Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.7 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹30.0 L+₹33,366 (1.13%)Rejected-Finance PANCHKULA HARYANA 134109 | PANCHKULA | HARYANA | 134109 | L2 | Rejected-Finance L2 |
Tender Value
₹27.3 L
EMD Value
₹48,600
Closing Date
18 May 2022, 10:00 amClosed
Executive Engineer
Elect. Division HPPWD Palampur
C/O Rajeev Gandhi Govt. Engineering College Kangra at Nagrota Bagwan in Tehsil Nagrota Bagwan Distt. Kangra (HP) (SH- Providing Passive Components including cables for data, voice and video surveillance system to Electrical block) (sp. job)
2022_PWD_60500_2
Elect. Division HPPWD Palampur
Open Tender
Electrical Works
Item Rate
180 days
Nagrota Bagwan in Distt. Kangra
Please refer Tender documents.
11 documents required · 11 mandatory
₹1,500
₹48,600
19 Jul 2022
11 May 2022
18 May 2022
11 May 2022
18 May 2022
11 May 2022
Amount
Providing and drawing LAN cable Cat 6, LSZH in existing PVC conduit/ casing and capping or as required complete in all respects and to the best staisfaction of Engineer-in-charge
(Makes:- Belden /Panduit / Corning/Molex
Providing and fixing 24 Port panel - unloaded should be made of cold rolled steel, labeling strip for identification, and UL listed or as required complete in all respects and to the best staisfaction of Engineer-in-charge
(Makes:- Belden /Panduit / Corning/Molex
Providing and fixing Face plate duplex/singlex square plate, 86MMX86MM with plug in icons icon tree, write on labels in transparent plastic window- supplied with plate, should be UL listed, making connection, testing etc or as required complete in all respects and to the best staisfaction of Engineer-in-charge
(Makes:- Belden /Panduit / Corning/Molex
Supplying, Installation and fixing information outlet, shuttered, of following colours or as required complete in all respects and to the best staisfaction of Engineer-in-charge
White for Data
Blue for Voice
Red for Wifi
Yellow for Video Surveillance System
(Makes:- Belden /Panduit / Corning/Molex
Providing and patching CAT 6 patch cord UTP 0.5 meter LSZH of following colours or as required complete in all respects and to the best staisfaction of Engineer-in-charge
Grey for Data
Blue for Voice
Red for Wifi
Yellow for Video Surveillance System
(Makes:- Belden /Panduit / Corning/Molex
Providing and patching CAT 6 patch cord UTP 2 meter LSZH of following colours as required complete in all respects and to the best statisfaction of Engineer-in-charge.
Grey for Data
Blue for Voice
(Makes:- Belden /Panduit / Corning/Molex
Supplying, Installation Testing and commissioning of RJ 45 jack for VSS termination as required complete in all respects and to the best staisfaction of Engineer-in-charge.
(Makes:- Belden /Panduit / Corning/Molex
Providing and laying of Fiber optical cable Single Mode 6 core or as required complete in all respects and to the best staisfaction of Engineer-in-charge
(Makes:- Belden /Panduit / Corning/Molex
Supplying, installation, testing and commissioning of Line interface unit(LIU) for optical fiber cable 24 Port fibre Sliding enclosure,LC 6 Duplex SM Adapter plate, Blue (12 Fibre) (4 Pc),SM or as required to have end-to-end solution complete in all respects and to the best statisfaction of Engineer in Charge.
(Makes:- Belden /Panduit / Corning/Molex
Supplying, installation, testing and commissioning of splicing of Fiber Pigtails LC single mode or as required complete in all respects and to the best staisfaction of Engineer-in-charge
(Makes:- Belden /Panduit / Corning/Molex
Supplying, installation, testing and commissioning of of Fiber Patch Cord LC-LC Duplex single mode or as required complete in all respects and to the best staisfaction of Engineer-in-charge
(Makes:- Belden /Panduit / Corning/Molex
Supplying, installation, testing and commissioning of twelve Fiber LC adapter plate loaded with 6 duplex LC adaptors single mode or as required complete in all respects and to the best staisfaction of Engineer-in-charge.
(Makes:- Belden /Panduit / Corning/Molex
Providing and fixing of blanks plates for LIU or as required complete in all respects and to the best staisfaction of Engineer-in-charge
(Makes:- Belden /Panduit / Corning/Molex
FLEXIBOX 19", 9U/500MM Depth 1 SECN with front glass door cam lock, (1) PDU 6x5Aamp and 1.5meter feed cable and 3 pin plug, (1) shelf 255m, (1) Fan 203v 90 cfm, (1 )cable manager 1U pvc loops, Hardware pkt of 10 (Assembled);or as required to have end-to-end solution complete in all respects and to the best statisfaction of Engineer in Charge
Makes:- COMRACK / RITTAL / WBOX/PRESIDENT
Providing and fixing of 27 U Floor Standing ;Server Eco Rack 27U, 600/1000mm Depth with Front & Rear Perforated Door and handle lock, 1 Shelf 725mm, castors and mounting hardware packet of 20, Loops (6nos), PDU 6sockets (1) ,with RJ-45 :80;or as required to have end-to-end solution complete in all respects and to the best statisfaction of Engineer in Charge
Makes:- COMRACK / RITTAL /WBOX/ PRESIDENT
Supplying,Installation ,Testing and Commissioning of 24 Port POE Plus switch with following specification; Architecture & Port Density;Switch should offer Wire-Speed Non-Blocking Switching & Routing Performance at Layer 2 & Layer 3;Switch should have Twenty-Four (24) 1GbE PoE+ RJ45 ports and Four (4) 10GbE SFP+ Slots, from day One;Access Switch should support Stacking up to 8 Switches with more than 40 Gbps stacking bandwidth per Switch;Performance:Switching Bandwidth: Should provide Non-Blocking switch fabric capacity of 128 Gbps or more;Forwarding Capacity: Should provide wire-speed packet forwarding of 95 Mpps or more;Layer 2 features:Switch should support 4K Active VLANs;Switch should support 10K MAC addresses or more;Switch should support IP multicast snooping with support for IGMP v1, v2, v3 and MLD v1 & v2;Switch should support Jumbo Frames (up to 9K bytes);Layer 3 features:Switch should support minimum 1K IPv4 Routes or more;Switch should support Basic IPv4 and IPv6 Static Routing, ECMP, Host Routes, Virtual Interfaces, Routed Interfaces, Route Only and Routing between directly connected subnets from Day 1;Switch should support Dynamic IPv4 & IPv6 Routing protocols (OSPFv2 and OSPFv3) and Layer 3 Multicast Routing Protocols from Day 1;Security:Switch should support RADIUS, TACACS/TACACS+ and username/password for Authentication, Authorization and Accounting (AAA) with Local User Accounts and Local User Passwords;Switch should support secure communications to the management interface and system through SSL, Secure Shell (SSHv2), Secure Copy and SNMPv3;Switch should support IP Source Guard, DHCP snooping, DHCPv4, DHCPv6 and Dynamic ARP Inspection;Switch should support IPv4 and IPv6 ACLs with up to 500 rules per ACL and a minimum of 6K rules per system (Standalone Switch or Stack);Switch should support Byte and packet based broadcast, multicast, and unknown-unicast limits with suppression port dampening;Switch should support IPv6 Router Advertisement (RA) Guard;Switch should support Flexible Authentication with 802.1x Authentication and MAC Authentication;Manageability:Switch should support manageability using Network Management Software with Web based Graphical User Interface (GUI);Switch should provide Integrated Standard based Command Line Interface (CLI), Telnet, TFTP, HTTP access to switch management/monitoring;Switch should support NetFlow or sFlow or equivalent;Physical Attributes & PoE Power Budget;Mounting Option: 19” Universal rack mount ears;PoE Power Budget: The Switch should provide a minimum of 370 watts of PoE+ power;Mandatory Compliance :All categories of Switches, Transceivers & Switch OS should be from same OEM;Warranty:Switch should be quoted with TAC Support and Warranty for 3 years with NBD Hardware Replacement;Product brochure:Vendor should provide printed technical catalogs/brochures for the quoted model containing technical specifications, features or as required complete in all respects and to the best statisfaction of Engineeer-In-Chief.
Makes:- Rukus/Juniper/Cisco/ATI
Supplying, Installation Testing and commissioning of 10GB Base-LR SFP+ Uplink module, Digital Optical Monitoring (DOM) Support:yes;Max.Cable Distance:10KM;Wavelength(nm)-1260 to 1355;Supported Protocols IEEE 802.3 or as required to have end-to-end solution complete in all respects and to the best staisfaction of Engineer-In-Charge.
Makes:- Rukus/Juniper/Cisco/ATI
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:-
25 mm. dia
SPL Info Pathway Pvt. Ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .