| 1 | L1₹93.0 LAccepted-AOC 1723 GUPTA AND SONS SECTOR 39 B CHANDIGARH CHANDIGARH CHANDIGARH 160036 UDYAM CH 01 0042756 | CHANDIGARH | CHANDIGARH | 160036 | L1 | Accepted-AOC ok | |
| 2 | L2₹96.5 L+₹1.5 L (1.58%)Rejected-AOC D 89 SHASTRI NAGAR MEERUT UTTAR PRADESH PIN 250004 | MEERUT | UTTAR PRADESH | 250004 | L2 | Rejected-AOC ok | |
| 3 | L3₹97.8 L+₹2.8 L (2.92%)Rejected-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-AOC ok | |
| 4 | L4₹1.0 Cr+₹7.0 L (7.38%)Rejected-AOC 159 SHIV NAGAR MODIPURAM MEERUT 250 110 UP | MEERUT | UTTAR PRADESH | 250110 | L4 | Rejected-AOC ok | |
| 5 | L5₹1.0 Cr+₹7.8 L (8.24%)Rejected-AOC 11 CIVIL LINES ROORKEE 247667 DISTT HARDWAR UK | HARIDWAR | UTTARAKHAND | 247667 | L5 | Rejected-AOC ok |
Tender Value
₹1.2 Cr
EMD Value
₹2.0 L
Closing Date
12 Feb 2022, 6:00 pmClosed
CWE Dehradun
HQ CWE Dehradun
REPAIR/REPLACEMENT OF ROOF SHEET, CEILING, FLOORING, TILES, CUPBOARDS, ALLIED B/R WORKS AND INTERNAL ELECTRIFICATION AT GHUNGHORA CANTT UNDER GE DEHRADUN
2022_MES_499993_1
9670/DDN/E8
Open Tender
Civil Works
Item Rate
120 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
GE Dehradun
₹2.0 L
Yes
12 Mar 2022
6 Jan 2022
14 Feb 2022
6 Jan 2022
12 Feb 2022
27 Jan 2022
Amount
Dismantling of asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour as approved having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour as approved having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws and profile should match with galvalume sheet complete all as specified and as directed.
S&F 2mm thick Fiber glass reinforced translucent plain sheeting of any colour as approved fixed with coach screw and washer in roof, wall etc complete all as specified and as directed.
Dismantling of unframed timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F for mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410-W(Gde E-250) quality-A complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint on new or previously untreated steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete all as specified and directed.
M&L for providing & fixing false ceiling of designer tile ivory painted (High Pressure Steam Cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel section, galvanised @120 grams, both side inclusive and black painted groove on all T webs)
consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and cross 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable wire of 4mm dia with galvanised butterfly level clips, spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm of all 'T'' sections of 4mm dia GI wire shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, including taking down existing ceiling of any type complete all as specified and directed.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C-1 using 20 mm graded stone aggregate as in plinth protection or similar work/places, laid in alternate bays and filling the joints with & including bitumen and sand (1:3) by weight, surface finished even and fair without using extra cement complete all as specified and directed.
M&L for plain cement concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate), 75 mm thick as in sub base complete all as specified and as directed.
M&L for 40 mm thick PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in flooring, laid in alternate bays, surface finished even and smooth with using extra cement complete all as specified and directed.
M&L for 100 mm thick PCC (1:2:4) type B-2 using 40 mm graded crushed stone aggregate as in flooring, laid in alternate bays, surface finished even and smooth with using extra cement complete all as specified and directed.
M&L for factory made pre polished rubber moulded vibromatic chequred cement concrete tiles of size 30cmx30cm and 22-25mm thick, set jointed and pointed in neat cement slurry with grey cement and colour pigment to match over and including 15mm thick screed bedding layer in CM (1:6) including dismantling of old tiles complete all as specified and directed.
Demolition of stone slabs and tiles laid, bedded in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed.
M&L for 20 mm thick Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including moulding complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 15 mm thick screed bed in cement mortar 1:6 and demolition of existing floor complete all as specified and directed.
M&L for machine cut kota stone as in skirting 10-15mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 10 mm thick rendering in cement mortar 1:4 and demolition dismantling of existing skirting complete all as specified and directed.
M&L for sand filling under floors or in foundations complete all as specified and directed.
M&L for 60 mm thick pre polished rubber moulded coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658- 2006 M-35 Grade with grey cement and no pigment complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.50 mm graded stone aggregate as in leveling course to floors complete all as specified
M&L non skid/mat finish ceramic colour tiles of size 300 mm x 300 mm and 7-8 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:4 and dismantling of existing floor tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
M&L for heavy duty endura ceramic coloured tiles 10 mm thick dark shade (square/rectangular) polished area of each tiles not exceeding 0.36 sqm, in floor etc. set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 and dismantling of existing floor tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
M&L non-skid / mat finish designed coloured joint free ceramic tiles of size not less than 400 mm x 400 mm and 6-7 mm thick in floor, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed in cement mortar 1:6 and dismantling of existing tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
All as per item No 26 here in above but as in skirting including 10 mm thick rendering in cement mortar 1:4, complete all as specified and directed.
M&L for glazed ceramic colour tiles of size 300 mm x 450 mm and 6-7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 and dismantling of existing wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
M&L for vitrified ceramic coloured tiles 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floor etc. set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 and dismantling of existing floor tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
All as per item No 29 here in above but as in skirting and including 10 mm thick rendering in cement mortar 1:4.
S&F in repair aluminum alloy powder coated door made out of hollow extruded aluminum section as mentioned below. Each door having 02 Nos Disc or D type handle, 02 Nos aluminum tower bolt 200 mm size, one brass mortice lock of six lever with key in duplicate regulated by double action hydraulic floor spring heavy duty (Make:- Sandhu/Ritz)
shutter to be partly glaze with 5mm thick tined coloured glass in upper panel and partly paneled with 12mm thick both side laminated particle board in lower panel fixed with glazing clip, rubber beading/gasket, anodised aluminum beading screw complete all as specified and directed. Chowkhat Frame:- 101.60x44.45x1.60mm Shutter vertical style :- 85x44.45x1.56mm shutter middle Rail :- 83.50x44.45x1.54mm Shutter Top Rail and bottom Rail :- 114.30x44.45x1.55mm Make: (i) Anodised aluminum section : Jindal / Hindalko / Indalco. (ii) Particle board: Navipan / Puratuff / Kitlam (iii) Glass: Saint gobain / Modi guard / Tata
S&F in repair powder coated Aluminium partition (Fixed) made out of aluminium powder coated section 83 x 44.45 x 2.00 mm including 5 mm thick glass/ACP Sheet complete with rubber packing/aluminum beading etc including dismantling of existing structure complete all as specified and directed. Make: (i) Anodised aluminum section : Jindal / Hindalko / Indalco. (ii) Particle board: Navipan / Puratuff / Kitlam (iii) Glass: Saint gobain / Modi guard / Tata
S&F in repair aluminum alloy powder coated standard hollow section as mentioned below window frame (Bombay sliding) with two glazed shutter and one Nos wire gauged shutter sliding type
with aluminum sections as per Series-A (15mm) 3 track of Jindal section numbers for sliding windows, and glazed with tinted glass coloured glass 4mm thick, fixed with glazing clips, rubber beading / gasket anodised beading, screw and lock type handle of size 75mm, 2 Nos aluminum tower bolt 150mm long etc complete all as specified and directed. Shutter Top & bottom size : 37.50x15x1.60mm Shutter inner lock size 37.50x15x1.60 mm Shutter side (Handle) size 37.50x15x1.36 mm Chowkhat bottom size : 50.30x26x1.20mm Chowkhat top & sides size: 50.30x26x1.00mm. Make: (i) Anodised aluminum section : Jindal / Hindalko / Indalco. (ii) Particle board: Navipan / Puratuff / Kitlam (iii) Glass: Saint gobain / Modi guard / Tata
S&F in repair factory made 100 % solid wood plastic composite (WPC) flush type shutter of 18mm thickness one side laminate consisting of panel of PVC profile of 18mm (+ 0.7mm) thick of density 600 kg per cum manufactured by ISO-9000 certified company using for shutter cilica ply 18mm thick and fixed with frame. The thickness of shutter is edges painted by matching colour of PVC lining of plain/prelim coloured PVC sheet using etc complete as per manufacture specification.
S&F magnetic catcher 8mm dia steel ball, and brass body striking plate including letting in and fixed complete all as specified and directed.
S&F continuous (PIANO) hinges, mild steel, bright finish or electro galvanised. 30 mm width of flaps (when open) complete all as specified and directed.
S&F stainless steel barrel tower bolts 100 mm long one piece and fixed complete all as specified and directed.
S&F stainless steel handles 100 mm long one piece and fixed with screws/welded to frame, complete all as specified and directed.
S&F hasp and staple 75mm safety type, stainless steel with hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
M&L for preparation of old painted surfaces of wood & wood based material of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F in repair SS grade 204 drapery rod 20mm dia including decorative brackets, decorative finals at both ends complete all as specified and directed.
Taking down carefully copper/Aluminum point wiring (light, fan socket and power) complete including switches, ceiling rose lamp holder and regulator etc and removing from site and making good disturbed surfaces of walls/floors etc complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm. (nominal area) FRLS, single core PVC insulated 1100 Volts, grade multi stranded copper conductor unsheathed in and including new concealed PVC conduit medium duty 20 mm dia or higher and heavy grade conduit fittings and heavy duty accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.6 mm thick for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, one green colour FRLS cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and complete all as specified and directed. Note: The wiring to be done as per IE rule and maintain colour code accordingly.
One light point /bell buzzer point controlled by one-one way switch.
One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
One three pin 5 Amp socket on same board with other switches.
One three pin 5 Amp socket on independent board
One light point controlled by two way switch
All as per item No 43.04 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity conductor of size 2.5 Sqmm.
M&L for point wiring with 1.5 Sqmm. (nominal area) FRLS, single core PVC insulated 1100 Volts, grade multi stranded copper conductor unsheathed in PVC surface/ existing PVC/Steel, concealed and existing MS boxes, mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, one green colour FRLS cable of same size as earth wire up to common earth and connected to earth dolly complete all as specified and directed. Note: The wiring to be done as per IE rule and maintain colour code accordingly
One light point /bell buzzer point controlled by one-one way switch.
One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
One three pin 5 Amp socket on same board with other switches.
One three pin 5 Amp socket on independent board
One light point controlled by two way switch
All as per item No 45.04 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity conductor of size 2.5 Sq mm.
S&F switch piano flush, button type 6/5 Amp SP 250 V AC complete all as specified & directed.
S&F switch piano flush button type 15 Amps SP 250 V AC complete all as specified & directed.
S&F socket outlet multipurpose 3 Pin 5 Amp and 2 Pin 5 Amps 250 V AC complete all as specified & directed.
S&F socket outlet two in one three pin 5 Amp and 15 Amp 2 module 120 W flush type complete all as specified and directed.
S&F bell switch piano flush button type 5 Amp complete all as specified and directed.
S&F ding dong bell AC 230 V single pole complete all as specified and directed .
S&F switch piano flush button type 5 Amp SP 2 way complete 250 V AC complete all as specified and directed.
S&F step type regulator socket type double module 5 step for ceiling fan 1200/1400 mm size 230 volts 6 Amps 400 watts complete all as specified and directed.
S&F ceiling rose, 3 terminal/PVC/polycarbonate isolated body 250 V AC complete all as specified and directed.
S&F lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings including 9W LED bulb complete all as specified & directed.
M&L sub main wiring with 2 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multi stranded of size 10 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed, conduit heavy duty accessories and fittings. Insulated unsheathed FRLS cable copper conductor multi stranded of size 10 Sq. mm. as earth wire up to common earth and connected to earth dolly complete all as specified & directed.
All as per item No 57 above but cable of size 6 Sq.mm. and 6 Sq. mm. as earth wire up to common earth and connected to earth dolly complete all as specified & directed
M&L in replacement for service cable 10 sq mm twin core weather proof aluminium multi stranded conductor cable PVC sheathed PVC insulated hanging wire duly connected with earthing and clamp etc from pole to pole complete all as specified and directed.
S&F sheet metal enclosures 240 volt with 200 Amp rated bus bar for double door 8 way DB,s IP-43 IK 09 metal door suitable for one MCB SPN as incoming and 06 MCB SP as out going complete all as specified and directed.
S&F sheet metal enclosures Triple pole and neutral double door 415 Volt 4 way DBs IP-43 IK- 09 Vertical type suitable for 200 Ams rated bus bar & one MCCB 100 Amp as incoming and 12 MCB SP as outgoing complete all as specified and directed.
S&F MCB Single pole with neutral 240 Volt 10 KA 40 Amp 'B' series conforming to ISI marked complete all as specified and directed.
S&F MCB single pole and 240 volt 10 KA 5-32 Amp 'B' series conforming to ISI marked complete all as specified and directed.
S&F MCCB 415 Volt 16 KA 4 pole 63 Amp magnetic trip release & setting as incoming with fixing arrangement complete all as specified and directed.
S&F in replacement wall mounted LED tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed. Make: Philips cat part No TMC 501P1xT LED 22WP-3241(Tube Batten) and MAS LE$D 1200mm 18W-865-T-81 (Tube) / Wipro Cat part No WI0922208 (Tube Batten) LL13-181-65SE (Tube)/ Havells Cat Part No LUMILINEPLUSBS20WLED865SPCSS (Tube Batten)CRYSTAL1213T8DSTL20WLED865SGLASS(TUBE DOUBLE SIDE)
Supply, Fixing and testing LED down lighter recessed mounted 2x2 feet 36W ultra modern designed LED luminaire which provide soft light and glair free symmetrical illumination suitable for grid ceiling and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on complete all as specified and directed. Make:- Havells Cat Part no: ENDURASLIMPROPLUS2x2PLR28/36WLED 840MOD or equivalent make of PHILIPs/ CROMPTON
S&F LED light fitting 1x10 w bulk head fitting complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make:-WIPRO CAT PART NO-LW07-141-XXX-57XX or equivalent from make HAVELLS/CROMPTON
S&F in replacement LED light fitting decorative wall mounting SS brush finish fixture with frosted glass suitable for upto 1x40 watt mini glass lamp with and including one no 12 watt LED lamp. complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make Havells Cat Part NO LHFOAJE1TN1IO60 or equivalent of Bajaj/ Philips.
S&F mirror light decorative compact luminaries with decorative ends caps 9/10 Watt LED with all accessories and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make Havel’s Cat No Edge lite or equaling in Philips/Wipro
Supply and Fixing Integral LED building security light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 35/40/45 watt with efficiency 100 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours, complete all as specified and directed. Make:- Crompton model No. LSTP-45-CDL/Havells model No. ENDURAPEARLNEOSL 40WLED757PASYTOPC /Philips Cat Part No BRP409LED CW036MRFGIPSUGRand SYSKA SSK-ST-40W including taking out old unserviceable street light complete all as specified and directed.
Supply and fixing of LED tube rod 18/20 Watts single or double sided connections polycarbonate complete including making connection alteration in existing tube light fitting complete.
Disconnecting electric connection and taking down of ceiling fan / Exhaust fan removing capacitor split pins of any sweep ceiling fan / Exhaust fans complete carefully for overhauling checking of bearings/bush, cleaning the fan blades with cleaning solution, replacing the unserviceable bearing, bush, capacitor , safety split pin and nuts, bolts, washer etc duly threaded of down rods (bush, bearing, capacitor, down rod, hanging clamps, will be paid under relevant item of the Sch 'A') reassembling the ceiling fan complete after greasing/servicing, oiling testing the same making the fan in serviceable condition and refixing/ hanging the same complete all as specified and directed. Note 1: Cost of Split pins, nut bolts and threading of down rod pipe rates are included in quoted rate
Supply only fan capacitor 2.5 mfd complete all as specified and directed.
Supply only fan capacitor 3.15 mfd complete all as specified and directed.
Supply only fan capacitor 4 mfd complete all as specified and directed.
S&F standard ball bearing of ceiling fans of 1200/1400 mm sweep to suitable for different makes of fans of approved quality including necessary greasing complete all as specified and directed.
S&F bulk head gun metal suitable for ceiling fans 1200/1400 mm sweep/exhaust fan 300 to 400 mm sweep, cabin fan of any make any size complete all as specified and directed.
S&F in replacement air ventilation fan metallic body 300mm, 900 RPM, single phase, 230V AC including necessary, M&L for making hole fixing arrangement on wall with frame hold fast, bolt, washer etc including connection with twisted white three core flexible copper multi stranded conductor cable from ceiling rose to connector complete all as specified and directed. Make:- Havells cat part No. Ventil Air DXWHT, CG cat No. BRISKAIR or equivalent Orient. Note: old unserviceable fan shall be deposit in E/M yard.
S&F in replacement of 3 core PVC insulated copper cable of size 23/0.0076 multi standard in repairs complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Geyser vertical mount type 25 Ltrs capacity five star rated , shockproof and rust proof metal body compact size including two Nos PVC connection heavy duty and connecting with all fixing arrangement of nuts & bolts and fixing on wall complete all as specified & directed. Note: old unserviceable Geyser will be deposited in E/M store yard.
S&F in replacement tamper proof, electronic, single phase whole current energy meter (LCD Display) 10 Amp to 60 Amp, 240 volt class 1.03 and class 2.05 AC supply including cable connection, proper sealing with lead. The meter shall comply with the latest version of IS-13779 with at least 2 anti-tamper LED indication of line load reversal and earth loading indication including electrical connection with existing system and sealing properly including push fit type PVC box complete. The meter shall work satisfactory with guarantee accuracy as per limit of IS-13779. The meter shall be fixed on existing steel boxes on wall complete all as specified and directed. Note: Old unserviceable meter shall be deposited to E/M store yard.
Dismantling electric and water connection of the 25/50 ltr's geyser, taking down from its original position on ground, dismantling geyser complete such as removing tank from its outer body, removing apparatus plate from the tank, descaling the geyser inner tank and apparatus plate complete, testing its thermostat, heating element, and tank from leakage,
reassembling the geyser, replacement of unserviceable parts such as heating element, rubber gasket & testing the geyser and installation of the geyser into its original position and connecting all electric and water supply connection complete and testing on completion all as directed by Engineer-in-Charge. Note:- (i) Heating element & apparatus if require to be replaced shall be measured and paid separately. (ii) Nut, bolts and hold fasteners if require to be replaced shall be deemed to be included in the quoted rates of this item. (iii) All repair shall be carried out on complaint basis and measurement will be made only once through out the contract period irrespective number of repair carried out in same Geyser. (iv) All repairs shall be carried out on complaint basis, contractor shall attend the AGE E/M office daily at 9AM and collect complaint slip from concerned JE daily up to 11.00 Hrs
Supply only heating element any type/size as per site requirement of capacity 2 KW ISI Marked complete all as specified and directed.
Supply only thermostat for geyser long type 11" in length as per site requirement temp setting on 60 degree centigrade ISI Marked, long type complete all as specified and directed.
S&F in replacement chromium plated copper connecting pipe 450 mm long with threaded brass nuts and washers check nut with washer complete suitable for 15mm dia pipe along with threaded brass nuts and washers complete all as specified and directed.
S&F in replacement of water supply PVC flexible connection Nylon braided with suitable threaded check nut with washer complete suitable for hot/cold water 15mm dia along with threaded brass nuts and washers 45 cm long complete all as specified and directed.
S&F in replacement of 3 core PVC insulated copper cable of size 40/0.0076 multi standard in repairs complete all as specified and directed.
Supply only syphon assembly for geyser any type of hole (6/7/9) as per existing make & size complete all as specified and directed.
Supply only pressure release valve as per existing make and size geyser spring loaded 15 mm dia complete all as specified and directed.
Supply only rubber Gasket as per existing make/size site requirement suitable for 25/50 Ltr capacity geyser complete all as specified and directed.
S& Sheet metal enclosure SPN with a two pin and earth plug and socket complete with one 20 amp single pole MCB complete all as specified and directed.
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground end vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5 M below normal ground level connected to galvanized steel earth wire 4 mm dia by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1, cover slab 54 cm x 54 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm c/c both ways, and with one handle for lifting made out of 10 mm dia MS round bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing (light grade) for protection of earth lead connection, including necessary excavation and earth work in any type of soil and necessary testing complete all as shown on electrical plate No 3 of SSR Part –I (2009) and as directed.
MOHAN LAL GUPTA
M/s Anil Kumar
Arun Construction Co.
Alankar Traders
Som Prakash Gupta
sath sahib associates
PAWAN KUMAR
M/S SHANTI SARUP DINESH CHAND
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .