Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 CrAccepted-AOC HSVP PANCHKULA | PANCHKULA | HARYANA | 133301 | ₹4.2 Cr | L1 | Accepted-AOC Award |
| 2 | L2₹4.9 Cr+₹65.4 L (15.4%)Rejected-AOC | ₹4.9 Cr+₹65.4 L (15.4%) | L2 | Rejected-AOC Reject |
| 3 | L3₹4.9 Cr+₹65.4 L (15.4%)Rejected-AOC RGTPP KHEDAR HISAR HARYANA | HISAR | HARYANA | 125001 | ₹4.9 Cr+₹65.4 L (15.4%) | L3 | Rejected-AOC Reject |
Tender Value
₹3.8 Cr
EMD Value
₹7.6 L
Closing Date
15 Mar 2021, 10:00 amClosed
Executive Engineer, PHED No. 1 Gohana
Executive Engineer, PHED No. 1 Gohana Near MC Park Jind Road Gohana
AUGMENTATION OF CANAL BASED WATER SUPPLY SCHEME ROLAD LATIFPUR GROUP OF 7 NO. VILLAGES ie ROLAD LATIFPUR, BHADI, MOI, MAJRI, CHITIA DEVA, REHMANA AND SATAWALI, PROVIDING BOOSTING STATIONS, FUNCTIONAL HOUSEHOLD TAP CONNECTIONS AND LAYING THE BALANCE P
2021_HRY_161389_1
EIC Memo No. 16592-PHE/Mont dt. 26-02-2021
Open Tender
Civil Works
Works
540 days
Village Rolad Latifpur Group
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
₹7.6 L
Yes
3 May 2021
1 Mar 2021
15 Mar 2021
1 Mar 2021
15 Mar 2021
1 Mar 2021
Amount
WATER TREATMENT PLANT (WTP) Design, construction, testing & commissioning of 0.50 MLD capacity Water treatment plant including inlet channel, Alum dozing, Flash mixing, Clarifloculator, filter box, over head Reservoir for back wash, waste water tank including all civil work, pumping machineries and electric cabling, control panels, entire piping network of suitable size laying the DI pipe from raw water pump to inlet box of WTP, WTP to CWT & Suction Well for CW including DI specials, suitable size Sluice valves, Hodies, manhole covers, air scour equipment, chemical house including chlorination equipment and arrangement of flow measurement and sand bed complete in all respects as per NIT (Sluice valves of make IVC/VAG) .
RAW WATER PUMPING MACHINERY Supply & Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame-WATER WORKS- 800 LPM X 12.50 M. Head
CLEAR WATER PUMPING MACHINERY-Supply & Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame- WATER WORKS - 3.1.1- 800 LPM X 40 M. Head
3.1.2- 800 LPM X 40 M. Head
3.1.3- 500 LPM X 45 M. Head
B/STN MOI - 600 LPM X 45 M. Head
B/STN MAJRI - 500 LPM X 45 M. Head
B/STN CHITIA DEVA - 400 LPM X 45 M. Head
B/STN REHMANA - 500 LPM X 45 M. Head
B/STN SATAWALI - 500 LPM X 45 M. Head
PANEL BOARDS FOR MOTORS Supply, erection, testing & commissioning of wall mounted electrical L.T. Panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900 mm and 400 mm deep having follwing items -(4.1)-For 2 no Pumping Sets of 800 LPM x 12.5 m Head a) Main switch 63 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 800 LPM x 12.5 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 2.1
(4.2)-For 2 no Pumping Sets of 800 LPM x 40 m Head a) Main switch 63 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 800 LPM x 40 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 3.1.1
(4.3)-For 2 no Pumping Sets of 800 LPM x 40 m Head a) Main switch 63 amp. 1 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 800 LPM x 40 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 3.1.2
(4.4)-For 2 no Pumping Sets of 500 LPM x 45 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 500 LPM x 45 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 3.1.3
(4.5)-For 2 no Pumping Sets of 600 LPM x 45 m Head a) Main switch 63 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 600 LPM x 45 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 3.2
(4.6)-For 2 no Pumping Sets of 500 LPM x 45 m Head a) Main switch 63 amp. 1 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 500 LPM x 45 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 3.3
(4.7)-For 2 no Pumping Sets of 400 LPM x 45 m Head a) Main switch 63 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 400LPM x 45 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 3.4
(4.8)-For 2 no Pumping Sets of 500 LPM x 45 m Head a) Main switch 63 amp. 1 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 500 LPM x 45 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 3.5
(4.9)-For 2 no Pumping Sets of 500 LPM x 45 m Head a) Main switch 63 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 500 LPM x 45 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 3.6
Sluice Valves / NRV & specials for Pumping Machinery- Supplying, fixing, jointing, testing & commissioning of DI sluice valves resilient sheet P.N. 1.6 including cost of jointing material complete in all respect. (IVC / VAG make, Kirloskar)- 100mm i/d
Supplying,fixing, testing & commissioning of DI swing check type reflux valve (non returned valve) PN 1.6 including cost of jointing material complete in all respect.( IVC / VAG , Kirloskar make) - 100mm i/d
Supply, fixing & testing of Mechanical Joints PN 1.6 alongwith ruber gaskit & galvanized nuts / bolts complete in all respect.- 100mm i/d
Supply, erection, fixing & testing of DI Double flanged pipe complete with all jointing materials- 100mm i/d
Sluice Valves/ Specials For Rising Mains & W/W - Supplying, fixing, jointing, testing & commissioning of DI sluice valves resilient sheet P.N. 1.6 as per DNIT specification on the pumping machinery & head works including cost of jointing material (IVC / VAG make)- 100 mm i/d
Supply & Fixing of Mechanical Joints PN 1.6 alongwith ruber gaskit & galvanized nuts / bolts complete in all respect.- 100 mm i/d
Supply, erection, testing & commissioning of IS marked copper wire for various motors with underground system in PVC and flexible pipes copper wire 3 core complete in all respevts with accessories like thimble etc.- 10mm 2 core
25mm2 3 Core
Supply erection testing and commissioning of exhaust fans each having a capacity of 45 cubic meters per minutes, complete in all respect.
Supply erection & testing of Ceiling fan of size 48" i/d (1200 mm) of reputed ISI make complete in all respect.
Providing and fixing of insulated Rubber matting suitable for HKV installation 1 meter x 2 meter x 12 mm as per specification.
Providing & fixing suitable size floating along with swivel bend as per required specifications approved by Engineer-in-Charge
Supply erection testing of reputed make LED light 100 wats with fittings and accessories complete in all repects. (3 at WW + 10 at 5 B/Stn)
Providing & fixing of D.I. Kinetic Air Valve soft seated as confirming to I.S.I. complete in all respect.- 80mm
Supply erection, testing & commissioning of light fittings including complete wiring alon with all material upto 10 points including switch, button, plug, PVC conduict pipe & copper wire etc. as per approved specifications. ( 5 no. pump chambers of Boosting Stations)
Supply erection testing and commissioning of Flow Meter (KRONE Make) with digital display of 150 mm i/d complete in all respect.
Design, Supply & Erection of copper wound outdoor type Transformers of required KVA as mentioned below on load tap changer of suitable capacity on higher side of standard make outdoor type, VCB Panel, G.O. Switch, H.T. Metering Panels, APFC Panels for Transformer, 11KV Substation, entire cable network from G.O. Switch to H.T. Metering equipment and from H.T. Metering to Transformer Main to L.T. Panel, Earthing, safety equipment and any other contingent thereto complete in all respect as per DNIT and getting it passed from Chief Electrical Officer including operation & Maintenance of 5 Years.- At W/W 100 KVA
Providing & fixing in position GI elbow ISI marked complete in all respect 15 mm i/d 1,238 x 4 = 4,952
Providing & fixing in position GI Nipple ISI marked complete in all respect 15mm x150mm /100 mm 1,238 x 2 = 2,476
Operation & Maintenance - Operation & maintenance for the complete scope of work mentioned in the DNIT (Disinfection material will be supplied by the PHED) as per schedule-IV during Defect liability period of 12 months after trial run period of 3 months & 5 years thereafter. (Will be charged to A/mtc estimate)." - (i) Defect liability period (Operation Only)
(ii) Operation & maintenance during 1st year
(iii) Operation and maintenance during 2nd year
(iv) Operation and maintenance during 3rd year
(v) Operation and maintenance during 4th year
(vi) Operation and maintenance during 5th year
Bidder Name
Amount
RAVI PARKASH CONTRACTOR(GSTN-06AJMPP2964K1ZN)
ROHTASH KUMAR CONTRACTOR(GSTN-NA)
NAFE SINGH CONTRACTOR(GSTN-NA)
RAVI PARKASH CONTRACTOR
NAFE SINGH CONTRACTOR
NAFE SINGH CONTRACTOR
ROHTASH KUMAR CONTRACTOR
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .