Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 CrAccepted-AOC | ₹13.6 Cr | L1 | Accepted-AOC lowest |
| 2 | L2₹16.6 CrRejected-Finance | ₹16.6 Cr | L2 | Rejected-Finance not being lowest |
| 3 | L3₹17.5 CrRejected-Finance UNIT B2 AUTONAGAR VISAKHAPATNAM VISAKHAPATNAM ANDHRA PRADESH 530012 | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | ₹17.5 Cr | L3 | Rejected-Finance not being lowest |
| 4 | L4₹18.6 CrRejected-Finance | ₹18.6 Cr | L4 | Rejected-Finance not being lowest |
| 5 | L5₹19.1 CrRejected-Finance | ₹19.1 Cr | L5 | Rejected-Finance not being lowest |
Tender Value
₹10.2 Cr
EMD Value
₹8.6 L
Closing Date
6 May 2022, 6:00 pmClosed
CHIEF ENGINEER (NAVY) VISAKHAPATNAM
CHIEF ENGINEER (NAVY) STATION ROAD VISAKHAPATNAM
PROVN OF TRANSIT ACCOMMODATION FOR SAILORS AT VISAKHAPATNAM
2021_MES_485888_2
85356
Open Tender
Civil Works
730 days
VISAKHAPATNAM
AS PER NIT
9 documents required · 9 mandatory
₹3,000
GARRISON ENGINEER PROJECT NO2 NAVY
₹8.6 L
25 Mar 2023
23 Feb 2022
9 May 2022
23 Feb 2022
6 May 2022
7 Mar 2022
23 Feb 2022 - 6 Mar 2022
Amount
Schedule "A" Part – I to Schedule "A" Part – XVI: NOTE: Schedule "A" Part – I to Part – XVI are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for "BUILDINGS & STRUCTURES", as listed in Schedule "A" Part – I
Lumpsum price worked out by the contractor for "SITE CLEARANCE / AREA DEVELOPMENT / EARTHWORK EXCAVATION", as listed in Schedule "A" Part – II
Lumpsum price worked out by the contractor for "PILE FOUNDATION", as listed in Schedule "A" Part – III
Lumpsum price worked out by the contractor for "COMPOUND WALL AND GATE", as listed in Schedule "A" Part – IV
Lumpsum price worked out by the contractor for "ROAD / PATH / HARD STANDING/CHEQUERED TILE", as listed in Schedule "A" Part – V
Lumpsum price worked out by the contractor for "AREA DRAINAGE", as listed in Schedule "A" Part – VI
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL", as listed in Schedule "A" Part – VII
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY", as listed in Schedule "A" Part – VIII
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – IX
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY", as listed in Schedule "A" Part – X
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – XI
Lumpsum price worked out by the contractor for " LIGHTENING PROTECTION", as listed in Schedule "A" Part – XII
Lumpsum price worked out by the contractor for " FIRE FIGHTING SYSTEM ", as listed in Schedule "A" Part – XIII
Lumpsum price worked out by the contractor for " FIRE ALARM SYSTEM", as listed in Schedule "A" Part – XiV
Lumpsum price worked out by the contractor for "SOLAR WATER HEATER", as listed in Schedule "A" Part – XV
Lumpsum price worked out by the contractor for "ARBORICULTURE", as listed in Schedule "A" Part – XVI
Schedule "A" Part - XVII: [Miscellaneous Items]
Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to galvanised iron strip 32 x 6 mm (upto 7.5m in length from earth plate) by means of brass bolts and nuts checknuts and washers of brass all as specified and shown in electrical plate no 3 of SSR part I including charcoal and rock saolt with necessary excavation and earth wotk in any type of soil PCC 1:3:6 type C1 chamber with CI cover 10mm thick Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel, 50mm dia light grade pipe for protection of earth electrode and 20mm dia pipe for watering all as specified and directed and tested on completion complete all as specified.
PILE FOUNDATION
Boring for bored cast in situ piles 450mm dia in any type of soil/clay/soft rock except hard rock/fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed.
Boring for bored cast in situ piles 450mm dia in hard rock & fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed.
Chipping out piles up to cut off level including disposal of spoil to out side MD land all as specified and as directed.
Carrying out Initial load test on 450mm dia piles, complete all as specified and directed.
Carrying out routine load test on 450mm dia piles, complete all as specified and directed.
Carrying out lateral load test on 450mm dia piles, complete all as specified and directed.
Carrying out initial pullout test on 450mm dia piles, complete all as specified and directed.
Carrying out low strain integrity test on 450mm dia piles including analysing the results complete all as specified and directed.
INTERNAL WATER SUPPLY
S & F CP mixer for mixing hot and cold waterscrewed down for 20 mm PP-R pipe chromium plated , fancy type with two out going(one for bib tap and another for shower complete all as specified and as diredcted.
S & F Angle stop valve, chromium plated , fancy type , high pressure screwed and fixed suitable for 20mm PP-R pipe complete all as specified and directed.
INTERNAL ELECTRIFICATION
Ponit wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multistranded 1100 Volts grade, ISI marking drawn thorugh and inculding non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marking, including pressed steel terminal box made with MS sheet 2mm thick suitable for fixing switches, sockets, inculding one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth duly complete all as specified and directed for One light point controlled by one switch on independent board complete all as specified and directed.
Ponit wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multistranded 1100 Volts grade, ISI marking drawn thorugh and inculding non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marking, including pressed steel terminal box factory made with MS sheet 2mm thick suitable for fixing switches, sockets, inculding one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth duly complete all as specified and directed for One bell point controlled by one bell push on independent board complete all as specified and directed.
Ponit wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multistranded 1100 Volts grade, ISI marking drawn thorugh and inculding non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marking, including pressed steel terminal box factory made with MS sheet 2mm thick suitable for fixing switches, sockets, inculding one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth duly complete all as specified and directed for One fan (ceiling fan/ex.fan) point controlled by one switch on independent board complete all as specified and directed.
Ponit wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multistranded 1100 Volts grade, ISI marking drawn thorugh and inculding non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marking, including pressed steel terminal box factory made with MS sheet 2mm thick suitable for fixing switches, sockets, inculding one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth duly complete all as specified and directed for One 3 Pin socket outlet 6 Amps socket on independent board complete all as specified and directed.
All as per item No.35 here-in-before but One 3 pin socket outlet 15 amps socket on independent board with FRLS PVC wire 4 sqmm for phase and neutral and one run of 4 sqmm copper cable green in colour for earth continuty conductor complete all as specified and directed.
All as per item No.35 here-in-before but one light point controlled by two Nos two way switches complete all as specefied and directed.
Supply and fixing LED adore lamp for AC 240Volt supply, B22 type,CDS five star, 9 watts of five star rated complete all as specified and as directed.
Supply and fixing ceiling fan AC single phase 230 V of size 1200 mm sweep, copper wound with complete set and fixtures such as canopy, down rod etc. 5 Star rating, metallic body complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire complete all as specified and directed.
S&F exhaust fan 250 mm sweep or nearest size, plastic body (Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening,fixing and making good the distrubered surfaces etc. complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire complete all as specified and directed.
S&F exhaust fan 300 mm sweep, (Heavy duty),900 RPM, complete with louvers suitable for operation on 240 V AC, 50 Hz AC supply fixed on wall including making of neccessary opening, fixing and making good the disturbed surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire complete all as specified and directed.
S&F exhaust fan 380 mm sweep or nearest size, 900 RPM , (Heavy duty), complete with louvers suitable for operation on 240 V AC, 50 Hz AC supply fixed on wall including making of neccessary opening, fixing and making good the disturbed surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire complete all as specified and directed.
Supply and fixing energy efficient LED tube light fitting with tube 20 watts or nearest size, 240V, 50Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed
Supply and fixing LED Security light fitting with tube 30W new generation energy saving &environmental frindly long lifemade up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening seperate driver compartment with IP66 protection pre wired with 1.0 Sq mm copper conductor cable upto connector including 1.5 m long GI tubing light grade of 32mm dia bend to shape for fixing on wall/pole with suitable MS brackets nuts and bolts etc. compelte all as specified and as directred.
Material and labour for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall, and PVC wire of size 4x16sqmm for phase and neutral duly colour coded and 1x16 sqmm for earth continuity conductor green in colour complete all as specified and as directed.(Bus bar trunk/MCCB to VTPN DB of each floor). Note :(i) Four runs of 16.0 Sqmm + one run of 16.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
Material and labour for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall, and PVC wire of size 2x6sqmm for phase and neutral duly colour coded and 1x6 sqmm for earth continuity conductor green in colour complete all as specified and as directed.(for each qtr DBs & metal clad socket in each DUs). Note :(i) Two run of 6.0 Sqmm + one run of 6.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
Material and labour for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall, and PVC wire of size 2x2.5sqmm for phase and neutral duly colour coded and 1x2.5 sqmm for earth continuity conductor green in colour complete all as specified and as directed.( parking, staire case and common area lighting DB of each floor). Note :(i) Two run of 2.5 Sqmm + one run of 2.5Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
Supply and fixing concealed in wall Vertical MCB DB double door type, TPN 4 way 415V, 50Hz, IP 43 protection with 200A rated bus bar, including provision for fixing RCBO FP 63 amp as incommer and SP MCBs as outgoings complete, fill empty way with blanking plates complete all as specefied and directed.
Supply and fixing single phase electronic Energy meter tamper proof with LCD display, 240 volt , 50Hz AC supply, 5 to 30 amps capacity complete all as specified and as directed.
Supply and fixing prefabricated meter box made out of 2mm thick CRCA sheet duly powder coated of approx size 50cm x 60 cm to accommodate 6 Nos single phase energy meter, front portion of the meter box to be provided with four opening to take the reading of energy meter and the four slit is to be covered/fixed with glass, necessary sunmica sheet of suitable size to be provided inside the meter box to fix the energy meter, with locking arrangements complete all as directed and as specified. Note: Energy meter shall be measured and paid seperately.
M&L for earthing complete with copper plate electrode 60cmX 60cmX 3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to copper strip of 20mm x 3mm by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No-5 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipelight grade for watering pipe and 32 mm bore GI light grade for earth lead protection pipe connected upto DBs, and suitable CI top cover with handle, funnel, strainer,charcoal, salt and testing on completion all as specified and directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC workcomplete all as specefied and directed.
Supply and fixing earth continuity copper conductor of size 20mm x 3mm as earthing lead fixed to wall with and inclussive of GI pipes 25 mm dia light grade for protection of earth strips or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation complete all as specified and directed.
Supply and fix TV socket incuding GI box, inner and cover plates complete all as specefied and directed.
ROAD / PATH / HARD STANDING/CULVERT
M & L for Granular sub Base (GSB) with grading V of 150mm thick Compacted thickness (laid in two layers of 75mm each, Compacted seperately) confirming to grading as specified, spread, rolled and consolidated to required gradient asnd camber complete using necessary mechanical paver/ Grader and vibratory soil compacter of Capacity 8-10 ton all as specified and as directed. (a) Pavement shall be made for solid quantity arrived after consolidation. (b) Compaction of granual sub base filling shall be carried out under Optimum moisture condition to achieve 98.50 modified density. (c) Curing shall be carried out as per IRC recommendations. (d) Before execution of this item the approved material obtained from outside MD land shall be tested/ checked for suitability to use. (e) The lead/ Royalty involved is to be ascertained by the contractor before quoting his tender and no extra payment/ Adjustment for increased in lead or Rate of Royalty due to whatever reason shall be admissible on his account. (f) Contractor shall use Vibratory earth compactor inlieu of Power roller to achieve 98 % MDD at OMC without any extra cost and the method of compaction to be adopted as per recommendation of agency reporting MDD at OMC. (g) GSB shall be as per MORTH specification as detailed in Particular specifications.
M & L for Wet mix Macadam of 250mm thick (Compacted thickness) laid in three layers compacted seperately with Coarse aggregate of specified grade spred rolled and consolidated to required gradient and camber complete using mechanical paver/ Grader and Pandom Vibrator of capacity of minimum 8-10 Tons at OMC to achieve atleast 98% MDD determained using modified Proctor density determination method as per IS code on prepared GSB surface complete all as specified and as directed.
M & L for Painting lines, dashes, arrows, letters, etc. on road surface with hot applied retro reflective thermoplastic paint confirming to MORTH (Clause. 803.40) all as specified with 8% glass beads using special applicator machine with heating arrangement upto 160 Degress C, including cleaning and drying the road surfaces to ensure dust,oil,grease and moisture free surface beforeapplying paint complete all as specified as directed.
EXTERNAL WATER SUPPLY
Construction of Valve Chamber of size 750 X 750 X 750 mm comprising of 50mm thick PCC 1:5:10 type E2 foundation, 200 mm thick brick wall in CM 1:6, 15 mm thick plastering in CM 1:4 internally and externally upto 50mm below GL, 100 mm thick PCC 1:3:6 type B1 as in copings, 3mm thick MS sheet cover with suitable hinges and locking arrangements, painting steel surfaces with two coats of synthetic enamel paint over a coat of primer including necessary earth work and excavation in any type of soil complete all as specifed and as directed.
Cutting existing steel tubing for alterations or additions necessarily done in position without taking down and inserting T of 100 x 100 x 80 mm and Tee of 80 x 80 x 80 mm for tapping complete all as specified and as directed.
FIRE ALARAM SYSTEM
Supply and fix 2 core 1.5 sqmm1100V grade FRLS armoured copper cable as per IS:1554 with metallic conduit and conduit accessories to wall/roof/false ceiling/ floors with necessary clamps/saddles all as specified and directed.
FIRE FIGHTING SYSTEM
Supply and fix Star delta starter for booster pumpset with single phasing preventor suitable for 7.5 HP motor with steel sheet enclosure complete all as specified and as directed.
ARBORICULTURE
Supply & Planting carpet Grass by piece turfing including preparation of ground upto 30 cm deep and filling soft soil, cow dung and watering etc,. (loose soil, cow dung Pesticides and manures shall be measured and paid separately as supply only ) by complete all as specified and directed.
Supply & Planting paspalum Grass by piece turfing including preparation of ground upto 30 cm deep and filling soft soil, cow dung and watering etc (loose soil and cow dung will measured separately) by the Engr-in-charge(All around foot ball field within running track area excluding basket ball field) complete all as specified and directed.
Supply only approved loose soil best quality for plantation complete all as specified and directed.
Supply only approved manure(cow dung) best quality complete all as specified and directed.
Supply only approved vermi compost best quality complete all as specified and directed.
Supply and plantation of foxtail palm (height of plant not less than 2.0m above ground level) incl preparation of ground up to 30cm deep and filling of good earth, cow dung vermi compost and watering etc., complete all as specified and directed.
Supply and plantation of royal palm of height not less than 1.5 m above ground level) incl preparation of ground up to 30cm deep and filling of good earth, cow dung vermi compost and watering etc., complete all as specified and directed.
S & F for brass water Sprinckler 15 mm dia OL hose--end sprayer fixed in pipe line, consisting of 02 Rotary Nozzles/ Radiators, radius 0.5-5.5M, flow 0.2 to 17 LPM, pop-up height 2M and weight not less than 0.4Kg complete all as specified and directed.
AVIATION LIGHT
Supply & Fix aviation obstruction light LED type filament-less bulb with 10 watt bulb complete including standard fixing arrangements complete all as specified and as directed
Supply & fix copper cable PVC insulated 1100V grade FRLS, 2.5 sqmm 3 core multi stranded conductot, fixed to wall/roof etc with suitable clamps spacers bolts nuts including PVC conduit 25mm etc. complete all as specified and as directed.
Supply & fix time switches 250V single phase of 20Amp rating with contactor fitted inside steel enclosure, complete all as specified and directed.
EXTERNAL ELECTRIFICATION
M&L for earthing complete with GI earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth lead wire 4mm dia. by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 15mm bore GI medium grade earth lead protection pipe connected up to DBs, and suitable CI top cover with handle, funnel, strainer, char coal and testing on completion all as specified and as directed. Note:- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC (1:3:6) type C1 in pad and pit complete all as specefied and directed.(This caters for all relevant Schedules like Lift, , External Electrification , Fire Fighting/ Fire Alarm, Solar water Heater & Lightening Protection)
Supply and fix and testing bus bar trunking system for the complete building power supply duly insulated three phase of rating 250 Amps, 25 KA 415 Volts aluminium conductor galvanised GI enclosure 0.8 mm thick (non painted) and lightening bus trunking with galvanised steel enclosure (0.45 mm thick), non painted through service shaft including end feed unit with MCCB 250 AMp, 25 KA 4 pole with rotary handle, termination links of building comprising of the following complete all as specified and directed.
Supply and fix straight length with plugin outlet complete all as specified and directed.
Supply and fix Flange End complete all as specified and directed.
Supply and fix Horizontal elbow complete all as specified and directed.
Supply and fix Vertical elbow complete all as specified and directed.
Supply and fix End Cap complete all as specified and directed.
Supply and fix Brackets complete all as specified and directed.
Supply and fix Springs support complete all as specified and directed.
Supply and fix Fire Barrier complete all as specified and directed.
Supply and fix external GI earth strip 32 x 6 mm complete all as specified and directed.
Supply and fix End feed unit with MCCB complete all as specified and directed.
Supply and fix 250 Amp, 25 kA, 4 pole MCCB complete all as specified and directed.
Supply and fix terminal links as required complete all as specified and directed.
Supply and fix 63 Amp Thermoplastic plug in tapoff box with 8 module MCB complete all as specified and directed.
Supply and fix MCB 63Amp 4 pole 10 kA complete all as specified and directed.
Supply and fix 63 Amp 4 pole lightening trunking complete all as specified and directed.
Supply and fix feed unit with end cover complete all as specified and directed.
supply and fix flexible joint complete all as specified and directed.
Suppply and fix Bracket support with steel cable complete all as specified and directed.
Materal and labour of integral LED street light luminaire 40 Watts, comprising of epoxy powder coated, pressure die cast aluminium housing enclosed with glass cover in frame with suitable size of bracket nut and bolts PVC insulated three core flexble cable of suitable size and length duly connected to light fitting complete including installation and testing complete all as specified and as directed.
S&F Loop in loop out box of size (202x238x111mm)1 row 9 modules of FRP made with IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit, Combi climate Cable Glands of IP 66/ IP 67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 kA, C Curve Overload and Short Circuit protection, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands, etc., complete all as specified and directed.
Boring of holes under road, pavements, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4mpa working pressure complete all as specified and directed.
Supply and fix time switch 415V, single phase of max 20Amps rated with contactor fitting inside steel enclouser complete all as specified and directed.
a) Fire man switch b) Automatic rescue device (A.R.D) during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load. c) Battery operated emergency light (LED ceiling fitting ), alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeable arrangement for battery. d) Four sleek circular LED light fitting 5W-4 Nos in and includes false ceiling. e) One sleek circular PVC heavy duty fan 300 mm sweep in false ceiling. Make for (c) and (d) : Philips/ Bajaj / Havells / Crompton Greaves. f) Aluminium chequered plate (3mm thick) as flooring joint in chequered plate should not more than one and top covering with Granite flooring complete. g) Non stop button /independent operation. h) Over load warning indicator both audio and visual type with tripping system having relays etc (overload protection/tripping system). j) Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds.
k) Car size shall be in confirmity with IS -3534-1976 and body to be stainless steel of 16 gauge SS moon rock finish with stainless steel hand rail 38mm hairline finish. l) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS m) Mirror of 4mm thickness of suitable size as specified. n) Opeing with mirror of 5mm thick 200X600mm size in all the doors (Car/Landing doors). o) Specification plate with complete details. p) Continous earthing for machine and equipments. s) Full length display indicator panel. t) Main drives and control shall be of latest , high effective and low power consumption. u) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage. v) Stainless steel front opened landing door with small opening for vision of size 200mm x 800mm with toughened glass not less than 8mm thick. w) Intercom be connected with nearest security post
a) Fire man switch b) Automatic rescue device (A.R.D) during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load. c) Battery operated emergency light (LED ceiling fitting ), alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeable arrangement for battery. d) Four sleek circular LED light fitting 5W-4 Nos in and includes false ceiling. e) One sleek circular PVC heavy duty fan 300 mm sweep in false ceiling. Make for (c) and (d) : Philips/ Bajaj / Havells / Crompton Greaves. f) Aluminium chequered plate (3mm thick) as flooring joint in chequered plate should not more than one and top covering with Granite flooring complete. g) Non stop button /independent operation.
h) Over load warning indicator both audio and visual type with tripping system having relays etc (overload protection/tripping system). j) Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. k) Car size shall be in confirmity with IS -3534-1976 and body to be stainless steel of 16 gauge SS moon rock finish with stainless steel hand rail 38mm hairline finish. l) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS m) Mirror of 4mm thickness of suitable size as specified. n) Opeing with mirror of 5mm thick 200X600mm size in all the doors (Car/Landing doors). o) Specification plate with complete details. p) Continous earthing for machine and equipments. s) Full length display indicator panel. t) Main drives and control shall be of latest , high effective and low power consumption.
u) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage. v) Stainless steel front opened landing door with small opening for vision of size 200mm x 800mm with toughened glass not less than 8mm thick. w) Intercom be connected with nearest security post
Note for LIFTS :- Cost of comprehensive/periodical maintenance of Lifts including spare parts during defect liability period is deemed to be included in the rate quoted for the lift item under respective Phase.
MAINTENANCE OF ARBORICULTURE
Material and labour for maintenance including watering and fertilization of all the grass/plants/trees by weeding housing saucer melding once in every 15 days, planting new plants/grass spices and height with out any extra cost to the department for period of maintenance period of 06 (SIX) months from the completion date of project complete all as specified and directed.
COMPREHENSIVE MAINTENANCE OF LIFTS
Comprehensive maintenance of Electrically Operated 08 passenger lifts(544 Kgs) to serve G+8 upper floors all as mentioned vide SI No. 103 of Sch "A" Part - XVII during 1st year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 13 passenger lifts(884 Kgs) to serve G+8 upper floors all as mentioned vide SI No. 106 of Sch "A" Part - XVII during 1st year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 08 passenger lifts(544 Kgs) to serve G+8 upper floors all as mentioned vide SI No. 103 of Sch "A" Part - XVII during 2nd year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 13 passenger lifts(884 Kgs) to serve G+8 upper floors all as mentioned vide SI No. 106 of Sch "A" Part - XVII during 2nd year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 08 passenger lifts(544 Kgs) to serve G+8 upper floors all as mentioned vide SI No. 103 of Sch "A" Part - XVII during 3rd year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 13 passenger lifts(884 Kgs) to serve G+8 upper floors all as mentioned vide SI No. 106 of Sch "A" Part - XVII during 3rd year after expiry of defects liability period all as specified and directed
Note for comprehensive maintenance:- (i) Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts & consumables like topping of gear oils/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes for the above lifts. (ii) Preventive maintenance consists of carrying out routine check by skilled personal as specified in particular specification and as recommended by Engr-in-charge and lubrication to all moving parts, topping up of oils as per lubrication chart including materials and labour for all consumable and major/minor spare parts. (iii) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical and control circuits and mechanical components of the lift that may occur during the operation.
(viii) The contractor shall submit the MOU with the OEM for carrying out comprehensive maintenance of lift at least 6 months prior to the date of completion of work.
SVS PROJECTS
GOPAL TEKNOCON PRIVATE LIMITED
jd constructions
RKEC PROJECTS LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid