Executive Engineer
Elect. Division HPPWD Palampur
Construction of ITI at Rajhoon in Tehsil Palampur, Distt. Kangra, HP (SH- Providing EI therein)
2022_PWD_60501_1
Elect. Division HPPWD Palampur
Open Tender
Electrical Works
Item Rate
730 days
Rajhoon in Teh. Palampur, Distt. Kangra
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,500
₹51,800
2 Aug 2022
11 May 2022
18 May 2022
11 May 2022
18 May 2022
11 May 2022
120 days
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. tmm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.(Make:-KEI,Anchor,L&T )Legrand (Myrius),L&T(Oris),Anchor(Roma plus)
Group C
Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.(Make:-KEI,Anchor,L&T )Legrand (Myrius),L&T(Oris),Anchor(Roma plus)
Group C
Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.Make:-KEI/SCI/Havells/Plaza
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(Make:-KEI,Anchor,L&T )
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. Make:-KEI/SCI/Havells/Plaza
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.(Make:-KEI,Anchor,L&T )
2x2.5 Sq. mm.
2x6 Sq. mm.
2x10 Sq. mm.
Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.10 Sq.mm. (4x10+2x10) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.Make:-KEI/SCI/Havells/Plaza
Wiring for circuit / sub-main with 4x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.16 Sq.mm. (4x16+2x16) HRFRLS/PVC insulated single core copper conductor cable for earthing as required. Make:-KEI/SCI/Havells/Plaza
Wiring for circuit / sub-main with 3x25+1x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.16 Sq.mm. (3x25+3x16) HRFRLS/PVC insulated single core copper conductor cable for earthing as required. Make:-KEI/SCI/Havells/Plaza
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required. Make:-KEI/SCI/Havells/Plaza
3x1.5 Sq. mm.
3x2.5 Sq. mm.
3x4.0 Sq. mm.
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required.
S.P. 5/ 6 Amps one way Modular switch. Makes:- Legrand(Myrius),L&T(Oris),Anchor Roma(Plus)
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required.
5 pin, 5/ 6 Amps Modular socket outlet. Makes:- Legrand(Myrius), L&T(Oris), Anchor Roma(Plus)
Telephone socket outlet, Modular.Makes:- Legrand(Myrius),L&T(Oris),Anchor Roma(Plus)
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required. Makes:- Legrand(Myrius),L&T(Oris),Anchor Roma(Plus)
S.P. 15/ 16 Amps one way Modular switch.Makes:- Legrand(Myrius),L&T(Oris),Anchor Roma(Plus)
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required..(Make:-Legrand (Myrius),L&T(Oris),Anchor(Roma plus)
6 pin,15/16 Amps Modular socket outletMakes:- Legrand(Myrius),L&T(Oris),Anchor Roma(Plus).
Supplying and drawing following pair of Fire Retardant, PVC insulated 0.5 sq.mm. (FR-Flexible) copper conductor, flat, unarmoured, telephone cable in existing surface / recessed, steel / PVC conduit as required..(Make:-KEI,Anchor,L&T )
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required..(Make:-Legrand (Myrius),L&T(Oris),Anchor(Roma plus)
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required..(Make:-Legrand (Myrius),L&T(Oris),Anchor(Roma plus)
Supplying & fixing of G.I. modular boxes of following sizes along with modular base and cover plate for modular switches in recess as required:-.(Make:-KEI,Anchor,L&T )Legrand (Myrius),L&T(Oris),Anchor(Roma plus)
2 modules (78mmx78mmx50mm)
4 modules(140mmx78mmx50mm)
12 modules (205mmx135mmx60mm)
Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:-Makes:- L&T/Anchor/Philips.
Supplying and fixing bakelite batten/angle holder including connections etc. as required:-Makes:- L&T/Anchor/Philips.
Supplying, Installation, Testing and Commissioning of indoor s/door,Cubical type L.T. Panel. The Panel shall be compartmentalized type having space and arrangement for incoming and outgoing cables/bus ducting, switchgear, insulated and properly supported compartmentalized bus-bars, interconnection between bus bars and switchgear with auxiliary bus bars/insulated conductors/strips etc. It shall be fabricated in 14G/16G CRCA sheet, base frame75X40X3MM angle duly painted with Siemens Grey Powder Coated paint, Assembly Charges of 250 A TPN Copper/Aluminium Busbar ( Horizental) & Earth strip throughout the length of Panel (current density of Copper/Aluminum Busbar shall be 1mmx1mm=1.0 Amp.) Copper/Aluminium shall be Electric Grade E-91E, Busbar supports shall be DMC epoxy Insulators. All Busbars Links shall be covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. Approximate Size of Panel H- 1250X W-1650 X D-350 MM. Assembly Charges of Aluminium/Copper solid/ Copper flexible wire interconnection Busbar to MCCB/ SWITCH & MCCB/ SWITCH to field side for Cable termination duly covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. All Interconnections of fields side are supported by conical, L & Finger type insulators of adequate size to support & sustain the weight of cables. Control Wiring with Copper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.0 sq. mm for Control & 1.0sq. mm for Scada Wiring) with thimbles printed sleeves, tie & belt etc. Assembly Charges of Accessories like Gasket, Doorlocks, Copper Flexible door earth, legend plates etc and the panel should be approved/tested from the CPRI lab and should be Comfirm I.S.64139(EVA or approved Equivalent make)
L.H.S. Panel (1250 mm (Length) x 1650 mm (width) x 350 mm (deep)(Approxi)
MATERIAL:
OUTGOING :
MCCB 125 A 4P 25 kA-01 No. with O/L & S/C protection,Spreater Terminal 2 Nos.,MCCB 100 A 4P 25 kA-01 No. with O/L & S/C protection,Spreater Terminal 2 Nos.MCCB 63 A 4P 25 kA-03 Nos. with O/L & S/C protection,Spreater Terminal 6Nos.
The Panel shall include the following Switchgear & accessories; as per the Make of Havells, Schneider, L&T, Siemens, ABB etc.
All interconnections of fields side are supported by conical, L & finger type insulators of adequate size to support & sustain the weight of cables, Control wiring with copper flexible FRLS wire with thimbles, printed sleeves, tie & belt etc.
The prices of complete job as per the specifications above shall be inclusive of gasket, doorlocks, reading glass,wooden, copper flexible door earth, legend plates etc.
Supplying, Installation, Testing and Commissioning of indoor s/door,Cubical type L.T. Panel. The Panel shall be compartmentalized type having space and arrangement for incoming and outgoing cables/bus ducting, switchgear, insulated and properly supported compartmentalized bus-bars, interconnection between bus bars and switchgear with auxiliary bus bars/insulated conductors/strips etc. It shall be fabricated in 14G/16G CRCA sheet, base frame75X40X3MM angle duly painted with Siemens Grey Powder Coated paint, Assembly Charges of 125 A TPN Copper/Aluminium Busbar ( Vertical) & Earth strip throughout the length of Panel (current density ofCopper/Aluminium Busbar shall be 1mmx1mm=1.0 Amp.) Aluminium shall be Electric Grade E-91E, Busbar supports shall be DMC epoxy Insulators. All Busbars Links shall be covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. Approximate Size of Panel H- 1550 X W-1000 D-300 mm Assembly Charges of Aluminium/Copper solid/ Copper flexible wire interconnection Busbar to MCCB/ SWITCH & MCCB/ SWITCH to field side for Cable termination duly covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. All Interconnections of fields side are supported by conical, L & Finger type insulators of adequate size to support & sustain the weight of cables. Control Wiring with Copper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.0 sq. mm for Control & 1.0sq. mm for Scada Wiring) with thimbles printed sleeves, tie & belt etc. Assembly Charges of Accessories like Gasket, Doorlocks, Copper Flexible door earth, legend plates etc.
L.H.S. Panel (1550mm (Length) x 1000 mm (width) x 300mm (deep)(approxi.)
MATERIAL:
OUTGOING :
MCCB 63 A 4P 25KA 4 Nos` TMR with O/L & S/C Protection Spreader link MCCB 63A 4P 8 Nos.
The Panel shall include the following Switchgear & accessories; as per the Make of Havells, Schneider, L&T, Siemens, ABB etc.
All interconnections of fields side are supported by conical, L & finger type insulators of adequate size to support & sustain the weight of cables, Control wiring with copper flexible FRLS wire with thimbles, printed sleeves, tie & belt etc.
The prices of complete job as per the specifications above shall be inclusive of gasket, doorlocks, reading glass,wooden, copper flexible door earth, legend plates etc.
Supplying, Installation, Testing and Commissioning of indoor s/door,Cubical type L.T. Panel. The Panel shall be compartmentalized type having space and arrangement for incoming and outgoing cables/bus ducting, switchgear, insulated and properly supported compartmentalized bus-bars, interconnection between bus bars and switchgear with auxiliary bus bars/insulated conductors/strips etc. It shall be fabricated in 14G/16G CRCA sheet, base frame75X40X3MM angle duly painted with Siemens Grey Powder Coated paint, Assembly Charges of 100 A TPN Copper/Aluminium Busbar ( Vertical) & Earth strip throughout the length of Panel (current density ofCopper/Aluminium Busbar shall be 1mmx1mm=1.0 Amp.) Aluminium shall be Electric Grade E-91E, Busbar supports shall be DMC epoxy Insulators. All Busbars Links shall be covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. Approximate Size of Panel H- 1250 X W-1400 D-300 mm Assembly Charges of Aluminium/Copper solid/ Copper flexible wire interconnection Busbar to MCCB/ SWITCH & MCCB/ SWITCH to field side for Cable termination duly covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. All Interconnections of fields side are supported by conical, L & Finger type insulators of adequate size to support & sustain the weight of cables. Control Wiring with Copper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.0 sq. mm for Control & 1.0sq. mm for Scada Wiring) with thimbles printed sleeves, tie & belt etc. Assembly Charges of Accessories like Gasket, Doorlocks, Copper Flexible door earth, legend plates etc.
L.H.S. Panel (1250mm (Length) x 1400 mm (width) x 300mm (deep)(approxi.)
MATERIAL:
OUTGOING :
MCCB 63 A 4P 25KA 4 Nos` TMR with O/L & S/C Protection Spreader link MCCB 63A 4P 8 Nos.
The Panel shall include the following Switchgear & accessories; as per the Make of Havells, Schneider, L&T, Siemens, ABB etc.
All interconnections of fields side are supported by conical, L & finger type insulators of adequate size to support & sustain the weight of cables, Control wiring with copper flexible FRLS wire with thimbles, printed sleeves, tie & belt etc.
The prices of complete job as per the specifications above shall be inclusive of gasket, doorlocks, reading glass,wooden, copper flexible door earth, legend plates etc.
Supplying, Installation, Testing and Commissioning of indoor s/door,Cubical type L.T. Panel. The Panel shall be compartmentalized type having space and arrangement for incoming and outgoing cables/bus ducting, switchgear, insulated and properly supported compartmentalized bus-bars, interconnection between bus bars and switchgear with auxiliary bus bars/insulated conductors/strips etc. It shall be fabricated in 14G/16G CRCA sheet, base frame75X40X3MM angle duly painted with Siemens Grey Powder Coated paint, Assembly Charges of 63 A TPN Copper/Aluminium Busbar ( Vertical) & Earth strip throughout the length of Panel (current density ofCopper/Aluminium Busbar shall be 1mmx1mm=1.0 Amp.) Aluminium shall be Electric Grade E-91E, Busbar supports shall be DMC epoxy Insulators. All Busbars Links shall be covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. Approximate Size of Panel H- 1350 X W-500 D-200mm Assembly Charges of Aluminium/Copper solid/ Copper flexible wire interconnection Busbar to MCCB/ SWITCH & MCCB/ SWITCH to field side for Cable termination duly covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. All Interconnections of fields side are supported by conical, L & Finger type insulators of adequate size to support & sustain the weight of cables. Control Wiring with Copper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.0 sq. mm for Control & 1.0sq. mm for Scada Wiring) with thimbles printed sleeves, tie & belt etc. Assembly Charges of Accessories like Gasket, Doorlocks, Copper Flexible door earth, legend plates etc.
L.H.S. Panel (1350mm (Length) x 500 mm (width) x 200mm (deep)(approxi.)
MATERIAL:
OUTGOING :
Space for MCB 63 A DP Isolator & Rccb MCB 6 To 32 A SP 36 nos MCB Short Bus Bar 36 Nos.
The Panel shall include the following Switchgear & accessories; as per the Make of Havells, Schneider, L&T, Siemens, ABB etc.
All interconnections of fields side are supported by conical, L & finger type insulators of adequate size to support & sustain the weight of cables, Control wiring with copper flexible FRLS wire with thimbles, printed sleeves, tie & belt etc.
The prices of complete job as per the specifications above shall be inclusive of gasket, doorlocks, reading glass,wooden, copper flexible door earth, legend plates etc.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
Single pole. Cat-A..Makes:- L&T/Legrand/Schneider.
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 Amps. Cat-A..Makes:- L&T/Legrand/Schneider.
63 Amps. Cat-A..Makes:- L&T/Legrand/Schneider.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 Amps. Cat-A..Makes:- L&T/Legrand/Schneider.
63 Amps. Cat-A..Makes:- L&T/Legrand/Schneider.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
Double door-4 way.Makes:- L&T/Legrand/Schneider.
Double door-8 way .Makes:- L&T/Legrand/Schneider.
Double door-12 way .Makes:- L&T/Legrand/Schneider.
Double door-16 way .Makes:- L&T/Legrand/Schneider.
Providing, Installation, testing and commissioning of Wall fan with modular step type electronic fan regulator, including wiring with 3 core 1.5 mm flexible, copper cable, including connection and earthing etc.completed as required.
Wall Fan 400 mm sweep, Category-A Makes:-Usha Helix(high speed)/Crompton/Anchor /Panasonic
Providing Installation testing and commissionning of ceiling fan with socket size modular steo type electronicfanregulator including wiring the down rods of standardlengh (Up to20 cm) with 16/0.20 mmtwin twisted flexible,cotton braided copper cable,includingproviding and fixing phenolic laminated sheet cover on the fan box and earting etc. as required.
Ceiling Fan 1200 mm sweep, Category-A Makes:-Usha Technic plus 3star/Crompton/Anchor /Panasonic
Ceiling Fan 1400 mm sweep, Category-A Makes:-Usha Striker(high speed)/Crompton/Anchor /Panasonic
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:-
Exhaust Fan, Light duty, (Domestic) 300 mm sweep Makes:-Usha/Crompton/Anchor/Panasonic
Exhaust Fan, Heavy duty, 300 mm sweep Makes:-Usha Striker(high speed)/Crompton/Anchor
Supplying and fixing Recess mounting 2'x2' size LED solution suitable for recess application with the use of the latest technology 36 Watt (3600 lumen) 5700K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc. as required.
Cat No: Jaquar(LSVR01S036XW-36W)Panasonic/Bajaj or equivalent.
Supplying and fixing surface mounting 2'x2' size LED solution suitable for surface application with the use of the latest technology 36 Watt (3600 lumen) 5700K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc. as required.
Cat No: Jaquar(LSVR01S036SW-36W)Panasonic/Bajaj or equivalent.
Supplying and fixing Recess mounting 1'x4' size LED solution suitable for recess application with the use of the latest technology 36 Watt (3600 lumen) 5700K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc. as required.
Cat No: Panasonic(PBLM16368 36W)/Bajaj/Jaquar or equivalent.
Supplying and fixing Surface mounting 1'x4' size LED solution suitable for surface application with the use of the latest technology 36 Watt (3600 lumen) 5700K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc. as required.
Cat No: Panasonic(PBLM15368 36W)/Bajaj/Jaquar or equivalent.
Supplying and fixing surface mounting Round type LED 20 Watt ( 2000 lumen), 6000 K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc.
Cat No: PDLM10206BS(Round 20 W) W(Round)/Wipro/Philips/or Equivalent
Supplying and fixing recess mounting Round type LED 20 Watt ( 2000 lumen), 6000K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc.
PPAM11206BS(Square 20 W)/Wipro/Philips/or Equivalent
Supplying and fixing surface mounting Square type LED 20 Watt ( 2000 lumen), 6000K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc.
Cat No: PDLM11206BS(Square 20 W) /Wipro/Philips/or Equivalent
Supplying and fixing Bulk Head LED 10 Watt (1000 lumen), 6500K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt,CRI > 80,suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories,connections, testing and commissioning etc. as required complete in all respects.
Cat No :-Panasonic(PBHM01107-10Watts)/Philips/Wipro or Equivalent.
Providing and fixing decorative extruded tube fixture having high quality design suitable for LED tube up to 20 Watt (2000 lumen) 5700K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz, including one no. tube rod 36 Watt complete with all accessories, connections, testing and commissioning etc. as required.
Cat No :-Panasonic( PBTM08208-20W-Tube Light 4 Feet Long)/Havell/Jaquar or equivalent.
Providing and fixing decorative extruded tube fixture having high quality design suitable for LED tube up to 36 Watt (3600 lumen) 5700K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz, including one no. tube rod 36 Watt complete with all accessories, connections, testing and commissioning etc. as required.
Cat No :-Panasonic( PBTM08368-36W-Tube Light 4 Feet Long)/Havell/Jaquar or equivalent.
Providing and fixing following type of Flood Light 50Watts (5000 Lumens),5700K mounting luminaire with powder coated CRCA sheet steel housing, diffusser to avoid glaire, pre-wired with, starter, trigger circuit, surge protection circuit lumen output of 100 lumens per watt complete with all accesseries, connections, testing and commissioning etc. as required.
Cat No :-Panasonic(PFLM11508-50Watts)/Jaquar/Havell or equivalent.
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required.
Providing and fixing 8 SWG (4 mm dia.) copper wire on surface or in recess for loop earthing as required.
Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for vertical run)
Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for horizontal run)
Providing and fixing of lightning conductor finial, made of 25 mm dia. 300 mm long copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required.
Supplying and fixing of G.I.pipe class "A" 80 mm dia. as required complete in all respects Makes: Diplast, BEC, Finolex.
Supplying and fixing of G.I.pipe medium class 32 mm dia. as required complete in all respects Makes: Diplast, BEC, Finolex.
Supplying and fixing of following sizes of steel conduit along with the accessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required:- Makes: Diplast, BEC, Finolex.
25 mm. dia
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:-
25 mm. dia Makes: Diplast, BEC, Finolex.
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:-
50 mm. dia Makes: Diplast, BEC, Finolex.
Providing and fixing extra conduit down rod of 20mm dia. x60 cm with 16/0.20 mm twin twisted flexible, cotton braided, copper cable including painting, connections etc. as required. ( Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored).
Supplying and drawing LAN cable CAT 6E, solid copper conductor protected with PVC sheath in the existing surface / recessed, steel / PVC conduit as required.
UTP Cat 6 Computer LAN Cable with star Seprator (Make:- Havell,KEI,Anchor,L&T )
Supplying and fixing 20 Amps, 415 volts, TPN industrial socket outlet, 4-pole & earth, metal enclosed plug top, sheet steel enclosure, suitable to accommodate a 20 Amp TPN-MCB, on surface or in recess, with chained metal cover for the socket outlet, complete with connections, testing and commissioning etc. as required. .(Make:-Legrand (Myrius),L&T(Oris),Anchor
Supplying and fixing following rating, four pole, 415 volts, Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 Amps. Cat-A..(Make:-Legrand (Myrius),L&T(Oris),Anchor(Roma plus)
Providing and fixing TP&N switch disconnector fuse unit panel mounting, 415/500 volts with 3 No. HBC/HRC fuses, open execution, including drilling holes in the cubical, making connections, etc. as required.
32 Amp. Category-A.(Makes :-Legrand (Myrius),L&T(Oris),Anchor(Roma plus)
JAMWAL ELECTRICAL WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .