GE 871 EWS
GE 871 EWS PIN 913871 C/o 56 APO
REPAIR REPLACEMENT OF UNSERVICEABLE INTERNAL WIRING LIGHT FITTING INCLUDING OTHER E M ALLIED WORKS AND COMPREHENSIVE MAINTENANCE OF WATER SUPPLY SYSTEM AT HARSIL SUKHI AND TEKLA UNDER GE 871 EWS
2023_MES_595487_1
8740/E8
Open Tender
Civil Works
Item Rate
180 days
Harsil Sukhi Tekla
as per NIT
8 documents required · 8 mandatory
₹500
GE 871 EWS
₹11,100
Yes
16 Aug 2023
16 May 2023
26 Jun 2023
16 May 2023
19 Jun 2023
30 May 2023
Amount
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, call bell and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified and directed.
M&L for point wiring in PVC casing & caping all as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Marked) and screws and rawal plug including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbles all as specified and directed for one light/bell point controlled by one ,one way switch.
All as per item No 2 above but one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one way switch.
All as per item No 2 above but one socket outlet 5 pin 5/6 Amps on the same board with other one, one way switch.
All as per item No 2 above but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 4 Sqmm for continuity earth wire connected to common earth dolly all as specified and directed.
M&L for point wiring in PVC concealed conduit as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Mark) and screws and rawal plugs including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbles all as specified and directed for One light/bell point controlled by one ,one way switch.
All as per item No 6 above but one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one way switch.
All as per item No 6 above but one socket outlet 5 pin 5/6 Amps on same board with other one, one way switch.
All as per item No 6 above but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 4 Sqmm for continuity earth wire connected to common earth dolly all as specified and directed.
S&F switch piano flush type 5/6 Amps single pole one way all as specified & directed.
S&F switch piano flush type 15/16 Amps single pole one way all as specified & directed.
S & F socket out let 5 pin 5/6 Amps all as specified and directed.
S&F socket out let 2-in-1, 6 pin 5/6 & 15/16 Amps all as specified and directed.
S&F ceiling rose 2/3 terminals 65x25 mm dia poly carbonate isolated all as specified & directed.
S&F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings.
S&F of bell push, flush type 5 Amps white or ivory, ISI marked all as specified and directed.
S&F call bell Ding Dong 230V, AC, single phase ISI marked all as specified and directed.
S&F in replacement of plug top 15 Amp white or ivory, ISI marked all as specified and directed.
S&F in replacement of plug top 5 Amp white or ivory, ISI marked.
S&F in replacement switch piano flush type 5/6 Amps single pole one way all as specified & directed.
S&F in replacement switch piano flush type 15/16 Amps single pole one way all as specified & directed.
S & F in replacement socket out let 5 pin 5/6 Amps all as specified and directed.
S&F in replacement socket out let 2-in-1, 6 pin 5/6 & 15/16 Amps all as specified and directed.
S&F 5 watt LED bulb. cool day light, 230/240V AC all as specified and directed.
S&F 9 watt LED bulb cool day light, 230/240V, AC all as specified and directed.
S&F in replacement of 5 watt LED bulb cool day light, 230/240V AC all as specified and directed.
S&F in replacement of 9 watt LED bulb cool day light, 230/240V, AC all as specified and directed.
S&F in replacement of LED light fitting, 1 x 10 watt bulk head luminaries, Landscape lighting fixture with all accessories and including connecting up with twin core twisted flexible copper conductor from ceiling rose to fitting connector all as specified and directed.
S&F in replacement of LED light fitting two feet 1x10 watt, slim design, 230volts, indoor recess mounting down light with reflector and detachable ballast tray, with lamp holder, connector block and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
S&F LED tube light fitting bright 18 watt. slim elegant design. and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
S&F in replacement of LED tube light fitting bright 18 watt. slim elegant design. and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
S&F in replacement of building security light fitting complete with 25 watt LED type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution complete fixed bracket made out of GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed.
M&L earthing complete with galvanised steel earth plate electrode size 600X600X6mm thick buried directly in ground vertically to a depth not less than 2.25m deep below normal ground level with top edge of earth plate not less than 1.5m deep below normal ground level and connected to and including GI earth lead wire 4mm dia by means of bolts, nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2009 and all as specified or indicated and testing on completion including excavation and earth work in any type of strata available at site, PCC (1:3:6) type C-1 earthing chamber, pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 15 mm bore light grade up to 7.5 metre long all as specified and directed. NOTE :- GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately.
Supply and fix in replacement of DB, SPN 4 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed.
Supply and fix in replacement of DB, SPN 8 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed.
Supply and fix in replacement MCB 32-40 amps, 10 KA, SP 240 volt, 'C' series all as specified and directed.
Supply and fix in replacement MCB 32-40 amps, 10 KA, DP 240 volt, 'C' series all as specified and directed.
All as per item No 37 hereinbefore but MCB DP 63 amps.
All as per item No 37 hereinbefore but MCB DP 100 amps.
Taking down/dismantling of defective/rusted storage type hot water Geyser of 50/35/25 litre capacity from different locations by disconnecting inlet/outlet connections and taking out unserviceable parts by unscrewing bolts and nuts, descaling/cleaning inner shell, servicing etc. checking defects, re-assembling and re-installing the Geyser in position, connection and testing all as specified & directed. Note: Supply and fixing of defective parts shall be measured and paid separately.
S&F PVC flexible pipes 15mm dia (heavy duty) both end socketed with washer 450 mm long for hot/cold water (ISI marked) all as specified & directed.
S&F PVC flexible pipes 15mm dia (heavy duty) both end socketed with washer 600 mm long for hot/cold water (ISI marked) all as specified & directed.
Supply and fix stop valve fancy type cast copper alloy screwed down high pressure with crutch or butter fly handle, chromium plated screwed both ends of size 15 mm bore, for geyser connection all as specified and directed.
S&F of inner tank 9 holes suitable for Geyser 25 liters capacity (Apparatus assembly) made copper duly prewired. Make : Usha/Lexus/Crompton
S&F of inner tank 6 holes suitable for Geyser 25 litres capacity (Apparatus assembly) made copper duly prewired. Make : Usha/Lexus/Crompton
S&F of inner tank 9 holes suitable for Geyser 35 litres capacity (Apparatus assembly) made copper duly prewired. Make : Usha/Lexus/Crompton
S&F of inner tank 6 holes suitable for Geyser 35 litres capacity (Apparatus assembly) made copper duly prewired. Make: Usha/Lexus/Crompton
S&F of Inner tank 9 holes suitable for Geyser 50 litres capacity (Apparatus assembly) made copper duly prewired. Make : Usha/Lexus/Crompton
S&F of Inner tank 6 holes suitable for Geyser 50 litres capacity (Apparatus assembly) made copper duly prewired. Make : Usha/Lexus/Crompton
S&F indication lamp (Green/Red) as per required at site all as specified & directed.
S&F thermal Auto cut of range 0-90 degree centigrade (ISI marked) all as specified and directed.
S&F geyser heating element 1.5 KW (ISI marked) round type/ thread/ triangle base type with the provision of thermal cut out all as specified and directed.
S&F geyser heating element 2 KW (ISI marked) round/thread/triangle base type with the provision of thermal cut out all as specified and directed.
S&F circular ring gasket for geyser assembly 6/9 holes as per site requirement (ISI Marked) all as specified & directed
S&F bottom plate as per existing size (ISI Marked) all as specified and directed
S&F Geyser assembly (nine holes) suitable for 25/35/50 litres geyser capacity (ISI Marked) complete all as specified and directed
S&F Geyser assembly (six holes) suitable for 25/35/50 litres geyser capacity (ISI Marked) all as specified and directed
Taking down carefully unserviceable exhaust fans of any size from its position, dismantling blades, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bush bearing, burnt winding, shaft, split pin, condenser, condenser holder, shackle, reassembling after replacement of defective parts including replacements of 3 core, 0.75sqmm (24/0.2mm) flexible copper cable from ceiling rose to connector, hanging on its position properly all as specified and directed. Note :- Defective parts like ball bearing, bush bearing and motor rewinding, shaft, condenser, rubber shackle will be measured and paid separately
S&F of ball /bush bearing suitable for exhaust fan of same size as that of existing defective one (ISI Marked) all as specified and directed. Make : SKF/TATA/Universal/polar
S&F of condenser suitable for exhaust fan capacity of 4/3.15/2 MFD all as specified and directed. Make : Usha/Universal/ Keltran
Cleaning and preparing the surfaces of exhaust fan any size, removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan all as specified and directed.
Excavation in trenches in hard dense soil not exceeding 1.5 metre width and not exc 1.5 metre deep for laying of pipe line and getting out all as specified and directed.
Returning, filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick in soil all as specified and directed.
Removing surplus soil to a distance nexc. 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and directed.
Dismantling and taking out old existing unserviceable GI pipe of size 100 mm dia from trenches/ under floor, roads, paths or from walls/poles/ducts all as specified and directed (Note:- Excavation & earth work shall be measured and paid for separately under respective item of this schedule)
All as per Item No 65 here-in-before but of size 80 mm bore
All as per Item No 65 here-in-before but of size 50 mm bore
All as per Item No 65 here-in-before but of size 40 mm bore
All as per Item No 65 here-in-before but of size 25 mm bore
All as per Item No 65 here-in-before but of size 20 mm bore
All as per Item No 65 here-in-before but of size 15 mm bore
Supply and laying in trenches GI water tubing 100 mm dia medium grade including all types of fittings and accessories all as specified and directed.
All as per Item No 72 here-in-before but of size 80 mm bore
All as per Item No 72 here-in-before but of size 50 mm bore
All as per Item No 72 here-in-before but of size 40 mm bore
All as per Item No 72 here-in-before but of size 25 mm bore
All as per Item No 72 here-in-before but of size 20 mm bore
All as per Item No 72 here-in-before but of size 15 mm bore
S&F 50 mm bore GI water tubing medium grade with all fittings, laid on wall, floor and ceiling including all types of fittings and accessories all as specified and directed.
All as per Item No 79 here-in-before but of size 40 mm bore
All as per Item No 79 here-in-before but of size 25 mm bore
All as per Item No 79 here-in-before but of size 20 mm bore
All as per Item No 79 here-in-before but of size 15 mm bore
Re-laying Including, jointing threading into trenches/wall/floors GI water tubing including all fittings and accessories etc bore of pipe 100 mm, all as specified and directed.
All as per Item No 84 here-in-before but of size 80 mm bore
All as per Item No 84 here-in-before but of size 50 mm bore
All as per Item No 84 here-in-before but of size 40 mm bore
All as per Item No 84 here-in-before but of size 25 mm bore
All as per Item No 84 here-in-before but of size 20 mm bore
All as per Item No 84 here-in-before but of size 15 mm bore
Dismantling/taking out of old unserviceable gate valve and supply and fixing new Gun metal gate valve/glove valve with Iron wheel head screwed both end for GI tubing of size 15 mm dia , all as specified and directed.
All as per Item No 91 here-in-before but of size 20 mm dia
All as per Item No 91 here-in-before but of size 25 mm dia
All as per Item No 91 here-in-before but of size 40 mm dia
All as per Item No 91 here-in-before but of size 50 mm dia
Supply & fix GI union 80mm dia ISI marked including dismantling and taking down of water supply lines as required at site to arrest the leakage of water supply line including excavation & earthwork, returning filling, removing, cutting & threading all as specified an directed at site.
All as per Item No 96 here-in-before but 50mm dia ISI marked.
All as per Item No 96 here-in-before but 40mm dia ISI marked.
All as per Item No 96 here-in-before but 25mm dia ISI marked.
All as per Item No 96 here-in-before but 20mm dia ISI marked.
All as per Item No 96 here-in-before but 15mm dia ISI marked.
All as per Item No 96 here-in-before but nipple 80mm dia 100 mm long ISI marked.
All as per Item No 96 here-in-before but GI nipple 50mm dia 100 mm long, ISI marked.
All as per Item No 96 here-in-before but GI nipple 40mm dia 100 mm long. ISI marked.
All as per Item No 96 here-in-before but GI nipple 25mm dia 100 mm long. ISI marked.
All as per Item No 96 here-in-before but GI nipple 20mm dia 100 mm long. ISI marked.
All as per Item No 96 here-in-before but GI nipple 15mm dia 100 mm long ISI marked.
All as per Item No 96 here-in-before but GI sockets 80mm dia ISI marked.
All as per Item No 96 here-in-before but GI sockets 50mm dia ISI marked.
All as per Item No 96 here-in-before but GI sockets 40mm dia ISI marked.
All as per Item No 96 here-in-before but GI sockets 25mm dia ISI marked.
All as per Item No 96 here-in-before but GI sockets 20mm dia ISI marked.
All as per Item No 96 here-in-before but GI sockets 15mm dia ISI marked.
All as per Item No 96 here-in-before but GI elbow 15 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI elbow 20 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI elbow 25 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI elbow 40 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI elbow 50 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI elbow 80 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI tee all equal of size 15 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI tee all equal of size 20 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI tee all equal of size 25 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI tee all equal of size 40 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI tee all equal of size 50 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI reducer socket 20 mm/15 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI reducer socket 25 mm/15 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI reducer socket 40 mm/15 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI reducer socket 25 mm/20 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI reducer socket 40 mm/20 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI reducer socket 50 mm/20 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI reducer socket 40 mm/25 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI reducer socket 50 mm/25 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI reducer socket 80 mm/50 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI plug of size 15 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI plug of size 20 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI plug of size 25 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI plug of size 40 mm dia suitable for GI Pipe medium grade ISI marked.
All as per Item No 96 here-in-before but GI plug of size 50 mm dia suitable for GI Pipe medium grade ISI marked.
Repair of service water tanks leakage from inlet pipe and connected to float valve by removing the short peace of pipe/barrel nipple from the RCC/PVC service tanks and replace the same and arrest the water leakage by using the water proofing material.
S&F in repairs of cast iron sluice valve of size 100 mm bore class-I PN-1.6 with gun metal spindle both end flanged with all fitting all as specified and directed.
S&F in repairs of cast iron sluice valve of size 80 mm bore class-I PN-1.6 with gun metal spindle both end flanged with all fitting all as specified and directed.
S&F in repairs galvanised iron flange on existing pipe of 100mm bore (02 Nos in each pipe) with nuts, bolts and washers complete all as specified and directed.
All as per item No 142 here in before but for 80 mm.
Testing of water for chemical test and bacterial test complete report in respect of water sample of Harsil station from IIT Roorkee or any NIT or any NABL approved lab.
M & L for cleaning of water storage RCC semi under ground sump, pumping out/taking out residual muddy water using mud pump or by manually including removing all sludge and dirt from wall and floors of sump and from pipe etc., by applying bleaching powder and by scrubbing with wire brushes and taking out all sludge/salt from sump and deposit at a distance exceeding 50m but n.exc 100mtr complete all as specified and directed by Engr-in-Charge. The empty sterilized with 2% solution of potassium permanganate and incl two coat of synthetic enamel cement base paint of external surface of the tank writing, location, capacity and date of cleaning with white paint over black paint firm and hand writing over a black paint with synthetic enameled paint etc complete for entire satisfaction to the to the Engr-in-Charge of the following size.
(a) 25000 Gallon capacity
(b) 10000 Gallon capacity
Taking out old air release valve and supply of Cast iron air release valve with two air outlet, 100mm dia bore incl massonary work for stand post of air release valve all as specified and as directed by Engineer-in-Charge.
M/S Swarn Constructions
SHANTI CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .