Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹10.5 LAccepted-AOC ERATTAKULAM PAROLA ROAD RETARRING PROJ NO 42 WARD 18 | THIRUVANANTHAPURAM | KERALA | 695001 | 1 | Accepted-AOC 1 | |
| 2 | 2₹10.6 L+₹888 (0.08%)Accepted-AOC KOLATH NILAPOLA P O | KERALA | 2 | Accepted-AOC 2 |
Tender Value
Refer Docs
EMD Value
₹26,395
Closing Date
21 Mar 2024, 11:00 amClosed
Asst Exe.Engnr(Agri),Alappuzha
Asst Exe.Engnr(Agri),Alappuzha 688003
Chambakulam Division Chambakulam GP Ward 6 Pattathin varambinakam padam-Motor thara Shed and Side protection wall
2024_AGRI_668116_1
AE(3)801/23
Open Tender
Civil Works - Others
Item Rate
120 days
Champakkulam
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹26,395
9 Jun 2025
7 Mar 2024
22 Mar 2024
7 Mar 2024
21 Mar 2024
7 Mar 2024
Amount
Motorthara
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
OD3702/2023-2024:Modified old 60.7.2 DR PACKING under foundation -dry stone packing under foundation with good quality blasted rubble including conveyance of material and labour charges etc complete as per direction of department officers at site .
OD3703/2023-2024:DRY RUBBLE MASONRY -Dry rubble witout concrete levelling course masonry with good quality blasted rubble including packing to compactness to line and level cost and conveyance of all material ,labourcharge etc complete as per directions of departmental officers at site ( boat load upto 3 KM)
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.6:Reinforced cement concrete work in chimneys, shafts, up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement : 1.5 coarse sand(Zone III) : 3 graded stone aggregate 20 mm nominal size)
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.6.1.8:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.51.1:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm)
OD3704/2023-2024:FIlling with red earth (excluding rock) in trenches,plinth,sides of foundation etc in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering,lead upto 50m and liftupto 1.5m as per direction of site Engineer-in-charge
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
JACOB GEORGE
Bidder Name
JACOB GEORGE
MADHUSUDHANAN
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1038655.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .