Tender Value
₹3.8 L
EMD Value
₹3,772
Closing Date
29 Jul 2020, 4:00 pmClosed
Executive Engineer STD Ganderbal
Office of Executive Engineer STD Ganderbal
Civil works for the Augmentation of Receiving Station Laar from 11.3 MVA to 16.3 MVA
2020_PDD_100003_1
STD/GBL/13 of 2020-21
Open Tender
Civil Works
Turn-key
30 days
Laar
Refer SBD, REC Drawings
7 documents required · 7 mandatory
₹1,000
Executive Engineer STD Ganderbal
₹3,772
24 Aug 2020
8 Jul 2020
30 Jul 2020
8 Jul 2020
29 Jul 2020
10 Jul 2020
8 Jul 2020 - 29 Jul 2020
Amount
Revamping of Earthing
Providing, Installation, testing & Commissioning of Chemical earthing arrangement which including digging and refilling of earth
Providing, erection/laying, testing & Commissioning of Earthing Mat (GI Flat 50 mm x6 mm ) which including digging and refilling of earth
Construction of foundation for transformer and other allied equipments along with G.I pipe structure at Receiving Station Laar
Earthwork excavation in foundation trenches including dressing of sides and ramming of bottom, including, all leads and lifts and disposal of excavated soil.
Supplying and laying (soling) of graded stone aggregate at site of size range 90 mm to 45 mm (Quarry)
Providing and laying in Position Cement concrete of Specified grade excluding the cost of centring and shuttering complete:1:4:8(1 cement: 4 Coarse Sand: 8 Stone Aggregate 40 mm nominal Size) Crushed
Providing and laying in Position Cement concrete of Specified grade excluding the cost of centring and shuttering complete:1:3:6 (1 cement: 3 Coarse Sand: 6 Stone Aggregate 20 mm nominal Size) Crushed (Under Ground & Above Ground)
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size)-Crushed
Centering and shuttering including strutting propping etc and removal of form work for foundations footings. bases of columns
12 mm cement plaster of mix 1:4 (1 cement : 4 fine sand)
Providing and fixing of structural steel of specified section for chainlink fencing, gantry structure, CT-VCB Structure & cable stands including cutting etc. and applying priming coat of approved steel premier (Complete job)
Providing laying and evenly spreading of stone soling of 40mm nominal size over 33KV yard including carriage
Supply and installation of 33KV equipment structures using GI Pipes (6'') 10' long, fitted with base and top plates with vertical plate supports (cut at rt. angle) ,including nuts and bolts.
Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete : White face insulating board 12 mm Thick
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick, First Class kail wood
Fixing of 500 Ltrs water storage tank , including all fitting, inlet out let nipples. Incl. ball cock.
Inner Re-Wiring of Control Room Building
Providing, Laying, testing and Commisioning of AC Wire 1 mm (Indo-Asian/ Havells/polycab/GM/Anchor Make)
Providing, Laying, testing and Commisioning of AC Wire 1.5 mm (Indo-Asian/ Havells/polycab/GM/Anchor Make)
Providing, Laying, testing and Commisioning of AC Wire 4 mm (Indo-Asian/ Havells/polycab/GM/Anchor Make)
Providing, Laying, testing and Commisioning of AC Wire 16 mm (Indo-Asian/ Havells/polycab/GM/Anchor Make)
Providing, Installation, testing and Commisioning of MCB 63 Amp 2-pole (Schneider/L&T/Anchor/Havells/Gm/Indo-Asian Make)
Providing, Installation, testing and Commisioning of MCB 32 Amp(Schneider/L&T/Anchor/Havells/Gm/Indo-Asian Make)
Providing, Installation, testing and Commisioning of MCB 10 Amp (Schneider/L&T/Anchor/Havells/Gm/Indo-Asian Make)
Providing, fixing, testing and Commisioning of Switches (GM/Gold Medal/Anchor/Havells/C&S/ Make)
Providing, fixing, testing and Commisioning of 3 Pin Switches (GM/Gold Medal/Anchor/Havells/C&S/ Make)
Providing, fixing, testing and Commisioning of Fan Dimmer (GM/Gold Medal/Anchor/Havells/C&S/ Make)
Providing, fixing, testing and Commisioning of 16 Amp Socket (GM/Gold Medal/Anchor/Havells/C&S/ Make)
Providing, fixing, testing and Commisioning of 16 Amp Switches(GM/Gold Medal/Anchor/Havells/C&S/ Make)
Conduit pipes PVC 25mm
Providing, fixing, testing and Commisioning of LED bulb 15 Watt (GM/Gold Medal/Anchor/Havells/C&S/ Surya/ Syska/Philips Make)
Providing and fixing of PVC Pipe bend 25mm
Providing and fixing of PVC saddle 25mm
Providing and fixing of steel saddle 25mm
Providing, Installation, testing & Commissioning of Panel Indicator (Tecknic/siemens - Make)
Providing and fixing of white plate hylam 2'x4'
Providing and fixing of Royal Plug
Providing and fixing of Black Screw 1''
Providing, Installation, testing & Commissioning of Exhaust Fan 9'' (Anchor/Bajaj/Kenstar/Khaitan Make)
Providing, Installation, testing & Commissioning of Ceiling Fan 48'' (Usha/Crompton/Bajaj/Khaitan Make)
Providing of Steel Routing Wire
Providing of Tape Roll
Providing & Fixing of Ceiling Rose (GM/Gold Medal/Anchor/Havells/C&S/ Make)
Providing & Fixing of Angle holder (GM/Gold Medal/Anchor/Havells/C&S/ Make)
HYDERIA GROUP OF ENGINEERS AND DESIGNERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .