Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance C O ANU REFRIGERATION WORKS GANDHI CHOWK PATHANKOT GANDHI CHOWK PATHANAKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | Admitted-Finance |
| 3 | Admitted-Finance 1ST FLOOR RAGHUNATH MARKET NEAR TELEPHONE EXCHANGE PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | Admitted-Finance |
| 4 | Admitted-Finance C 17 UPPER GROUND FLOOR C BLOCK COMMUNITY CENTRE JANAK PURI JANAK PURI JANAK PURI WEST DELHI DELHI 110058 | WEST DELHI | DELHI | 110058 | Admitted-Finance |
| 5 | Admitted-Finance 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | Admitted-Finance |
Tender Value
₹19.0 L
Closing Date
24 May 2021, 6:00 pmClosed
AGM Engineering Electrical
Srinagar Airport
Provision of Miscellaneous works at Kargil Airport
2021_AAI_77236_1
AAI/SNR/Engg-E/Misc./Kargil
Open Tender
Electrical Works
Works
90 days
Kargil
Please refer Tender documents.
15 documents required · 15 mandatory
₹1,180
Exempted
18 Jun 2021
13 May 2021
26 May 2021
14 May 2021
24 May 2021
14 May 2021
14 May 2021 - 19 May 2021
Amount
SITC of 2.0 TR capacity, 7000 W nominal rated cooling capacity , Hi-wall mount, Cold type, BEE rated 5 STAR Split type Air conditioner with inverter type compressor filled with R410a/ R32 gas, copper condensor tube/coil, cordless remote control for temperature adjustment, indoor unit blower speed, swing adjustment, auto restart, sleep mode, turbo mode, with LED display for temperature and other standard features suitable for operation on 230 V, 50 Hz , AC supply including wiring with suitable size FR, PVC flexible copper cable for control/power wiring, Suction and liquid line copper piping between indoor & outdoor unit (approx distance of 10 ft) as per technical specifications etc complete as required.
SITC of 2.0 TR capacity, 7000 W nominal rated cooling capacity & 8000 W nominal rated heating capacity, Hi-wall mount, Hot & Cold type, BEE rated 4 STAR minimum Split type Air conditioner with inverter type compressor having working operating temperature range (-10 degree C to 46 degree C ) filled with R410a/ R32 gas, copper condensor tube/coil, cordless remote control for temperature adjustment, indoor unit blower speed, swing adjustment, auto restart, sleep mode, turbo mode, with LED display for temperature and other standard features suitable for operation on 230 V, 50 Hz , AC supply including wiring with suitable size FR, PVC flexible copper cable for control/power wiring , Suction and liquid line copper piping between indoor & outdoor unit (approx distance of 10 ft) as per technical specifications etc complete as required ( Make - Mitsubishi Electric- Model No.MSZ-HP24VA/ O-General- Model No. ASGG24LFCD-B or equivalent model of approved make)
Supply and fitting of appropriate size and thickness of MS Stand / L-Chair for fixing outdoor unit or Condensing Units along with necessary anchor fastner/bolt & nuts etc on concrete/brick wall or floor etc. as required.
Supply & fixing of extra copper refrigerant piping and suitable size FR , PVC copper cable for control/power wiring between indooor and outdoor units for installation of above units etc as required at site.
Supply & fixing of PVC drain piping of proper dia for installation of above units as required at site beyond company provided standard length.
Supply, Installing, Testing and Commissioning of voltage Stabilizer suitable for single phase 2 TR split AC unit having stabilising input voltage range (130-300 V), Digital display showing input and output voltage, Low & High Voltage Cut-off Protection, Built In Thermal Overload Protection, wall mounting cabinet design and other standard functions including providing connections etc. complete as required.
Design, Supply , Installation , Testing and commissioning of wall mounted electric auto control room Heater panel of suitable capacity at various locations i/c bracket for wall mounting having on/off control mechanism with standard safety features and other accessories required for functioning of system suitable for working on 230 V , 50 Hz A.C supply consisting wireless receiver, high grade electrical insulation, CPRI tested as per technical specifications etc complete as required. ( Make - HECO-Model-LYNX / WALLY-Model-Sunray or equivalent model of any reputed make with approval of E.I.C )
SITC of cordless remote controller for wall mounted heating panels for switching ON/OFF, room temprature setting etc. complete as required.
SITC of floor mounted water dispenser with hot, normal and cold functions, anti corrosive durable body, cold water storage capacity - Minimum 3.0 Ltrs , hot water storage capacity - Minimum 0.9 Ltrs suitable for operation on 230 V, 50 Hz single phase AC supply etc complete as required. ( Make: USHA- Model-Laguna /VOLTAS- Model - Mimimagic or equivalent model of any reputed make)
SITC of electrical heavy duty siran for ATC tower having range of upto 1 Km, motor HP - 1/4 nominal , 8000 RPM nominal Body material - Aluminium casting, horizontal fittment suitable for working on 230 V , 50 Hz AC suppy i/c all associated wiring work etc. complete as required.
SITC of Remote Control Panel cum display Unit made out of 2 mm thick CRCA sheet totally enclosed including a visual presentation of the lighting status of 02 Nos PAPI's individually and 03 Nos spare indications using LEDs including required terminal boxes, rotary switches, toggle switches, complete wiring inside the panel with positive feedback back indication and all connections to the incoming and outgoing cables/wires suitable for operation of ON/OFF for PAPI Units etc as per technical specifications complete as required.
SITC of FAA complaint indoor type microprocessor based, air cooled constant current regulator of Thyristor control electronic type suitable for use on single phase 230V / 2-phase 400V AC + PE ± 10%, 50 Hz input AC supply with the below mentioned out put power at 6.6 amps with 5 steps variation of current output suitable for local and remote control operation with 24/48 VDC control supply complete with output current indicated on multifunction digital display, over current, over voltage, open circuit , earth fault protection and earth leakage meter, positive back indication equipments relay contactor , hours run counter along with surge protection at input and output terminals & having high altitude and sub zero temperature working capability as per technical specification of following rating: a) 4 KW MPCCR at 6.6 Amp, supply voltage 240 VAC.
Supply of 300 mm,1400 RPM heavy duty exhaust fan suitable for operation on 230 V, 50 Hz, Single phase AC supply etc, complete as required.
VOLKS ENERGIE PVT LTD
JCC ENGINEERS PRIVATE LIMITED
Anu refrigeration works
AAR PEE REFRIGERATION AND AIR CONDITIONING
Yash Energy Pvt. Ltd
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .