Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.2 L+₹52,025.78 (3.32%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹16.5 L+₹84,651.54 (5.40%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹17.1 L+₹1.4 L (8.98%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹17.6 L+₹2.0 L (12.5%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹17.6 L
EMD Value
₹44,090
Closing Date
25 Jul 2020, 5:00 pmClosed
EXECUTIVE ENGINEER LSGD KANNUR
EXECUTIVE ENGINEER LSGD KANNUR
MLA ADS 18-19 Sri. James Mathew MLA- Construction of waiting area for patients at Primary Health centre in Kuttyattur GP
2020_LSGD_372253_10
D/TN/1(5)/2020-21
Open Tender
Civil Works - Buildings
Item Rate
180 days
kannur
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,825
Yes
online
₹44,090
Yes
7 Sept 2020
17 Jul 2020
28 Jul 2020
17 Jul 2020
25 Jul 2020
17 Jul 2020
Amount
Building
15.23.1 : Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
15.28.1 : Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
15.19 : Dismantling steel work manually / by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per directions of Engineer -in-Charge.
15.10.1 : Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually / by mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge:In lime mortar
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
od518264/2019_2020 : Laterate masonry with neatly dressed laterate stone of size 35x20x20cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
50.2.26.1 : Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
od518300/2019_2020 : Laterate masonry with neatly dressed laterate stone of size 35x20x20cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
13.7.2 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
50.10.1 : Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
50.10.2 : Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.41.2 : Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
od512591/2019_2020 : Designing, fabricating, testing, installing and fixing in position Curtain Wall with<br>Aluminium Composite Panel Cladding, with open grooves for linear as well as<br>curvilinear portions of the building , for all heights and all levels etc. including:<br>a) Structural analysis & design and preparation of shop drawings for pressure<br>equalisation or rain screen principle as required, proper drainage of water to make<br>it watertight including checking of all the structural and functional design.<br>b) Providing, fabricating and supplying and fixing panels of aluminium composite<br>panel cladding in pan shape in metalic colour of approved shades made out of<br>4mm thick aluminium composite panel material consisting of 3mm thick FR grade<br>mineral core sandwiched between two Alumini um sheets (each0.5mm thick). The<br>aluminium composite panel cladding sheet shall be coil coated, with Kynar<br>500based PVDF / Lumiflon based fluoropolymer resin coating of approved colour<br>and shade on face # 1 and polymer (Service) coating on face # 2 as specified using<br>stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer<br>rods etc.<br>c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised<br>with serrations and serrated washers to arrest the wind load movement, fasteners,<br>SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to<br>prevent bi-metallic contacts all complete required to perform as per specification<br>and drawing The item includes cost of all material & labour component, the cost of<br>all mock ups at site, cost of all samples of the individual components for testing in<br>an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall<br>with aluminium composite panel cladding till the handing over of the building for<br>occupation. Base frame work for ACP cladding is payable under the relevant<br>aluminium item.s The Contractor shall provide curtain wall with aluminium<br>composite panel cladding, having all the performance characteristics all complete<br>, as per the Architectural drawings, as per item description, as specified, as per the<br>approved shop drawings and as directed by the Engineer-in-Charge.<br>However, for the purpose of payment, only the actual area on the external face of<br>the curtain wall with Aluminum Composite Panel Cladding (including width of<br>groove) shall be measured in sqm. up to two decimal places.
11.19.3 : Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand):Dark shade pigment using ordinary cement
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.48.3 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
13.71 : Lettering with black Japan pint of approved brand and manufacture
Shaji C P
RAMACHANDRAN. R
SANTHOSH P
M D SAJI
Bidder Name
RANJITH K P
M D SAJI
RAMACHANDRAN. R
SANTHOSH P
Shaji C P
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_527140.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .