EE(E) BSNl ED KOTA
E-10B Exchange campus, Road no-2, IPIA, Kota
Rate contract for call basis repairing ,shifting, ITC of AC and miscellaneous work in BA Kota .
2021_BSNL_71125_1
23/20-21/BSNL/ED /KOTA
Open Tender
Electrical Works
Item Rate
180 days
kota
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
AO (Cash), O/o GMTD BSNL, KOTA
₹8,534
25 Mar 2021
23 Feb 2021
8 Mar 2021
23 Feb 2021
6 Mar 2021
23 Feb 2021
90 days
Amount
General Servicing of all type & capacity WAC/SAC/water cooler units at site of different make and model I/c removing from existing position if reqd, dismantling of faulty parts, cleaning the air filter, cleaning the condenser and evaporator coil with help of caustic soda soap solution, lubrication of moving parts, complete checking, testing and minor faults rectification i/c replacement of knobs/ wiring kit (if required), setting of thermostat, preparing report including tightness of all electrical connections from SP MCB in DB to DP MCB/Plug & socket to TDR to AC unit etc as reqd.
Replacement of the following capacity rotary type compressor I/c dismantling of the existing fulty compressor from AC unit , to and fro transportation charges and I/T/C of compressor in existing WAC / Split AC etc complete as required. Note: The agency has to provide one year guarantee for every replaced compressor along with Test Certificate / Invoice of Purchase from authorized dealer, Faulty Compressor shall be the property of contractor.
Replacement of the following capacity reciprocating type hermetically sealed compressor I/c dismantling of the existing faulty compressor from AC unit , to and fro transportation charges and I/T/C of compressor in existing WAC / Split AC etc complete as required. Note: The agency has to provide one year guarantee for every replaced compressor along with Test Certificate / Invoice of Purchase from authorized dealer, Faulty Compressor shall be the property of contractor.
Charging of Fresh Refrigerant gas R-22 /R-32/410 up to specified pressure(as per manufacturer's recommendation) in following capacity AC units and pressure testing by nitrogen, vaccumisation for 2 hours, purging with gas and testing commissioning of the AC unit etc. as reqd. Note: One job consists of charging of Gas in one compressor i.e.. One complete air conditioning circuit only.
Provision of Top up of R-22/R-32 /410 gas in existing all type Window A.C /Split A.C/ units, flushing, testing etc. as required.
Replacement of the following items/accessories in the existing WAC/SP AC/water cooler Units in place of faulty/unserviceable parts i/c dismantling of the faulty, fixing the new item and testing, connection etc. complete as reqd.
Starting Capacitor aluminum case
Running Capacitor aluminum case
Fan Motor Capacitor aluminum case
Blower /condenser fan blade
starting relay
Replacement of all type condenser / Blower fan motor for 1.5 / 2 TR Window/Split A.C/water cooler unit in lieu of damaged i/c connection etc as required.
Rewinding of existing all type Blower/condenser fan motor for 1.5/2 TR Window/Split A.C unit/water cooler i/c replacement of bush i/c oiling ,greasng etc as required
Installation, Testing & Commissioning of the 1.5 TR inverter type Split type AC unit at a specified location as per direction of Engg-In-charge by mounting/fitting Indoor and Outdoor units , making opening in wall, laying and fixing of both liquid and hot gas lines , inter connecting wiring for both indoor outdoor units up to 5 mtrs length and ,interconnecting the indoor unit and outdoor unit with refrigerant line, insulating the refrigerant pipe with expandable polyethylene Foam tubing unit and fixing with suitable MS shaddle , Leak testing entire system ,vacuemising the system ,charging of Refrigerant gas in the unit ,making power supply connections from the power point,and making good the damages etc.as required.
Pdg and Fixing additional 1/4"&5/8" size or size same as supplied by Split AC manufacturer refrigerant copper piping with 3x2.5 sq.mm. PVC Insulated PVC Sheathed copper cable i/c covering of Copper Pipe with polystyrene insulation i/c cutting ,brazing ,jointing,bends, sockets etc as reqd. ( Note- Combined Length shall be measured )
S/F of 50 mm dia 2 mm thick PVC pipe on wall / surface for protection of refrigerant pipe of split AC units etc.i/c elbo /bend /socket etc as complete as reqd.
S/F of 50 mm dia PVC green suction pipe with PVC sprial ribbed on wall / surface for protection of refrigerant pipe of split AC units i/c fixing with suitable MS shaddle etc.as te reqd.
Insulating the existing laid refrigerant pipe with expandable polyethylene Foam tubing unit and fixing with suitable MS shaddle etc as reqd
Supplying and fixing of following size of flexible copper cable on surface/ recess, suitable for work on 230 volt, 50 HZ AC supply i/c connection etc as reqd
3x2.5 sq mm
3x1.5 sq mm
Dismantling of the existing split /window type AC Unit/water cooler complete with indoor unit,outdoor unit stand, refrigerant piping,drain pipe,shifting the dismaltled items to a safe place in exchange premises and handing over to the incharge,packing of SPAC wall hole ,making good the damage etc as reqd (Note- Existing refrigerent from working Split AC to be stored in compressor before dismentling for further use at new location).
Transportation of Split /Window AC units/water cooler with all acessories like indoor ,outdoor unit ,copper pipe ,drain pipe ,partical board ,stand from One TE building to various TE /BTS sites in BA Kota up to 100 KM i/c. loading,unloading etc. as reqd.
Closing of existing window in AC area to prevent AC leakage/theft by brick masnoary i/c plastering , finishing etc complete as reqd as reqd.
S/F of 450 mm sweep heavy duty mark II oscillating type Padestal fan with 3 speed control regulator having powder coated guard and aluminium die cast blade ,1440 RPM speed suitable for working on 230 V 50 Hz single phase AC supply & i/c connection etc. complete as required (Almonard /Crompton/Bajaja or SS )
S/F of 20 mm wide PVC cassing capping on wall /roof wit suitalbe screw etc as reqd.
S/F of following MS items to be used for for frame work /Exhaust fan grill I/c Cutting , welding painting etc. as required.
35mm X 35mm X 5mm Angle iron
25mm X 25mm X 3mm Angle iron
1"x1" square MS wire mesh of 18 SWG wire
20 SWG MS Sheet
20x3 mm MS flat
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .