Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC | L1 | Accepted-AOC Lowest Bid Value. | |
| 2 | L2₹2.7 L−₹20.2 L (88.3%)Rejected-AOC | L2 | Rejected-AOC Higher Bid Value. | |
| 3 | L3₹33.3 L+₹10.4 L (45.3%)Rejected-AOC | L3 | Rejected-AOC Higher Bid Value. | |
| 4 | L4₹35.1 L+₹12.2 L (53.3%)Rejected-AOC 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | L4 | Rejected-AOC Higher Bid Value. |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
5 Aug 2020, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE HQ TC AIR FORCE BANGALORE 560006
REPAIR/MAINT FOR INTERNAL ELECTRICAL DISTRIBUTION SYSTEM INCLUDING LIGHT FITTINGS, FIXTURE, REPAIR / MAINT OF LT PANEL, MCCBS/LT CABLE/SWITCH GEARS AND CONNECTED WORK AT POCKET II AND REPAIR/REPLACEMENT TO EARTHING FOR ELECTRIC SUPPLY INSTALLATIONS
2020_MES_359065_1
8697/GE-39
Open Tender
Miscellaneous Services
Item Rate
270 days
CH (AF) BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
Yes
₹72,000
Yes
18 Aug 2020
8 Jul 2020
7 Aug 2020
8 Jul 2020
5 Aug 2020
23 Jul 2020
9 Jul 2020 - 13 Jul 2020
Amount
Taking down carefully existing unserviceable point wiring with copper/ aluminium conductor cables (light, fan, socket or power) complete including fittings such as switches, ceiling rose, pendants, regulators, sockets but excluding light fittings complete and removing retrieved materials and making good the disturbed surfaces of wall, floor ceiling etc., complete all as specified and as directed.
Point wiring complete with 1100 volts grade single core, PVC insulated FRLS cable with multi-stranded copper conductor of size 1.5 sq mm nominal area, passing through heavy grade PVC casing casing 'N' capping/ PVC conduit of suitable size, with all necessary fittings on wall/ roof surfaces, duly earthed with one run of single core PVC insulated FRLS cable with multy stranded copper conductor of size 1.5 sqmm nominal area green in colour as continues earthing wire connected to common earth dolly including 1.6 mm thick fabricated CI/MS sheet terminal box concealed mounting in the wall for mounting switches,switch socket combination, fan regulators etc.covered with 3mm thick electroplated hylam sheet top cover for housing switches, sockets, regulators etc. complete for one light/ fan point controlled by one single pole 5 amps switch/socket including 1 run of 1.5 Sqmm green colour copper cable as continuous earth wire all as specified and as directed.
(a)One light point controlled by one single pole 5 Amps switch
(b)One fan point controlled by one single pole 5 Amps switch and regulator
(c )One light points controlled by two Nos of two way 5 Amps switch
(d)One switch socket out let point 5 Amps on independent board
(e)One switch socket out let point 5 Amps on same board with other switches
(f)One bell point controlled by one bell push
Point wiring complete with 1100 volts grade single core, PVC insulated FRLS cable with multi-stranded copper conductor of size 1.5 sq mm nominal area, passing through existing PVC casing casing 'N' capping/ PVC conduit on wall/ roof surfaces, duly earthed with one run of single core PVC insulated FRLS cable with multi stranded copper conductor of size 1.5 sqmm nominal area green in colour as continues earthing wire connected to common earth dolly complete using existing switches,switch socket combination, fan regulators etc for one light/ fan point controlled by one single pole 5 amps switch/socket all as specified and as directed.
(a)One light point controlled by one single pole 5 Amps switch
(b)One fan point controlled by one single pole 5 Amps switch and regulator
(c )One switch socket out let point 5 Amps on independent board
(d)One switch socket out let point 5 Amps on same board with other switches
Point wiring complete with 1100 volts grade single core, PVC insulated FRLS cable with multi-stranded copper conductor of size 2.5 sq mm nominal area, passing through heavy grade PVC casing casing 'N' capping/ PVC conduit of suitable size, with all necessary fittings on wall/ roof surfaces, duly earthed with one run of single core PVC insulated FRLS cable with multy stranded copper conductor of size 1.5 sqmm nominal area green in colour as continues earthing wire connected to common earth dolly including 1.6 mm thick fabricated CI/MS sheet terminal box concealed mounting in the wall , covered with 3mm thick electroplated hylam sheet top cover for housing 15 A switches, 15A sockets including 1 run of 2.5 Sqmm green colour copper cable as continuous earth wire all as specified and as directed.
Piano type switch single pole 5 Amps one way 230 volts all as specified and as directed
Piano type switch single pole 5 Amps two way 230 volts all as specified and as directed
Bell push 5 amps ,230 volts all as specified and as directed
Socket outlet 5pin multi purpose 5 Amps flush type all as specified and as directed
Socket outlet 5 pin multi purpose 5/15 Amps flush type all as specified and as directed
Switch 15A flush type universal pattern 230 v all as specified and as directed
PVC ceiling rose 65 x 50 mm surface type with 3 terminals all as specified and as directed
Electronic fan regulator socketed step type upto 100 watts with 5 step speed control for fans any sweep 1200 mm/1400 mm. make : Anchor/Crompton greevs all as specified and as directed
Call bell 230 v single pole fancy type Ding Dong Bell all as specified and as directed
Electronic ballast suitable for 36/40 W, fixed as in repairs, all as specified and directed. Make - Anchor/Havells/Bajaj/CG
Electronic ballast suitable for 28 W, fixed as in repairs, all as specified and directed. Make - Anchor/Havells/Bajaj/CG
Flourescent tube 28W, T-5, fixed as in repairs, all as specified and directed. Make- Havells/Bajaj/CG
Flourescent tube 36W, fixed as in repairs, all as specified and directed. Make- Havells/Bajaj/CG
LED lamp Adore 15W B22 Cdl Ball Lamp type 6500K, fixed as in repairs, all as specified and directed. Make- Havells/CG/Bajaj/Philips
LED lamp Adore 10W B22 Cdl Ball Lamp type 6500K, fixed as in repairs, all as specified and directed. Make- Havells/CG/Bajaj/Philips
Capacitor 2.5mfd 230 Volts suitable for ceiling fan any type and size, fixed as in repairs, all as specified and directed.
Capacitor 3.15mfd 230 volts suible for fan any type and size, fixed as in repairs, all as specified and directed.
Switch socket combination outlet 5 A , 5 pin Flush type, fixed as in repairs, all as specified and directed.
Switch socket combination outlet multipurpose 2 in 1 , 5/15 A Flush type, fixed as in repairs, all as specified and directed.
Electronic fan regulator socketed step type upto 100 watts with 5 step speed control for fans any sweep 1200 mm/1400 mm, fixed as in repairs, all as specified and directed. make : Anchor/Crompton/Havells
Switch piano one way 5 A SP ,230V flush type, fixed as in repairs, all as specified and directed.
Switch piano one way 15 A SP ,230V flush type, fixed as in repairs, all as specified and directed.
Switch piano two way 5 A SP ,230V flush type, fixed as in repairs, all as specified and directed.
Switch piano bell push 5 A SP ,230V flush type, fixed as in repairs, all as specified and directed.
Straight battern holder AC 230V, fixed as in repairs, all as specified and directed.
Call bell ding dong type 230V, fixed as in repairs, all as specified and directed.
LED tuberod 20W Glass type with single/double side connection including necessary connection suitable for tuberod, fixed as in repairs, all as specified and directed. Make-Havells CRYSTAL1213T8DSTL20WLED865SGLASS equivalent model in CROMPTON/PHILIPS/WIPRO/BAJAJ.
LED tuberod 18W Glass type with single/double side connection including necessary connection suitable for tuberod, fixed as in repairs, all as specified and directed. Make-Havells CRYSTAL1213T8DSTL18WLED865SGLASS equivalent model in CROMPTON/PHILIPS/WIPRO/BAJAJ.
LED tuberod batten with internaly pre-wired, fixed as in repairs, all as specified and directed. Make-Havells equivalent model in CROMPTON/ PHILIPS/WIPRO/BAJAJ.
LED tuberod 18W Glass type T-5 with single/double side connection including necessary connection suitable for tuberod, fixed as in repairs, all as specified and directed. Make-Havells TITANIASLEEK549T5DSTL9WLED865SPC equivalent model in CROMPTON/PHILIPS/WIPRO/BAJAJ.
Universal Starter 20/ 40watt for FTL fitting
LED light fitting 36Watt 2"x2" 230v new generation, LED Recessed full open 2X2 Tile, Glare free uniform illumination with longer life and less maintenance symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source including connecting up with twin core flexible copper conductor cable with suitable size, fixed as in repairs, all as specified and directed. Make: Havells ModelVENUSNEOHE2X2PLR36WLED8XXS or equivalent model in CROMPTON/PHILIPS/WIPRO/BAJAJ.
LED light fitting, 36 watt 4'x1" , 230v recessed & surface LED 1X4 Flat Panel ceiling light with high performance, commercial grade solution suitable for hospitals including connecting up with twin core flexible copper conductor cable with suitable size, fixed as in repairs, all as specified and directed. Make:Havells Model PLUTONEO4X1PLR36WLED857S or equivalent modelPHILIPS/WIPRO/BAJAJ
LED light fitting, 20 watt Surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver and including connecting up with twin core flexible copper conductor cable with suitable size , fixed as in repairs, all as specified and directed. Havells Model ENDURALINEARNEOBS20WLED865SPCWH or equivalent model in CROMPTON GREAVES/PHILIPS/WIPRO.
LED light fitting, 22watt 6500K decorative ultra slim aluminium square profile LED lighting fixture with high lumen output, environmental friendly, energy efficient including connecting up with twin core flexible copper conductor cable with suitable size, fixed as in repairs, all as specified and directed. Make : Havells Ordering code Delite Plus 22W LHEXBTP7IN1S022 or equivalent model in CROMPTON GREAVES/PHILIPS/WIPRO.
LED light fitting, 10watt bulk head luminaries, Environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-litLED luminaire comprising of high brightness LEDs including connecting up with twin core flexible copper conductor cable with suitable size, fixed as in repairs, all as specified and directed. Make: Havells Model RUGBYNEONFT10WLED760SSYMBOPC or equivalent model in CROMPTON GREAVES/PHILIPS/WIPRO.
LED light fitting, 20watt outdoor luminaries, New generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOPOpening seperate driver compartment with IP65 protection and impact resistance of IK07 including connecting up with twin core flexible copper conductor cable with suitable size and necessary GI pipe with clamps , fixed as in repairs, all as specified and directed. Make: Havells Model ENDURAPEARLSL20WLED757SASYTOPC or equivalent model in CROMPTON/PHILIPS/WIPRO/BAJAJ.
Suspension LED light fitting, 36watt classic styling with cutting edge technology to provide quality illumination and superior optical control. Use of direct/ indirect LED light engines makes it excellent choice for low heightceiling applications and areas where ceiling uniformity and indirect lighting is important (secondarysuspension kit included). including connecting up with twin core flexible copper conductor cable, fixed as in repairs, all as specified and directed. Make: Havells Model LICONLP36WLED857SPCGRY or equivalent model in CROMPTON/PHILIPS/WIPRO/BAJAJ.
LED light fitting 15W Surface mounted LED downlighter with white powder coated aluminium housing with integrated electronic driver, fixed as in repairs, all as specified and directed. Make: Havells model ENDURANEOSURFA CEDLS15WLED840S equivalent model in CROMPTON GREAVES /PHILIPS/WIPRO/BAJAJ.
Sub main wiring with Two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 10 sqmm in and including heavy grade PVC casing and capping/PVC conduit and its accessories with fixing arrangements on surface, wall, floor or ceiling etc including 10 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly, fixed as in repairs, all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing capping and two run of copper conductor together taken as one length for measuring unit length.
All as per serial item No 44 above but for 2x6 sqmmsqmm copper conductor cable 6 sqmm pvc insulated unsheathed copper earth continuity conductor, fixed as in repairs, all as specified and directed.
All as per serial item No 44 above but for 2x4 sqmm copper conductor cable 4 sqmm pvc insulated unsheathed copper earth continuity conductor, fixed as in repairs, all as specified and directed.
Sub main wiring with four single core PVC insulated cable with copper conductor multistranded 1100 volts grade 6.0sqmm in and including heavy grade PVC casing and capping/PVC conduit and its accessories with fixing arrangements on surface, wall, floor or ceiling etc including 6 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly, fixed as in repairs, all as specified and directed. Note : One run of earth continuity conductorand four run of copper conductor together taken as one length for measuring unit length.
Sub main wiring with four single core PVC insulated cable with copper conductor multistranded 1100 volts grade 10.0sqmm in and including heavy grade PVC casing and capping/PVC conduit and its accessories with fixing arrangements on surface, wall, floor or ceiling etc including 10 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly, fixed as in repairs, all as specified and directed. Note : One run of earth continuity conductorand four run of copper conductor together taken as one length for measuring unit length.
PVC casing & capping with accessories of size 20mm , fixed as in repairs, all as specified and directed.
PVC casing & capping with accessories of size 25mm, fixed as in repairs, all as specified and directed.
PVC casing & capping with accessories of size40mm, fixed as in repairs, all as specified and directed.
Sheet metal enclosure MCB DB double door type 230v with 4 ways SPN suitable bus bar model inrepalcement of old unserviceable DB, fixed as in repairs, all as specified and directed.
Sheet metal enclosure MCB DB double door type 230v with 8 ways SPN suitable bus bar model inrepalcement of old unserviceable DB, fixed as in repairs, all as specified and directed.
Sheet metal enclosure MCB DB double door type 230v with 12 ways SPN suitable bus bar model inrepalcement of old unserviceable DB, fixed as in repairs, all as specified and directed.
Sheet metal enclosure MCB DB double door type 230v with 4 ways TPN suitable bus bar model inrepalcement of old unserviceable DB, fixed as in repairs, all as specified and directed.
MCCB 125 Amps fixed thermal fixed magnetic setting, 430 volts, 10KA, 4 pole, fixed as in repairs, all as specified and directed.
MCCB 100 Amps fixed thermal fixed magnetic setting, 430 volts, 10KA, 4 pole, fixed as in repairs, all as specified and directed.
MCCB 63 Amps fixed thermal fixed magnetic setting, 430 volts, 10KA, 4 pole, fixed as in repairs, all as specified and directed.
MCB SP of 06 to 32A,'C' curve, 10KA rupturing capacity, fixed as in repairs, all as specified and directed.
MCB SPN of 06 to 32A,'C' curve, 10KA rupturing capacity, fixed as in repairs, all as specified and directed.
MCB SPN of 40A,'C' curve, 10KA rupturing capacity, fixed as in repairs, all as specified and directed.
MCB TPN of 63A,'C' curve, 10KA rupturing capacity, fixed as in repairs, all as specified and directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole 20A MCB ,C curve , 10KA, fixed as in repairs, all as specified and directed.
Hylam sheets of 3mm thick for housing switches /sockets / Regulaters etc and including cutting in to proper sizes and make holes connecting up, fixed as in repairs, all as specified and directed.
PVC gang boxes for 5/15A switch/sockets flush type, fixed as in repairs, all as specified and directed.
(a)Gang box two way
(b)Gang box three way
(c )Gang box four way
PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable of size 6 Sqmm 1100v grade, fixed as in repairs, all as specified and directed.
PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable of size 4 Sqmm 1100v grade, fixed as in repairs, all as specified and directed.
Detecting faults in internal wiring/fittings in OTM/Md accn under AGE E/M CHAFB and rectifiying the defects for restoring supply including replacing of unserviciable defective electrical accessories, all as specified and directed. Note :- (i) Rate for any item shall be measured and paid under respective item of schedule . (ii) Essential material like, insulation tape,screws and all tools required for carrying out the works and instruments to the defect fault shall be deemed to be included in the quoted rate (iii) The work is of day to day maintenace, required Electricians and Helper has to be attend daily for carryout the above work.
Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth and getting out in soft /Loose soil for laying of cable, complete all as specified and directed
Returning filling in, including spreading, levelling, watering and well ramming in layer not exc 25cm, complete all as specified and as directed.
Removal of surplus soil (excavated soil) to a distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed.
Sand cushioning with fine sand as specified in clause 14.5 of SSR Part-I to under ground cable in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed.
Burnt bricks, sub class 'B' of designation 75, standard size laid in trenches as in protection of UG cables, complete all as specified and as directed.
GI tubing light grade 50 mm bore as in cable protection fixed to poles/walls or laid intrenches/under road crossing etc. including taking up or down old unserviceable existing steel tubing and connections of size 50 mm or above, complete all as specified and directed
All as per Item No 74 but for 80 mm bore of steel tubing, complete all as specified and directed.
Boring of holes under road pavement hard standing by manual boring incl making good the disturbed surfaces, complete all as specified and directed
M & L LT UG cable 4 core x 16 sq mm 1100 Volts grade XLPE insulated , armored, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including,cable gland lugs/ thimbles/ ferrules including connecting, testing and commissioning complete for the following sizes including taking down existing old unserviceable LT UG cable of any size at site all as specified and directed. Make : Havells/Polycab/Universal Notes: (a) Excavation earth work and sand cushioning brick protectionand connected work etc. Shall be measured and paid separately under relevant item of schedule (b) Rate quoted deemed to include for cutting and removing of defective joints where required as directed.
All as per Item No 77. but for 3.5 core x 25 Sqmm, complete all as specified and directed.
All as per Item No 77. but for 3.5 core x 35 Sqmm, complete all as specified and directed.
All as per Item No 77 but for 3.5 core x 50 Sqmm, complete all as specified and directed.
All as per Item No 77 but for 3.5 core x 70 Sqmm, complete all as specified and directed.
All as per Item No 77 but for 3.5 core x 95 Sqmm, complete all as specified and directed.
1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape unarmoured with galvanised steel wire or tape and overall PVC sheathed 10 sq.mm , 2 core nominal cross section in service connections including taking down of existing old unserviceable cable of any type and size, complete all as specified and directed. Make : Havells/Polycab/Universal
1101 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape unarmoured with galvanised steel wire or tape and overall PVC sheathed 10 sq.mm , 4 core nominal cross section in service connections including taking down of existing old unserviceable cable of any type and size, complete all as specified and directed. Make : Havells/Polycab/Universal
Straight through joints heat shrink type suitable for 6 to 16 Sq. mm. x 3.5/4 core sizes of PVC/XLPE insulated and PVC sheathed armoured LT underground cable with aluminium conductors including joint kits and labour complete for making joints including taking down of existing old unserviceable joint of any type and size, complete all as specified and directed. Make : Denson/3M
All as per Item No 85 but for 25 to 50 Sq. mm. x 3.5/4 coreincluding taking down of existing old unserviceable joint of any type and size, complete all as specified and directed
All as per Item No 85 but for 70 to 95 Sq. mm. x 3.5/4 core including taking down of existing old unserviceable joint of any type and size, complete all as specified and directed
Aluminium cable lugs of size 16 Sqmm including taking down of existing old unserviceable lugs of any type and size, complete all as specified and directed
Aluminium cable lugs of size 25 Sqmm including taking down of existing old unserviceable lugs of any type and size, complete all as specified and directed
Aluminium cable lugs of size 35 Sqmm including taking down of existing old unserviceable lugs of any type and size, complete all as specified and directed
Aluminium cable lugs of size 50 Sqmm including taking down of existing old unserviceable lugs of any type and size, complete all as specified and directed
Aluminium cable lugs of size 70 Sqmm including taking down of existing old unserviceable lugs of any type and size, complete all as specified and directed
Aluminium cable lugs of size 95 Sqmm as including taking down of existing old unserviceable lugs of any type and size, complete all as specified and directed
Aluminium IN-Line connectors of size 16 Sqmm as including taking down of existing old unserviceable IN-Line connectors of any type and size, complete all as specified and directed
Aluminium IN-Line connectors of size 25 Sqmm including taking down of existing old unserviceable IN-Line connectors of any type and size, complete all as specified and directed
Aluminium IN-Line connectors of size 35 Sqmm including taking down of existing old unserviceable IN-Line connectors of any type and size, complete all as specified and directed
Aluminium IN-Line connectors of size 50 Sqmm including taking down of existing old unserviceable IN-Line connectors of any type and size, complete all as specified and directed
Aluminium IN-Line connectors of size 70 Sqmm including taking down of existing old unserviceable IN-Line connectors of any type and size, complete all as specified and directed
Aluminium IN-Line connectors of size 95 Sqmm including taking down of existing old unserviceable IN-Line connectors of any type and size, complete all as specified and directed
MCCB, 4 poles 415 Volts, 160 Amps, 16 kA, 50 Hz, AC, fixed thermal and fixed magnetic type in the existing LT panel board/sheet metal enclosure including connecting up incoming/out going cables with suitable lugs and testing, fixed as in repairs, complete all as specified and directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
MCCB, 4 poles 415 Volts, 200 Amps, 35 kA, 50 Hz, AC, adjustable type in the existing LT panel board/sheet metal enclosure including connecting up incoming/out going cables with suitable lugs and testing, fixed as in repairs, complete all as specified and directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
MCCB, 4 poles 415 Volts, 250 Amps, 35 kA, 50 Hz, AC, adjustable type in the existing LT panel board/sheet metal enclosure including connecting up incoming/out going cables with suitable lugs and testing, fixed as in repairs, complete all as specified and directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
MCCB, 4 pole, 415 Volts, 315/320 Amps, 35 KA, 50 Hz, AC, adjustable type in the existing LT panel board/ sheet metal enclosure including connecting up incoming/ out going cables with suitable lugs and testing, fixed as in repairs, complete all as specified and directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
ON LOAD change over switch with sheet metal enclosure 415V , 4 pole of capacity 250 Amps including connecting up incoming/ out going cables with suitable lugs and testing, fixed as in repairs, complete all as specified and directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
ON LOAD change over switch with sheet metal enclosure, 415V , 4 pole of capacity 315/320 Amps including connecting up incoming/ out going cables with suitable lugs and testing, fixed as in repairs, complete all as specified and directed.. Make: HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
Sheet metal enclosure made out of 2mm thick CRCA sheet duly power coated suitable for fixing/mounting MCCB of 160A Amps 4 pole duly fixed on wall with all fixing arangements, fixed as in repairs, complete all as specified and directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
Sheet metal enclosure made out of 2mm thick CRCA sheet duly power coated suitable for fixing/mounting MCCB of 250A Amps 4 pole duly fixed on wall with all fixing arangements, fixed as in repairs, complete all as specified and directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
MCB TPN 40 A, 'C' Curve,10KA rupturing capacity, fixed as in repairs, complete all as specified and directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
RCCB 40 Amps TPN ,'C' Curve,10KA rupturing capacity having sensitivity 30 Amps, fixed as in repairs, complete all as speified and directed.
RCCB 63 Amps TPN ,'C' Curve,10KA rupturing capacity having sensitivity 30 Amps, fixed as in repairs, complete all as speified and directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
RCCB 40 Amps SPN ,'C' Curve,10KA rupturing capacity having sensitivity 30 Amps, complete all as speified and directed. Make:HAVELLS/STANDARD/INDOASIAN/L&T/SCHNIDER
Cleaning, dusting and servicing LT panel ,MCCBS,Bus bars tightening cable connections, replacing of worn out parts such as busbar spout suppourts ,spacers,hinges,locks,glands and connected items/Mechanical parts etc for its smooth functioning including applying Becktrol red solution to the surface of the bus bars and spouts, applying Monoplast compound at the bus bar joints after tightening of joints ,cleaning the disturbed area beneath the LT panel and removing vegitation , derbis etc., complete all as specified and directed. (Note:- Rate quoted deemed to include for removing and replacing of defective items where required, complete all as specified and directed.
Painting the LT Panel complete of any capacity after preparation of surface and applying two coats of synthetic enamel (smoke grey) paint and old steel surafce , replace the Danger notice plate, complete all as specified and directed.
Danger notice plates, made out of 1.6mm thick MS sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT 20X15 cm size, fixed as in repairs, complete all as specified and directed.
Digital Multifunctional Panel meter for measuring Voltage ( 0-500V min ) ,Current , P.F , etc including necessary P.T & C.T's with all connected acccessories, fixed as in repairs, complete all as specified and directed Make : Selec/AE/Meco
Digital voltmeters 0-500V , with all connected accessories including connecting up and testing, fixed as in repairs, complete as all as specified and directed. Make : Selec/AE/Meco
Digital Ammeter 0-600A (min) , with CT's, all connected accessories including connecting up and testing, fixed as in repairs, complete as all as specified and directed. Make : Selec/AE/Meco
LED indicator lamp 240 V , with suitable colour Red/Blue/Yellow/Amber/Green and connected acccessories, fixed as in repairs, complete all as specified and directed Make : L&T/Siemens
Push button switch with NO/NC contacts 415 V ,6A , with add on Aux Contacts and connected acccessories, fixed as in repairs, complete all as specified and directed Make : L&T/Siemens
HBC/HRC Fuse up to 32A, fixed as in repairs, complete all as specified and directed. Make : LEGRAND/HAVELLS/L&T
HBC/HRC Fuse 40A to 125A, fixed as in repairs, complete all as specified and directed. Make : LEGRAND/HAVELLS/L&T
Earth continuity conductor GI Strip 25 x 4mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for direct/loop earthing with proper PVC/Porcelain insulator etc including taking down old unserviceable strip of any description and any size, complete all as specified and directed .
Earth continuity conductor GI Strip 32 x 6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for direct/loop earthing with proper PVC/Porcelain insulator etc including taking down old unserviceable strip of any description and any size, complete all as specified and directed.
Earth continuity conductor copper Strip 20 x 3 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for direct/loop earthing with proper PVC/Porcelain insulator etc including taking down old unserviceable strip of any description and any size, complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip of size 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point, testing on completion including taking down old earth pit of any type, complete all as specified and directed. Note : All earthing strips should be welded or brazing at each joint .
Earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip of size 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point, testing on completion including taking down old earth pit of any type, complete all as specified and directed. Note : All earthing strips should be welded or brazing at each joint .
High conductive, corrosion resistant, Maintenance free Chemical Earth pit for Transformer Neutral / Substation /Equipment/Telecom/DG set/Housing/Conventional Lightning conductor, ISO D-65 Ashlok Safe Earth Electrode Pipe in Pipe With hot Dip Galvanization 150 Microns 3 Meter long outer Dia 76mm & 42 Inner Dia 33mm Cavity Between Two Pipes Filled With Highly Conductive Non-Corrosive Grip Compound, Sealed from both the ends and filled with Earth Enhancing Material (EEM-BFC) of : 2 Bags of 25 Kgs, hot deep galvanized MS along with a Heavy duty high-density plastic/CI lockable cover cum inspection chamber, SS fasteners including all other required accessories and lay out modification as per site requirement, to complete the job of earth pit, testing on completion including taking down old earth pit of any type, complete all as specified and directed. Note : All earthing strips should be welded or brazing at each joint .
Repair/replacement of concrete pit in PCC (1:3:6) type C1 and pre moulded cast iron eart pit cover 300mm x300mm x 50mm including provision of funnel, wire mesh necessary excavation and earth work in any type of soil including paninting , marking of earth values with date, complete all as specified and directed
PVC Polymer/Porcelain insulator for existing GI/Aluminium/copper strip support, fixed as in repairs, complete all as specifed and directed
Test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25mm, drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal head screw complete fixed on wall in and including sheet steel enclosure of thickness 2 mm thickness with locking arrangement, complete all as specified and directed.
Repair/Reconditiong of exisitng earth pit by removing damaged Earth PCC chambers and excavate pit soil upto 25% of earth plate/electrode and adding alternate layers of charcoal, mixture of salt and copper sulphate up to 15cm above the earth plate/electrode and moist the mixture using water , cleaning/replacing of funnel with wire mesh where ever necessary , contractor should ensure that the earthing resistance should be below 5 Ohms , making good to distrubed surface, complete all as specified and directed. Note: 1. Deemed including excavation, returning filling and connected items. 2. Salt , charcoal , copper Sulphate, pit chamber , Testing will be measured and paid seperatly
Supply only pure charcoal granular/aggregate type having Ash content < 5% , stone free for earthing, complete all as specified and directed.
Supply only iodine free pure common salt crystal ( NaCl) for earthing, complete all as specified and directed
Supply only copper sulphate crystal (CuSO4) for earthing, complete all as specified and directed.
Testing of earthing resistance of existing earth pits using calibrated 3/4 wire digital Earth resistance meter and contractor is responsible to arrange calibrated earth resistance meter and also maintain earth resistance register with user signature to be submited to concerned office, complete all as specified and directed.
Vishwas Enterprises
LITE SYSTEMS INDUS
GKR and CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .