Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC 00 BEHIND COURT PHALODI NAI SARAK PHALODI JODHPUR RAJASTHAN 342301 UDYAM RJ 22 0048153 | JODHPUR | RAJASTHAN | 342301 | L1 | Accepted-AOC Lowest Bidder, Hence accepted | |
| 2 | L2₹10.8 L+₹87,760 (8.83%)Rejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L2 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 3 | L3₹13.4 L+₹3.4 L (34.3%)Rejected-Finance 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | L3 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 4 | L4₹14.2 L+₹4.3 L (43.1%)Rejected-Finance 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLAGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance Not Lowest Bidder, Hence Rejected |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
21 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Phalodi
GE (AF) Phalodi
REPAIR/MAINT OF HIGH BAY AND LOW BAY LIGHTING AT HANGAR, SUN SHELTER, DISPERSAL AREA AND CONNECTED ITEMS AT AF STN PHALODI
2022_MES_533384_1
8431/C/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Phalodi
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) Phalodi
₹30,000
Yes
1 Sept 2022
24 Jun 2022
27 Jul 2022
24 Jun 2022
21 Jul 2022
8 Jul 2022
60 days
Amount
Taking down copper/aluminium circuit/submain wiring of any size complete, including fixture and fittings through any type of conduit and removing materials to store for keeping in safe custody or for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
S&F in circuit /sub main wiring of any height in hanger recess with 4x4 sqmm single core FRLSH PVC insulated , unsheathed multistrand copper conductor cable 1100 volt grade drawn through steel conduit with 1x2.5 sqmm single core, FRLSH, PVC insulated but unsheathed copper conductor 1100 volts grade cable as earth continuity wire in hanger highbay/ floodlight complete all as specified and directed. Note:- (i) 4 lengths of 4 Sqmm and 1 length of 2.5 sqmm cable will be measured as one length. (ii) Cost of neccessary tools and plants such as ladders, hydra for repair of high raised high bay / medium bay / low bay luminaires should be deemed to be included in the unit rate quoted.
S&F in circuit /sub main wiring of any height in hanger recess with 4x6 sqmm single core FRLSH PVC insulated , unsheathed multistrand copper conductor cable 1100 volt grade drawn through steel conduit with 1x4 sqmm single core, FRLSH, PVC insulated but unsheathed copper conductor 1100 volts grade cable as earth continuity wire in hanger highbay/ floodlight complete all as specified and directed. Note:- (i) 4 lengths of 6 Sqmm and 1 length of 4 sqmm cable will be measured as one length. (ii) Cost of neccessary tools and plants such as ladders, hydra for repair of high raised high bay / medium bay / low bay luminaires should be deemed to be included in the unit rate quoted.
Taking down the defective Highbay light/Lowbay light/ flood light fittings by opening all the electrical connections and on site repairing of the fittings by opening the top cover of the fitting and checking all the electrical connections and replacing the defective parts with new parts,also re-assembling and refixing the fittings at the previous location complete all as specified and directed. Note:- All the parts required for the repair of the fittings shall be measured and paid separately under appropriate item of BOQ.
Supply only surge protector 10 kA with IP 65 protection, as per IS complete all as specified and directed.
Supply only driver suitable for 200 watt LED with IP 65 protection, as per IS complete all as specified and directed.
Supply only driver suitable for 250 watt LED with IP 65 protection, as per IS complete all as specified and directed.
S&F in repairs of HPSV/MH High bay light fitting with highbay luminare LED light fitting 200 watts, system wattage: 200 W, Lumen package : 24000 Lm, luminaire efficacy:> 120 Lm/W, four stage electrical protection : over/under voltage protection, short circuit and reverse polarity protection, Over temperature protection, Die-cast aluminium housing with dedicated optics for excellant beam distribution, Life: 50000 Hrs @L70, color temperature : 5700K + 300K, surge protection of internal 4kV and external 4kV complete all as specified and directed. Note:- Cost of neccessary tools and plants such as ladders, hydra for repair of high raised high bay / medium bay / low bay luminaires, suitable hanging items such as clamps/hooks/down rod etc should be deemed to be included in the unit rate quoted.
S&F in repairs of HPSV/MH High bay light fitting with highbay luminare LED light fitting 250 watts, system wattage: 250 W, Lumen package : 24000 Lm, luminaire efficacy:> 120 Lm/W, four stage electrical protection : over/under voltage protection, short circuit and reverse polarity protection, Over temperature protection, Die-cast aluminium housing with dedicated optics for excellant beam distribution, Life: 50000 Hrs @L70, color temperature : 5700K + 300K, surge protection of internal 4kV and external 4kV complete all as specified and directed. Note:- Cost of neccessary tools and plants such as ladders, hydra for repair of high raised high bay / medium bay / low bay luminaires, suitable hanging items such as clamps/hooks/down rod etc should be deemed to be included in the unit rate quoted.
S & F in repairs LED Flood light fitting 200 watt, system efficiency not less than 115 lumens/watt, IP 65 protection consisting of high/low voltage cut off maintenance free isolated electronic driver circuits, low THD PMMA grade high quality, Transmittance lens, epoxy powder coated Die cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws & connecting complete all as specified and directed. Note:- Cost of neccessary tools and plants such as ladders, hydra for repair of high raised Flood light, suitable hanging items such as clamps/hooks/down rod etc should be deemed to be included in the unit rate quoted.
S & F in repairs LED Flood light fitting 150 watt, system efficiency not less than 115 lumens/watt, IP 65 protection consisting of high/low voltage cut off maintenance free isolated electronic driver circuits, low THD PMMA grade high quality. Transmittance lens, epoxy powder coated Die cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws & connecting complete all as specified and directed. Note:- Cost of neccessary tools and plants such as ladders, hydra for repair of high raised Flood light, suitable hanging items such as clamps/hooks/down rod etc should be deemed to be included in the unit rate quoted.
S&F in repairs switch flame proof rotary type with termination box in LM6 , 16Amp single pole, ON-OFF, 250 volt, ISI marked, complete all as specified and directed.
S&F in repairs flame proof switch socket & plug combined in LM6, cable termination box in LM6 25 Amp, 250 volt, Double Pole with earth, ON-OFF, ISI marked, complete all as specified and directed.
S&F in repairs flame proof switch socket & plug combined in LM6, cable termination box in LM6 25 Amp, 500 volt, Triple Pole with earth, ON-OFF, ISI marked, complete all as specified and directed.
S&F in repairs flame proof Rotary switch with cable termination box in LM6 four pole 63 Amp(TPN)MCB, 415 volts, rupturing capacity 10 KA and conforming to latest IS/IEC, complete all as specified & directed.
S&F in repairs flame proof MCB Double pole 25 Amp,'C' curve, having rupturig capacity 10 KA and conforming to latest IS/IEC, complete all as specified and directed.
S&F in repairs flame proof MCB Single pole 6 to 25 Amp,'C' curve , having rupturig capacity 10 KA and conforming to latest IS/IEC, complete all as specified and directed.
KRISHNA CONSTRUCTION COMPANY
M/S SOLANKI GENERAL SUPPLIERS
M/S HARIOM CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .