
v. Inspection of Under water parts of turbine from D/T side after dismantling of expansion joint of Unit-I, II & III (twice in a year)
vi. Checking tightness of Nut & Bolts of E&M equipment Specially LT & HT Bus bar. | 12 | Month | - | - | 18% |
| 1.05 | HT & LT Breaker:- General Servicing, Repairing, Calibration and testing of 8 Nos HT Breaker (SF6) make ABB and 5 Nos LT ACB breaker make ABB by OEM Authorized person, Supply & replacement of all limit switches, complete in all respect including all men, material & all T&P required for proper completion of work. | 1 | Job | - | - | 18% |
| 1.06 | General Servicing & Breakdown maintenance of 62.5kVA DG 2 (two) number 62.5 kVA DG set one at Madhyamaheshwar powerhouse (Kirloskar) and other at Jugasu Mansuna (Cummins) performed by authorized service center arranged by contractor for breakdown free operation of DG set including all labor, material, T&P etc. required for completion of work. | 3 | Job | - | - | 18% |
| 1.07 | Forebay water level Transmitter, Model- CLT5-SS, Range 6M, Cable 15M, Output 4-20mA, Power supply 24VDC, 2 wire, Make- Cirrus. (As par sample) | 2 | Nos | - | - | 18% |
| 1.08 | Pressure Transmitter range 0 to 60 bar, Output 4-20mA, Make- Gefran (As par sample) | 2 | Nos | - | - | 18% |
| 1.09 | Straub OD 60.3mm, material AISI 304 (As per Sample) | 5 | Nos | - | - | 18% |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
e-bidNIT05.pdf
Tender Documents • 1.01 MB
BOQ_115750.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].